991 resultados para gradient test
Resumo:
Glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) were used to synthesize a monolithic capillary column containing reactive epoxy groups. Glutaraldehyde was introduced and linked to the monolith after a process of amination. An aqueous solution of commercial carrier ampholytes (CAs, Ampholine) was focused in such a polymer column. The primary amino groups of CAs reacted with glutaraldehyde along the capillary. CAs were immobilized at different positions in the column according to their isoelectric points (pl), resulting in a monolithic immobilized pH gradient (M-IPG). Isoelectric focusing (IEF) was performed without CAs in such an M-IPG column. Due to the covalent attachment of the CAs this M-IPG can be repeatedly used after its preparation. Good stability, linearity, and reproducibility were obtained.
Resumo:
A novel approach is proposed for the simultaneous optimization of mobile phase pH and gradient steepness in RP-HPLC using artificial neural networks. By presetting the initial and final concentration of the organic solvent, a limited number of experiments with different gradient time and pH value of mobile phase are arranged in the two-dimensional space of mobile phase parameters. The retention behavior of each solute is modeled using an individual artificial neural network. An "early stopping" strategy is adopted to ensure the predicting capability of neural networks. The trained neural networks can be used to predict the retention time of solutes under arbitrary mobile phase conditions in the optimization region. Finally, the optimal separation conditions can be found according to a global resolution function. The effectiveness of this method is validated by optimization of separation conditions for amino acids derivatised by a new fluorescent reagent.
Resumo:
A theoretical study on the velocity of electroosmotic flow (EOF) and the retention times of neutral solutes under multiple-step gradient of capillary electrochromatography (CEC) was carried out, focusing on that with three kinds of mobile phases. Through the model computations, the detaining time of the second kind of mobile phase in the column was proved to play an important role in affecting EOF. The variation speed of EOF was shown to be determined by the differences among dead times in different steps. In addition, the prediction of the retention times of 13 aromatic compounds under gradient mode was performed with the deduced equations. A relative error below 3.3% between the calculated and experimental values was obtained, which demonstrated the rationality of the theoretical deduction. Our study could not only improve the comprehension of stepwise gradient elution, but also be of significance for the further optimization of separation conditions in the analysis of complex samples.
Resumo:
Characteristics of electroosmotic flow (EOF) and the migration of neutral solutes under double stepwise gradient elution in capillary electrochromatography were studied systematically. EOF velocity proved to be the function of operation time changing with the introduction of the second mobile phase. Accordingly, the retention of components also changed. The migration of neutral solutes was studied under the following three situations; A, components eluted when the column was filled only with the first kind of mobile phase; B, solutes eluted still in the first kind of mobile phase while at that time two kinds of mobile phase coexisted in the column and C, samples eluted in the second kind of mobile phase. Equations to describe the retention times of components under these three kinds of conditions were deduced and applied to predict the retention times of 12 aromatic compounds. Relative errors between experimental and calculated values were below 5.0%, which proved the reliability of the equations. In addition, parameters that might affect the retention time of solutes, such as the transferring time of mobile phase vials, the capacity factors of components and EOF velocities two steps were studied systematically (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
We describe a new molecular approach to analyzing the genetic diversity of complex microbial populations. This technique is based on the separation of polymerase chain reaction-amplified fragments of genes coding for 16S rRNA, all the same length, by denaturing gradient gel electrophoresis (DGGE). DGGE analysis of different microbial communities demonstrated the presence of up to 10 distinguishable bands in the separation pattern, which were most likely derived from as many different species constituting these populations, and thereby generated a DGGE profile of the populations. We showed that it is possible to identify constituents which represent only 1% of the total population. With an oligonucleotide probe specific for the V3 region of 16S rRNA of sulfate-reducing bacteria, particular DNA fragments from some of the microbial populations could be identified by hybridization analysis. Analysis of the genomic DNA from a bacterial biofilm grown under aerobic conditions suggests that sulfate-reducing bacteria, despite their anaerobicity, were present in this environment. The results we obtained demonstrate that this technique will contribute to our understanding of the genetic diversity of uncharacterized microbial populations.
