980 resultados para screening method
Resumo:
Pesticides are among the most widely used chemicals in the world. Because of the widespread use of agricultural chemicals in food production, people are exposed to low levels of pesticide residues through their diets. Scientists do not yet have a total understanding of the health effects of these pesticide residues. This work aims to determine differences in terms of pesticide residue content in Portuguese strawberries grown using different agriculture practices. The Quick, Easy, Cheap, Effective, Rugged, and Safe sample preparation method was conducted and shown to have good performance for multiclass pesticides extraction in strawberries. The screening of 25 pesticides residue was performed by gas chromatography–tandem mass spectrometry. In quantitative validation, acceptable performances were achieved with recoveries of 70–120 and <12 % residual standard deviation for 25 pesticides. Good linearity was obtained for all the target compounds, with highly satisfactory repeatability. The limits of detection were in the range of 0.1–28 μg/kg. The method was applied to analyze strawberry samples from organic and integrated pest management (IPM) practices harvested in 2009–2010. The results showed the presence of fludioxonil, bifenthrin, mepanipyrim, tolylfluanid, cyprodinil, tetraconazole, and malathion when using IPM below the maximum residue levels.
Resumo:
Previous Monte Carlo studies have investigated the multileaf collimator (MLC) contribution to the build-up region for fields in which the MLC leaves were fully blocking the openings defined by the collimation jaws. In the present work, we investigate the same effect but for symmetric and asymmetric MLC defined field sizes (2×2, 4×4, 10×10 and 3×7 cm2). A Varian 2100C/D accelerator with 120-leaf MLC is accurately modeled fora6MVphoton beam using the BEAMnrc/EGSnrc code. Our results indicate that particles scattered from accelerator head and MLC are responsible for the increase of about 7% on the surface dose when comparing 2×2 and 10×10 cm2 fields. We found that the MLC contribution to the total build-up dose is about 2% for the 2×2 cm2 field and less than 1% for the largest fields.
Expert opinion on best practice guidelines and competency framework for visual screening in children
Resumo:
PURPOSE: Screening programs to detect visual abnormalities in children vary among countries. The aim of this study is to describe experts' perception of best practice guidelines and competency framework for visual screening in children. METHODS: A qualitative focus group technique was applied during the Portuguese national orthoptic congress to obtain the perception of an expert panel of 5 orthoptists and 2 ophthalmologists with experience in visual screening for children (mean age 53.43 years, SD ± 9.40). The panel received in advance a script with the description of three tuning competencies dimensions (instrumental, systemic, and interpersonal) for visual screening. The session was recorded in video and audio. Qualitative data were analyzed using a categorical technique. RESULTS: According to experts' views, six tests (35.29%) have to be included in a visual screening: distance visual acuity test, cover test, bi-prism or 4/6(Δ) prism, fusion, ocular movements, and refraction. Screening should be performed according to the child age before and after 3 years of age (17.65%). The expert panel highlighted the influence of the professional experience in the application of a screening protocol (23.53%). They also showed concern about the false negatives control (23.53%). Instrumental competencies were the most cited (54.09%), followed by interpersonal (29.51%) and systemic (16.4%). CONCLUSIONS: Orthoptists should have professional experience before starting to apply a screening protocol. False negative results are a concern that has to be more thoroughly investigated. The proposed framework focuses on core competencies highlighted by the expert panel. Competencies programs could be important do develop better screening programs.
Resumo:
Liver steatosis is a common disease usually associated with social and genetic factors. Early detection and quantification is important since it can evolve to cirrhosis. Steatosis is usually a diffuse liver disease, since it is globally affected. However, steatosis can also be focal affecting only some foci difficult to discriminate. In both cases, steatosis is detected by laboratorial analysis and visual inspection of ultrasound images of the hepatic parenchyma. Liver biopsy is the most accurate diagnostic method but its invasive nature suggest the use of other non-invasive methods, while visual inspection of the ultrasound images is subjective and prone to error. In this paper a new Computer Aided Diagnosis (CAD) system for steatosis classification and analysis is presented, where the Bayes Factor, obatined from objective intensity and textural features extracted from US images of the liver, is computed in a local or global basis. The main goal is to provide the physician with an application to make it faster and accurate the diagnosis and quantification of steatosis, namely in a screening approach. The results showed an overall accuracy of 93.54% with a sensibility of 95.83% and 85.71% for normal and steatosis class, respectively. The proposed CAD system seemed suitable as a graphical display for steatosis classification and comparison with some of the most recent works in the literature is also presented.
