941 resultados para urine incontinence
Resumo:
The performance of an amperometric biosensor constructed by associating tyrosinase (Tyr) enzyme with the advantages of a 3D gold nanoelectrode ensemble (GNEE) is evaluated in a flow-injection analysis (FIA) system for the analysis of l-dopa. GNEEs were fabricated by electroless deposition of the metal within the pores of polycarbonate track-etched membranes. A simple solvent etching procedure based on the solubility of polycarbonate membranes is adopted for the fabrication of the 3D GNEE. Afterward, enzyme was immobilized onto preformed self-assembled monolayers of cysteamine on the 3D GNEEs (GNEE-Tyr) via cross-linking with glutaraldehyde. The experimental conditions of the FIA system, such as the detection potential (−0.200 V vs. Ag/AgCl) and flow rates (1.0 mL min−1) were optimized. Analytical responses for l-dopa were obtained in a wide concentration range between 1 × 10−8 mol L−1 and 1 × 10−2 mol L−1. The limit of quantification was found to be 1 × 10−8 mol L−1 with a resultant % RSD of 7.23% (n = 5). The limit of detection was found to be 1 × 10−9 mol L−1 (S/N = 3). The common interfering compounds, namely glucose (10 mmol L−1), ascorbic acid (10 mmol L−1), and urea (10 mmol L−1), were studied. The recovery of l-dopa (1 × 10−7 mol L−1) from spiked urine samples was found to be 96%. Therefore, the developed method is adequate to be applied in the clinical analysis.
Resumo:
A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.
Resumo:
Pesticide exposure during brain development could represent an important risk factor for the onset of neurodegenerative diseases. Previous studies investigated the effect of permethrin (PERM) administered at 34 mg/kg, a dose close to the no observable adverse effect level (NOAEL) from post natal day (PND) 6 to PND 21 in rats. Despite the PERM dose did not elicited overt signs of toxicity (i.e. normal body weight gain curve), it was able to induce striatal neurodegeneration (dopamine and Nurr1 reduction, and lipid peroxidation increase). The present study was designed to characterize the cognitive deficits in the current animal model. When during late adulthood PERM treated rats were tested for spatial working memory performances in a T-maze-rewarded alternation task they took longer to choose for the correct arm in comparison to age matched controls. No differences between groups were found in anxiety-like state, locomotor activity, feeding behavior and spatial orientation task. Our findings showing a selective effect of PERM treatment on the T-maze task point to an involvement of frontal cortico-striatal circuitry rather than to a role for the hippocampus. The predominant disturbances concern the dopamine (DA) depletion in the striatum and, the serotonin (5-HT) and noradrenaline (NE) unbalance together with a hypometabolic state in the medial prefrontal cortex area. In the hippocampus, an increase of NE and a decrease of DA were observed in PERM treated rats as compared to controls. The concentration of the most representative marker for pyrethroid exposure (3-phenoxybenzoic acid) measured in the urine of rodents 12 h after the last treatment was 41.50 µ/L and it was completely eliminated after 96 h.
Resumo:
A eritropoietina (EPO) é uma substância que estimula a produção de eritrócitos, aumentando a oxigenação muscular, sendo segregada de forma natural pelo organismo e excretada na urina em baixas concentrações. Devido às suas propriedades e características, a EPO foi rapidamente introduzida no mundo do desporto, como substância ilícita, proporcionando vantagens no rendimento desportivo. No início de 2000 foi desenvolvido um método de deteção direta de EPO Recombinante (rHuEPO) em urina humana por Lasne, baseado na focalização isoelétrica (IEF) em gel de poliacrilamida, seguido de duplo blote, tendo este sido publicado e validado. Em 2002, a Agência Mundial Antidopagem (AMA) implementou este mesmo método, sendo atualmente um dos métodos oficiais utilizado pelos laboratórios acreditados pela AMA. Desta forma, o ponto de partida para a realização deste trabalho consistiu na necessidade de implementar e validar o método de referência de IEF para a deteção de rHuEPO em urina humana. O trabalho foi realizado no Laboratório de Análises e Dopagem (LAD) do Instituto do Desporto de Portugal (IDP), atual Instituto Português do Desporto e Juventude (IPDJ). O principal objetivo deste trabalho consistiu no estudo/investigação de diferentes parâmetros de validação (especificidade/seletividade; capacidade de identificação; limite de deteção; exatidão e repetibilidade), de acordo com o protocolado no Procedimento Geral interno do Laboratório de Análises de Dopagem de Lisboa (LAD). O referido método de triagem e confirmação revelou possuir características de desempenho conformes com os requisitos aplicáveis, pelo que é considerado validado e apto.
