974 resultados para Hyperelliptic Curve


Relevância:

10.00% 10.00%

Publicador:

Resumo:

GOALS OF WORK: Recent literature has indicated the need for rapid evaluation of psychosocial issues secondary to cancer. Because of the problems of routine use of psychometric instruments, short instruments such as visual analogue scales or one-item 0-10 scales have been developed as valid assessment alternatives. PATIENTS AND METHODS: A study was conducted to examine the role of two 0-10 scales in measuring emotional stress (distress thermometer, DT) and depressed mood (mood thermometer, MT), respectively, in a multicenter study carried out in southern European countries (Italy, Portugal, Spain, and Switzerland). A convenience sample of 312 cancer outpatients completed the DT and MT and the Hospital Anxiety Depression Scale (HADS). MAIN RESULTS: DT was more significantly associated HADS anxiety than HADS depression while MT was related both to HADS anxiety and depression. The correlation of MT with HADS was higher than DT. A cutoff point >4 on the DT maximized sensitivity (65%) and specificity (79%) for general psychosocial morbidity while a cutoff >5 identified more severe "caseness" (sensitivity=70%; specificity=73%). On the MT, sensitivity and specificity for general psychosocial morbidity were 85% and 72% by using the cutoff score >3. A score >4 on the MT was associated with a sensitivity of 78% and a specificity of 77% in detecting more severe caseness. CONCLUSIONS: Two simple instruments, the DT and the MT, were found to have acceptable levels of sensitivity and specificity in detecting psychosocial morbidity. Compared to the HADS, however, the mood MT performed better than the DT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The introduction of new procedures in surgery usually implies the costs of the so called learning curve. However patients should not suffer the negative effects of surgeon's learning curves. We report our results with the first 15 Ross procedures, a single surgeon and institution experience, and how it was possible to build a safe learning curve without major consequences for the patients. We emphasize the need for a continuous program of surgical performance assessment throughout the learning curve period, as was demonstrated in our series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Desde sempre o Homem procurou automatizar tarefas repetitivas. Tanto na indústria como no sector doméstico ou de comércio estão constantemente a surgir novos equipamentos procurando aumentar o nível de automação de diversas tarefas. A necessidade de empresas criadoras de produtos inovadores se manterem concorrenciais obrigou à adopção de métodos de projecto e planeamento mais estruturados e eficientes que eliminem os desperdícios tanto de material como de tempo. Diversas construções em termos orçamentais e o aumento da procura de produtos de alta qualidade a baixo custo deu origem a um novo tipo de programas, os programas de simulação virtual. Tal como na indústria, também na investigação nas Instituições de Ensino Superior se procuram adoptar os métodos de trabalho mais eficientes possíveis. Uma parte dos programas de simulação robótica utilizados hoje em dia na investigação no Instituto Superior de Engenharia do Porto estão concebidos em linguagem C. Embora esta linguagem seja extremamente capaz, existem métodos mais adequados de simulação que aceleram o processo de modelação permitindo a visualização do movimento e simulação de diversas situações potencialmente criticas sem existir a necessidade de construção de um protótipo funcional do robô. Durante o último ano, este projecto permitiu construir um modelo de um robô quadrúpede num programa de simulação virtual chamado Simmechanics™. Embora haja já algum trabalho desenvolvido nesta área, constatou-se que a informação existente possuía algumas lacunas. Com o trabalho desenvolvido preparou-se esta dissertação que pretende clarificar algumas questões que surgem na modelação de um robô. Neste documento explica-se como modelar um robô de corpo flexível, modelar as pernas e as respectivas juntas da anca e do joelho assim como também se apresenta a modelação de um contacto com o solo recorrendo a um modelo descrito na literatura. Este documento foi escrito a pensar no leitor, procurando-se explicar de forma simples mas concisa os diversos passos necessários para construir um modelo virtual de um robô. O autor espera, desta forma, ajudar futuros colegas que pretendam trabalhar com o Simmechanics™ a mais facilmente se integrarem com o programa aumentando desta forma o declive da curva de