962 resultados para multi-anode transverse field gas ionization chamber


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper consists in the evaluation of the exposure rate to ionizing radiation to which professionals working in surgical procedures which require radiological examinations are subjected. Were initially performed real-time readings of exposure rate within four distinct operating rooms during the execution of four surgical procedures that made use of fluoroscopy equipment (including three orthopedic surgeries, one in the shoulder, one in the arm, another for deployment of metal pin in the leg region, and a fourth for vascular procedure); in these surgeries were used ionization chamber detector and an electrometer. In order to check the values achieved, was made a re-evaluation of the distribution of the rate of exposure to radiation, from the surgical procedures, now with thermoluminescent dosimeters (TLDs). For this, thirty TLDs were distributed in the operating rooms, arranged in points of interest as occupation by professionals. The TLDs were prepared for thirty consecutive days, after which they were removed and replaced with new dosimeters not exposed yet. The dosimeters were subjected to reading of the rate of exposure; this procedure was repeated for four months without interruption. The quantification of the results sought primarily to convert the rate of exposure for equivalent dose rate, both in measurements with ionization chamber as in measurements with TLDs, in order to highlight the presence of the biological effect of ionizing radiation for comparisons within scientific context. Then, the results were plotted to establish the relationship between the values of equivalent dose and the distance to the central axis of the x -ray source, confirming the inverse square law for distance. Finally, the values were associated with the maximum limit recommended by the legislation for occupationally exposed individuals. The methodology for the analysis and quantification of the data in this work aims at implementing a work plan that meets ...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate the effects of quenched disorder on first-order quantum phase transitions on the example of the N-color quantum Ashkin-Teller model. By means of a strong-disorder renormalization group, we demonstrate that quenched disorder rounds the first-order quantum phase transition to a continuous one for both weak and strong coupling between the colors. In the strong-coupling case, we find a distinct type of infinite-randomness critical point characterized by additional internal degrees of freedom. We investigate its critical properties in detail and find stronger thermodynamic singularities than in the random transverse field Ising chain. We also discuss the implications for higher spatial dimensions as well as unusual aspects of our renormalization-group scheme. DOI: 10.1103/PhysRevB.86.214204

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[ES] En este trabajo se han determinado los niveles de 222Rn en el agua subterránea en la zona noreste de Gran Canaria a partir de 28 muestras de pozos en bombeo. La concentración de actividad de radón en una muestra de agua se determina mediante un sistema en circuito cerrado que consta de un monitor AlphaGUARD que mide la concentración de radón en aire por medio de una cámara de ionización y un conjunto AquaKIT que se utiliza para transferir el radón disuelto en la muestra de agua al aire del circuito. Los valores de la concentración de radón en agua de las muestras estudiadas varían entre 0.9 y 76.9 Bq/L. Debido a la peligrosidad radiológica del radón, en España se ha establecido un límite de actividad de 100 Bq/L de 222Rn para las aguas de consumo humano. Los valores obtenidos para todas las muestras analizadas se encuentran por debajo de este límite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The conversion coefficients from air kerma to ICRU operational dose equivalent quantities for ENEA’s realization of the X-radiation qualities L10-L35 of the ISO “Low Air Kerma rate” series (L), N10-N40 of the ISO “Narrow spectrum” series (N) and H10-H60 of the ISO “High Air-kerma rate” (H) series and two beams at 5 kV and 7.5 kV were determined by utilising X-ray spectrum measurements. The pulse-height spectra were measured using a planar high-purity germanium spectrometer (HPGe) and unfolded to fluence spectra using a stripping procedure then validate with using Monte Carlo generated data of the spectrometer response. HPGe portable detector has a diameter of 8.5 mm and a thickness of 5 mm. The entrance window of the crystal is collimated by a 0.5 mm thick Aluminum ring to an open diameter of 6.5 mm. The crystal is mounted at a distance of 5 mm from the Berillium window (thickness 25.4 micron). The Monte Carlo method (MCNP-4C) was used to calculate the efficiency, escape and Compton curves of a planar high-purity germanium detector (HPGe) in the 5-60 keV energy. These curves were used for the determination of photon spectra produced by the X-ray machine SEIFERT ISOVOLT 160 kV in order to allow a precise characterization of photon beams in the low energy range, according to the ISO 4037. The detector was modelled with the MCNP computer code and validated with experimental data. To verify the measuring and the stripping procedure, the first and the second half-value layers and the air kerma rate were calculated from the counts spectra and compared with the values measured using an a free-air ionization chamber. For each radiation quality, the spectrum was characterized by the parameters given in ISO 4037-1. The conversion coefficients from the air kerma to the ICRU operational quantities Hp(10), Hp(0.07), H’(0.07) and H*(10) were calculated using monoenergetic conversion coefficients. The results are discussed with respect to ISO 4037-4, and compared with published results for low-energy X-ray spectra. The main motivation for this work was the lack of a treatment of the low photon energy region (from a few keV up to about 60 keV).