982 resultados para ideal time


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cardiovascular disease is the leading cause of death in the world. Human C-reactive protein (CRP) has been used in the risk assessment of coronary events. Human saliva mirrors the body's health and well-being and is non-invasive, easy to collect and ideal for third world countries as well as for large patient screening. The aim was to establish a saliva CRP reference range and to demonstrate the clinical utility of salivary CRP levels in assessing the coronary events in a primary health care setting. Methods: We have used a homogeneous bead based assay to detect CRP levels in human saliva. We have developed a rapid 15 min (vs 90 min), sequential, one-step assay to detect CRP in saliva. Saliva was collected from healthy volunteers (n = 55, ages 20-70 years) as well as from cardiac patients (n = 28, ages 43-86 years). Results: The assay incubation time was optimised from 90 min to 15 mm and generated a positive correlation (n = 29, range 10-2189 pg/mL, r2 = 0.94; Passing Bablok slope 0.885. Intercept 0, p>0.10), meaning we could decrease the incubation time and produce equivalent results with confidence. The mean CRP level in the saliva of healthy human volunteers was 285 pg/mL and in cardiac patients was 1680 pg/mL (p<0.01). Analysis of CRP concentrations in paired serum and saliva samples from cardiac patients gave a positive correlation (r2 = 0.84, p<0.001) and the salivary CRP concentration capable of distinguishing healthy from diseased patients. Conclusions: The results suggest that this minimally invasive, rapid and sensitive assay will be useful in large patient screening studies for risk assessment of coronary events. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper seeks to identify the effect of the implementation of the European Working Time Directive (EWTD) on the working hours of UK doctors. The Labour Force Survey is used to compare the working hours of doctors with a variety of control groups before and after the implementation of the directive. The controls include those unconstrained by the directive and doctor counterparts working in Europe. We use differences-in-differences and matching methods to estimate the impact of this natural experiment, distinguishing between the anticipation and enactment of the EWTD. We find that the legislation reduced the hours of senior doctors by around 8 hours in total including the component attributable to anticipation effects and allowing for (exogenously set) rising wages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a simulation-based density estimation technique for time series that exploits information found in covariate data. The method can be paired with a large range of parametric models used in time series estimation. We derive asymptotic properties of the estimator and illustrate attractive finite sample properties for a range of well-known econometric and financial applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter examines how the methods, outcomes and transformative potentials of my new media arts praxis have been understood by a range of critical commentators from disciplinary perspectives outside of my own ‘home territory’ of media arts. By drawing upon perspectives from Human Computer Interface Design, Engineering, Sustainability Design, Tertiary Education, Communication Design and Public Librarianship I demonstrate how ideas from my arts disciplines have had tangible ‘external’ significance and application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deoxyribonucleic acid (DNA) extraction has considerably evolved since it was initially performed back in 1869. It is the first step required for many of the available downstream applications used in the field of molecular biology. Whole blood samples are one of the main sources used to obtain DNA, and there are many different protocols available to perform nucleic acid extraction on such samples. These methods vary from very basic manual protocols to more sophisticated methods included in automated DNA extraction protocols. Based on the wide range of available options, it would be ideal to determine the ones that perform best in terms of cost-effectiveness and time efficiency. We have reviewed DNA extraction history and the most commonly used methods for DNA extraction from whole blood samples, highlighting their individual advantages and disadvantages. We also searched current scientific literature to find studies comparing different nucleic acid extraction methods, to determine the best available choice. Based on our research, we have determined that there is not enough scientific evidence to support one particular DNA extraction method from whole blood samples. Choosing a suitable method is still a process that requires consideration of many different factors, and more research is needed to validate choices made at facilities around the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective. Healthcare-associated infection (HAI) surveillance programs are critical for infection prevention. Australia does not have a comprehensive national HAI surveillance program. The purpose of this paper is to provide an overview of established international and Australian statewide HAI surveillance programs and recommend a pathway for the development of a national HAI surveillance program in Australia. Methods. This study examined existing HAI surveillance programs through a literature review, a review of HAI surveillance program documentation, such as websites, surveillance manuals and data reports and direct contact with program representatives. Results. Evidence from international programs demonstrates national HAI surveillance reduces the incidence of HAIs. However, the current status of HAI surveillance activity in Australian states is disparate, variation between programs is not well understood, and the quality of data currently used to