Resumo:
Beaches worldwide provide recreational opportunities to hundreds of millions of people and serve as important components of coastal economies. Beach water is often monitored for microbiological quality to detect the presence of indicators of human sewage contamination so as to prevent public health outbreaks associated with water contact. However, growing evidence suggests that beach sand can harbor microbes harmful to human health, often in concentrations greater than the beach water. Currently, there are no standards for monitoring, sampling, analyzing, or managing beach sand quality. In addition to indicator microbes, growing evidence has identified pathogenic bacteria, viruses, and fungi in a variety of beach sands worldwide. The public health threat associated with these populations through direct and indirect contact is unknown because so little research has been conducted relating to health outcomes associated with sand quality. In this manuscript, we present the consensus findings of a workshop of experts convened in Lisbon, Portugal to discuss the current state of knowledge on beach sand microbiological quality and to develop suggestions for standardizing the evaluation of sand at coastal beaches. The expert group at the "Microareias 2012" workshop recommends that 1) beach sand should be screened for a variety of pathogens harmful to human health, and sand monitoring should then be initiated alongside regular water monitoring; 2) sampling and analysis protocols should be standardized to allow proper comparisons among beach locations; and 3) further studies are needed to estimate human health risk with exposure to contaminated beach sand. Much of the manuscript is focused on research specific to Portugal, but similar results have been found elsewhere, and the findings have worldwide implications.
Resumo:
The deep-sea environment is difficult to sample, and often only small quantities of samples can be obtained when using less destructive methods than dredging. When working with marine animals that are difficult to sample and with limited quantities of tissue to extract lipids, it is essential to ensure that the used method extracts the maximum possible quantity of lipids. This study evaluates the efficiency of introducing modifications to the method originally described by Bligh & Dyer (1959). This lipid extraction method is broadly used with modifications, although these usually lack proper description and evaluation of increment in lipids. In this study we consider the improvement in terms of amount of lipids extracted by changing the method. Lipid content was determined by gravimetric measurements in eight invertebrates from the deep-sea, including deep-sea hydrothermal vents animals, using three different approaches. Results show increases of 14% to 30% in lipid contents obtained from hydrothermal vent invertebrate tissues and whole animals by placing the samples in methanol for 24 hours before applying the Bligh & Dyer mixture. Efficiency of the extractions using frozen and freeze-dried samples was also compared. For large sponges, the use of lyophilized materials resulted in increases of 3 to 7 times more lipids extracted when compared with extractions using frozen samples.
Resumo:
This paper aims to present a contrastive approach between three different ways of building concepts after proving the similar syntactic possibilities that coexist in terms. However, from the semantic point of view we can see that each language family has a different distribution in meaning. But the most important point we try to show is that the differences found in the psychological process when communicating concepts should guide the translator and the terminologist in the target text production and the terminology planning process. Differences between languages in the information transmission process are due to the different roles the different types of knowledge play. We distinguish here the analytic-descriptive knowledge and the analogical knowledge among others. We also state that none of them is the best when determining the correctness of a term, but there has to be adequacy criteria in the selection process. This concept building or term building success is important when looking at the linguistic map of the information society.
Resumo:
OBJECTIVE:To analyze factors associated with cervical cancer screening failure. METHODS:Population-based cross-sectional study with self-weighted two-stage cluster sampling conducted in the cities of Fortaleza (Northeastern Brazil) and Rio de Janeiro (Southeastern Brazil) in 2002. Subjects were women aged 25-59 years in the last three years prior to the study. Data were analyzed through Poisson regression using a hierarchical model. RESULTS: The proportion of women who did not undergo the Pap smear test in Fortaleza and Rio de Janeiro was 19.1% (95% CI: 16.1;22.1) and 16.5% (95% CI: 14.1;18.9), respectively. Higher prevalence ratios of cervical cancer screening failure in both cities were seen among women with low education and low per capita income, old age, unmarried, who never underwent mammography, clinical breast examination, and blood glucose and cholesterol level testing. Smokers also had lower screening rates compared to non-smoker women and this difference was only statistically significant in Rio de Janeiro. CONCLUSIONS:The study findings point to the need of intervention focusing particularly women in worse socioeconomic conditions and access to healthcare, old-aged and unmarried. Education activities must prioritize screening of asymptomatic women and early diagnosis for symptomatic women and access to adequate diagnostic methods and treatment should be provided.