Resumo:
Resumo Uma estratégia de avaliação e prevenção de riscos na exposição a agentes químicos deve ter sempre em conta que a vigilância do ambiente de trabalho e a da saúde dos trabalhadores são aspectos complementares de uma mesma realidade – os riscos resultantes da interacção entre um agente químico e os trabalhadores a ele expostos. Se à Vigilância Ambiental compete apreciar o risco, pela caracterização do agente no ambiente de trabalho, a Vigilância Biológica pronuncia-se sobre a interacção entre o tóxico e o organismo, avaliando a resposta à agressão química e a evolução das reacções de adaptação ou de desajuste face à absorção do tóxico. Os Indicadores Biológicos, deste modo, assumem um estatuto de instrumento privilegiado na vigilância da saúde dos trabalhadores expostos, na medida em que medem a quantidade de tóxico que efectivamente penetrou e foi absorvido, ou o resultado (efeito) determinado por essa mesma dose. O presente estudo procura contribuir para a definição de um quadro metodológico de utilização dos Indicadores Biológicos na avaliação/gestão da exposição profissional ao chumbo, designadamente apreciando a variação da protoporfirina-zinco (PPZ), indicador até ao presente ainda não utilizado em Portugal. O chumbo é um metal de ocorrência natural, cujos níveis nos diversos ecossistemas resultam, principalmente, das actividades antropogénicas de natureza doméstica e industrial. A sua capacidade poluente é assinalável, representando uma fonte de exposição permanente para o homem, demonstrável pela sua constante presença no organismo apesar de não desempenhar qualquer tipo de função fisiológica. São actualmente inúmeras as suas aplicações, tornando a exposição profissional ao chumbo uma realidade vasta: indústrias de acumuladores eléctricos, de vidros, de plásticos e de munições, construção civil, manutenção e reparação automóvel e de navios, fabrico de tintas, indústrias electrónicas, fundições e actividades de soldadura são, entre outras, situações onde é uma realidade a ter em conta. A penetração dos compostos inorgânicos de chumbo no organismo efectua-se principalmente por via respiratória, não sendo, no entanto, desprezável, a sua penetração por via digestiva. As partículas absorvidas são transportadas pelo sangue principalmente ligadas aos eritrocitos (95%), distribuem-se pelos tecidos moles e depositam-se essencialmente no tecido ósseo, onde representam mais de 90% da carga corporal do total absorvido e tendo aí um elevado tempo de semi-vida (mais de 20 anos). Não é metabolizado no organismo e a sua eliminação efectua-se essencialmente por via renal,sendo igualmente excretado, em menor escala, através das fezes, do suor, da saliva, das faneras e do leite materno. O conhecimento científico evidencia que concentrações sanguíneas de chumbo entre 20 e 50 mg/dL são susceptíveis de determinar efeitos adversos no homem, podendo ser afectados o sistema hematopoiético, o sistema nervoso, o sistema cardiovascular, o sistema reprodutor e o sistema imunitário. Contudo, ainda muito há a clarificar no âmbito da toxicidade do chumbo. Os níveis de exposição a que correspondem as alterações nos diversos órgãos e sistemas continuam a ser motivo de alguma controvérsia. As características carcinogénicas e mutagénicas do chumbo são, ainda, um campo de vasta exigência de investigação. A intoxicação por chumbo e seus sais (Saturnismo) de origem ocupacional é reconhecida em Portugal como doença profissional (grupo 1 - Doenças Provocadas por Agentes Químicos, da Lista das Doenças Profissionais). É uma intoxicação do tipo crónico, fruto da absorção contínua de doses relativamente pequenas durante longo período, evidenciando-se no seu início por sinais e sintomas vagos e difusos de grande inespecificidade, que podem incluir, nomeadamente, perda de apetite, sabor metálico na boca, palidez, mal-estar e fadiga, cefaleias, mialgias e artralgias, irritabilidade, tremores finos, obstipação, cólicas abdominais, insónias, déficit da memória de curto prazo e da capacidade de concentração. Um importante conjunto de indicadores biológicos pode ser utilizado na vigilância periódica da saúde de trabalhadores nestas condições de exposição. Tais indicadores (de dose ou de efeito), encerram diferentes significados e comportam distintas exigências, competindo ao Médico do Trabalho, no âmbito dos programas de prevenção dos efeitos adversos relacionados com a exposição profissional a chumbo, seleccionar a sua utilização e interpretar a sua informação, de modo a avaliar a interacção do tóxico com o organismo numa fase de reversibilidade. O presente estudo envolveu 180 trabalhadores