961 resultados para axial rotation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The irregular vibronic structure in the S-1<--S-0 resonant two-photon ionization (R2PI) spectrum of supersonically cooled triptycene is a result of a classic Exe Jahn-Teller effect [A. Furlan et al., J. Chem. Phys. 96, 7306 (1992)]. This is well characterized and can be used as an effective probe of intramolecular perturbations. Here we examine the S-1<--S-0 R2PI spectrum of 9-hydroxytriptycene and the fluorescence from various excited state vibronic levels. In this system the pseudorotation of the Jahn-Teller vibration is strongly coupled to the torsional motion of the bridgehead hydroxy group. This torsional motion results in a tunneling splitting in both the ground and excited states. The population of the upper level in the ground electronic state results in additional vibronic transitions becoming symmetry allowed in the R2PI spectrum that are forbidden in the bare triptycene molecule. The assignment of the R2PI and fluorescence spectra allows the potential energy surfaces of these vibrational modes to be accurately quantified. The full C-3v vibronic point group must be used to interpret the spectra. The time scale of the internal rotation of the-OH group and the butterfly flapping of the Jahn-Teller pseudorotation are of similar magnitude. The tunneling between the nine minima on the three dimensional potential energy surface is such that the Jahn-Teller pseudorotation occurs in concert with the-OH internal rotation. The Berry phase that is acquired during this motion is discussed. The simple physical picture emerges of the angle between two of the three benzene moieties opening in three equivalent ways in the S-1 electronic state. This geometry follows the position of the hydroxy group, which preferentially orients itself to point between these two rings. (C) 1998 American Institute of Physics. [S0021-9606(98)02348-4].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abnormal lower-limb biomechanics-in particular, abnormal pronation of the subtalar joint with concomitant increased internal rotation of the tibia-is one of the major causes of overuse injuries of the lower limb. A randomized, controlled, within-subjects research design (N = 14) was used to investigate the effect of a temporary felt orthosis and an antipronation taping technique to control the transverse tibial rotation position immediately after application and after each of two 10-minute periods of exercise. The results showed that the taping technique was superior to both the orthosis and no intervention in controlling tibial rotation position immediately after application and after 10 minutes of exercise. After 20 minutes of exercise, neither the tape nor the orthosis was significantly superior to the control; however, the trends suggested that some residual control was maintained. Future studies are needed to determine the amount of foot pronation control required to relieve symptoms in a symptomatic population in order to determine the clinical effectiveness of these treatment methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The functional brain organisation of mathematically gifted adolescents may be different from those of average mathematical ability. In this study we used fMRI to examine the neural circuitry that mediates the performance of mathematically gifted boys and average ability controls while engaged in mental rotation. Eight math gifted male adolescents and five average ability male adolescents were presented 18 control and 18 mental rotation trials in two separate blocks. Participants selected one of four test stimuli to match the target stimulus by pressing one of four fibreoptic buttons. The control task required a simple 'best match' for the target stimulus. EPI scans were acquired on a 3-T MR scanner and a fixed effects statistical analysis (SPM99) was used to identify areas of significant activation in the rotation tasks, for the two groups. The results indicate that during mental rotation both groups activate the parietal lobes bilaterally, though to different levels. Moreover, the math gifted are uniformly bilateral in their pattern of activation, and engage some anterior regions not found in those of average ability. These regions include bilateral prefrontal cortex and the right anterior cingulate, which may serve to heighten concentration, and to optimise the pre-planning of purposeful actions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on a self-similar array model, we systematically investigated the axial Young's modulus (Y-axis) of single-walled carbon nanotube (SWNT) arrays with diameters from nanometer to meter scales by an analytical approach. The results show that the Y-axis of SWNT arrays decreases dramatically with the increases of their hierarchy number (s) and is not sensitive to the specific size and constitution when s is the same, and the specific Young's modulus Y-axis(s) is independent of the packing configuration of SWNTs. Our calculations also show that the Y-axis of SWNT arrays with