974 resultados para Acoustic spectrograms


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Parameters to distinguish normal from deviant voices in early childhood have not been established. The current study sought to auditorily and acoustically characterize voices of children, and to study the relationship between vocal behavior reported by teachers and the presence of vocal aberrations. Methods: One hundred children between four and 6 years and 11 months, who attended early childhood educational institutions, were included. The sample comprised 50 children with normal voices (NVG) and 50 with deviant voices (DVG) matched by gender and age. All participants were submitted to auditory and acoustic analysis of vocal quality and had their vocal behaviors assessed by teachers through a specific protocol. Results: DVG had a higher incidence of breathiness (p < 0.001) and roughness (p < 0.001), but not vocal strain (p = 0.546), which was similar in both groups. The average F-0 was lower in the DVG and a higher noise component was observed in this group as well. Regarding the protocol used "Aspects Related to Phonotrauma - Children's Protocol", higher means were observed for children from DVG in all analyzed aspects and also on the overall means (DVG = 2.15; NVG = 1.12, p < 0.001). In NVG, a higher incidence of vocal behavior without alterations or with discrete alterations was observed, whereas a higher incidence of moderate, severe or extreme alterations of vocal behavior was observed in DVG. Conclusions: Perceptual assessment of voice, vocal acoustic parameters (F-0, noise and GNE), and aspects related to vocal trauma and vocal behavior differentiated the groups of children with normal voice and deviant voice. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of numerical simulation in the design and evaluation of products performance is ever increasing. To a greater extent, such estimates are needed in a early design stage, when physical prototypes are not available. When dealing with vibro-acoustic models, known to be computationally expensive, a question remains, which is related to the accuracy of such models in view of the well-know variability inherent to the mass manufacturing production techniques. In addition, both academia and industry have recently realized the importance of actually listening to a products sound, either by measurements or by virtual sound synthesis, in order to assess its performance. In this work, the scatter of significant parameter variations on a simplified vehicle vibro-acoustic model is calculated on loudness metrics using Monte Carlo analysis. The mapping from the system parameters to sound quality metric is performed by a fully-coupled vibro-acoustic finite element model. Different loudness metrics are used, including overall sound pressure level expressed in dB and Specific Loudness in Sones. Sound quality equivalent sources are used to excite this model and the sound pressure level at the driver's head position is acquired to be evaluated according to sound quality metrics. No significant variation has been perceived when evaluating the system using regular sound pressure level expressed in in dB and dB(A). This happens because of the third-octave filters that averages the results under some frequency bands. On the other hand, Zwicker Loudness presents important variations, arguably, due to the masking effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effects of rapid maxillary expansion on facial morphology and on nasal cavity dimensions of mouth breathing children by acoustic rhinometry and computed rhinomanometry. METHODS: Cohort; 29 mouth breathing children with posterior crossbite were evaluated. Orthodontic and otorhinolaryngologic documentation were performed at three different times, i.e., before expansion, immediately after and 90 days following expansion. RESULTS: The expansion was accompanied by an increase of the maxillary and nasal bone transversal width. However, there were no significant differences in relation to mucosal area of the nose. Acoustic rhinometry showed no difference in the minimal cross-sectional area at the level of the valve and inferior turbinate between the periods analyzed, although rhinomanometry showed a statistically significant reduction in nasal resistance right after expansion, but were similar to pre-treatment values 90 days after expansion. CONCLUSION: The maxillary expansion increased the maxilla and nasal bony area, but was inefficient to increase the nasal mucosal area, and may lessen the nasal resistance, although there was no difference in nasal geometry. Significance: Nasal bony expansion is followed by a mucosal compensation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES]Durante la campaña La Bocaina 0497 se llevaron a cabo una serie de 14 lances con una red de arrastre pelágico de tipo comercial entre 20 y 700 m. de profundidad y una porspección acústica con una ecosonda SIMRAD EK-500 en aguas neríticas y oceánicas adyacentes a Lanzarote, Fuerteventura y Gran Canaria. Además se obtuvieron imágenes SST para obtener información de las condiciones hidrológicas en el área de estudio. Los resultados mostraron que la caballa Scomber japonicus presentaba gran variabilidad espacial en biomasa entre las diferentes localidades muestreadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] This paper presents a Boundary Elements (BE) approach for