dos quais 110 apresentavam plumbémias (Pb-S) iguais ou superiores a 40 mg/dL. Além da Pb-S, a todos foi doseada a protoporfirina-zinco (PPZ) e efectuado o Hemograma e a cerca de 25% foi determinada a concentração do ácido d-aminolevulínico urinário (ALA-U). Os doseamentos da PPZ efectuados em amostra de sangue capilar através de um hematofluorímetro portátil revelaram-se de total fiabilidade, dando significado a uma técnica de fácil execução e baixo custo. A avaliação do tipo de colheita urinária para doseamento do ALA-U concluiu pela necessidade de recurso a urinas de 24 horas.Os resultados do estudo evidenciaram uma elevada associação entre a PPZ e a Pb-S, com uma maior magnitude e de início mais precoce do que o que registado na associação da Pb-S com o ALA-U. Revelaram, ainda, fracos níveis de associação da hemoglobina (e outros parâmetros hematológicos) com a Pb-S. E demonstraram para um cut-off de 100 mg/ dL de PPZ, taxa de falsos negativos e falsos positivos, para plumbémias a partir de 70 mg/dL, inferiores a 20%. Assim, concluiu-se que, nos protocolos de vigilância de saúde de trabalhadores expostos a chumbo, o doseamento da PPZ por hematofluorímetro, em sangue de colheita capilar, é adequado, fiável e de realização preferencial em relação ao do ALA-U. Concluiu-se, também, que a realização do hemograma apenas se justifica em situações individuais que clinicamente o tornem aconselhável. E que estes protocolos devem incluir a realização da Pb-S e da PPZ, podendo, em situações de controlo rigoroso (ambiental, biológico e clínico), basear-se apenas na determinação da PPZ reservando os outros indicadores para aprofundar a investigação médica nos casos de taxas elevadas desta ou de situações limitantes. ■ Résumée Une stratégie d’évaluation et de prévention des risques d’exposition aux agents chimiques doit toujours tenir en considération que la vigilance du lieu de travail et de la santé des travailleurs sont des aspects complémentaires d’une même réalité – les risques résultant d’une interaction entre l’agent chimique et les travailleurs exposés. Si c’est à la Vigilance Ambiantale de juger le risque, par la caractérisation de l’agent dans le lieu de travail, la Vigilance Biologique, elle, se prononce sur l’interaction entre le toxique et l’organisme, évaluant la réponse à l’agression chimique et l’évolution des réactions d’adaptation ou de rupture face à l’absorption du toxique. Les Indicateurs Biologiques assument ainsi un statut d’instrument privilégié de vigilance de la santé des travailleurs exposés, dans la mesure où ils déterminent la quantité de toxique qui a effectivement été pénétré et absorbé, ou le résultat (effet) déterminé par cette dose. Cette étude-ci cherche à contribuer à la définition d’un cadre méthodologique d’utilisation des Indicateurs Biologiques dans l’évaluation/ gestion de l’exposition professionnelle au plomb inorganique, évaluant spécialement le comportement de la protoporphirine-zinc (PPZ), indicateur pas encore utilisé au Portugal.Le plomb est un métal d’occurrence naturelle dont les niveaux dans les différents écosystèmes en résultent, principalement, des activités anthropogéniques de nature domestique et industrielle. Sa capacité polluante peut être signalée, représentant une source d’exposition permanente pour l’homme, celle-ci démontrable par sa présence continue dans l’organisme, même si elle n’y accomplit aucune fonction physiologique. Actuellement ses applications sont innombrables, faisant de l’exposition professionnelle au plomb une réalité de grande ampleur : industries d’accumulateurs électriques, de verre, de plastique et de munitions, bâtiments, manutention et réparation automobile et navale, fabrication d’encres, industries électroniques, fontes et activités de soudure sont, entre autres, des situations réelles a en tenir compte. La pénétration du plomb inorganique dans l’organisme se fait principalement par voie respiratoire, pouvant se faire également par voie digestive. Les particules absorbées sont transportées par le sang, surtout liées aux érythrocytes (95%), se repartent à travers les tissus mous et se déposent essentiellement dans le tissu osseux, où elles représentent plus de 90% de la charge corporelle de ce qui a été absorbé et ont un temps de demi-vie élevé (plus de 20 ans). Le plomb n’est pas métabolisé dans l’organisme et son élimination se fait essentiellement par voie rénale, pouvant tout de même, à une moindre échelle, être excrété dans les fèces, de la sueur, de la salive, des ongles, des cheveux et du lait maternel. La connaissance scientifique met en évidence que des concentrations