aprendizagem e permitindo um maior aproveitamento desta ferramenta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study a citrate-buffered version of QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method for determination of 14 organochlorine pesticides (OCPs) residues in tamarind peel, fruit and commercial pulp was optimized using gas chromatography (GC) coupled with electron-capture detector (ECD) and confirmation by GC tandem mass spectrometry (GC–MS/MS). Five procedures were tested based on the original QuEChERS method. The best one was achieved with increased time in ultrasonic bath. For the extract clean-up, primary secondary amine (PSA), octadecyl-bonded silica (C18) and magnesium sulphate (MgSO4) were used as sorbents for tamarind fruit and commercial pulp and for peel was also added graphitized carbon black (GCB). The samples mass was optimized according to the best recoveries (1.0 g for peel and fruit; 0.5 g for pulp). The method results showed the matrix-matched calibration curve linearity was r2 > 0.99 for all target analytes in all samples. The overall average recoveries (spiked at 20, 40 and 60 μg kg−1) have been considered satisfactory presenting values between 70 and 115% with RSD of 2–15 % (n = 3) for all analytes, with the exception of HCB (in peel sample). The ranges of limits of detection (LOD) and quantification (LOQ) for OCPs were for peel (LOD: 8.0–21 μg kg−1; LOQ: 27–98 μg kg−1); for fruit (LOD: 4–10 μg kg−1; LOQ: 15–49 μg kg−1) and for commercial pulp (LOD: 2–5 μg kg−1; LOQ: 7–27 μg kg−1). The method was successfully applied in tamarind samples being considered a rapid, sensitive and reliable procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The adhesive bonding technique enables both weight and complexity reduction in structures that require some joining technique to be used on account of fabrication/component shape issues. Because of this, adhesive bonding is also one of the main repair methods for metal and composite structures by the strap and scarf configurations. The availability of strength prediction techniques for adhesive joints is essential for their generalized application and it can rely on different approaches, such as mechanics of materials, conventional fracture mechanics or damage mechanics. These two last techniques depend on the measurement of the fracture toughness (GC) of materials. Within the framework of damage mechanics, a valid option is the use of Cohesive Zone Modelling (CZM) coupled with Finite Element (FE) analyses. In this work, CZM laws for adhesive joints considering three adhesives with varying ductility were estimated. The End-Notched Flexure (ENF) test geometry was selected based on overall test simplicity and results accuracy. The adhesives Araldite® AV138, Araldite® 2015 and Sikaforce® 7752 were studied between high-strength aluminium adherends. Estimation of the CZM laws was carried out by an inverse methodology based on a curve fitting procedure, which enabled a precise estimation of the adhesive joints’ behaviour. The work allowed to conclude that a unique set of shear fracture toughness (GIIC) and shear cohesive strength (ts0) exists for each specimen that accurately reproduces the adhesive layer’ behaviour. With this information, the accurate strength prediction of adhesive joints in shear is made possible by CZM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Evaluate the sensitivity/specificity of immunoperoxidase method in comparison with the standard immunofluorescence. MATERIAL AND METHODS: Retrospective review of 87 biopsies made for allograft dysfunction. Immunofluorescence (IF) was performed in frozen allograft biopsies using monoclonal antibody anti-C4d from Quidel®. The indirect immunoperoxidase (IP) technique was performed in paraffin-embebbed tissue with polyclonal antiserum from Serotec®. Biopsies were independently evaluated by two nephropathologist according Banff 2007 classification. RESULTS: By IF, peritubular C4d deposition were detected in 60 biopsies and absent in 27 biopsies. The evaluation of biopsy by IP was less precise due to the presence of background and unspecific staining. We find 13.8% (12/87) of false negative and Banff classification concordance in 79.3% (69/87) of cases (table1). The ROC curve study reveal a specificity of 100% and sensitivity of 80.0 % of IP method in relation to the gold standard (area under curve:0.900; 95% Confidence interval :0.817-0.954; p=0.0001). Banff Classification C4d Cases Immunofluorescence Immunoperoxidase n =87 Diffuse Negative 3 (3.4%) Focal Negative 9 (10.3%) Negative Negative 27 (31.0%) Diffuse Diffuse 