970 resultados para critical density plasma


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and reproducible method by microextraction packed sorbent and liquid chromatography with UV detection (MEPS/LC-UV) is described for the determination of new generation antidepressants (sertraline, mirtazapine, fluoxetine, citalopram and paroxetine) in human plasma samples. The MEPS variables, such as sample volume, pH, number of extraction cycles (draw-eject), and desorption conditions (solvent and solvent volume of elution) influenced the MEPS/LC efficiency significantly. Important factors in the optimization of MEPS efficiency, as well as washing steps and carryover effect are discussed. The analyses were carried out using small sample volumes (400 mu L.), and in a short time period (3 min for the entire sample preparation step). The MEPS/LC-UV method was shown to be linear at concentrations ranging from the limit of quantification (LOQ) to 1000 ng mL(-1). The LOQ values ranged from 10 to 25 ng mL(-1). The inter-day precision of the method presented coefficient of the variation ranging from 1.3% to 8.7%. On the basis of analytical validation, it is shown that the MEPS/LC-UV methodology is adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the MEPS/LC-UV method was applied to analysis of plasma samples from elderly depressed patients. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and reproducible stir bar-sorptive extraction and high performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of rifampicin in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. This miniaturized method can result in faster analysis, higher sample throughput, lower solvent consumption and less workload per sample while maintaining or even improving sensitivity. Important factors in the optimization of SBSE efficiency such as pH, temperature, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) were optimized recoveries ranging from 75 to 80%. Separation was obtained using a reverse phase C(8) column with UV detection (254 nm). The mobile phase consisted of methanol:0.25 N sodium acetate buffer, pH 5.0 (58:42, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.125-50.0 mu g mL(-1). The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.25, 6.25 and 25.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 10% and all inter-CVs were less than 10%. Limits of quantification were 0.125 mu g mL(-1). Stability studies showed rifampicin was stable in plasma for 12 h after thawing; the samples were also stable for 24 h after preparation. Based on the figures of merit results, the SBSE/HPLC-UV proved to be adequate to the rifampicin analyses from therapeutic to toxic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical and bioanalytical methods of high-performance liquid chromatography with fluorescence detection (HPLC-FLD) were developed and validated for the determination of chloroaluminum phthalocyanine in different formulations of polymeric nanocapsules, plasma and livers of mice. Plasma and homogenized liver samples were extracted with ethyl acetate, and zinc phthalocyanine was used as internal standard. The results indicated that the methods were linear and selective for all matrices studied. Analysis of accuracy and precision showed adequate values, with variations lower than 10% in biological samples and lower than 2% in analytical samples. The recoveries were as high as 96% and 99% in the plasma and livers, respectively. The quantification limit of the analytical method was 1.12 ng/ml, and the limits of quantification of the bioanalytical method were 15 ng/ml and 75 ng/g for plasma and liver samples, respectively. The bioanalytical method developed was sensitive in the ranges of 15-100 ng/ml in plasma and 75-500 ng/g in liver samples and was applied to studies of biodistribution and pharmacokinetics of AlClPc. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, selective, and reproducible in-tube polypyrrole-coated capillary (PPY) solid-phase microextraction and liquid chromatographic method for fluoxetine and norfluoxetine enantiomers analysis in plasma samples has been developed, validated, and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. Separation of the analytes was achieved with a Chiralcel OD-R column and a mobile phase consisting of potassium hexafluorophosphate 7.5 mM and sodium phosphate 0.25 M solution, pH 3.0, and acetonitrile (75:25, v/v) in the isocratic mode, at a flow rate of 1.0 mL/min. Detection was carried out by fluorescence absorbance at Ex/Em 230/290 nm. The multifunctional porous surface structure of the PPY-coated film provided high precision and accuracy for enantiomers. Compared with other commercial capillaries, PPY-coated capillary showed better extraction efficiency for all the analytes. The quantification limits of the proposed method were 10 ng/mL for R- and S-fluoxetine, and 15 ng/mL for R- and S-norfluoxetine, with a coefficient of variation lower than 13%. The response of the method for enantiomers is linear over a dynamic range, from the limit of quantification to 700ng/mL, with correlation coefficients higher than 0.9940. The in-tube SPME/LC method can therefore be successfully used to analyze plasma samples from ageing patients undergoing therapy with fluoxetine. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical oxidation of acid black 210 dye (AB-210) on the boron-doped diamond (BDD) was investigated under different pH conditions. The best performance for the AB-210 oxidation occurred in alkaline phosphate solution. This is probably due to oxidizing agents such as phosphate radicals and peroxodiphosphate ions, which can be electrochemically produced with good yields on the BDD anode, mainly in alkaline solution. Under this condition, the COD (chemical oxygen demand) removal was higher than that obtained from the model proposed by Comninellis. Electrolyses performed in phosphate buffer and in the presence of chloride ions resulted in faster COD and color removals in acid and neutral solutions, but in alkaline phosphate solution, a better performance in terms of TOC removal was obtained in the absence of chloride. Moreover, organochloride compounds were detected in all electrolyses performed in the presence of chloride. The AB-210 electrooxidation on BDD using phosphate as supporting electrolyte proved to be interesting since oxidizing species generated from phosphate ions were able to completely degrade the dye without producing organochloride compounds. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and automated method is described for determination of rifampicin in plasma samples for therapeutic drug monitoring by in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC). Important factors in the optimization of in-tube SPME are discussed, such as coating type, sample pH, sample draw/eject volume, number of draw/eject cycles, and draw/eject flow rate. Analyte pre-concentrated in the polyethylene glycol phase was directly transferred to the liquid chromatographic column by percolation of the mobile phase, without carryover. The method was linear over the 0.1-100 mu g/mL range, with a linear coefficient value (r(2)) of 0.998. The inter-assay precision presented coefficient of variation <= 1.7%. The effectiveness and practicability of the proposed method are proven by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study objective: To investigate the effect of the voluntary folate fortification policy in Australia on serum folate and total plasma homocysteine (tHcy) concentrations. Design: Population based cohort study. Setting: Perth, Western Australia. Participants: Men and women aged 27 to 77 years (n = 468), who were originally randomly selected from the Perth electoral roll. The cohort was surveyed in 1995/96 before widespread introduction of folate fortification of a variety of foods, and followed up on two occasions, firstly in 1998/99 and again in 2001, when a moderate number of folate fortified foods were available. Subjects with abnormal serum creatinine concentrations at baseline were excluded from this analysis. Main results: Repeated measures analysis of variance was used to determine changes in serum folate and tHcy over the three surveys and to assess whether time trends were related to age, sex, MTHFR C677T genotype, or consumption of folate fortified foods. An increase (38%) in mean serum folate (p < 0.0005) and a decrease (21%) in mean tHcy (p < 0.0005) were seen after introduction of the voluntary folate fortification policy in Australia. Serum folate was consistently higher (p = 0.032) and tHcy was consistently lower (p = 0.001) in subjects who consumed at least one folate fortified food compared with subjects who did not consume any folate fortified foods in the previous week. The time related changes in serum folate and tHcy were affected only by intake of folate fortified foods (p < 0.0005) and not by any other measured variables including age, sex, or MTHFR genotype. Conclusion: Voluntary fortification of foods with folate in Australia has been followed by a substantial increase in serum folate and decrease in tHcy in the general population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We calculate the density profiles and density correlation functions of the one-dimensional Bose gas in a harmonic trap, using the exact finite-temperature solutions for the uniform case, and applying a local density approximation. The results are valid for a trapping potential that is slowly varying relative to a correlation length. They allow a direct experimental test of the transition from the weak-coupling Gross-Pitaevskii regime to the strong-coupling, fermionic Tonks-Girardeau regime. We also calculate the average two-particle correlation which characterizes the bulk properties of the sample, and find that it can be well approximated by the value of the local pair correlation in the trap center.