945 resultados para nerve conduction


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Standard needle electromyography (EMG) of 56 muscles and nerve conduction velocities (NCV) of the ulnar and common peroneal nerves were investigated in each of six cats affected with hypertrophic feline muscular dystrophy, 10 related heterozygote carriers and 10 normal cats. The EMG findings were considered normal in carrier and control cats, and consisted of 33% normal readings, 22% myotonic discharges, 18% fibrillation potentials, 11% prolonged insertional potentials, 10% complex repetitive discharges and 6% positive sharp waves in affected cats. Muscles of the proximal limbs were most frequently affected. No differences in NCV were found between the three cat groups. It was concluded that dystrophin-deficient dystrophic cats have widespread and frequent EMG changes, predominantly myotonic discharges and fibrillation potentials, which are most pronounced in the proximal appendicular muscles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The lipid bilayer of the myelin membrane of the central nervous system (CNS) and the peripheral nervous system (PNS) contains the oligodendrocyte- and Schwann cell-specific glycosphingolipids galactocerebrosides (GalC) and GalC-derived sulfatides (sGalC). We have generated a UDP-galactose ceramide galactosyltransferase (CGT) null mutant mouse (cgt−/−) with CNS and PNS myelin completely depleted of GalC and derived sGalC. Oligodendrocytes and Schwann cells are unable to restore the structure and function of these galactosphingolipids to maintain the insulator function of the membrane bilayer. The velocity of nerve conduction of homozygous cgt−/− mice is reduced to that of unmyelinated axons. This indicates a severely altered ion permeability of the lipid bilayer. GalC and sGalC are essential for the unperturbed lipid bilayer of the myelin membrane of CNS and PNS. The severe dysmyelinosis leads to death of the cgt−/− mouse at the end of the myelination period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To determine whether the visuospatial n-back working memory task is a reliable and valid measure of cognitive processes believed to underlie intelligence, this study compared the reaction times and accuracy of perforniance of 70 participants, with performance on the Multidimensional Aptitude Battery (MAB). Testing was conducted over two sessions separated by 1 week. Participants completed the MAB during the second test session. Moderate testretest reliability for percentage accuracy scores was found across the four levels of the n-back task, whilst reaction times were highly reliable. Furthermore, participants' performance on the MAB was negatively correlated with accuracy of performance at the easier levels of the n-back task and positively correlated with accuracy of performance at the harder task levels. These findings confirm previous research examining the cognitive basis of intelligence, and suggest that intelligence is the product of faster speed of information processing, as well as superior working memory capacity. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

International audience

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cette étude vise à caractériser le «crampage», une entité relativement nouvelle dans l’industrie ovine au Québec. Les signes cliniques se manifestent au pas, par une hyperflexion (hanche, grasset, jarret), d’un ou des deux membres pelviens. Cinq agneaux naturellement affectés et cinq agneaux appariés cliniquement normaux ont été soumis à des examens physique, neurologique et orthopédique, à des techniques d’imagerie avancée (tomodensitométrie, résonance magnétique), à des tests électrodiagnostiques (électromyogramme, vitesses de conduction nerveuse motrice et sensitive) puis à une nécropsie. Des hématologies, biochimies ainsi que des analyses du liquide céphalorachidien ont également été réalisées. Les résultats ont été comparés entre les groupes (affectés/cliniquement normaux). Il a été constaté à la tomodensitométrie que la surface du canal vertébral mesurée au niveau de la deuxième vertèbre lombaire était inférieure dans le groupe des agneaux affectés (p=0.045). Aucune répercussion n’a été constatée sur le segment de moelle épinière correspondant. La racine S2, quant à elle, était plus grêle dans le groupe des agneaux affectés (p=0.01). À l’issue de cette étude, une cause orthopédique, musculaire ou neurologique consécutive à une lésion structurale de la moelle épinière a été écartée. Il pourrait s‘agir d’une atteinte sensitive de la racine S2 altérant la sensation dans le membre affecté, toutefois, une anomalie fonctionnelle cérébrale ou de la moelle épinière dans le renflement lombaire, est également à considérer. Sans anomalie musculaire, l’appellation «crampage» est inexacte. Nous proposons de la remplacer par des termes plus descriptifs comme «syndrome d’hyperflexion» ou «high stepping gait».