33 (37.9%) Focal Focal 9 (10.3%) Diffuse Focal 6 (6.9%) CONCLUSION: The IP method presents a good specificity, but lesser sensitivity to C4d detection in allograft dysfunction. The evaluation is more difficult, requiring more experience of the observer than IF method. If frozen tissue is unavailable, the use of IP for C4d detection is acceptable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Container Loading Problem (CLP) literature has traditionally evaluated the dynamic stability of cargo by applying two metrics to box arrangements: the mean number of boxes supporting the items excluding those placed directly on the floor (M1) and the percentage of boxes with insufficient lateral support (M2). However, these metrics, that aim to be proxies for cargo stability during transportation, fail to translate real-world cargo conditions of dynamic stability. In this paper two new performance indicators are proposed to evaluate the dynamic stability of cargo arrangements: the number of fallen boxes (NFB) and the number of boxes within the Damage Boundary Curve fragility test (NB_DBC). Using 1500 solutions for well-known problem instances found in the literature, these new performance indicators are evaluated using a physics simulation tool (StableCargo), replacing the real-world transportation by a truck with a simulation of the dynamic behaviour of container loading arrangements. Two new dynamic stability metrics that can be integrated within any container loading algorithm are also proposed. The metrics are analytical models of the proposed stability performance indicators, computed by multiple linear regression. Pearson’s r correlation coefficient was used as an evaluation parameter for the performance of the models. The extensive computational results show that the proposed metrics are better proxies for dynamic stability in the CLP than the previous widely used metrics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective Public health organizations recommend that preschool-aged children accumulate at least 3 h of physical activity (PA) daily. Objective monitoring using pedometers offers an opportunity to measure preschooler's PA and assess compliance with this recommendation. The purpose of this study was to derive step-based recommendations consistent with the 3 h PA recommendation for preschool-aged children. Method The study sample comprised 916 preschool-aged children, aged 3 to 6 years (mean age = 5.0 ± 0.8 years). Children were recruited from kindergartens located in Portugal, between 2009 and 2013. Children wore an ActiGraph GT1M accelerometer that measured PA intensity and steps per day simultaneously over a 7-day monitoring period. Receiver operating characteristic (ROC) curve analysis was used to identify the daily step count threshold associated with meeting the daily 3 hour PA recommendation. Results A significant correlation was observed between minutes of total PA and steps per day (r = 0.76, p < 0.001). The optimal step count for ≥ 3 h of total PA was 9099 steps per day (sensitivity (90%) and specificity (66%)) with area under the ROC curve = 0.86 (95% CI: 0.84 to 0.88). Conclusion Preschool-aged children who accumulate less than 9000 steps per day may be considered Insufficiently Active.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Peritubular capillary complement 4d staining is one of the criteria for the diagnosis of antibody-mediated rejection, and research into this is essential to kidney allograft evaluation. The immunofluorescence technique applied to frozen sections is the present gold-standard method for complement 4d staining and is used routinely in our laboratory. The immunohistochemistry technique applied to paraffin-embedded tissue may be used when no frozen tissue is available. Material and Methods. The aim of this study is to evaluate the sensitivity and specificity of immunohistochemistry compared with immunofluorescence. We describe the advantages and disadvantages of the immunohistochemistry vs. the immunofluorescence technique. For this purpose complement 4d staining was performed retrospectively by the two methods in indication biopsies (n=143) and graded using the Banff 07 classification. Results. There was total classification agreement between methods in 87.4% (125/143) of cases. However, immunohistochemistry staining caused more difficulties in interpretation, due to nonspecific staining in tubular cells and surrounding interstitium. All cases negative by immunofluorescence were also negative by immunohistochemistry. The biopsies were classified as positive in 44.7% (64/143) of cases performed