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The proton-nucleus elastic scattering at intermediate energies is a well-established method for the investigation of the nuclear matter distribution in stable nuclei and was recently applied also for the investigation of radioactive nuclei using the method of inverse kinematics. In the current experiment, the differential cross sections for proton elastic scattering on the isotopes $^{7,9,10,11,12,14}$Be and $^8$B were measured. The experiment was performed using the fragment separator at GSI, Darmstadt to produce the radioactive beams. The main part of the experimental setup was the time projection ionization chamber IKAR which was simultaneously used as hydrogen target and a detector for the recoil protons. Auxiliary detectors for projectile tracking and isotope identification were also installed. As results from the experiment, the absolute differential cross sections d$sigma$/d$t$ as a function of the four momentum transfer $t$ were obtained. In this work the differential cross sections for elastic p-$^{12}$Be, p-$^{14}$Be and p-$^{8}$B scattering at low $t$ ($t leq$~0.05~(GeV/c)$^2$) are presented. The measured cross sections were analyzed within the Glauber multiple-scattering theory using different density parameterizations, and the nuclear matter density distributions and radii of the investigated isotopes were determined. The analysis of the differential cross section for the isotope $^{14}$Be shows that a good description of the experimental data is obtained when density distributions consisting of separate core and halo components are used. The determined {it rms} matter radius is $3.11 pm 0.04 pm 0.13$~fm. In the case of the $^{12}$Be nucleus the results showed an extended matter distribution as well. For this nucleus a matter radius of $2.82 pm 0.03 pm 0.12$~fm was determined. An interesting result is that the free $^{12}$Be nucleus behaves differently from the core of $^{14}$Be and is much more extended than it. The data were also compared with theoretical densities calculated within the FMD and the few-body models. In the case of $^{14}$Be, the calculated cross sections describe the experimental data well while, in the case of $^{12}$Be there are discrepancies in the region of high momentum transfer. Preliminary experimental results for the isotope $^8$B are also presented. An extended matter distribution was obtained (though much more compact as compared to the neutron halos). A proton halo structure was observed for the first time with the proton elastic scattering method. The deduced matter radius is $2.60pm 0.02pm 0.26$~fm. The data were compared with microscopic calculations in the frame of the FMD model and reasonable agreement was observed. The results obtained in the present analysis are in most cases consistent with the previous experimental studies of the same isotopes with different experimental methods (total interaction and reaction cross section measurements, momentum distribution measurements). For future investigation of the structure of exotic nuclei a universal detector system EXL is being developed. It will be installed at the NESR at the future FAIR facility where higher intensity beams of radioactive ions are expected. The usage of storage ring techniques provides high luminosity and low background experimental conditions. Results from the feasibility studies of the EXL detector setup, performed at the present ESR storage ring, are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the first part of the thesis, we propose an exactly-solvable one-dimensional model for fermions with long-range p-wave pairing decaying with distance as a power law. We studied the phase diagram by analyzing the critical lines, the decay of correlation functions and the scaling of the von Neumann entropy with the system size. We found two gapped regimes, where correlation functions decay (i) exponentially at short range and algebraically at long range, (ii) purely algebraically. In the latter the entanglement entropy is found to diverge logarithmically. Most interestingly, along the critical lines, long-range pairing breaks also the conformal symmetry. This can be detected via the dynamics of entanglement following a quench. In the second part of the thesis we studied the evolution in time of the entanglement entropy for the Ising model in a transverse field varying linearly in time with different velocities. We found different regimes: an adiabatic one (small velocities) when the system evolves according the instantaneous ground state; a sudden quench (large velocities) when the system is essentially frozen to its initial state; and an intermediate one, where the entropy starts growing linearly but then displays oscillations (also as a