989 resultados para Magnetic induction.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a factor referred to as k(f) for linear induction motor end effect analysis is presented. The mathematical model takes into account the longitudinal entry end effect. The entry end effect produces considerable distortion in magnetic field distribution. It is shown how this influence is derived from the machine-developed force that is calculated through the application of the I-D theory. The k(f) factor establishes the relationship between the longitudinal end effect and machine parameters, mainly the number of magnetic poles, secondary resistivity, and frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nanotherapy applied to cancer treatment is constantly evolving, and new approaches to current techniques, such as magnetohyperthermia, are being implemented to solve and minimize the limitations of conventional therapeutic strategies. The purpose of this study was to investigate the action of polyphosphate-coated maghemite nanoparticles (MNPs) on oral squamous cell carcinoma. Human oral cancer cells (UM-SCC14A) were incubated with MNPs at various concentrations and subjected to cell proliferation tests (MTT), apoptosis assays and transmission electron image analysis. Viability and apoptotic events were time and dose dependent. These in vitro tests showed that at the intermediate concentration tested there is no significant toxicity, as confirmed by transmission electron microscopy. For this reason this MNPs concentration was chosen for the subsequent in vivo tests. Oral tumor induction was performed by applying the carcinogen DMBA to Syrian hamsters. Animals were then treated by magnetohyperthermia using MNPs. No signs of general clinical symptoms of toxicity or abnormal behavioral reactions were observed. However, animals treated with MNPs and exposed to the alternating magnetic field in the hyperthermia procedure exhibited a significant and time dependent cancer regression, as confirmed by histopathological analyses and immunohistochemistry. Actually, in quantitative terms of the magnetotherapy efficacy involving these polyphosphate-coated MNPs, 100% recovery (12/12) was observed in the oral cancer tumor bearing Syrian hamsters seven days after the treatment with the magnetohyperthermia procedure. Data supports the suggestion that the MNPs-mediated hyperthermia represents a promising strategy for the treatment of oral cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The analysis of the feasibility and economics of amorphous core power transformers for induction heating applications in the field 10-50 kHz is developped. The results obtained on a 25 kHz-150 kVA concentric winding trial unit are presented. © 1990.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context: The aberrant processing of salience is thought to be a fundamental factor underlying psychosis. Cannabis can induce acute psychotic symptoms, and its chronic use may increase the risk of schizophrenia. We investigated whether its psychotic effects are mediated through an influence on attentional salience processing. Objective: To examine the effects of Delta 9-tetrahydrocannabinol (Delta 9-THC) and cannabidiol (CBD) on regional brain function during salience processing. Design: Volunteers were studied using event-related functional magnetic resonance imaging on 3 occasions after administration of Delta 9-THC, CBD, or placebo while performing a visual oddball detection paradigm that involved allocation of attention to infrequent (oddball) stimuli within a string of frequent (standard) stimuli. Setting: University center. Participants: Fifteen healthy men with minimal previous cannabis use. Main Outcome Measures: Symptom ratings, task performance, and regional brain activation. Results: During the processing of oddball stimuli, relative to placebo, Delta 9-THC attenuated activation in the right caudate but augmented it in the right prefrontal cortex. Delta 9-Tetrahydrocannabinol also reduced the response latency to standard relative to oddball stimuli. The effect of Delta 9-THC in the right caudate was negatively correlated with the severity of the psychotic symptoms it induced and its effect on response latency. The effects of CBD on task-related activation were in the opposite direction of those of Delta 9-THC; relative to placebo, CBD augmented left caudate and hippocampal activation but attenuated right prefrontal activation. Conclusions: Delta 9-Tetrahydrocannabinol and CBD differentially modulate prefrontal, striatal, and hippocampal function during attentional salience processing. These effects may contribute to the effects of cannabis on psychotic symptoms and on the risk of psychotic disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Antitumor activities have been described in selol, a hydrophobic mixture of molecules containing selenium in their structure, and also in maghemite magnetic nanoparticles (MNPs). Both selol and MNPs were co-encapsulated within poly(lactic-co-glycolic acid) (PLGA) nanocapsules for therapeutic purposes. The PLGA-nanocapsules loaded with MNPs and selol were labeled MSE-NC and characterized by transmission and scanning electron microscopy, electrophoretic mobility, photon correlation spectroscopy, presenting a monodisperse profile, and positive charge. The antitumor