930 resultados para Confusion bias
Resumo:
Combined tunable WDM converters based on SiC multilayer photonic active filters are analyzed. The operation combines the properties of active long-pass and short-pass wavelength filter sections into a capacitive active band-pass filter. The sensor element is a multilayered heterostructure produced by PE-CVD. The configuration includes two stacked SiC p-i-n structures sandwiched between two transparent contacts. Transfer function characteristics are studied both theoretically and experimentally. Results show that optical bias activated photonic device combines the demultiplexing operation with the simultaneous photodetection and self amplification of an optical signal acting the device as an integrated photonic filter in the visible range. Depending on the wavelength of the external background and irradiation side, the device acts either as a short- or a long-pass band filter or as a band-stop filter. The output waveform presents a nonlinear amplitude-dependent response to the wavelengths of the input channels. A numerical simulation and a two building-blocks active circuit are presented and give insight into the physics of the device. (c) 2013 Elsevier B.V. All rights reserved.
Resumo:
Copyright © 2014 The Authors. Methods in Ecology and Evolution © 2014 British Ecological Society.
Resumo:
It is presented in this paper a study on the photo-electronic properties of multi layer a-Si: H/a-SiC: H p-i-n-i-p structures. This study is aimed to give an insight into the internal electrical characteristics of such a structure in thermal equilibrium, under applied Was and under different illumination condition. Taking advantage of this insight it is possible to establish a relation among-the electrical behavior of the structure the structure geometry (i.e. thickness of the light absorbing intrinsic layers and of the internal n-layer) and the composition of the layers (i.e. optical bandgap controlled through percentage of carbon dilution in the a-Si1-xCx: H layers). Showing an optical gain for low incident light power controllable by means of externally applied bias or structure composition, these structures are quite attractive for photo-sensing device applications, like color sensors and large area color image detector. An analysis based on numerical ASCA simulations is presented for describing the behavior of different configurations of the device and compared with experimental measurements (spectral response and current-voltage characteristic). (c) 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
We present measurements and numerical simulation of a-Si:H p-i-n detectors with a wide range of intrinsic layer thickness between 2 and 10 pm. Such a large active layer thickness is required in applications like elementary particle detectors or X-ray detectors. For large thickness and depending on the applied bias, we observe a sharp peak in the spectral response in the red region near 700 nm. Simulation results obtained with the program ASCA are in agreement with the measurement and permit the explanation of the experimental data. In thick samples holes recombine or are trapped before reaching the contacts, and the conduction mechanism is fully electron dominated. As a consequence, the peak position in the spectral response is located near the optical band gap of the a-Si:H i-layer. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
In this paper we present results on the use of a multilayered a-SiC:H heterostructure as a wavelength-division demultiplexing device (WDM) for the visible light spectrum. The WDM device is a glass/ITO/a-SiC:H (p-i-n)/ a-SiC:H(-p) /Si:H(-i)/SiC:H (-n)/ITO heterostructure in which the generated photocurrent at different values of the applied bias can be assigned to the different optical signals. The device was characterized through spectral response measurements, under different electrical bias. Demonstration of the device functionality for WDM applications was done with three different input channels covering wavelengths within the visible range. The recovery of the input channels is explained using the photocurrent spectral dependence on the applied voltage. The influence of the optical power density was also analysed. An electrical model, supported by a numerical simulation explains the device operation. Short range optical communications constitute the major application field, however other applications are also foreseen.
Resumo:
In studies assessing the effects of a given exposure variable and a specific outcome of interest, confusion may arise from the mistaken impression that the exposure variable is producing the outcome of interest, when in fact the observed effect is due to an existing confounder. However, quantitative techniques are rarely used to determine the potential influence of unmeasured confounders. Sensitivity analysis is a statistical technique that allows to quantitatively measuring the impact of an unmeasured confounding variable on the association of interest that is being assessed. The purpose of this study was to make it feasible to apply two sensitivity analysis methods available in the literature, developed by Rosenbaum and Greenland, using an electronic spreadsheet. Thus, it can be easier for researchers to include this quantitative tool in the set of procedures that have been commonly used in the stage of result validation.
Resumo:
A pi'n/pin a-SiC:H voltage and optical bias controlled device is presented and its behavior as image and color sensor, optical amplifier and demux device is discussed. The design and the light source properties are correlated with the sensor output characteristics. Different readout techniques are used. When a low power monochromatic scanner readout the generated carriers the transducer recognizes a color pattern projected on it acting as a direct color and image sensor. Scan speeds up to 10(4) lines per second are achieved without degradation in the resolution. If the photocurrent generated by different monochromatic pulsed channels is readout directly, the information is demultiplexed. Results show that it is possible to decode the information from three simultaneous color channels without bit errors at bit rates per channel higher than 4000 bps. Finally, when triggered by light of appropriated wavelength, it can amplify or suppress the generated photocurrent working as an optical amplifier (C) 2009 Published by Elsevier Ltd.
Resumo:
The objective of the study was to compare information collected through face-to-face interviews at first time and six years later in a city of Southeastern Brazil. In 1998, 32 mothers (N=32) of children aged 20 to 30 months answered a face-to-face interview with structured questions regarding their children's brushing habits. Six years later this same interview was repeated with the same mothers. Both interviews were compared for overall agreement, kappa and weighted kappa. Overall agreement between both interviews varied from 41 to 96%. Kappa values ranged from 0.00 to 0.65 (very bad to good) without any significant differences. The results showed lack of agreement when the same interview is conducted six years later, showing that the recall bias can be a methodological problem of interviews.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores.
Resumo:
Dissertação de Mestrado em Ciências Económicas e Empresariais.
Resumo:
Knowledge plays an important role in health care. The production and diffusion of health-related knowledge are increasingly under the control of private commercial interests, which are characterized by conflicts of interests that result in abuses of power. Considerable research has been done on the medical-industrial complex and its role in the production of power imbalances and the consequent abuses, but little attention has been dedicated to the role played by the publishing industry, which can be subject to the same problems. The widely diffused idea that "frequent and major changes" occur in medicine, albeit unsupported by clearcut evidence, is an effective marketing tool for both the pharmaceutical and publishing industries, who feed and thrive on physicians' insecurities. The production and distribution of knowledge should be addressed as a strategic component of public health.
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção do grau de Mestre em Ciências da Educação Especialidade em Didáctica das Ciências da Natureza
Resumo:
Neste artigo pretende-se reflectir sobre a importância da leitura de contos para o desenvolvimento moral e ético na infância. Partindo da confusão entre valores e opiniões e das dificuldades em educar para os valores num mundo anti-ético, comenta-se a relevância do ritual da ―Hora do Conto‖ – tanto à hora de dormir como durante o dia – e da terapia através dos contos. Defende-se ainda que a reflexão e a consciencialização que advêm da leitura de alguns contos – de que se sugerem exemplos – permitem a aquisição de referências sólidas no âmbito duma ―ética de salvaguarda‖: de si, dos outros, da natureza e do mundo.
Resumo:
Recensão crítica do livro "Innis, H.(2011[1951]) O viés da comunicação. Petropólis, Vozes".
Resumo:
Resenha do livro "Innis, H.(2011[1951]) O viés da comunicação. Petropólis, Vozes".