969 resultados para Monitorização fetal
Effect of Sodium Cyclamate on the Rat Fetal Exocrine Pancreas: a Karyometric and Stereological Study
Resumo:
The cyclamate, a sweetner substance derived from N-cyclo-hexyl-sulfamic acid, is largely utilized as a non-caloric artificial edulcorant in foods and beverages as well as in the pharmaceutical industry. The objective of this study was to evaluate karyometric and stereological alterations in the rat fetal pancreas resulting from the intraperitoneal administration of sodium cyclamate. The exocrine pancreas of ten fetuses of rats were evaluated, five treated and five controls chosen at random, in which five rats that received from the 10th to 14th days of pregnancy an intraperitoneal daily injection of sodium cyclamate at 60 mg/Kg of body weight during 5 days. At the 20th day of gestation, the animals were removed and weighed, as were their placentas; the length of the umbilical cords also were measured. After the laboratory processing, semi-seriated 6mm cuts stained with haematoxyline and cosine were performed. In seven karyometric parameters (major, minor, and medium diameters, volume, area, perimeter, and volume-area ratio), the increase was statistically significant in the treated group when compared with control group. Stereological parameters showed in the treated group a significant increase in the cellular volume and a significant reduction in the numerical cellular density. These results showed that the sodium cyclamate in pregnant rats led to retardation of fetal development and hypertrophy in the exocrine pancreas of the rat fetuses.
Resumo:
The objective of this study is to compare the accuracy of sonographic estimation of fetal weight of macrosomic babies in diabetic vs non-diabetic pregnancies. Ali babies weighing 4000 g or more at birth, and who had ultrasound scans performed within one week of delivery were included in this retrospective study. Pregnancies with diabetes mellitus were compared to those without diabetes mellitus. The mean simple error (actual birthweight - estimated fetal weight); mean standardised absolute error (absolute value of simple error (g)/actual birthweight (kg)); and the percentage of estimated birthweight falling within 15% of the actual birthweight between the two groups were compared. There were 9516 deliveries during the study period. Of this total 1211 (12.7 %) babies weighed 4000 g or more. A total of 56 non-diabetic pregnancies and 19 diabetic pregnancies were compared. The average sonographic estimation of fetal weight in diabetic pregnancies was 8 % less than the actual birthweight, compared to 0.2 % in the non-diabetic group (p < 0.01). The estimated fetal weight was within 15% of the birthweight in 74 % of the diabetic pregnancies, compared to 93 % of the non-diabetic pregnancies (p < 0.05). In the diabetic group, 26.3 % of the birthweights were underestimated by more than 15 %, compared to 5.4 % in the non-diabetic group (p < 0.05). In conclusion, the prediction accuracy of fetal weight estimation using standard formulae in macrosomic fetuses is significantly worse in diabetic pregnancies compared to non-diabetic pregnancies. When sonographic fetal weight estimation is used to influence the mode of delivery for diabetic women, a more conservative cut-off needs to be considered.
Resumo:
If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.
Resumo:
We have established a realtime fetal tele-ultrasound consultation service in Queensland, which has been integrated into our routine clinical practice, The service, which uses ISDN transmission at 384 kbit/s, allows patients in Townsville to be examined by subspecialists in Brisbane, 1500 km away. For the 90 tele-ultrasound consultations performed for the first 71 patients, 90% of the babies have been delivered, and outcome data have been received on all the pregnancies. All significant anomalies and diagnoses have been confirmed. The referring clinicians would have physically referred 24 of the 71 patients to Brisbane in the absence of telemedicine. A crude cost-benefit calculation suggests that the tele-ultrasound service resulted in a net saving of A$6340, and at the same time enabled almost four times the number of consultations to be carried out.