compose national HAI rates is uncertain. Conclusions. There is a need to develop a well-structured, evidence-based national HAI program in Australia to meet the increasing demand for validated reliable national HAI data. Such a program could be leveraged off the work of existing Australian and international programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Network Real-Time Kinematic (NRTK) is a technology that can provide centimeter-level accuracy positioning services in real time, and it is enabled by a network of Continuously Operating Reference Stations (CORS). The location-oriented CORS placement problem is an important problem in the design of a NRTK as it will directly affect not only the installation and operational cost of the NRTK, but also the quality of positioning services provided by the NRTK. This paper presents a Memetic Algorithm (MA) for the location-oriented CORS placement problem, which hybridizes the powerful explorative search capacity of a genetic algorithm and the efficient and effective exploitative search capacity of a local optimization. Experimental results have shown that the MA has better performance than existing approaches. In this paper we also conduct an empirical study about the scalability of the MA, effectiveness of the hybridization technique and selection of crossover operator in the MA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the recent development of advanced metering infrastructure, real-time pricing (RTP) scheme is anticipated to be introduced in future retail electricity market. This paper proposes an algorithm for a home energy management scheduler (HEMS) to reduce the cost of energy consumption using RTP. The proposed algorithm works in three subsequent phases namely real-time monitoring (RTM), stochastic scheduling (STS) and real-time control (RTC). In RTM phase, characteristics of available controllable appliances are monitored in real-time and stored in HEMS. In STS phase, HEMS computes an optimal policy using stochastic dynamic programming (SDP) to select a set of appliances to be controlled with an objective of the total cost of energy consumption in a house. Finally, in RTC phase, HEMS initiates the control of the selected appliances. The proposed HEMS is unique as it intrinsically considers uncertainties in RTP and power consumption pattern of various appliances. In RTM phase, appliances are categorized according to their characteristics to ease the control process, thereby minimizing the number of control commands issued by HEMS. Simulation results validate the proposed method for HEMS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Identifying current physical activity levels and sedentary time of preschool children is important for informing government policy and community initiatives. This paper reviewed studies reporting on physical activity and time spent sedentary among preschool-aged children (2-5 years) using objective measures. EVIDENCE ACQUISITION: Databases were searched for studies published up to and including April 2013 that reported on, or enabled the calculation of, the proportion of time preschool children spent sedentary and in light- and moderate to vigorous-intensity physical activity. A total of 40 publications met the inclusion criteria for physical activity and 31 met the inclusion criteria for sedentary time. Objective measures included ActiGraph, Actiwatch, Actical, Actiheart, and RT3 accelerometers, direct observation, and Quantum XL telemetry heart rate monitoring. Data were analyzed in May 2013. EVIDENCE SYNTHESIS: Considerable variation in prevalence estimates existed. The proportion of time children spent sedentary ranged from 34% to 94%. The time spent in light-intensity physical activity and moderate to vigorous-intensity physical activity ranged from 4% to 33% and 2% to 41%, respectively. CONCLUSIONS: The considerable variation of prevalence estimates makes it difficult to determine the "true" prevalence of physical activity and sedentary time in preschool children. Future research should aim to reduce inconsistencies in the employed methodologies to better understand preschoolers' physical activity levels and sedentary behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire resistance rating of light gauge steel frame (LSF) wall systems is obtained from fire tests based on the standard fire time-temperature curve. However, fire severity has increased in modern buildings due to higher fuel loads as a result of modern furniture and light weight constructions that make use of thermoplastics materials, synthetic foams and fabrics. Some of these materials are high in calorific values and increase both the spread of fire growth and heat release rate, thus increasing the fire severity beyond that of the standard fire curve. Further, the standard fire curve does not include a decay phase that is present in natural fires. Despite the increasing usage of LSF walls, their behaviour in real building fires is not fully understood. This paper presents the details of a research study aimed at developing realistic design fire curves for use in the fire tests of LSF walls. It includes a review of the characteristics of building fires, previously developed fire time-temperature curves, computer models and available parametric equations. The paper highlights that real building fire time-temperature curves depend on the fuel load representing the combustible building contents, ventilation openings and thermal properties of wall lining materials, and provides suitable values of many required parameters including fuel loads in residential buildings. Finally, realistic design fire time-temperature curves simulating the fire conditions in modern residential buildings are proposed for the testing of LSF walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated whether the night-time conspicuity of road workers can be enhanced by positioning retroreflective strips on