sanguines de plomb entre 20 et 50 mg/dL sont susceptibles de déterminer des effets adverses dans l’homme, pouvant les systèmes hématopoïétique, nerveux, cardiovasculaire, reproducteur et immunitaire en être affectés. Cependant, il en reste beaucoup à éclaircir dans le domaine de la toxicité du plomb. Les niveaux d’exposition auxquels correspondent les modifications des divers organes et systèmes, demeurent toujours sujet de quelque controverse. Les caractéristiques carcinogèniques et mutagèniques du plomb restent toujours un champ d’investigation d’une grande exigence. L’intoxication par le plomb et ses sels (Saturnisme) d’origine occupationnelle est reconnue, au Portugal, comme une maladie professionnelle (groupe 1- Maladies Provoquées par des Agents Chimiques, de la Liste des Maladies Professionnelles). C’est une intoxication du tipe chronique, due à l’absorption continue de doses relativement petites pendant une longue période, mise en évidence à travers des signes et des symptômes vagues et diffus sans grande spécificité, lesquels peuvent inclure, particulièrement, le manque d’appétit, goût métallique dans la bouche, pâleur, malaise et fatigue, céphalées, myalgies et arthralgies, irritabilité, tremblements fins, constipation, coliques abdominales, insomnies, déficit de la mémoire à court terme et de la capacité de concentration.Un ensemble important d’indicateurs biologiques peut être employé dans la vigilance périodique de la santé des travailleurs dans ces conditions d’exposition. Ces indicateurs (de dose ou d’effet) renferment différentes significations et comportent diverses exigences, devant le Médecin de Travail, dans le domaine des programmes de prévention des effets adverses qui sont en relation avec l’exposition professionnelle au plomb, sélectionner son utilisation et interpréter son information de façon à évaluer l’interaction de l’élément toxique avec l’organisme à un stade de réversibilité. L’étude ci-présent engloba 180 travailleurs desquels 110 présentaient des plombémies (Pb-S) égales ou supérieures à 40 mg/dL. À part la Pb-S, la protoporphyrine-zinc (PPZ) leur a été prise en dosage et un Hémogramme fut effectué et fut déterminé l’acide d- aminolévulinique urinaire (ALA-U) sur environ 25% des travailleurs. Le dosage de la PPZ efectué en échantillon de sang capillaire par un fluorimètre portable, s’est accomplit d’une fiabilité total, donnant du sgnificat à une téchnique de facile execution et bas prix. L’évaluation de la prise urinaire par dosage du ALA-U conclut au besoin d’un recours aux urines de 24 heures Les résultats de l’étude ont mis en évidence une association élevée entre la PPZ et la Pb- S, avec une intensité majeure et de début plus précoce par rapport à celui qui fut registré lors de l’association de la Pb-S avec la ALA-U. Ces résultats ont également montré de faibles niveaux d’association entre l’hémoglobine (et autres paramètres hématologiques) et la Pb-S. Ils ont démontré aussi, une valeur de cut-off de 100 mg/dL de PPZ, des taux de faux négatifs et faux positifs, pour des plombémies de 70 mg/dL, inférieurs à 20%. On peut donc conclure que dans les protocoles de vigilance de la santé des travailleurs exposés au plomb, le dosage de la PPZ par fluorimetrie dans le sang capillaire est adéquat, fiable et de réalisation préférentielle par rapport à celui du ALA-U. On peut également conclure que la réalisation de l’hémogramme ne se justifie que dans les cas individuels où, cliniquement, celui-ci est conseillé. De plus, ces protocoles doivent inclure la réalisation de la Pb-S et de la PPZ, pouvant, en cas de contrôle rigoureux (ambiantal, biologique et clinique), s’appuyer que dans la détermination de la PPZ réservant les autres indicateurs pour approfondir l’investigation médicale dans les cas où les taux de celle-ci sont élevés ou dans les cas de situations limitantes. ■ Summary Any strategy to evaluate and prevent the risks of chemical agents exposure must always regard the work environment and workers health as complementary aspects of one reality - the resulting risks from the interaction between the chemical agent and the exposed workers. It is the responsibility of Environmental Monitoring to evaluate the risks of exposure by the characterization of the chemical agent in the work environment. Biological Monitoring, on the other hand, pronounces itself over the toxin and body interaction, evaluating human response to the chemical aggression and the body adaptations to the toxic absorption. Biological Exposure Indices (BEI) assume, therefore, a privileged status among exposed workers' health monitoring instruments, as they