Resumo:
A presente dissertação descreve o desenvolvimento e a caracterização de sensores ópticos com base em membranas de poli(cloreto de vinilo), PVC, para determinação de Norfloxacina em amostras do sector da aquacultura. Estes sensores basearam-se na reacção colorimétrica entre um metal imobilizado em PVC e a Norfloxacina. O metal foi escolhido com base em ensaios prévios de reacção colorimétrica entre a Norfloxacina e várias espécies metálicas, nomeadamente, Fe(III), Al(III), Pb(II), Aluminon, Mo(II), Mn(II), Ni(II), Cu(II), Co(II), Sn(II) e V(V). A reacção mais intensa foi obtida com o Fe(III). Neste sentido, numa primeira fase foram desenvolvidos sensores baseados em Fe(III). O efeito de alguns parâmetros experimentais na resposta desses sensores foi avaliado de modo univariado. Incluem-se aqui o efeito do pH, avaliado entre 2,00 e 6,00, e o da concentração de Fe(III), variada entre cerca de 1,00x10-5 M e 2,00x10-4 M. Os melhores valores foram obtidos a pH 3, para o qual se verificou um comportamento linear entre cerca de 1,00x10-5 M e 1,70x10-4 M de Fe(III). Utilizando as condições seleccionadas anteriormente, procedeu-se à caracterização do complexo sob ponto de vista químico. Os valores obtidos apontaram para a necessidade de um excesso de Fe(III) de, pelo menos, 10 vezes, no sentido de garantir a máxima extensão de complexação. O complexo referido apresentou, nestas condições, um comportamento linear ao longo do intervalo de concentrações de cerca de 7,00x10-5 M a 7,00x10-4 M em NOR. O complexo formado foi estável ao longo de 90 minutos. As condições óptimas para análise desse complexo numa superfície sólida foram obtidas após avaliação do efeito da quantidade de Fe(III) e do tipo e quantidade de solvente mediador (o-nitrofenil octil éter, di-n-octilftalato, dibutilftalato, bis(etilhexil)sebacato, bis(etilhexil)ftalato). O bis(etilhexil)sebacato foi o solvente mediador escolhido e a relação de quantidade entre o PVC e o solvente mediador foi igual a 1:2. O procedimento de preparação do sensor sólido e subsequente optimização foi aplicado a outras espécies metálicas, para além do Fe(III), tais como, Cu(II), Mn(II) e aluminon. A conjugação de todos estes metais permitiu desenvolver um array de sensores para despistagem de Norfloxacina em águas de aquacultura. Algumas membranas sensoras foram aplicadas com sucesso no controlo de Norfloxacina em amostras de águas ambientais dopadas. Os resultados obtidos com membranas de Fe(III) e Cu(II) foram exactos, tendo-se registado valores de concentração próximos dos reais. O método proposto permitiu, por isso, a despistagem rápida e eficaz da presença de um antibiótico em águas ambientais, permitindo ainda o seu doseamento a um baixo custo. Numa perspectiva de rotina, e tendo em vista a despistagem deste antibiótico, este método revelou-se mais rápido e mais barato do que os demais métodos descritos na literatura para este efeito.
Resumo:
Dissertação de Mestrado, Estudos Integrados dos Oceanos, 15 de Março de 2016, Universidade dos Açores.
Resumo:
Clinical and environmental samples from Portugal were screened for the presence of Aspergillus and the distributions of the species complexes were determined in order to understand how their distributions differ based on their source. Fifty-seven Aspergillus isolates from clinical samples were collected from 10 health institutions. Six species complexes were detected by internal transcribed spacer sequencing; Fumigati, Flavi, and Nigri were found most frequently (50.9%, 21.0%, and 15.8%, respectively). β-tubulin and calmodulin sequencing resulted in seven cryptic species (A. awamorii, A. brasiliensis, A. fructus, A. lentulus, A. sydowii, A. tubingensis, Emericella echinulata) being identified among the 57 isolates. Thirty-nine isolates of Aspergillus were recovered from beach sand and poultry farms, 31 from swine farms, and 80 from hospital environments, for a total 189 isolates. Eleven species complexes were found in these 189 isolates, and those belonging to the Versicolores species complex were found most frequently (23.8%). There was a significant association between the different environmental sources and distribution of the species complexes; the hospital environment had greater variability of species complexes than other environmental locations. A high prevalence of cryptic species within the Circumdati complex was detected in several environments; from the isolates analyzed, at least four cryptic species were identified, most of them growing at 37ºC. Because Aspergillus species complexes have different susceptibilities to antifungals, knowing the species-complex epidemiology for each setting, as well as the identification of cryptic species among the collected clinical isolates, is important. This may allow preventive and corrective measures to be taken, which may result in decreased exposure to those organisms and a better prognosis.