Resumo:
The most biological diversity on this planet is probably harbored in soils. Understanding the diversity and function of the microbiological component of soil poses great challenges that are being overcome by the application of molecular biological approaches. This review covers one of many approaches being used: separation of polymerase chain reaction (PCR) amplicons using denaturing gradient gel electrophoresis (DGGE). Extraction of nucleic acids directly from soils allows the examination of a community without the limitation posed by cultivation. Polymerase chain reaction provides a means to increase the numbers of a target for its detection on gels. Using the rRNA genes as a target for PCR provides phylogenetic information on populations comprising communities. Fingerprints produced by this method have allowed spatial and temporal comparisons of soil communities within and between locations or among treatments. Numerous samples can be compared because of the rapid high throughput nature of this method. Scientists now have the means to begin addressing complex ecological questions about the spatial, temporal, and nutritional interactions faced by microbes in the soil environment.
Resumo:
Chinese Academy of Sciences (ISCAS)
Resumo:
利用供沙土槽和试验土槽的双土槽径流小区 ,定量研究了在不同降雨强度下上方来水来沙对陡坡地细沟侵蚀产沙过程和细沟水流水力学参数的影响及其细沟水流水力学特征参数与细沟侵蚀产沙量的关系。结果表明 :坡面细沟侵蚀过程以侵蚀—搬运过程为主 ,坡上方来沙不仅被径流全部搬运 ,且上方来水在坡下方引起了另外的侵蚀产沙量 ,其值随上方来水含沙量的减少和降雨强度的增加而增大。上方来水的汇入或降雨强度的增大可使细沟水流流态由层流转化为紊流。上方来水对细沟水流水力学参数 (流速、水力半径、雷诺数、弗劳德数和阻力系数 )有重要影响。定量分析了细沟水流水力学特征参数 (流速、雷诺数和阻力系数 )与上坡来水引起坡下方净侵蚀产沙量的关系 ,建立了净侵蚀产沙量与细沟水流流速、雷诺数和阻力系数统计模型。
Resumo:
黄土丘陵沟壑区地形变化异常复杂 ,1∶5万地形图对原始 1∶1万地形图等高线形态综合、取舍程度很大 ,这些都在不同程度上影响了地形分析结果的准确性。以高精度的 1∶1万比例尺DEM为校准值 ,运用 1∶1万及 1∶5万比例尺DEM叠合比较分析的方法 ,研究 1∶5万DEM的地形信息容量及提取不同地形要素的精度。试验结果表明 ,在黄土丘陵区 ,与 1∶1万DEM相比 ,1∶5万DEM在所提取的地面坡度、地面曲率、沟壑量等地形定量指标方面均都存在着较大的误差。
Resumo:
以陕北绥德县韭园沟流域为试验样区 ,采用高精度 1∶ 1万 DEM所提取的坡度为准值 ,应用多层面复合分析和比较分析的方法 ,研究该地区 1∶ 5万 DEM提取地面坡度的误差特征与纠正方法。试验结果显示 ,所获得的不同空间尺度下 DEM所提取坡度值的转换图谱 ,可对 1∶ 5万 DEM计算的地面坡度统计值进行有效修正。该成果对于 DEM数据在水土保持领域若干应用标准的制定 ,提供了重要的理论依据与技术路线
Resumo:
Association for Computing Machinery, ACM; IEEE; IEEE Computer Society; SIGSOFT
Resumo:
In this paper, we have prepared of a topography/chemical composition gradient polystyrene (PS) surface, i.e., an orthogonal gradient surface, to investigate the relationship between surface wettability and surface structure and chemical composition. The prepared surface shows a one-dimensional gradient in wettability in the x, y, and diagonal directions, including hydrophobic to hydrophilic, superhydrophobic to hydrophobic, superhydrophobic to superhydrophilic gradients, and so forth.
Resumo:
In this paper, we prepared "dual-parallel-channel" shape-gradient surfaces, on which water droplets can reversibly and orientedly move between two adjacent pools under the guidance of an external voltage. Furthermore, it is found that the motion speed is governed by several parameters, including bath condition, gradient angle, and the working voltage. In this self-transportation process of water droplets, the external voltage works like a traffic light, which can give "moving", "stopping", "turning" and "straight-going" signals to the Water droplets.