1000 resultados para Width


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Excitonic states in AlxGa1-xN/GaN quantum wells (QWs) are studied within the framework of effective-mass theory. Spontaneous and piezoelectric polarizations are included and their impact on the excitonic states and optical properties are studied. We witnessed a significant blue shift in transition energy when the barrier width decreases and we attributed this to the redistribution of the built-in electric field between well layers and barrier layers. For the exciton the binding energies, we found in narrow QWs that there exists a critical value for barrier width, which demarcates the borderline for quantum confinement effect and the quantum confined Stark effect. Exciton and free carrier radiative lifetimes are estimated by simple argumentation. The calculated results suggest that there are efficient non-radiative mechanisms in narrow barrier QWs. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The energy spectrum and the persistent currents are calculated for a finite-width mesoscopic annulus with radial potential barrier, threading a magnetic flux through the hole of the ring. Owing to the presence of tunneling barrier, the coupling effect leads to the splitting of each radial energy subband of individual concentrical rings into two one. Thus, total currents and currents carried by single high-lying eigenstate as a function of magnetic flux exhibit complicated patterns. However, periodicity and antisymmetry of current curves in the flux still preserve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 1.55 mu m InGaAsP-InP partly gain-coupled two-section DFB self-pulsation laser (SPL) with a varied ridge width has been fabricated. The laser produces self-pulsations with a frequency tuning range of more than 135 GHz. All-optical clock recovery from 40 Gb/s degraded data streams has been demonstrated. Successful lockings of the device at frequencies of 30 GHz, 40 GHz, 50 GHz, and 60 GHz to a 10 GHz sidemode injection are also conducted, which demonstrates the capability of the device for all-optical clock recovery at different frequencies. This flexibility of the device is highly desired for practical uses. Crown Copyright

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dependence of the excitonic lifetime on the well width has been studied in conventional GaAs/AlGaAs quantum wells. Two clearly different variations of the measured excitonic lifetime have been observed. For wide well widths, we find a nearly linear decrease of the lifetime with decreasing well width. However, when the well is further decreased, a saturation and even increase of the lifetime with decreasing well width are observed. The experimental data are compared with the theory of radiative excitonic recombination, and show that well width dependence of the measured photoluminescence lifetime can be attributed mainly to the change of the excitonic effective volume and the overlap integral as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A systematic investigation on the photoluminescence (PL) properties of InxGa1-xAs/AlyGa1-xAs (x = 0.15, y = 0, 0.33) strained quantum wells (SQWs) with well widths from 1.7 to 11.0 nm has been performed at 77 K under high pressure up to 40 kbar. The experimental results show that the pressure coefficients of the exciton peaks corresponding to transitions from the first conduction subband to the heavy-hole subband increase from 10.05 meV/kbar of 11.0 nm well to 10.62 meV/kbar of 1.8 nm well for In0.15Ga0.85As/GaAs SQWs. However, the corresponding pressure coefficients slightly decrease from 9.93 meV/kbar of 9.0 nm well to 9.73 meV/kbar of 1.7 nm well for In0.15Ga0.85As/Al0.33Ga0.67As SQWs. Calculations based on the Kronig-Penney model reveal that the increased or decreased barrier heights and the increased effective masses with pressure are the main reasons of the change in the pressure coefficients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the radiative excitonic lifetime as a function of the well width in GaAs/GaAlAs quantum wells. An increasing lifetime with decreasing well width has been observed in very narrow and high quality GaAs/GaAlAs quantum wells, and attributed to the reduced overlap of the electron and hole wave functions and the increase of the exciton effective volume. This is the first observation of its kind in the conventional GaAs/GaAlAs quantum wells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single longitudinal mode and narrow line width external cavity semiconductor laser is proposed. It is constructed with a semiconductor laser, collimator, a flame grating, and current and temperature control systems. The one facet of semiconductor laser is covered by high transmission film, and another is covered by high reflection film. The flame grating is used as light feedback element to select the mode of the semiconductor laser. The temperature of the constructed external cavity semiconductor laser is stabilized in order of 10(-3)degreesC by temperature control system. The experiments have been carried out and the results obtained-the spectral fine width of this laser is compressed to be less than 1.4MHz from its original line-width of more than 1200GHz and the output stability (including power and mode) is remarkably enhanced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports that the transmission of O6+ ions with energy of 150keV through capillaries in an uncoated Al2O3 membrane was measured, and agreements with previously reported results in general angular distribution of the transmitted ions and the transmission fractions as a function of the tilt angle well fitted to Gaussian-like functions were observed. Due to using an uncoated capillary membrane, our c is larger than that using a gold-coated one with a smaller value of E-p/q, which suggests a larger equilibrium charge Q(infinity) in our experiment. The observed special width variation with time and a larger width than that using a smaller E-p/q were qualitatively explained by using mean-field classical transport theory based on a classical-trajectory Monte Carlo simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Laminaria japonica Aresch breeding practice, two quantitative traits, frond length (FL) and frond width (FW), are the most important phenotypic selection index. In order to increase the breeding efficiency by integrating phenotypic selection and marker-assisted selection, the first set of QTL controlling the two traits were determined in F-2 family using amplified fragment length polymorphism (AFLP) and simple sequence repeat (SSR) markers. Two prominent L. japonicas inbred lines, one with "broad and thin blade" characteristics and another with "long and narrow blade" characteristics, were applied in the hybridization to yield the F-2 mapping population with 92 individuals. A total of 287 AFLP markers and 11 SSR markers were used to construct a L. japonica genetic map. The yielded map was consisted of 28 linkage groups (LG) named LG1 to LG28, spanning 1,811.1 cM with an average interval of 6.7 cM and covering the 82.8% of the estimated genome 2,186.7 cM. While three genome-wide significant QTL were detected on LG1 (two QTL) and LG4 for "FL," explaining in total 42.36% of the phenotypic variance, two QTL were identified on LG3 and LG5 for the trait "FW," accounting for the total of 36.39% of the phenotypic variance. The gene action of these QTL was additive and partially dominant. The yielded linkage map and the detected QTL can provide a tool for further genetic analysis of two traits and be potential for maker-assisted selection in L. japonica breeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a reflector insert, the original HM-3 lithotripter field at 20 kV was altered significantly with the peak positive pressure (p(+)) in the focal plane increased from 49 to 87 MPa while the -6 dB focal width decreased concomitantly from 11 to 4 mm. Using the original reflector, p(+) of 33 MPa with a -6 dB focal width of 18 mm were measured in a pre-focal plane 15-mm proximal to the lithotripter focus. However, the acoustic pulse energy delivered to a 28-mm diameter area around the lithotripter axis was comparable ( approximately 120 mJ). For all three exposure conditions, similar stone comminution ( approximately 70%) was produced in a mesh holder of 15 mm after 250 shocks. In contrast, stone comminution produced by the modified reflector either in a 15-mm finger cot (45%) or in a 30-mm membrane holder (14%) was significantly reduced from the corresponding values (56% and 26%) produced by the original reflector (no statistically significant differences were observed between the focal and pre-focal planes). These observations suggest that a low-pressure/broad focal width lithotripter field will produce better stone comminution than its counterpart with high-pressure/narrow focal width under clinically relevant in vitro comminution conditions.