Resumo:
O presente trabalho pretendeu desenvolver e testar um sensor óptico para detectar ciclamato de sódio, um adoçante artificial utilizado nas bebidas em geral. A primeira abordagem neste sentido baseou-se na preparação de um sensor óptico através da formação de complexos corados entre o ciclamato e várias espécies metálicas, nomeadamente Hg(II), Ba(II), Fe(II), Ag(II), Pb(II), Cd(II), Mn (II), Ni(II), Cu(II), Co(II), Sn(II) e Mg(II). Perante a ausência de resultados satisfatórios optou-se por explorar a acção do ciclamato de sódio na transferência/partilha de um corante entre duas fases líquidas imiscíveis. As fases líquidas utilizadas foram a água e o clorofórmio. Testaram-se várias famílias de corantes mas só uma classe se mostrou com as características apropriadas para o objectivo pretendido. Dentro dessa família de corantes, seleccionou-se aquele que, à partida, garantiu o melhor desempenho. O sensor foi testado em diferentes condições de pH e também na presença de potenciais interferentes de forma a estabelecer as melhores condições de utilização. O método mostrou-se bastante simples de executar, rápido na obtenção de resultados e com boas características para ser avaliado visualmente, mas sempre de acordo com os critérios de objectividade que um trabalho deste tipo requer. Além o disso permitiu ser calibrado de uma forma rápida e simples, características essenciais para a aplicação deste método na despistagem de ciclamato em análises de rotina. O método desenvolvido foi ainda aplicado à análise de vinho dopado com diferentes concentrações de ciclamato de sódio. Destes testes verificou-se a necessidade de optimização do método através da introdução de outras substâncias na fase não aquosa diminuindo a vulnerabilidade do sensor a outros interferentes. Como conclusão, o método correspondeu às expectativas, mostrando-se viável para aplicação à análise de vinhos, ainda com uma margem significativa de desenvolvimento no sentido de o tornar mais fiável e preciso.
Resumo:
QuEChERS method was evaluated for extraction of 16 PAHs from fish samples. For a selective measurement of the compounds, extracts were analysed by LC with fluorescence detection. The overall analytical procedure was validated by systematic recovery experiments at three levels and by using the standard reference material SRM 2977 (mussel tissue). The targeted contaminants, except naphthalene and acenaphthene, were successfully extracted from SRM 2977 with recoveries ranging from 63.5–110.0% with variation coefficients not exceeding 8%. The optimum QuEChERS conditions were the following: 5 g of homogenised fish sample, 10 mL of ACN, agitation performed by vortex during 3 min. Quantification limits ranging from 0.12– 1.90 ng/g wet weight (0.30–4.70 µg/L) were obtained. The optimized methodology was applied to assess the safety concerning PAHs contents of horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), sardine (Sardina pilchardus) and farmed seabass (Dicentrarchus labrax). Although benzo(a)pyrene, the marker used for evaluating the carcinogenic risk of PAHs in food, was not detected in the analysed samples (89 individuals corresponding to 27 homogenized samples), the overall mean concentration ranged from 2.52 l 1.20 ng/g in horse mackerel to 14.6 ± 2.8 ng/ g in farmed seabass. Significant differences were found between the mean PAHs concentrations of the four groups.
Resumo:
A multiresidue approach using microwave-assisted extraction and liquid chromatography with photodiode array detection was investigated for the determination of butylate, carbaryl, carbofuran, chlorpropham, ethiofencarb, linuron,metobromuron, and monolinuron in soils. The critical parameters of the developed methodology were studied. Method validation was performed by analyzing freshly and aged spiked soil samples. The recoveries and relative standard deviations reached using the optimized conditions were between 77.0 ± 0.46% and 120 ± 2.9% except for ethiofencarb (46.4 ± 4.4% to 105 ± 1.6%) and butylate (22.1 ± 7.6% to 49.2 ± 11%). Soil samples from five locations of Portugal were analysed.