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cette étude vise à caractériser le «crampage», une entité relativement nouvelle dans l’industrie ovine au Québec. Les signes cliniques se manifestent au pas, par une hyperflexion (hanche, grasset, jarret), d’un ou des deux membres pelviens. Cinq agneaux naturellement affectés et cinq agneaux appariés cliniquement normaux ont été soumis à des examens physique, neurologique et orthopédique, à des techniques d’imagerie avancée (tomodensitométrie, résonance magnétique), à des tests électrodiagnostiques (électromyogramme, vitesses de conduction nerveuse motrice et sensitive) puis à une nécropsie. Des hématologies, biochimies ainsi que des analyses du liquide céphalorachidien ont également été réalisées. Les résultats ont été comparés entre les groupes (affectés/cliniquement normaux). Il a été constaté à la tomodensitométrie que la surface du canal vertébral mesurée au niveau de la deuxième vertèbre lombaire était inférieure dans le groupe des agneaux affectés (p=0.045). Aucune répercussion n’a été constatée sur le segment de moelle épinière correspondant. La racine S2, quant à elle, était plus grêle dans le groupe des agneaux affectés (p=0.01). À l’issue de cette étude, une cause orthopédique, musculaire ou neurologique consécutive à une lésion structurale de la moelle épinière a été écartée. Il pourrait s‘agir d’une atteinte sensitive de la racine S2 altérant la sensation dans le membre affecté, toutefois, une anomalie fonctionnelle cérébrale ou de la moelle épinière dans le renflement lombaire, est également à considérer. Sans anomalie musculaire, l’appellation «crampage» est inexacte. Nous proposons de la remplacer par des termes plus descriptifs comme «syndrome d’hyperflexion» ou «high stepping gait».

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diabetic neuropathy is associated with increased morbidity and mortality. To date, limited data in subjects with impaired glucose tolerance and diabetes demonstrate nerve fiber repair after intervention. This may reflect a lack of efficacy of the interventions but may also reflect difficulty of the tests currently deployed to adequately assess nerve fiber repair, particularly in short-term studies. Corneal confocal microscopy (CCM) represents a novel noninvasive means to quantify nerve fiber damage and repair. Fifteen type 1 diabetic patients undergoing simultaneous pancreas-kidney transplantation (SPK) underwent detailed assessment of neurologic deficits, quantitative sensory testing (QST), electrophysiology, skin biopsy, corneal sensitivity, and CCM at baseline and at 6 and 12 months after successful SPK. At baseline, diabetic patients had a significant neuropathy compared with control subjects. After successful SPK there was no significant change in neurologic impairment, neurophysiology, QST, corneal sensitivity, and intraepidermal nerve fiber density (IENFD). However, CCM demonstrated significant improvements in corneal nerve fiber density, branch density, and length at 12 months. Normalization of glycemia after SPK shows no significant improvement in neuropathy assessed by the neurologic deficits, QST, electrophysiology, and IENFD. However, CCM shows a significant improvement in nerve morphology, providing a novel noninvasive means to establish early nerve repair that is missed by currently advocated assessment techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Corneal confocal microscopy (CCM) is a rapid non-invasive ophthalmic technique, which has been shown to diagnose and stratify the severity of diabetic neuropathy. Current morphometric techniques assess individual static images of the subbasal nerve plexus; this work explores the potential for non-invasive assessment of the wide-field morphology and dynamic changes of this plexus in vivo. Methods In this pilot study, laser scanning CCM was used to acquire maps (using a dynamic fixation target and semi-automated tiling software) of the central corneal sub-basal nerve plexus in 4 diabetic patients with and 6 without neuropathy and in 2 control subjects. Nerve migration was measured in an additional 7 diabetic patients with neuropathy, 4 without neuropathy and in 2 control subjects by repeating a modified version of the mapping procedure within 2-8 weeks, thus facilitating re-identification of distinctive nerve landmarks in the 2 montages. The