function of the velocity). Finally, we discussed the Kibble-Zurek mechanism for the transition between the paramagnetic and the ordered phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The verification possibilities of dynamically collimated treatment beams with a scanning liquid ionization chamber electronic portal image device (SLIC-EPID) are investigated. The ion concentration in the liquid of a SLIC-EPID and therefore the read-out signal is determined by two parameters of a differential equation describing the creation and recombination of the ions. Due to the form of this equation, the portal image detector describes a nonlinear dynamic system with memory. In this work, the parameters of the differential equation were experimentally determined for the particular chamber in use and for an incident open 6 MV photon beam. The mathematical description of the ion concentration was then used to predict portal images of intensity-modulated photon beams produced by a dynamic delivery technique, the sliding window approach. Due to the nature of the differential equation, a mathematical condition for 'reliable leaf motion verification' in the sliding window technique can be formulated. It is shown that the time constants for both formation and decay of the equilibrium concentration in the chamber is in the order of seconds. In order to guarantee reliable leaf motion verification, these time constants impose a constraint on the rapidity of the image-read out for a given maximum leaf speed. For a leaf speed of 2 cm s(-1), a minimum image acquisition frequency of about 2 Hz is required. Current SLIC-EPID systems are usually too slow since they need about a second to acquire a portal image. However, if the condition is fulfilled, the memory property of the system can be used to reconstruct the leaf motion. It is shown that a simple edge detecting algorithm can be employed to determine the leaf positions. The method is also very robust against image noise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evidence-based decisions on indicated prevention in early psychosis require large-scale studies on the pathways to care in high-risk subjects. EPOS (The European Prediction of Psychosis Study), a prospective multi-center, naturalistic field study in four European countries (Finland, Germany, The Netherlands and England), was designed to acquire accurate knowledge about pathways to care and delay in obtaining specialized high risk care. Our high risk sample (n=233) reported on average 2.9 help-seeking contacts, with an average delay between onset of relevant problems to initial help-seeking contact of 72.6 weeks, and between initial help-seeking contact and reaching specialized high risk care of 110.9 weeks. This resulted in a total estimated duration of an unrecognized risk for psychosis of 3 ½ years. Across EPOS EU regions, about 90% of care pathway contacts were within professional health care sectors. Between EPOS regions, differences in the pathways parameters including early detection and health-care systems were often very pronounced. High-risk participants who later made transition to a full psychotic disorder had significantly longer delays between initial help-seeking and receiving appropriate interventions. Our study underlines the need for regionally adapted implementation of early detection and intervention programs within respective mental health and health care networks, including enhancing public awareness of early psychosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advanced wheat lines carrying the Hessian fly resistance gene H27 were obtained by backcrossing the wheat/Aegilops ventricosa introgression line, H-93-33, to commercial wheat cultivars as recurrent parents. The Acph-N v 1 marker linked to the gene H27 on the 4Nv chromosome of this line was used for marker assisted selection. Advanced lines were evaluated for Hessian fly resistance in field and growth chamber tests, and for other agronomic traits during several crop seasons at different localities of Spain. The hessian fly resistance levels of lines carrying the 4Nv chromosome introgression (4D/4Nv substitution and recombination lines that previously were classified by in situ hybridisation) were high, but always lower than that of their Ae. ventricosa progenitor. Introgression lines had higher grain yields in infested field trials than those without the 4Nv chromosome and their susceptible parents, but lower grain yields under high yield potential conditions. The 4Nv introgression was also associated with later heading, and lower tiller and grain numbers/m2 . In addition, it was associated with longer and more lax spikes, and higher values of grain weight and grain protein content. However, the glutenin and gliadin expression, as well as the bread-making performance, were similar to those of their recurrent parents