diameters of several micrometers is close to that of commercial high performance carbon fibers (CFs), but the Y-axis(s) of SWNT arrays is much better than that of high performance CFs. (C) 2005 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mental rotation involves the creation and manipulation of internal images, with the later being particularly useful cognitive capacities when applied to high-level mathematical thinking and reasoning. Many neuroimaging studies have demonstrated mental rotation to be mediated primarily by the parietal lobes, particularly on the right side. Here, we use fMRI to show for the first time that when performing 3-dimensional mental rotations, mathematically gifted male adolescents engage a qualitatively different brain network than those of average math ability, one that involves bilateral activation of the parietal lobes and frontal cortex, along with heightened activation of the anterior cingulate. Reliance on the processing characteristics of this uniquely bilateral system and the interplay of these anterior/posterior regions may be contributors to their mathematical precocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design: Fine-wire EMG rotator cuff onset time analysis in 2 matched groups of throwers with and without pain. Objective: To identify if there is a difference in the activation patterns of the rotator cuff muscles during a rapid shoulder external rotation task between throwers with and without pain. Background: The coordinated action of the rotator cuff is recognized as essential for glenohumeral joint control in the throwing athlete. Identification of abnormalities occurring in muscle activation patterns for injured athletes is relevant when prescribing rehabilitative exercises. Methods and Measures: Twelve throwers with shoulder pain were compared to a matched group of 11 asymptomatic throwers. Participants were matched for age, height, body mass, and habitual activity. Fine-wire EMG electrodes were inserted into the subscapularis, supraspinatus, and infraspinatus. EMG activity was measured during a reaction time task of rapid shoulder external rotation in a seated position. The timing of onset of EMG activity was analyzed in relation to visualization of a light (reaction time) and to the onset of infraspinatus activity (relative latency). Results: In the group with shoulder pain, the onset of subscapularis activity was found to be significantly delayed (reaction time, P = .0018; relative latency, P = .0005) from the onset of infraspinatus activity when compared to the control group. Conclusions: The presence of shoulder pain in these athletes was associated with a difference in the onset of subscapularis EMG activity during a rapid shoulder external rotation movement. This was an initial step in the understanding of the joint protection mechanisms of the glenohumeral joint and the problems that occur in throwers. This information may assist in providing future guidelines for more effective rehabilitation and prevention strategies for this condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aldehyde dehydrogenases (ALDHs) catabolize toxic aldehydes and process the vitamin A-derived retinaldehyde into retinoic acid (RA), a small diffusible molecule and a pivotal chordate morphogen. In this study, we combine phylogenetic, structural, genomic, and developmental gene expression analyses to examine the evolutionary origins of ALDH substrate preference. Structural modeling reveals that processing of small aldehydes, such as acetaldehyde, by ALDH2, versus large aldehydes, including retinaldehyde, by ALDH1A is associated with small versus large substrate entry channels (SECs), respectively. Moreover, we show that metazoan ALDH1s and ALDH2s are members of a single ALDH1/2 clade and that during evolution, eukaryote ALDH1/2s often switched between large and small SECs after gene duplication, transforming constricted channels into wide opened ones and vice versa. Ancestral sequence reconstructions suggest that during the evolutionary emergence of RA signaling, the ancestral, narrow-channeled metazoan ALDH1/2 gave rise to large ALDH1 channels capable of accommodating bulky aldehydes, such as retinaldehyde, supporting the view that retinoid-dependent signaling arose from ancestral cellular detoxification mechanisms. Our analyses also indicate that, on a more restricted evolutionary scale, ALDH1 duplicates from invertebrate chordates (amphioxus and ascidian tunicates) underwent switches to smaller and narrower SECs. When combined with alterations in gene expression, these switches led to neofunctionalization from ALDH1-like roles in embryonic patterning to systemic, ALDH2-like roles, suggesting functional shifts from signaling to detoxification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Our aim was to evaluate the challenges in obtaining a successful restoration of the rotation center as well as a good positioning of the acetabular component when using the minimally-invasive posterior approach for uncemented total hip replacement. Methods: In a comparative