the efficiency improvement of road acoustic barriers, mora specifically, for the shape design optimization of top-edge devices in the search for the best designs in terms of screening performance, usually represented by the insertion loss (IL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous materials are widely used in many fields of industrial applications, to achieve the requirements of noise reduction, that nowadays derive from strict regulations. The modeling of porous materials is still a problematic issue. Numerical simulations are often problematic in case of real complex geometries, especially in terms of computational times and convergence. At the same time, analytical models, even if partly limited by restrictive simplificative hypotheses, represent a powerful instrument to capture quickly the physics of the problem and general trends. In this context, a recently developed numerical method, called the Cell Method, is described, is presented in the case of the Biot's theory and applied for representative cases. The peculiarity of the Cell Method is that it allows for a direct algebraic and geometrical discretization of the field equations, without any reduction to a weak integral form. Then, the second part of the thesis presents the case of interaction between two poroelastic materials under the context of double porosity. The idea of using periodically repeated inclusions of a second porous material into a layer composed by an original material is described. In particular, the problem is addressed considering the efficiency of the analytical method. A analytical procedure for the simulation of heterogeneous layers based is described and validated considering both conditions of absorption and transmission; a comparison with the available numerical methods is performed. ---------------- I materiali porosi sono ampiamente utilizzati per diverse applicazioni industriali, al fine di raggiungere gli obiettivi di riduzione del rumore, che sono resi impegnativi da norme al giorno d'oggi sempre più stringenti. La modellazione dei materiali porori per applicazioni vibro-acustiche rapprensenta un aspetto di una certa complessità. Le simulazioni numeriche sono spesso problematiche quando siano coinvolte geometrie di pezzi reali, in particolare riguardo i tempi computazionali e la convergenza. Allo stesso tempo, i modelli analitici, anche se parzialmente limitati a causa di ipotesi semplificative che ne restringono l'ambito di utilizzo, rappresentano uno strumento molto utile per comprendere rapidamente la fisica del problema e individuare tendenze generali. In questo contesto, un metodo numerico recentemente sviluppato, il Metodo delle Celle, viene descritto, implementato nel caso della teoria di Biot per la poroelasticità e applicato a casi rappresentativi. La peculiarità del Metodo delle Celle consiste nella discretizzazione diretta algebrica e geometrica delle equazioni di campo, senza alcuna riduzione a forme integrali deboli. Successivamente, nella seconda parte della tesi viene presentato il caso delle interazioni tra due materiali poroelastici a contatto, nel contesto dei materiali a doppia porosità. Viene descritta l'idea di utilizzare inclusioni periodicamente ripetute di un secondo materiale poroso all'interno di un layer a sua volta poroso. In particolare, il problema è studiando il metodo analitico e la sua efficienza. Una procedura analitica per il calcolo di strati eterogenei di materiale viene descritta e validata considerando sia condizioni di assorbimento, sia di trasmissione; viene effettuata una comparazione con i metodi numerici a disposizione.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Während in den letzten Jahren zahlreiche Biosensoren zum spezifischen Nachweis von DNA entwickelt wurden, ist die Anwendung oberflächen-sensitiver Methoden auf enzymatische Reaktionen ein vergleichsweise neues Forschungsgebiet. Trotz der hohen Empfindlichkeit und der Möglichkeit zur Echtzeit-Beobachtung molekularer Prozesse, ist die Anwendung dieser Methoden nicht etabliert, da die Enzymaktivität durch die Nähe zur Oberfläche beeinträchtigt sein kann. Im Rahmen dieser Arbeit wurde die enzymatische Verlängerung immobilisierter DNA durch eine DNA Polymerase mit Hilfe von Oberflächenplasmonen-Fluoreszenzspektroskopie (SPFS) und einer Quarzkristall-Mikrowaage (QCM) untersucht. Die Synthese von DNA wurde im Fall der QCM als Massenzuwachs detektiert, der sich im Abfall der Resonanzfrequenz des Schwingquarzes und einem Anstieg seiner Dissipationsenergie ausdrückte. Die viskoelastischen Eigenschaften der DNA-Schichten wurden bestimmt, indem die erhaltenen Daten mit einem auf Voigt basierenden Modell ausgewertet wurden. SPFS nutzt das evaneszente elektromagnetische Feld, das mit Oberflächenplasmonen einhergeht, zur oberflächen-sensitiven Anregung von Chromophoren. Auf diese Weise wurde der Einbau von Farbstoff-markierten Nukleotiden in die entstehende DNA-Sequenz als Indikator für das Voranschreiten der Reaktion ausgenutzt. Beide Meßtechniken konnten erfolgreich zum Nachweis der DNA-Synthese herangezogen werden, wobei die katalytische Aktivität des Enzyms vergleichbar zu der in Lösung gemessenen war.