Resumo:
This article examines the current status of fetal pulse oximetry (FPO) as a means of intrapartum assessment of fetal wellbeing. FPO has been developed to a stage where it is a safe and accurate indicator of intrapartum fetal oxygenation. In general, sliding the FPO sensor along the examiner's fingers and through the cervix, to lie alongside the fetal cheek or temple is easy The recent publication of a randomised controlled trial (RCT) of FPO versus conventional intrapartum monitoring has validated its use to reduce caesarean section rates for nonreassuring fetal status. An Australian multicentre RCT is currently underway. Maternal satisfaction rates with FPO are high. FPO may be used during labour when the electronic fetal heart rate trace is nonreassuring or when conventional monitoring is unreliable, such as with fetal arrhythmias. If the fetal oxygen saturation (FSpO(2)) values are < 30%, prompt obstetric intervention is indicated, such as fetal scalp blood sampling or delivery FSpO(2) monitoring should not form the sole basis of intrapartum fetal welfare assessment. Rather, the whole clinical picture should be considered.
Resumo:
The use of maternal epidural analgesia in labor may be associated with nonreassuring fetal heart rate (FHR) patterns. Fetal oxygen saturation (FSpO(2)) monitoring may improve assessment of fetal well-being during this time. Mean FSpO(2) values were compared over seven 5-minute epochs: 5 minutes prior to an epidural event (combined insertion of epidural/top-up epidural analgesia and infusion pump bolus), to 30 minutes following the event, including possible effects of maternal position and FHR pattern on FSpO(2) values. Mean FSpO(2) values were significantly different between the 5 minutes prior (49.5%) versus 16-20 minutes (44.3%, p
Resumo:
OBJECTIVE - To assess the timing of fetal growth spurt among pre-existing diabetic pregnancies (types 1 and 2) and its relationship with diabetic control. To correlate fetal growth acceleration with factors that might influence fetal growth. RESEARCH DESIGN AND METHODS - This retrospective study involved all pregestational diabetic pregnancies delivered at a tertiary obstetric hospital in Australia between 1 January 1994 and 31 December 1999. Pregnancies with major congenital fetal anomalies, multiple pregnancies, small-for-gestational-age pregnancies (90th centile for gestation) were compared with babies with normal birth weights. RESULTS- A total of 101 diabetic pregnancies were included. Diabetic mothers, who had LGA babies, had significantly higher prepregnancy body weight and BMI (P < 0.05). There were no differences in maternal age or parity among the two groups. There were also no differences in the first-, second-, and third-trimester HbA(1c) levels between the two groups. The abdominal circumference z-scores were significantly higher for LGA babies from 18 weeks and thereafter. The differences increased progressively as the gestation advanced. Maximum difference was noted in the third trimester (30-38 weeks). CONCLUSIONS - Fetal growth acceleration in LGA fetuses of diabetic mothers starts in the second trimester, from as early as 18 weeks. In this study, glucose control did not appear to have a direct effect on the incidence of LGA babies, and such observation might result from the effects of other confounding factors.
Resumo:
Objective To determine whether one should aim for glycaemia that is statistically 'normal' or for levels of glycaemia low enough to prevent macrosomia (if such a threshold exists) when glucose intolerance is detected during pregnancy Design An audit of pregnancy outcomes in women with impaired glucose tolerance in pregnancy as compared to a local age-matched reference group with normal glucose tolerance. Results Our study suggests that for most patients, more intensive therapy would not have been justified. Maternal smoking appeared to convey some 'advantages' in terms of neonatal outcomes, with reduction in large-for-gestational-age (LGA) infants and jaundice in babies of impaired glucose tolerance (IGT) mothers. Conclusions These observations demonstrate the importance of considering risk factors other than GTT results in analysing pregnancy outcomes, while emphasising that 'normalisation' of fetal size should not be our only therapeutic endpoint. Our detailed outcome review allows us to reassure patients with GDM that with current treatment protocols, they should have every expectation of a positive pregnancy outcome.