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to its small size and the restrictions on source and listener positions, the design of sound reproduction systems for car cabins is particularly cumbersome. In the present project the measurement of the impulse response between a single loudspeaker and a listener position, with special emphasis on the directional characteristics, will be examined. The propagation paths inside a car are very short, meaning that it is very difficult for the existing commercial measurement systems to resolve the different reflections arriving to the listener. This paper propose a first approach of an algorithm based on time difference of arrival along a measurement technique aiming at finding the reflections and their direction of arrival to the listener. To this end a circular microphone array at a known position is employed, along with Maximum-Length Sequences (MLS) measurement technique. The results are processed so as to extract the directional properties, demonstrate the physical limitations that can influence or prevent this detection in practice. Measurements were carried out in a free-field environment (anechoic chamber) making use of different panels closer around the microphone array. RESUMEN. El diseño de sistemas de reproducción de audio para cabinas de coche es especialmente complicado debido al reducido tamaño del espacio y las restricciones de los altavoces y posiciones de escucha de los ocupantes. En el presente proyecto, se examinan mediciones de la respuesta al impulso entre un altavoz y una posición de escucha con especial énfasis en las características direccionales. Los caminos de propagación de las ondas sonoras dentro de un coche son muy cortos, lo que hace difícil para los instrumentos de medida existentes en el mercado determinar las direcciones de llegada de las diferentes reflexiones que llegan a una posición de escucha. Este trabajo propone una primera aproximación de un algoritmo, basado en las diferencias temporales de llegada de una onda a diferentes puntos de medida, y una particular técnica de medida de la respuesta al impulso para obtener las direcciones de llegada de reflexiones a una posición de escucha. Para ello, se emplea una matriz circular de micrófonos en una posición conocida junto con la técnica de medida MLS (Maximum Length Sequence). Los resultados obtenidos son procesados para extraer la dirección de llegada de las reflexiones acústicas y encontrar las limitaciones que influyan en la detección de dichas reflexiones. Las mediciones se llevan a cabo en un entorno de campo libre y utilizando diferentes superficies reflectantes alrededor de la matriz de micrófonos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La medición y testeo de células fotovoltaicas en el laboratorio o en la industria exige reproducir unas condiciones de iluminación semejantes a las reales. Por eso se utilizan sistemas de iluminación basados en lámparas flash de Xenon que reproducen las condiciones reales en cuanto a nivel de irradiancia y espectro de la luz incidente. El objetivo de este proyecto es realizar los circuitos electrónicos necesarios para el disparo de dichas lámparas. El circuito de alimentación y disparo de una lámpara flash consta de una fuente de alimentación variable, un circuito de disparo para la ionización del gas Xenon y la electrónica de control. Nuestro circuito de disparo pretende producir pulsos adecuados para los dispositivos fotovoltaicos tanto en irradiancia, espectro y en duración, de forma que con un solo disparo consigamos el tiempo, la irradiancia y el espectro suficiente para el testeo de la célula fotovoltaica. La mayoría de estos circuitos exceptuando los específicos que necesita la lámpara, serán diseñados, simulados, montados en PCB y comprobados posteriormente en el laboratorio. ABSTRACT. Measurement and testing of photovoltaic cells in the laboratory or in industry requires reproduce lighting conditions similar to the real ones. So are used based lighting systems xenon flash lamps that reproduce the actual conditions in the level of irradiance and spectrum of the incident light. The objective of this project is to make electronic circuits required for such lamps shot. The power supply circuit and flash lamp shot consists of a variable power supply, a trigger circuit for Xenon gas ionization and the control electronics. Our shot circuit aims to produce pulses suitable for photovoltaic devices both irradiance, spectrum and duration, so that with a single shot get the time, the irradiance and spectrum enough for testing the photovoltaic cell. Most of these circuits except lamp specific requirements will be designed, simulated, and PCB mounted subsequently tested in the laboratory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present MBIS (Multivariate Bayesian Image Segmentation tool), a clustering tool based on the mixture of multivariate normal distributions model. MBIS supports multi-channel bias field correction based on a B-spline model. A second methodological novelty is the inclusion of graph-cuts optimization for the stationary anisotropic hidden Markov random field model. Along with MBIS, we release an evaluation framework that contains three different experiments on multi-site data. We first validate the accuracy of segmentation and the estimated bias field for each channel. MBIS outperforms a widely used segmentation tool in a cross-comparison evaluation. The second experiment demonstrates the robustness of results on atlas-free segmentation of two image sets from scan-rescan protocols on 21 healthy subjects. Multivariate segmentation is more replicable than the monospectral counterpart on T1-weighted images. Finally, we provide a third experiment to illustrate how MBIS can be used in a large-scale study of tissue volume change with increasing age in 584 healthy subjects. This last result is meaningful as multivariate segmentation performs robustly without the need for prior knowledge.