rate of nerve movement was determined from these data and normalised to a weekly rate (µm/week), using customised software. Results Wide-field corneal nerve fibre length correlated significantly with the Neuropathy Disability Score (r = -0.58, p < 0.05), vibration perception (r = -0.66, p < 0.05) and peroneal conduction velocity (r = 0.67, p < 0.05). Central corneal nerve fibre length did not correlate with any of these measures of neuropathy (p > 0.05 for all). The rate of corneal nerve migration was 14.3 ± 1.1 µm/week in diabetic patients with neuropathy, 19.7 ± 13.3µm/week in diabetic patients without neuropathy, and 24.4 ± 9.8µm/week in control subjects; however, these differences were not significantly different (p = 0.543). Conclusions Our data demonstrate that it is possible to capture wide-field images of the corneal nerve plexus, and to quantify the rate of corneal nerve migration by repeating this procedure over a number of weeks. Further studies on larger sample sizes are required to determine the utility of this approach for the diagnosis and monitoring of diabetic neuropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fond : Le substrat de fibrillation auriculaire (FA) vagale et celui secondaire à remodelage par tachycardie auriculaire (RTA) partagent beaucoup des caractéristiques : période réfractaire efficace (PRE) réduite, hétérogénéité accrue de PRE et quelques mécanismes moléculaires communs. Cette étude a comparé les 2 substrats à une abréviation comparable de PRE. Méthodes : Chez chacun de 6 chiens de groupe de stimulation vagal (SV), les paramètres de stimulation cervicale bilatérale de nerves vagaux ont été ajustés pour produire la même PRE moyenne (calculé à 8 sites des oreillettes gauche et droite) avec 6 chiens de groupe de RTA assorti à sexe et poids. Des paramètres électrophysiologiques, la durée moyenne de la fibrillation auriculaire (DAF) et les fréquences dominantes (FD) locales ont étés calculés. Résultats : En dépit des PREs assorties (SV: 80±12msec contre RTA: 79±12msec) la DAF était plus longue (*), l’hétérogénéité de conduction était plus élevée (*), la FD était plus rapide (*) et la variabilité de FD plus grande (*) chez les chiens SV. Les zones de maximum FD qui reflètent les zones d’origine de FA étaient à côté de ganglions autonomes chez les chiens SV. Conclusions : Pour un PRE atriale comparable, la FA secondaire à SV est plus rapide et plus persistante que la FA avec un substrat de RTA. Ces résultats sont consistants avec des modèles de travail suggérant que l'hyperpolarisation SV-induite contribue de façon important à la stabilisation et à l'accélération des rotors qui maintiennent la FA. La similitude de la distribution de FD du groupe vagal avec la distribution des lésions d’ablation après cartographie des électrogrammes atriales fragmentés suggère des nouvelles techniques d’ablation. La distribution des FD entre le SV et le RTA fournit de nouvelles idées au sujet de possible rémodelage neuroreceptorial et indique des différences importantes entre ces substrats de FA superficiellement semblables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of −58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s−1. The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel fibrous conduit consisting of well-aligned nanofibers with longitudinal nanogrooves on the fiber surface was prepared by electrospinning and was subjected to an in vivo nerve regeneration study on rats using a sciatic nerve injury model. For comparison, a fibrous conduit having a similar fiber alignment structure without surface groove and an autograft were also conducted in the same test. The electrophysiological, walking track, gastrocnemius muscle, triple-immunofluorescence, and immunohistological analyses indicated that grooved fibers effectively improved sciatic nerve regeneration. This is mainly attributed to the highly ordered secondary structure formed by surface grooves and an increase in the specific surface area. Fibrous conduits made of longitudinally aligned nanofibers with longitudinal nanogrooves on the fiber surface may offer a new nerve guidance conduit for peripheral nerve repair and regeneration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Leprosy neuropathy, despite being primarily demyelinating, frequently leads to axonal loss. Neurophysiological examination of the nerves