measure the actual penetrated and absorbed toxic quantity and the effect it produces. This research study aims to contribute to the definition of a methodological strategy on the utilization of BEI’s in evaluating inorganic lead's occupational exposure, more specifically appreciating the zinc protoporphyrin (ZPP) variation, an index that has never been taken under consideration in Portugal until now. Lead is a natural metal whose ecosystem’s levels are mainly due to domestic and industrial anthropogenic activities. Its pollutant capacity is notable, representing a permanent exposure risk shown by its constant presence in the human body, although it has no physiologic function. Nowadays, lead's applications are countless, turning its professional exposure a huge reality: storage batteries industries, glass industries, plasterers and munitions industries, building construction, ships and motor car maintenance and repairing, ink manufacture, electronics industries, foundries and other soldering activities are, among so many other, realities to attend to. Respiration is the main cause of human body's inorganic lead absorption, although digestive pathway must not to be ignored. The absorbed particles are transported by blood, essentially bounded to erythrocytes (95%). It is distributed by soft tissues and settled mainly on bone tissues, where it represents approximately 90% of the total body charge and has a high half-life time (more than 20 years). It is not metabolized by the organism, its elimination being effectuated by renal activity and, in smaller scale, through lees, sweat, saliva, nails, hair and maternal milk.Scientific knowledge shows that concentrations of lead in blood between 20 e 50 mg/dL are susceptible to determine adverse effects in man and able to affect the hematopoietic system, the nervous system, the cardiovascular system, the reproductive system and the immunological system. Nevertheless, there's still much to be learned and clarified about lead's toxicity. The correlation between exposure levels and human's systems and organs alteration levels continues to be a centre of controversies. Still, lead's carcinogenic and mutagenic characteristics continue to be a high demanding research field. Intoxication by lead and its compounds (saturnism), from occupational origin, is recognized in Portugal as an occupational disease, included in Group 1 - Chemical Agents Caused Diseases, on the Occupational Diseases List. It is a chronic intoxication caused by a continuous absorption of small doses, throughout a long period of time. Its signs and symptoms are diffuse and imprecise, of great unspecificity, such as loss of appetite, metallic flavor in the mouth, paleness, ailment and fatigue, headaches, myalgia and arthralgia, irritability, thin tremors, constipation, abdominal pain, insomnias, short memory loses and inability to concentrate. A considered number of BEI’s can be used in Periodic Health Monitoring of workers in such exposure conditions. Such BEI (dose indices or effect indices) provide different meanings and imply different procedures, being Occupational Doctors responsibility, in the context of lead related adverse effects preventive programmes, to select and interpret its information, in order to evaluate the interaction between toxic and organism in a reversible phase of the toxic action. The present research study involved 180 workers, 110 of which presented blood lead levels (PbB) above or equal to 40 mg/dL. Besides PbB, all workers has been evaluated for zinc protoporphyrin levels (PPZ) and submitted to a haemogram. About 25% of the workers were selected for d-aminolevulinic urinary acid (ALA-U) determination. The evaluation of PPZ, by a portable hematofluorometer using capillary blood samples, turned out to be an easy procedure with low costs and total warrantability. As in regard for ALA- U procedure, it was concluded the necessity of 24 hours urine samples. This research results underlined a strong connection between ZPP and PbB, which was found to to be stringer and to begin earlier than it was registered for PbB and ALA-U association. The same study also revealed a low association level between PbB and hemoglobin or other hematological indices. It was also verified less than 20% of false negatives and false positives cases when admitted a ZPP 100 mg/dL cut off value for PbB³ 70 mg/dL. As in result it was concluded that in Health Monit
Resumo:
Introdução: Os exercícios de fortalecimento dos músculos do pavimento pélvico (EFMPP) são considerados a primeira intervenção no tratamento da incontinência urinária de esforço (IUE), porém os EFMPP são distintos, não existindo evidência sobre os parâmetros de treino. Objetivo: Identificar o protocolo e/ ou os parâmetros de treino dos músculos do pavimento pélvico (MPP) mais eficaz no tratamento da IUE feminina. Método: A pesquisa bibliográfica foi realizada entre janeiro de 1992 a março de 2014 nas bases de dados PubMed, Cochrane Library, PEDro, web of Science e LILACS. Os artigos incluídos eram de língua inglesa, estudos experimentais, no qual comparavam EFMPP com o tratamento placebo, usual ou sem tratamento, com idade compreendida entre os 18 e os 65 anos e diagnóstico de IUE. Os critérios de exclusão abrangeram o diagnóstico de IUE desencadeada por fatores externos ao trato urinário inferior, grávidas, puérperas, prolapso ≥ 2 e outros tipos de IU. A avaliação da qualidade metodológica for realizada através da escala PEDro. Resultados: Sete artigos de elevada qualidade metodológica foram incluídos na presente revisão. A amostra foi constituída por 331 mulheres, com idade média de 44,4 anos, duração média das perdas urinárias de 64 meses e a gravidade da IUE variou entre ligeira a severa. Os programas de EFMPP eram distintos em relação aos parâmetros de treino dos MPP, sendo que alguns estudos incluíram o treino abdominal, supervisão e técnicas adjuvantes. A taxa de curada da quantidade de perda urinária variou entre 28,6 a 80%, enquanto a força dos MPP variou de 15,6% a 161,7%. Conclusão: Na presente revisão sistemática, os EFMPP combinados com palpação digital, biofeedback e cones vaginais parecem ser mais eficazes na redução da quantidade de perda urinária, comparado com os EFMPP isolados ou sem tratamento. Esta revisão permitiu igualmente identificar as 12 semanas de duração da intervenção, 10 repetições por série e diferentes posições, sendo os parâmetros de treino mais consistentes na redução dos sintomas.
Resumo:
O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.
Resumo:
Este trabalho descreve o desenvolvimento de um material sensor para creatinina por impressão molecular em estrutura polimérica (MIP) e a sua aplicação no desenvolvimento de um dispositivo de natureza potenciométrica para a determinação da molécula alvo em fluidos biológicos. A creatinina é um dos biomarcadores mais utilizados no acompanhamento da doença renal, já que é um bom indicador da taxa de filtração glomerular (TFG). Os materiais biomiméticos desenhados para interação com a creatinina foram obtidos por polimerização radicalar, recorrendo a monómeros de ácido metacríclico ou de vinilpiridina e a um agente de reticulação apropriado. De modo a aferir o efeito da impressão da creatinina na resposta dos materiais MIP à sua presença, foram também preparados e avaliados materiais de controlo, obtidos sem impressão molecular (NIP). O controlo da constituição química destes materiais, incluindo a extração da molécula impressa, foi realizado por Espectroscopia de Raman e de Infravermelho com Transformada de Fourrier. A afinidade de ligação entre estes materiais e a creatinina foi também avaliada com base em estudos cinéticos. Todos os materiais descritos foram integrados em membranas selectivas de elétrodos seletivos de ião, preparadas sem ou com aditivo iónico lipófilo, de carga negativa ou positiva. A avaliação das características gerais de funcionamento destes elétrodos, em meios de composição e pH diferentes, indicaram que as membranas com materiais impressos e aditivo aniónico eram as únicas com utilidade analítica. Os melhores resultados foram obtidos em solução tampão Piperazine-N,N′-bis(2- ethanesulfonic acid), PIPES, de pH 2,8, condição que permitiu obter uma resposta quasi-Nernstiana, a partir de 1,6×10-5 mol L-1. Estes elétrodos demonstraram ainda uma boa selectividade ao apresentaram uma resposta preferencial para a creatinina quando na presença de ureia, carnitina, glucose, ácido ascórbico, albumina, cloreto de cálcio, cloreto de potássio, cloreto de sódio e sulfato de magnésio. Os elétrodos foram ainda aplicados com sucesso na análise de amostras sintéticas de urina, quando os materiais sensores eram baseados em ácido metacrilico, e soro, quando os materiais sensores utilizados eram baseados em vinilpiridina.
Resumo:
As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.
Resumo:
A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.
Resumo:
Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.
Resumo:
XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry
Resumo:
Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.
Resumo:
A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.
Resumo:
Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.