non-random prospective study, 64 adult patients underwent elective total hip arthroplasty using the minimally-invasive posterior approach performed by one single surgeon, All patients included in this study had a superior and lateral migration of the rotation center of the hip in comparison to the normal contralateral hip. Patients were excluded from the study if they presented the following: diagnosis of femoral neck fracture, displasic hip types 2, 3 and 4 (Crowe`s classification), osteoarthritis of the contralateral hip. Of the 64 patients in the study, 39 had a radiographic pre-op acetabular size planning equal or less than 50 mm and 25 patients had a radiographic pre-op acetabular size planning equal or more than 52 mm. We considered a good result the following goals: acetabular bend between 35 and 50 degrees, acetabular size according to the pre-op estimative with full contact in the three zones of DeLee-Charnley, a lower medial and vertical positioning of the rotation center in comparison with the pre-op values and a final limb discrepancy lower than 10 mm. Results: A better restoration of the rotation center, as well as, excellent acetabular positioning was found in patients with smaller acetabular size (equal or less than 50), p=0, 04. We must draw attention to two risks when using the minimally-invasive posterior approach: a vertical acetabular position and a lateral position of the acetabular component increasing the risk of a poor contact in the zone 1 due to an insufficient reaming of the medial acetabular host bone. Conclusion: We propose standard surgical approaches in patients with larger anatomical measurements (acetabular planning size more than 50).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3-hole 4.5 mm locking compression plate (LCP) or 3-hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws. Study Design Experimental. Sample Population Cadaveric adult equine forelimbs (*n=6 pairs). Methods For each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure. Results There were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points. Conclusion Biomechanically, fixation of the equine PIP joint with a 3-hole 4.5 mm LCP is equivalent to fixation with a 3-hole 4.5 mm narrow DCP under the test conditions used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we report our modelling evaluation on the effect of tracer density on axial dispersion in a batch oscillatory baffled column (OBC). Tracer solution of potassium nitrite, its specific density ranged from 1.0 to 1.5, was used in the study, and was injected to the vertical column from either the top or bottom. Local concentration profiles are measured using conductivity probes at two locations along the height of the column. Using the experimental measured concentration profiles together with both 'Tank-in-Series' and 'Plug Flow with Axial Dispersion' models, axial dispersion coefficients were determined and used to describe the effect of specific tracer density on mixing in the OBC. The results showed that the axial dispersion coefficients evaluated by the two models are very similar in both magnitudes and trends, and the range of variations in such coefficients is generally larger for the bottom injection than for the top one. Empirical correlations linking the mechanical energy for mixing, the specific density of tracer and axial dispersion coefficient were established. Using these correlations, we identified the enhancements of up to 269% on axial dispersion for various specific tracer densities. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) is an easily automated, reliable technique to investigate axial mixing within rotating drums. Moist bran can be clearly differentiated from dry bran using MRI allowing a non-segregating tracer for axial mixing. For a 20-cm diameter drum, the axial dispersion coefficient in the particle bed was 0.51 cm s(-2). Axial dispersion is scale-dependent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate split nitrogen (N) fertilization of maize applied in band at sowing and top dressing with and without crop rotation, under no-till. The experiment was conducted with six N rates at sowing (0, 20, 30, 40, 50 and 60 kg ha-1) combined with three rates in top dressing (40, 70, 100 kg ha-1) and two management systems: after five cropping sequences of maize and crop rotation (maize + soybean + oat + soybean + corn) in a randomized block design with four replications. The crop rotation system increased yield in approximately 7% in relation to the area without rotation. The split of nitrogen fertilization, in rates above 39 and 54 kg ha-1 at sowing and 70 and 40 kg ha-1 in top dressing, resulted in yield higher than that obtained with the application of 100 kg ha-1 in top dressing. Grain yield was higher with the rates 50 and 70 kg ha-1 of N compared with that obtained with 20 and 100 kg ha-1 at sowing and top dressing, respectively. The rate 70 kg ha-1 of N resulted in the highest yield at the lowest cost compared with the revenues and costs incurred with the rates 40 and 100 kg ha-1.