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mit der Zielsetzung der vorliegenden Arbeit wurde die detailierten Analyse von Migrationsdynamiken epithelilaler Monolayer anhand zweier neuartiger in vitro Biosensoren verfolgt, der elektrischen Zell-Substrat Impedanz Spektroskopie (electrical cell-substrate impedance sensing, ECIS) sowie der Quarz Kristall Mikrowaage (quartz crystal microbalance, QCM). Beide Methoden erwiesen sich als sensitiv gegenüber der Zellmotilität und der Nanozytotoxizität.rnInnerhalb des ersten Projektes wurde ein Fingerprinting von Krebszellen anhand ihrer Motilitätsdynamiken und der daraus generierten elektrischen oder akkustischen Fluktuationen auf ECIS oder QCM Basis vorgenommen; diese Echtzeitsensoren wurdene mit Hilfe klassicher in vitro Boyden-Kammer Migrations- und Invasions-assays validiert. Fluktuationssignaturen, also Langzeitkorrelationen oder fraktale Selbstähnlichkeit aufgrund der kollektiven Zellbewegung, wurden über Varianz-, Fourier- sowie trendbereinigende Fluktuationsanalyse quantifiziert. Stochastische Langzeitgedächtnisphänomene erwiesen sich als maßgebliche Beiträge zur Antwort adhärenter Zellen auf den QCM und ECIS-Sensoren. Des weiteren wurde der Einfluss niedermolekularer Toxine auf die Zytoslelettdynamiken verfolgt: die Auswirkungen von Cytochalasin D, Phalloidin und Blebbistatin sowie Taxol, Nocodazol und Colchicin wurden dabei über die QCM und ECIS Fluktuationsanalyse erfasst.rnIn einem zweiten Projektschwerpunkt wurden Adhäsionsprozesse sowie Zell-Zell und Zell-Substrat Degradationsprozesse bei Nanopartikelgabe charackterisiert, um ein Maß für Nanozytotoxizität in Abhangigkeit der Form, Funktionalisierung Stabilität oder Ladung der Partikel zu erhalten.rnAls Schlussfolgerung ist zu nennen, dass die neuartigen Echtzeit-Biosensoren QCM und ECIS eine hohe Zellspezifität besitzen, auf Zytoskelettdynamiken reagieren sowie als sensitive Detektoren für die Zellvitalität fungieren können.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il presente lavoro tratta la progettazione e caratterizzazione di una nuova "listening room" ad acustica controllata partendo dai requisiti dettati dalle norme tecniche ITU-R BS 1116-1 e EBU/UER Tech. doc. 3276. Ad oggi è presente un'ampia letteratura, che tratta approcci per valutazione acustica delle sale di ascolto. Essa inizialmente era volta a trovare proporzioni ideali tra le dimensioni della camera, poi la ricerca si è spostata sull'elaborazione di modelli previsionali. Purtroppo tali metodi spesso non riescono a garantire le prestazioni desiderate, mentre le prove sperimentali dettate dalle norme risultano essere di comprovata validità. L'ambiente oggetto di studio è stato progettato all'interno dello spazio dei laboratori CIRI. La tecnologia costruttiva è frutto di uno studio approfondito, in particolare la scelta di fibre di poliestere termolegate, per il rivestimento delle pareti interne, è stata valutata attraverso misure in camera riverberante secondo UNI-EN-ISO 354. Si è poi seguita una metodologia iterativa che coinvolgesse messa in opera, misurazioni in situ e valutazione tramite confronto con i parametri consigliati dalle normative tecniche sopra citate. In quest'ottica sono state effettuate acquisizioni di risposte all'impulso monoaurali e dei livelli di pressione sonora per verificare la qualità di isolamento e il comportamento alle basse frequenze. La validazione restituisce indicazioni positive per gli utilizzi dell'ambiente ipotizzati e risulta compatibile con le stringenti richieste delle norme tecniche.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fully controlled liquid injection and flow in hydrophobic polydimethylsiloxane (PDMS) two-dimensional microchannel arrays based on on-chip integrated, low-voltage-driven micropumps are demonstrated. Our architecture exploits the surface-acoustic-wave (SAW) induced counterflow mechanism and the effect of nebulization anisotropies at crossing areas owing to lateral propagating SAWs. We show that by selectively exciting single or multiple SAWs, fluids can be drawn from their reservoirs and moved towards selected positions of a microchannel grid. Splitting of the main liquid flow is also demonstrated by exploiting multiple SAW beams. As a demonstrator, we show simultaneous filling of two orthogonal microchannels. The present results show that SAW micropumps are good candidates for truly integrated on-chip fluidic networks allowing liquid control in arbitrarily shaped two-dimensional microchannel arrays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new 2-D hydrophone array for ultrasound therapy monitoring is presented, along with a novel algorithm for passive acoustic mapping using a sparse weighted aperture. The array is constructed using existing polyvinylidene fluoride (PVDF) ultrasound sensor technology, and is utilized for its broadband characteristics and its high receive sensitivity. For most 2-D arrays, high-resolution imagery is desired, which requires a large aperture at the cost of a large number of elements. The proposed array's geometry is sparse, with elements only on the boundary of the rectangular aperture. The missing information from the interior is filled in using linear imaging techniques. After receiving acoustic emissions during ultrasound therapy, this algorithm applies an apodization to the sparse aperture to limit side lobes and then reconstructs acoustic activity with high spatiotemporal resolution. Experiments show verification of the theoretical point spread function, and cavitation maps in agar phantoms correspond closely to predicted areas, showing the validity of the array and methodology.