944 resultados para 3-DIMENSIONAL ULTRASOUND
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work we discuss the effect of the quartic fermion self-interaction of Thirring type in QED in D=2 and D=3 dimensions. This is done through the computation of the effective action up to quadratic terms in the photon field. We analyze the corresponding nonlocal photon propagators nonperturbatively in k/m, where k is the photon momentum and m the fermion mass. The poles of the propagators were determined numerically by using the MATHEMATICA software. In D=2 there is always a massless pole whereas for strong enough Thirring coupling a massive pole may appear. For D=3 there are three regions in parameter space. We may have one or two massive poles or even no pole at all. The interquark static potential is computed analytically in D=2. We notice that the Thirring interaction contributes with a screening term to the confining linear potential of massive two-dimensional QED (QED(2)). In D=3 the static potential must be calculated numerically. The screening nature of the massive QED(3) prevails at any distance, indicating that this is a universal feature of D=3 electromagnetic interaction. Our results become exact for an infinite number of fermion flavors.
Resumo:
The problem of confinement of spinless particles in 1 + 1 dimensions is approached with a linear potential by considering a mixing of Lorentz vector and scalar couplings. Analytical bound-states solutions are obtained when the scalar coupling is of sufficient intensity compared to the vector coupling. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The problem of confinement of fermions in 1 + 1 dimensions is approached with a linear potential in the Dirac equation by considering a mixing of Lorentz vector and scalar couplings. Analytical bound-states solutions are obtained when the scalar coupling is of sufficient intensity compared to the vector coupling. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
CONTEXTO E OBJETIVO: A biópsia da próstata não é um procedimento isento de riscos. Existe preocupação com respeito às complicações e quais seriam os melhores antibióticos usados antes do procedimento. O objetivo foi determinar a taxa de complicações e os possíveis fatores de risco para complicação na biópsia da próstata. TIPO DE ESTUDO E LOCAL: Estudo prospectivo clínico, realizado no Hospital das Clínicas de Botucatu. MÉTODOS: Foram realizadas biópsias em 174 pacientes que apresentavam anormalidade ao exame digital da próstata ou antígeno prostático específico maior que 4 ng/ml ou ambos. Todos os pacientes realizaram enema e antibioticoprofilaxia previamente ao exame. As complicações foram anotadas após o término do procedimento e em consultas posteriores. Algumas condições foram investigadas como possíveis fatores de risco para biópsias de próstata: idade, câncer da próstata, diabetes melito, hipertensão arterial sistêmica, antecedentes de prostatite, uso de ácido acetilsalicílico, volume prostático, número de biópsias e uso de sonda vesical. RESULTADOS: As complicações hemorrágicas foram mais comuns (75,3%) enquanto que as infecciosas ocorreram em 19% dos casos. O tipo mais freqüente foi a hematúria, ocorrendo em 56% dos pacientes. A infecção do trato urinário ocorreu em 16 pacientes (9,2%). Sepse foi observada em três pacientes (1,7%). Não houve óbitos. em 20% dos pacientes não foram observadas complicações após o exame. A presença da sonda vesical foi fator de risco para complicações infecciosas (p < 0,05). O número maior de amostras nas biópsias foi relacionado à hematúria, sangramento retal e complicações infecciosas (p < 0,05). As demais condições investigadas não se relacionaram com complicações pós-biópsia da próstata. CONCLUSÕES: As complicações pós-biópsia da próstata foram em sua maioria autolimitadas. A taxa de complicações graves foi baixa, sendo a biópsia de próstata guiada pelo ultra-som segura e eficaz. A retirada de um maior número de fragmentos na biópsia relaciona-se com hematúria, sangramento retal e complicações infecciosas. A sonda vesical foi um fator de risco para complicações infecciosas.
Resumo:
Purpose: To determine whether the use of ultrasound (US) to guide embryo transfer (ET) in a population previously defined as likely to have easy transfer would change the implantation and pregnancy rates in an ICSI program.Methods: A total of 100 patients identified as likely to have easy transfer after mock transfer were divided into two groups: Group I, US-guided ET (N = 50) and Group II, ET without the aid of US (N = 50).Results: Implantation and pregnancy rates were similar (p = 0.51, p = 0.29) for Group I (19.6%,42%) and Group II (16.3%,30%), as also was the abortion rate (p = 0.55) (Group I: 1/21; Group II: 2/15).Conclusion: As long as previous mock transfers are routinely performed during a cycle preceding assisted reproduction and the clinician considers transfer to be easy, ultrasound does not benefit the process of embryo transfer.
Resumo:
Background Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules.Methods In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into ultrasound'' and control'' groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained with hematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light.Results Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization.Conclusion The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.
Resumo:
Aims: Obsessivecompulsive disorder (OCD) also generates emotional burden in the patient's family members, but no study has evaluated the specific dimensions of burden. The objectives were to evaluate the dimensions of the Zarit Burden Interview (ZBI) and possible correlates. Methods: This was a cross-sectional study involving 47 patients and 47 caregivers, using a sociodemographic questionnaire; the ZBI; the Self Reporting Questionnaire; the Family Accommodation Scale; and the YaleBrown ObsessiveCompulsive Scale. The ZBI factor analysis was conducted using Varimax Rotation. Results: Six factors were identified, explaining 74.2% of the total variance: factor 1, interference in the caregiver's personal life (36.6% of the variance); factor 2, perception of patient's dependence (10.8%); factor 3, feelings of irritation or intolerance (9.2%); factor 4, guilt (7.2%); factor 5, insecurity (5.6%); and factor 6, embarrassment (4.8%). The six ZBI factors were associated with greater OCD severity and with greater accommodation to the patient's symptoms, and factors 1, 2, 5 and 6 with caregiver's psychological morbidity. Caregiver's sex (female) was associated with factors 5 and 6, relationship with the patient (being a parent or son/daughter) with factor 5, higher educational level with factor 6, living with the patient with factor 3, worse self-evaluation of health with factors 1, 5 and 6, and occupational status (not working) with factors 1, 2, 5 and 6. Conclusion: The dimensions of burden identified indicate the most affected aspects of a caregiver's life and could guide the planning of more specific interventions. Thus, the caregiver could participate more effectively in the OCD patient's treatment, with a lower impact on his/her life.
Resumo:
Purpose: The aim of this study was to assess the influence of cusp inclination on stress distribution in implant-supported prostheses by 3D finite element method.Materials and Methods: Three-dimensional models were created to simulate a mandibular bone section with an implant (3.75 mm diameter x 10 mm length) and crown by means of a 3D scanner and 3D CAD software. A screw-retained single crown was simulated using three cusp inclinations (10 degrees, 20 degrees, 30 degrees). The 3D models (model 10d, model 20d, and model 30d) were transferred to the finite element program NeiNastran 9.0 to generate a mesh and perform the stress analysis. An oblique load of 200 N was applied on the internal vestibular face of the metal ceramic crown.Results: The results were visualized by means of von Mises stress maps. Maximum stress concentration was located at the point of application. The implant showed higher stress values in model 30d (160.68 MPa). Cortical bone showed higher stress values in model 10d (28.23 MPa).Conclusion: Stresses on the implant and implant/abutment interface increased with increasing cusp inclination, and stresses on the cortical bone decreased with increasing cusp inclination.