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Homozygous familial hypercholesterolaemia is a rare genetic disorder in which both LDL-receptor alleles are defective, resulting in very high concentrations of LDL cholesterol in plasma and premature coronary artery disease. This study investigated whether an antisense inhibitor of apolipoprotein B synthesis, mipomersen, is effective and safe as an adjunctive agent to lower LDL cholesterol concentrations in patients with this disease. Methods This randomised, double-blind, placebo-controlled, phase 3 study was undertaken in nine lipid clinics in seven countries. Patients aged 12 years and older with clinical diagnosis or genetic confirmation of homozygous familial hypercholesterolaemia, who were already receiving the maximum tolerated dose of a lipid-lowering drug, were randomly assigned to mipomersen 200 mg subcutaneously every week or placebo for 26 weeks. Randomisation was computer generated and stratified by weight (<50 kg vs >= 50 kg) in a centralised blocked randomisation, implemented with a computerised interactive voice response system. All clinical, medical, and pharmacy personnel, and patients were masked to treatment allocation. The primary endpoint was percentage change in LDL cholesterol concentration from baseline. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00607373. Findings 34 patients were assigned to mipomersen and 17 to placebo; data for all patients were analysed. 45 patients completed the 26-week treatment period (28 mipomersen, 17 placebo). Mean concentrations of LDL cholesterol at baseline were 11.4 mmol/L (SD 3.6) in the mipomersen group and 10.4 mmol/L (3.7) in the placebo group. The mean percentage change in LDL cholesterol concentration was significantly greater with mipomersen (-24.7%, 95% CI 31.6 to 17.7) than with placebo (-3.3%, 12.1 to 5.5; p=0.0003). The most common adverse events were injection-site reactions (26 [76%] patients in mipomersen group vs four [24%] in placebo group). Four (12%) patients in the mipomersen group but none in the placebo group had increases in concentrations of alanine aminotransferase of three times or more the upper limit of normal. Interpretation Inhibition of apolipoprotein B synthesis by mipomersen represents a novel, effective therapy to reduce LDL cholesterol concentrations in patients with homozygous familial hypercholesterolaemia who are already receiving lipid-lowering drugs, including high-dose statins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Differences between women and men have been documented for both diagnostic testing and treatment in cardiology. This analysis evaluates whether low-density lipoprotein cholesterol (LDL-C) success rates according to current guidelines and high-density lipoprotein cholesterol (HDL-C) levels differ by gender in the L-TAP 2 population. Methods Patients aged >= 20 years with dyslipidemia on stable lipid-lowering therapy were assessed in 9 countries between September 2006 and April 2007. Low-density lipoprotein cholesterol goal attainment by cardiovascular risk level and region and determinants of low HDL-C were compared between genders. Results Of 9,955 patients (45.3% women) evaluated, women had a significantly lower overall LDL-C success rate than men (71.5% vs 73.7%, P = .014), due entirely to the difference in the high-risk/coronary heart disease (CHD) group (LDL-C goal <100 mg/dL, 62.6% vs 70.6%, P < .0001) Among CHD patients with >= 2 additional risk factors, only 26.7% of women and 31.5% of men (P = .021) attained the optional LDL-C goal of <70 mg/dL. High-density lipoprotein cholesterol was <50 mg/dL in 32.2% of women and <40 mg/dL in 26.8% of men (P < .0001), including 38.2% of women and 29.8% of men in the high risk/CHD group (P < .0001). Predictors of low HDL-C in women included diabetes, smoking, waist circumference, and hypertension. Conclusions Cholesterol treatment has, improved substantially since the original L-TAP a decade ago, when only 39% of women attained their LDL-C goal. However, high-risk women are undertreated compared to men, and a substantial opportunity remains to reduce their cardiovascular risk. (Am Heart J 2009; 158:860-6.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-Information about physicians` adherence to cholesterol management guidelines remains scant. The present survey updates our knowledge of lipid management worldwide. Methods and Results-Lipid levels were determined at enrollment in dyslipidemic adult patients on stable lipid-lowering therapy in 9 countries. The primary end point was the success rate, defined as the proportion of patients achieving appropriate low-density lipoprotein cholesterol (LDL-C) goals for their given risk. The mean age of the 9955 evaluable patients was 62 +/- 12 years; 54% were male. Coronary disease and diabetes mellitus had been diagnosed in 30% and 31%, respectively, and 14% were current smokers. Current treatment consisted of a statin in 75%. The proportion of patients achieving LDL-C goals according to relevant national guidelines ranged from 47% to 84% across countries. In low-, moderate-, and high-risk groups, mean LDL-C was 119, 109, and 91 mg/dL and mean high-density lipoprotein cholesterol was 62, 49, and 50 mg/dL, respectively. The success rate for LDL-C goal achievement was 86% in low-, 74% in moderate-, and 67% in high-risk patients (73% overall). However, among coronary heart disease patients with >= 2 risk factors, only 30% attained the optional LDL-C goal of < 70 mg/dL. In the entire cohort, high-density lipoprotein cholesterol was < 40 mg/dL in 19%, 40 to 60 mg/dL in 55%, and > 60 mg/dL in 26% of patients. Conclusions-Although there is room for improvement, particularly in very-high-risk patients, these results indicate that lipid-lowering therapy is being applied much more successfully than it was a decade ago. (Circulation. 2009; 120: 28-34.)