771 resultados para residential location


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The real estate dynamic originates new spatial forms, which can determine new uses and new places. We tried to analyze this work, the spatial transformations in the Ribeira district, Natal / RN, due to the advancement of the housing market that is gradually transforming the landscape with the introduction of new types of housing, especially by verticalization. The verticalization of the neighborhood occurs almost at once, changing the local landscape. Notwithstanding this process, given the rapid growth of Natal in the last two decades and the strategic location of the neighborhood, it is pertinent to note that, if not the process of vertical integration, perhaps the neighborhood had been at the mercy of other urban interventions and other approach the real estate market. The research used as instruments interviews with actors who work in the property market in the town and representatives of organizations that have implemented major legislation in the area, the Instituto de Patrimônio Histórico e Artístico Nacional (IPHAN) and the Secretaria de Meio Ambiente e Urbanismo (SEMURB) as well as photographs on the area, in order to verify this new configuration that has been consolidated in the district. To support the theoretical discussion, there was a documentary and bibliographical research. In this way, the object of study of this search sees the uniqueness of urban renewal in the district of Ribeira and its relationship with the historic preservation laws and incentives for residential occupation in the neighborhood, especially regarding the vertical building

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation seeks to reflect on the accessibility of the governmental program Minha Casa Minha Vida, track 1, which comprehends people who made 0 to 3 minimum wages within the metropolitan region of Natal RN between the years of 2009 and 2012. The research covers the municipalities benefited by the program: Ceará-Mirim, Extremoz, Macaíba, Monte Alegre, Natal, Nísia Floresta, Parnamirim and São Gonçalo do Amarante. We have investigated the extensions of PMCMV on the context of the access to the city, debating some concepts attached to the capitalist mode of production such as residential segregation and peripherization. We have aimed to identify the accessibility conditions in the new housing complexes from three primal categories, namely, the localization of the complexes, the disponibility of public equipments, services, leisure and cultural properties on the neighborhood and the offer of public transport. Our theorical references are based on the ideas of the british geographer David Harvey on his work Social Justice and the City , from 1980. Harvey s studies made us debate on the locational choice for the social-matter habitation, and also let us discuss the price to accessibility on these new programs and its implications on the income of those who are benefited by them, specially because this is about a low-income population. To the achievement of these objectives, we made use of case study, including desk research, photographic documentation, records of field observations and informal conversations with locals, composing a qualitative study. In light of what has been researched and considering the guiding research questions, we reflect on aspects of the program that can greatly influence the processes of residential segregation and housing periphery of the lowincome population from the precarious conditions of accessibility to the referred population

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a branch-and-price algorithm for the p-median location problem. The objective is to locate p facilities (medians) such as the sum of the distances from each demand point to its nearest facility is minimized. The traditional column generation process is compared with a stabilized approach that combines the column generation and Lagrangean/surrogate relaxation. The Lagrangean/surrogate multiplier modifies; the reduced cost criterion, providing the selection of new productive columns at the search tree. Computational experiments are conducted considering especially difficult instances to the traditional column generation and also with some large-scale instances. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuing development of new materials makes systems lighter and stronger permitting more complex systems to provide more functionality and flexibility that demands a more effective evaluation of their structural health. Smart material technology has become an area of increasing interest in this field. The combination of smart materials and artificial neural networks can be used as an excellent tool for pattern recognition, turning their application adequate for monitoring and fault classification of equipment and structures. In order to identify the fault, the neural network must be trained using a set of solutions to its corresponding forward Variational problem. After the training process, the net can successfully solve the inverse variational problem in the context of monitoring and fault detection because of their pattern recognition and interpolation capabilities. The use of structural frequency response function is a fundamental portion of structural dynamic analysis, and it can be extracted from measured electric impedance through the electromechanical interaction of a piezoceramic and a structure. In this paper we use the FRF obtained by a mathematical model (FEM) in order to generate the training data for the neural networks, and the identification of damage can be done by measuring electric impedance, since suitable data normalization correlates FRF and electrical impedance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A úlcera gástrica figura como uma importante causa de desconforto abdominal em eqüinos jovens. de acordo com a localização das lesões na mucosa gástrica, a presença ou ausência de sinais clínicos e possíveis complicações resultantes de sua ocorrência, quatro síndromes clínicas são freqüentemente descritas em potros: 1) Úlceras assintomáticas ou silenciosas; 2) Úlceras sintomáticas ou ativas; 3) Úlceras perfuradas; e 4) Obstruções gástrica ou duodenal. Com o objetivo de se verificar a distribuição de lesões gástricas (úlceras e/ou erosões) e descamações do epitélio aglandular no estômago de eqüinos jovens assim como uma possível relação entre as alterações mencionadas (lesão/descamação) sessenta potros da raça Quarto de Milha não-portadores de sinais clínicos compatíveis com úlceras gástricas foram submetidos à gastroscopia. Os potros foram divididos em quatro faixas etárias de 15 animais cada uma, sendo: 1 a 30 dias, 31 a 60 dias, 61 a 90 dias e 91 a 120 dias de idade. As lesões ocorreram em ordem decrescente de freqüência nas regiões aglandular próximo ao margo plicatus ao longo da curvatura maior, aglandular próximo à cárdia ao longo da curvatura menor, fundo glandular e aglandular e antro. As descamações do epitélio aglandular ocorreram de forma similar nas regiões de fundo e margo plicatus. Não houve associação entre a ocorrência de lesões e descamações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared.Material and methods: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect.Results: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23mm; TIU equicrestal -0.51mm; ANK subcrestal +0.19mm; TIU subcrestal -0.57mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted.Conclusions: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The vertical location of the implant-abutment connection influences the subsequent reaction of the peri-implant bone. It is not known, however, whether any additional influence is exerted by different microgap configurations. Therefore, the radiographic bone reactions of two different implant systems were monitored for 6 months. Materials and Methods: In eight mongrel dogs, two implants with an internal Morse-taper connection (INT group) were placed on one side of the mandible; the contralateral side received two implants with an external-hex connection (EXT group). on each side, one implant was aligned at the bone level (equicrestal) and the second implant was placed 1.5 mm subcrestal. Healing abutments were placed 3 months after submerged healing, and the implants were maintained for another 3 months without prosthetic loading. At implant placement and after 1, 2, 3, 4, 5, and 6 months, standardized radiographs were obtained, and peri-implant bone levels were measured with regard to microgap location and evaluated statistically. Results: All implants osseointegrated clinically and radiographically. The overall mean bone loss was 0.68 +/- 0.59 mm in the equicrestal INT group, 1.32 +/- 0.49 mm in the equicrestal EXT group, 0.76 +/- 0.49 mm in the subcrestal INT group, and 1.88 +/- 0.81 mm in the subcrestal EXT group. The differences between the INT and EXT groups were statistically significant (paired t tests). The first significant differences between the internal and external groups were seen at month 1 in the subcrestal groups and at 3 months in the equicrestal groups. Bone loss was most pronounced in the subcrestal EXT group. Conclusions: Within the limits of this study, different microgap configurations can cause different amounts of bone loss, even before prosthetic loading. Subcrestal placement of a butt-joint microgap design may lead to more pronounced radiographic bone loss. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:941-946