effect of MSE-NC was evaluated using normal (MCF-10A) and neoplastic (4T1 and MCF-7) breast cell lines. Nanocapsules containing only MNPs or selol were used as control. MTT assay showed that the cytotoxicity induced by MSE-NC was dose and time dependent. Normal cells were less affected than tumor cells. Cell death occurred mainly by apoptosis. Further exposure of MSE-NC treated neoplastic breast cells to an alternating magnetic field increased the antitumor effect of MSE-NC. It was concluded that selol-loaded magnetic PLGA-nanocapsules (MSE-NC) represent an effective magnetic material platform to promote magnetohyperthermia and thus a potential system for antitumor therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Mossy fiber sprouting (MFS) is a frequent finding following status epilepticus (SE). The present study aimed to test the feasibility of using manganese-enhanced magnetic resonance imaging (MEMRI) to detect MFS in the chronic phase of the well-established pilocarpine (Pilo) rat model of temporal lobe epilepsy (TLE). Methods: To modulate MFS, cycloheximide (CHX), a protein synthesis inhibitor, was coadministered with Pilo in a subgroup of animals. In vivo MEMRI was performed 3 months after induction of SE and compared to the neo-Timm histologic labeling of zinc mossy fiber terminals in the dentate gyrus (DG). Key Findings: Chronically epileptic rats displaying MFS as detected by neo-Timm histology had a hyperintense MEMRI signal in the DG, whereas chronically epileptic animals that did not display MFS had minimal MEMRI signal enhancement compared to nonepileptic control animals. A strong correlation (r = 0.81, p < 0.001) was found between MEMRI signal enhancement and MFS. Significance: This study shows that MEMRI is an attractive noninvasive method for detection of mossy fiber sprouting in vivo and can be used as an evaluation tool in testing therapeutic approaches to manage chronic epilepsy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Iron-platinum nanoparticles embedded in a poly(methacrylic acid) (PMA) polymer shell and fluorescently labeled with the dye ATTO 590 (FePt-PMA-ATTO-2%) are investigated in terms of their intracellular localization in lung cells and potential to induce a proinflammatory response dependent on concentration and incubation time. A gold core coated with the same polymer shell (Au-PMA-ATTO-2%) is also included. Using laser scanning and electron microscopy techniques, it is shown that the FePt-PMA-ATTO-2% particles penetrate all three types of cell investigated but to a higher extent in macrophages and dendritic cells than epithelial cells. In both cell types of the defense system but not in epithelial cells, a particle-dose-dependent increase of the cytokine tumor necrosis factor alpha (TNFalpha) is found. By comparing the different nanoparticles and the mere polymer shell, it is shown that the cores combined with the shells are responsible for the induction of proinflammatory effects and not the shells alone. It is concluded that the uptake behavior and the proinflammatory response upon particle exposure are dependent on the time, cell type, and cell culture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aseptic pachymeningitis is a rare and serious complication of rheumatoid arthritis (RA). Herein, we describe a patient with rheumatoid factor-positive and anti-cyclic citrullinated peptide-positive RA who experienced a focal seizure, with aphasia and convulsions of the right side of the body. The findings of magnetic resonance imaging and histologic analysis led to a diagnosis of rheumatoid pachymeningitis. Because the patient had a large number of CD20-expressing B lymphocytes, therapy with rituximab was started and has resulted in complete and sustained remission of both the pachymeningitis and the RA for >2 years. Despite a decrease in immunoglobulins, the patient has remained free of infections, which illustrates the favorable outcome that can result from therapeutic B cell depletion in this potentially lethal manifestation of RA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mechanism of contrast enhancement of tumors using magnetic resonance imaging was investigated in MCF7 human breast cancer implanted in nude mice. Dynamic contrast-enhanced images recorded at high spatial resolution were analyzed by an image analysis method based on a physiological model, which included the blood circulation, the tumor, the remaining tissues, and clearance via the kidneys. This analysis enabled us to map in rapidly enhancing regions within the tumor, the capillary permeability factor (capillary permeability times surface area per voxel volume) and the fraction of leakage space. Correlation of these maps with T2-weighted spin echo images, with histopathology, and with immunohistochemical staining of endothelial cells demonstrated the presence of dense permeable microcapillaries in the tumor periphery and in intratumoral regions that surrounded necrotic loci. The high leakage from the intratumoral permeable capillaries indicated an induction of a specific angiogenic process associated with stress conditions that cause necrosis. This induction was augmented in tumors responding to tamoxifen treatment. Determination of the distribution and extent of this stress-induced angiogenic activity by contrast-enhanced MRI might be of