the moveable joints in patterns that convey varying degrees of biological motion. Participants were 24 visually normal adults (12 young M = 26.8 years; 12 older M = 72.9 years). Visual acuity, contrast sensitivity and glare sensitivity were recorded for each participant. Experimenters acting as road workers walked in place on a closed road circuit within simulated road work sites, facing either the oncoming driver or the roadway (presenting sideways to the driver) and wearing one of four clothing conditions: (i) standard road worker vest; (ii) standard vest plus thigh-mounted retroreflective strips; (iii) standard vest plus retroreflective strips on ankles and knees; (iv) standard vest plus retroreflective strips positioned on the extremities in a configuration that conveyed biological motion (“biomotion”). As they drove along the closed road participants were instructed to press a button to indicate when they first recognized that a road worker was present. The results demonstrated that regardless of the direction of walking, road workers wearing biomotion clothing were recognized at significantly (p < 0.05) longer distances (3×), relative to the standard vest alone. Response distances were significantly shorter for the older drivers. Contrast sensitivity was a better predictor of the ability to recognize road workers than was visual acuity or glare sensitivity. We conclude that adding retroreflective strips in the biomotion configuration can significantly improve road worker conspicuity regardless of the road worker's orientation and the age of the driver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate the effect of different levels of refractive blur on real-world driving performance measured under day and nighttime conditions. Methods Participants included 12 visually normal, young adults (mean age = 25.8 ± 5.2 years) who drove an instrumented research vehicle around a 4 km closed road circuit with three different levels of binocular spherical refractive blur (+0.50 diopter sphere [DS], +1.00 DS, +2.00 DS) compared with a baseline condition. The subjects wore optimal spherocylinder correction and the additional blur lenses were mounted in modified full-field goggles; the order of testing of the blur conditions was randomized. Driving performance was assessed in two different sessions under day and nighttime conditions and included measures of road signs recognized, hazard detection and avoidance, gap detection, lane-keeping, sign recognition distance, speed, and time to complete the course. Results Refractive blur and time of day had significant effects on driving performance (P < 0.05), where increasing blur and nighttime driving reduced performance on all driving tasks except gap judgment and lane keeping. There was also a significant interaction between blur and time of day (P < 0.05), such that the effects of blur were exacerbated under nighttime driving conditions; performance differences were evident even for +0.50 DS blur relative to baseline for some measures. Conclusions The effects of blur were greatest under nighttime conditions, even for levels of binocular refractive blur as low as +0.50 DS. These results emphasize the importance of accurate and up-to-date refractive correction of even low levels of refractive error when driving at night.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper outlines a review carried out at Queensland University of Technology (QUT) in 2013 to identify the extent to which the centrally supported virtual learning environment met current and future learning and teaching needs. A range of consultation and investigation activities occurred from May to November to encourage open stakeholder feedback as well as to allow for reflection on alternative digital technologies, systems and strategies. This resulted in the development of nine recommendations, which, following a planning phase, will commence being implemented from mid-2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Weak cell-surface adhesion of cell lines to tissue culture surfaces is a common problem and presents technical limitations to the design of experiments. To overcome this problem, various surface coating protocols have been developed. However, a comparative and precise real-time measurement of their impact on cell behavior has not been conducted. The prostate cancer cell line LNCaP, derived from a patient lymph node metastasis, is a commonly used model system in prostate cancer research. However, the cells’ characteristically weak attachment to the surface of tissue culture vessels and cover slips has impeded their manipulation and analysis and use in high throughput screening. To improve the adherence of LNCaP cells to the culture surface, we compared different coating reagents (poly-L-lysine, poly-L-ornithine, collagen type IV, fibronectin, and laminin) and culturing conditions and analyzed their impact on cell proliferation, adhesion, morphology, mobility and gene expression using real-time technologies. The results showed that fibronectin, poly-L-lysine and poly-L-ornithine improved LNCaP cells adherence and provoked cell morphology alterations, such as increase of nuclear and cellular area. These coating reagents also induced a higher expression of F-actin and reduced cell mobility. In contrast, laminin and collagen type IV did not improve adherence but promoted cell aggregation and affected cell morphology. Cells cultured in the presence of laminin displayed higher mobility than control cells. All the coating conditions significantly affected cell viability; however, they did not affect the expression of androgen receptor-regulated genes. Our comparative findings provide important insight for the selection of the ideal coating reagent and culture conditions for the cancer cell lines with respect to their effect on proliferation rate, attachment, morphology, migration, transcriptional response and cellular cytoskeleton arrangement.