by immunofluorescence vs. 36.4% (52/143) performed by immunohistochemistry. Fewer biopsies were classified as positive diffuse in the immunohistochemistry group(25.1% vs. 31.4%) and more as positive focal (13.2% vs. 11.1%). More cases were classified as negative by immunohistochemistry (63.6% vs. 55.2%). Study by ROC curve showed immunohistochemistry has a specificity of 100% and a sensitivity of 81.2% in relation to immunofluorescence (AUC: 0.906; 95% confidence interval: 0.846-0.949; p=0.0001). Conclusions. The immunohistochemistry method presents an excellent specificity but lower sensitivity to C4d detection in allograft dysfunction. The evaluation is more difficult, requiring a more experienced observer than the immunofluorescence method. Based on these results, we conclude that the immunohistochemistry technique can safely be used when immunofluorescence is not available.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of our study was to evaluate the accuracy of dynamic incremental bolus-enhanced conventional CT (DICT) with intravenous contrast administration, early phase, in the diagnosis of malignancy of focal liver lesions. A total of 122 lesions were selected in 74 patients considering the following criteria: lesion diameter 10 mm or more, number of lesions less than six per study, except in multiple angiomatosis and the existence of a valid criteria of definitive diagnosis. Lesions were categorized into seven levels of diagnostic confidence of malignancy compared with the definitive diagnosis for acquisition of a receiver-operator-characteristic (ROC) curve analysis and to determine the sensitivity and specificity of the technique. Forty-six and 70 lesions were correctly diagnosed as malignant and benign, respectively; there were 2 false-positive and 4 false-negative diagnoses of malignancy and the sensitivity and specificity obtained were 92 and 97%. The DICT early phase was confirmed as a highly accurate method in the characterization and diagnosis of malignancy of focal liver lesions, requiring an optimal technical performance and judicious analysis of existing semiological data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho realizado para a disciplina de Dissertação, Projeto ou Estágio do Instituto Superior Técnico de Engenharia do Porto, no ano letivo de 2014/2015, com a proposta de Dissertação no âmbito da transição das convencionais vias de ferrovia para as vias de levitação magnética, como parte dos requisitos à obtenção dos ECTS necessários à classificação final. Propõe-se nesta dissertação a aplicação de um sistema de levitação magnética que resulta da evolução dos sistemas existentes. A proposta exposta é uma melhoria que consiste numa possibilidade teórica de o trilho conseguir através do magnetismo, aplicar uma rotação ao veículo necessária em curva e ajustar essa rotação à velocidade a que se desloca. Para que este sistema funcione sugere-se a introdução de mais um campo magnético no trilho, que tem como função rodar o veículo em curva e substituir a sobrelevação ou escala do convencional trilho. Sugere-se que este sistema seja aplicado no território brasileiro em três fases distintas. Ligando numa primeira fase as três maiores cidades, seguido do litoral e por fim o interior do Brasil. A aplicação deste sistema no Brasil pode apresentar ser a solução ideal, em termos de velocidade e conforto, contudo é um sistema que necessita de estudos mais aprofundados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: C-reactive protein (CRP) and Bedside Index for Severity in Acute Pancreatitis (BISAP) have been used in early risk assessment of patients with AP. Objectives: We evaluated prognostic accuracy of CRP at 24 hours after hospital admission (CRP24) for in-hospital mortality (IM) in AP individually and with BISAP. Materials and Methods: This retrospective cohort study included 134 patients with AP from a Portuguese hospital in 2009---2010. Prognostic accuracy assessment used area under receiver---operating characteristic curve (AUC), continuous net reclassification improvement (NRI), and integrated discrimination improvement (IDI). Results: Thirteen percent of patients had severe AP, 26% developed pancreatic necrosis, and 7% died during index hospital stay. AUCs for CRP24 and BISAP individually were 0.80 (95% confidence interval (CI) 0.65---0.95) and 0.77 (95% CI 0.59---0.95), respectively. No patients with CRP24 <60 mg/l died (P = 0.027; negative predictive value 100% (95% CI 92.3---100%)). AUC for BISAP plus CRP24 was 0.81 (95% CI 0.65---0.97). Change in NRI nonevents (42.4%; 95% CI, 24.9---59.9%) resulted in