during Type 1 (T1R) and Type 2 reactions (T2R) may give some insight into the pathophysiological mechanisms.Methods: Neurophysiological examinations were performed in 28 ulnar nerves during a clinical trial of steroid treatment effectiveness, 19 patients with T1R and nine with T2R. The nerves were monitored during a period of 6 months; there were eight assessments per nerve, for a total of 224 assessments. Nine neurophysiological parameters were assessed at three sites of the ulnar nerve. The compound motor action potential amplitudes elicited at wrist, elbow and above, as well as the conduction velocity and temporal dispersion across the elbow, were chosen to focus on the changes occurring in the parameters at the elbow tunnel.Results and Conclusion: Neurophysiological changes indicating axonal and demyelinating processes during both T1R and T2R were detected across the elbow. Changes in demyelination, i.e. a Conduction Block, as a primary event present during T2R, occurring as an acute phenomenon, were observed regularly; in T1R Temporal Dispersion, a subacute phenomenon, was seen. During treatment remyelination occurred after both types of reactions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Shoulder arthroscopic surgeries evolve with intense postoperative pain. Several analgesic techniques have been advocated. The aim of this study was to compare suprascapular and axillary nerve blocks in shoulder arthroscopy using the interscalene approach to brachial plexus blockade. According to the technique used, sixty-eight patients were allocated into two groups: interscalene group (IG, n=34) and selective group (SG, n=34), with neurostimulation approach used for both techniques. After appropriate motor response, IG received 30 mL of 0.33% levobupivacaine in 50% enantiomeric excess with adrenalin 1:200,000. After motor response of suprascapular and axillary nerves, SG received 15 mL of the same substance on each nerve. General anesthesia was then administered. Variables assessed were time to perform the blocks, analgesia, opioid consumption, motor block, cardiovascular stability, patient satisfaction and acceptability. Time for interscalene blockade was significantly shorter than for selective blockade. Analgesia was significantly higher in the immediate postoperative period in IG and in the late postoperative period in SG. Morphine consumption was significantly higher in the first hour in SG. Motor block was significantly lower in SG. There was no difference between groups regarding cardiocirculatory stability and patient satisfaction and acceptability. Failure occurred in IG (1) and SG (2). Both techniques are safe, effective, and with the same degree of satisfaction and acceptability. The selective blockade of both nerves showed satisfactory analgesia, with the advantage of providing motor block restricted to the shoulder.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The time to reach the maximum response of arterial pressure, heart rate and vascular resistance (hindquarter and mesenteric) was measured in conscious male spontaneously hypertensive (SHR) and normotensive control rats (NCR; Wistar; 18-22 weeks) subjected to electrical stimulation of the aortic depressor nerve (ADN) under thiopental anesthesia. The parameters of stimulation were 1 mA intensity and 2 ms pulse length applied for 5 s, using frequencies of 10, 30, and 90 Hz. The time to reach the hemodynamic responses at different frequencies of ADN stimulation was similar for SHR (N = 15) and NCR (N = 14); hypotension = NCR (4194 +/- 336 to 3695 +/- 463 ms) vs SHR ( 3475 +/- 354 to 4494 +/- 300 ms); bradycardia = NCR (1618 +/- 152 to 1358 +/- 185 ms) vs SHR (1911 +/- 323 to 1852 +/- 431 ms), and the fall in hindquarter vascular resistance = NCR (6054 +/- 486 to 6550 +/- 847 ms) vs SHR (4849 +/- 918 to 4926 +/- 646 ms); mesenteric = NCR (5574 +/- 790 to 5752 +/- 539 ms) vs SHR (5638 +/- 648 to 6777 +/- 624 ms). In addition, ADN stimulation produced baroreflex responses characterized by a faster cardiac effect followed by a vascular effect, which together contributed to the decrease in arterial pressure. Therefore, the results indicate that there is no alteration in the conduction of the electrical impulse after the site of baroreceptor mechanical transduction in the baroreflex pathway (central and/or efferent) in conscious SHR compared to NCR.