Resumo:
We compared the quality of realtime fetal ultrasound images transmitted using ISDN and IP networks. Four experienced obstetric ultrasound specialists viewed standard recordings in a randomized trial and rated the appearance of 30 fetal anatomical landmarks, each on a seven-point scale. A total of 12 evaluations were performed for various combinations of bandwidths (128, 384 or 768 kbit/s) and networks (ISDN or IF). The intraobserver coefficient of variation was 2.9%, 5.0%, 12.7% and 14.7% for the four observers. The mean overall ratings by each of the four observers were 4.6, 4.8, 5.0 and 5.3, respectively (a rating of 4 indicated satisfactory visualization and 7 indicated as good as the original recording). Analysis of variance showed that there were no significant interobserver variations nor significant differences in the mean scores for the different types of videoconferencing machines used. The most significant variable affecting the mean score was the bandwidth used. For ISDN, the mean score was 3.7 at 128 kbit/s, which was significantly worse than the mean score of 4.9 at 384 kbit/s, which was in turn significantly worse than the mean score of 5.9 at 768 kbit/s. The mean score for transmission using IP was about 0.5 points lower than that using ISDN across all the different bandwidths, but the differences were not significant. It appears that IP transmission in a private (non-shared) network is an acceptable alternative to ISDN for fetal tele-ultrasound and one deserving further study.
Resumo:
Studies across several species, particularly the mouse, show that growth hormone (GH, somatotrophin) is an important determinant of litter size, and to a lesser extent, of birth length. GH acts at all stages of development, from ovulation through preimplantation development to the late fetus, with actions on both embryo/fetus and mother contributing to successful fetal development. The fact that these are not more obvious in vivo is likely a result of redundancy of cytokine hormone action, particularly in relation to prolactin, which shares common actions and receptor locations with GH. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Objetivo: investigar a influência de duas sessões únicas de exercício resistido (circuito com pesos) e aeróbio sobre as alterações pressóricas, em indivíduos sedentários e normotensos. Métodos: foram avaliados pela monitorização numa situação controle, sem realização de exercícios (MAPA 1) 25 indivíduos, após exercício resistido (MAPA 2) e após exercício aeróbio (MAPA 3). Os exercícios resistidos foram realizados sob forma de circuito com pesos, com intensidade de 40% da força máxima individual e os exercícios aeróbicos em cicloergômetro, com intensidade entre 60% e 70% da freqüência cardíaca (FC) máxima alcançada no teste ergométrico. Resultados: a pressão arterial sistólica (PAS) de 24h e sub-períodos vigília e sono não apresentaram variações estatisticamente significantes quando comparada à MAPA2 e MAPA3 e MAPA2 e MAPA3 entre si. A pressão arterial diastólica (PAD) de 24h e diurna apresentaram reduções significantes (P<0,05). A média da freqüência cardíaca de 24h e no período vigília apresentou aumentos significativos (P<0,05) quando comparada a MAPA2 à MAPA3. Conclusão: uma sessão única de exercício resistido em indivíduos normotensos foi suficiente para promover reduções significativas dos níveis tensionais, no período de sono após o exercício, e a de exercício aeróbio nesses mesmos indivíduos, foi mais eficaz em promover reduções significativas dos níveis pressóricos.
Resumo:
The ability to monitor fetal heart rate is vital during late pregnancy and labor in order to evaluate fetal well-being. Current monitoring practice is essentially based on external cardiotocography and, less frequently, during labor, invasive fetal scalp electrocardiography. Many current and envisaged applications could benefi t from simpler devices using a 3-lead ECG confi guration. We are designing a maternity support belt with an embedded wireless 3-lead ECG sensor, and have investigated the infl uence of the ground electrode position on signal quality. Data from over 100 pregnant women was collected with the ground electrode placed in 3 locations in order to determine optimum electrode placement and belt form factor.
Resumo:
Recently, regulating mechanisms of branching morphogenesis of fetal lung rat explants have been an essential tool for molecular research. The development of accurate and reliable segmentation techniques may be essential to improve research outcomes. This work presents an image processing method to measure the perimeter and area of lung branches on fetal rat explants. The algorithm starts by reducing the noise corrupting the image with a pre-processing stage. The outcome is input to a watershed operation that automatically segments the image into primitive regions. Then, an image pixel is selected within the lung explant epithelial, allowing a region growing between neighbouring watershed regions. This growing process is controlled by a statistical distribution of each region. When compared with manual segmentation, the results show the same tendency for lung development. High similarities were harder to obtain in the last two days of culture, due to the increased number of peripheral airway buds and complexity of lung architecture. However, using semiautomatic measurements, the standard deviation was lower and the results between independent researchers were more coherent