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The implant-abutment connection (microgap) influences the pen-implant bone morphology. However, it is unclear if different microgap configurations additionally modify bone reactions. This preliminary study aimed to radiographically monitor pen-implant bone levels in two different microgap configurations during 3 months of nonsubmerged healing. Materials and Methods: Six dogs received two implants with internal Morse taper connection (INT group) on one side of the mandible and two implants with external-hex connection (EXT group) on the other side. One implant on each side was positioned at bone level (equicrestal); the second implant was inserted 1.5 mm below the bone crest (subcrestal). Healing abutments were attached directly after implant insertion, and the implants were maintained for 3 months without prosthetic loading. At implant placement and 1, 2, and 3 months, standardized radiographs were taken to monitor pen-implant bone levels. Results: All implants osseointegrated. A total bone loss of 0.48 +/- 0.66 mm was measured in the equicrestal INT group, 0.69 +/- 0.43 mm in the equicrestal EXT group, 0.79 +/- 0.93 mm in the subcrestal INT group, and 1.56 +/- 0.53 mm in the subcrestal EXT group (P>.05, paired t tests). Within the four groups, bone loss over time became significantly greater in the EXT groups than in the INT groups. The greatest bone loss was noted in the subcrestal EXT group. Conclusion: Within the limits of this animal study, it seems that even without prosthetic loading, different microgap configurations exhibit different patterns of bone loss during nonsubmerged healing. Subcrestal positioning of an external butt joint microgap may lead to faster radiographic bone loss. Int J Prosthodont 2011;24:445-452.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: It is unknown whether different micro gap configurations can cause different pen-implant bone reactions. Therefore, this study sought to compare the peri-implant bone morphologies of two implant systems with different implant-abutment connections. Materials and Methods: Three months after mandibular tooth extractions in six mongrel dogs, two oxidized screw implants with an external-hex connection were inserted (hexed group) on one side, whereas on the contralateral side two grit-blasted screw implants with an internal Morse-taper connection (Morse group) were placed. on each side, one implant was inserted level with the bone (equicrestal) and the second implant was inserted 1.5 mm below the bony crest (subcrestal). Healing abutments were inserted immediately after implant placement. Three months later, the peri-implant bone levels, the first bone-to-implant contact points, and the width and steepness of the peri-implant bone defects were evaluated histometrically. Results: All 24 implants osseointegrated clinically and histologically. No statistically significant differences between the hexed group and Morse group were detected for either the vertical position for peri-implant bone levels (Morse equicrestal -0.16 mm, hexed equicrestal -0.22 mm, Morse subcrestal 1.50 mm, hexed subcrestal 0.94 mm) or for the first bone-to-implant contact points (Morse equicrestal -2.08 mm, hexed equicrestal -0.98 mm, Morse subcrestal -1.26 mm, hexed subcrestal -0.76 mm). For the parameters width (Morse equicrestal -0.15 mm, hexed equicrestal -0.59 mm, Morse subcrestal 0.28 mm, hexed subcrestal -0.70 mm) and steepness (Morse equicrestal 25.27 degree, hexed equicrestal 57.21 degree, Morse subcrestal 15.35 degree, hexed subcrestal 37.97 degree) of the pen-implant defect, highly significant differences were noted between the Morse group and the hexed group. Conclusion: Within the limits of this experiment, it can be concluded that different microgap configurations influence the size and shape of the peri-implant bone defect in nonsubmerged implants placed both at the crest and subcrestally. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:540-547

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.