positive overall NRI (31.3%; 95% CI, − 36.4% to 98.9%), but IDI nonevents was negligible (0.004; 95% CI, − 0.007 to 0.014). Conclusions: CRP24 revealed good prognostic accuracy for IM in AP; its main role may be the selection of lowest risk patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este relatório é elaborado no âmbito do estágio curricular no regime de parceria entre o Instituto Superior de Engenharia do Porto e o gabinete de projetos SE2P – Sociedade de Engenharia, Projetos e Planeamento, Lda. O tema do estágio é o estudo de colunas mistas aço-betão na vertente de projeto, mais concretamente através da criação dum processo de cálculo automático integrado com o modelo estrutural global. Aplicam-se os métodos de dimensionamento dos eurocódigos estruturais na avaliação da segurança dos estados limites. Avaliam-se as propriedades geométricas, determina-se a curva de interação, calcula-se a posição do eixo neutro donde se inferem os estados de tensão em flexão desviada ao nível da secção, necessários às verificações de segurança. O processo de cálculo tem por base uma folha de cálculo desenvolvida em Excel que, com ajuda do Visual Basic for Applications, comunica com o software de modelação e cálculo estrutural Autodesk Robot Professional Analisys. Cria-se fluxos de informação que possibilitam o cálculo iterativo de colunas mistas permitindo ajustar e por esta via otimizar as soluções de dimensionamento. A exportação de relatórios de cálculo detalhados para cada coluna constitui uma mais-valia para gabinetes de engenharia quando comparada com outras soluções de dimensionamento existentes no mercado. A aplicação do processo de cálculo desenvolvido a múltiplas combinações de soluções de colunas mistas permitiu analisar comparativamente os resultados obtidos e a criação de tabelas e ábacos que poderão ser úteis em cenários de pré-dimensionamento e de anteprojeto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Does carotid intima-media thickness (cIMT), a surrogate marker of cardiovascular events, have predictive incremental value over established risk factors for stable coronary artery disease (CAD)? Prospective study of 300 patients, with suspected stable CAD, admitted for an elective coronary angiography and carotid ultrasound. The CAD patients had a higher cIMT, which showed a modest predictive accuracy for CAD (area under the receiver-operating characteristic curve 0.638, 95% confidence interval 0.576-0.701, P < .001). The cIMT was an independent predictor of CAD, together with age, gender, and diabetes. C-statistic for CAD prediction by traditional risk factors was not significantly different from a model that included cIMT, carotid plaque presence, or both. However, in women, it was significantly increased by the addition of cIMT or carotid plaque presence. Although cIMT cannot be used as a sole indicator of CAD, it should be considered in the panel of investigations that is requested, particularly in women who are candidates for coronary angiography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine whether the slope of a maximal bronchial challenge test (in which FEV1 falls by over 50%) could be extrapolated from a standard bronchial challenge test (in which FEV1 falls up to 20%), 14 asthmatic children performed a single maximal bronchial challenge test with methacholin(dose range: 0.097–30.08 umol) by the dosimeter method. Maximal dose-response curves were included according to the following criteria: (1) at least one more dose beyond a FEV1 ù 20%; and (2) a MFEV1 ù 50%. PD20 FEV1 was calculated, and the slopes of the early part of the dose-response curve (standard dose-response slopes) and of the entire curve (maximal dose-response slopes) were calculated by two methods: the two-point slope (DRR) and the least squares method (LSS) in % FEV1 × umol−1. Maximal dose-response slopes were compared with the corresponding standard dose-response slopes by a paired Student’s t test after logarithmic transformation of the data; the goodness of fit of the LSS was also determined. Maximal dose-response slopes were significantly different (p < 0.0001) from those calculated on the early part of the curve: DRR20% (91.2 ± 2.7 FEV1% z umol−1)was 2.88 times higher than DRR50% (31.6 ± 3.4 DFEV1% z umol−1), and the LSS20% (89.1 ± 2.8% FEV1 z umol−1) was 3.10 times higher than LSS 50% (28.8 ± 1.5%FEV1 z umol−1). The goodness of fit of LSS 50% was significant in all cases, whereas LSS 20% failed to be significant in one. These results suggest that maximal dose-response slopes cannot be predicted from the data of standard bronchial challenge tests.