diagnostic and of prognostic value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Epidermal Langerhans cells (LC) are associated anatomically with epidermal nerves, and a product of these nerves, calcitonin gene-related peptide (CGRP), inhibits the antigen-presenting capacity of LC and macrophages. As the CGRP receptor appears to be coupled to Gs alpha protein, which in turn activates adenylate cyclase, the ability of CGRP to induce cAMP in LC was examined and correlated with functional effects. LC were isolated from murine epidermal cells using antibodies on magnetic microspheres. Exposure to CGRP induced a significant increase in cAMP content, which could be inhibited by coculture with a truncated form of CGRP [CGRP-(8-37)] that is a specific competitive inhibitor of CGRP. Substance P and calcitonin failed to induce cAMP in LC. Although culture in CGRP reduced the ability of murine epidermal cells enriched for LC content to present pigeon cytochrome c to a responsive clone or to present antigen for elicitation of delayed-type hypersensitivity in immune mice, culture in forskolin had little or no effect on antigen presentation despite increased cAMP content of LC as much or more than that induced by CGRP. The effect of CGRP on antigen presentation in these systems could be blocked with CGRP-(8-37). CGRP inhibited the induction of B7-2 by lipopolysaccharide on peritoneal macrophages and a LC line, whereas calcitonin did not. CGRP induces specific accumulation of cAMP in LC and inhibits LC antigen-presenting function by a receptor-mediated event. However, the induction of cAMP by itself does not account for inhibition of antigen presentation. Suppression of the expression of B7-2 may be one mechanism by which CGRP inhibits antigen presentation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the past decade, the numerical modeling of the magnetic field evolution in astrophysical scenarios has become an increasingly important field. In the crystallized crust of neutron stars the evolution of the magnetic field is governed by the Hall induction equation. In this equation the relative contribution of the two terms (Hall term and Ohmic dissipation) varies depending on the local conditions of temperature and magnetic field strength. This results in the transition from the purely parabolic character of the equations to the hyperbolic regime as the magnetic Reynolds number increases, which presents severe numerical problems. Up to now, most attempts to study this problem were based on spectral methods, but they failed in representing the transition to large magnetic Reynolds numbers. We present a new code based on upwind finite differences techniques that can handle situations with arbitrary low magnetic diffusivity and it is suitable for studying the formation of sharp current sheets during the evolution. The code is thoroughly tested in different limits and used to illustrate the evolution of the crustal magnetic field in a neutron star in some representative cases. Our code, coupled to cooling codes, can be used to perform long-term simulations of the magneto-thermal evolution of neutron stars.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During Ocean Drilling Program Leg 134 (Vanuatu), geological high sensitivity magnetic tools (GHMT) developed by CEA-LETI and TOTAL were used at two drill sites. GHMT combine two sensors, a proton magnetometer for total magnetic field measurements with an operational accuracy of 0.1 nanoteslas (nT), and a highly sensitive induction tool to measure the magnetic susceptibility with an operational accuracy of a few 10**-6 SI units. Hole 829A was drilled through an accretionary prism and the downhole measurements of susceptibility correlate well with other well-log physical properties. Sharp susceptibility contrasts between chalk and volcanic silt sediment provide complementary data that help define the lithostratigraphic units. At Hole 831B magnetic susceptibility and total field measurements were performed through a 700-m reef carbonate sequence of a guyot deposited on top of an andesitic volcano. The downhole magnetic susceptibility is very low and the amplitude of peak-to-peak anomalies is less than a few 10**-5 SI units. Based on the repeatability of the measurements, the accuracy of the magnetic logging measurements was demonstrated to be excellent. Total magnetic field data at Hole 831B reveal low magnetic anomalies of 0.5 to 5 nT and the measurement of a complete repeat section indicates an accuracy of 0.1 to 0.2 nT. Due to the inclination of the earth's magnetic field in this area (~-40°) and the very low magnetic susceptibility of the carbonate, the contribution of the induced magnetization to the total field measured in the hole is negligible. Unfortunately, because the core recovery was extremely poor (<5%) no detailed comparison between the core measurements and the downhole magnetic data could be made. Most samples have a diamagnetic susceptibility and very low intensity of remanent magnetization (< 10**-4 A/m), but a few samples have a stable remanent magnetization up to 0.005 A/m. These variations of the intensity of the remanent magnetization suggest a very heterogeneous distribution of the magnetization in the carbonate sequence that could explain the magnetic field anomalies measured in these weakly magnetized rocks.