573 resultados para MASK


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A phase-only encryption/decryption scheme with the readout based on the zeroth-order phase-contrast technique (ZOPCT), without the use of a phase-changing plate on the Fourier plane of an optical system based on the 4f optical correlator, is proposed. The encryption of a gray-level image is achieved by multiplying the phase distribution obtained directly from the gray-level image by a random phase distribution. The robustness of the encoding is assured by the nonlinearity intrinsic to the proposed phase-contrast method and the random phase distribution used in the encryption process. The experimental system has been implemented with liquid-crystal spatial modulators to generate phase-encrypted masks and a decrypting key. The advantage of this method is the easy scheme to recover the gray-level information from the decrypted phase-only mask applying the ZOPCT. An analysis of this decryption method was performed against brute force attacks. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3223629]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work studies the operation of source-follower buffers implemented with standard and graded-channel (GC) fully depleted (FD) SCI nMOSFETs at low temperatures. The analysis is performed by comparing the voltage gain of buffers implemented with GC and standard SOI nMOS transistors considering devices with the same mask channel length and same effective channel length. It is shown that the use of GC devices allows for achieving improved gain in all inversion levels in a wide range of temperatures. In addition, this improvement increases as temperature is reduced. It is shown that GC transistors can provide virtually constant gain, while for standard devices, the gain departs from the maximum value depending on the temperature and inversion level imposed by the bias current and input voltage. Two-dimensional numerical simulations were performed in order to study the reasons for the enhanced gain of GC MOSFETs at low temperatures. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work the performance of graded-channel (CC) SOI MOSFETs operating as source-follower buffers is presented. The experimental analysis is performed by comparing the gain and linearity of buffers implemented with CC and standard SOI MOS devices considering the same mask dimensions. It is shown that by using CC devices, buffer gain very close to the theoretical limit can be achieved, with improved linearity, while for standard devices the gain departs from the theoretical value depending on the inversion level imposed by the bias current and input voltage. Two-dimensional numerical simulations were performed in order to confirm some hypotheses proposed to explain the gain behavior observed in the experimental data. By using numerical simulations the channel length has been varied, showing that the gain of buffers implemented with CC devices remains close to the theoretical limit even when short-channel devices are adopted. It has also been shown that the length of a source-follower buffer using CC devices can be reduced by a factor of 5, in comparison with a standard Sol MOSFET, without gain loss or linearity degradation. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aqueous extract prepared from Schizolobium parahyba (Sp) leaves, a native plant from Atlantic Forest (Brazil), was tested to analyse its ability to inhibit some biological and enzymatic activities induced by Bothrops alternatus (BaltCV) and Bothrops moojeni (BmooCV) snake venoms. Sp inhibited 100% of lethality, blood incoagulability, haemorrhagic and indirect haemolytic activities at a 1:10 ratio (venom/extract, w/w), as well as coagulant activity at a 1:5 ratio (venom/extract, w/w) induced by both venoms. BaltCV fibrinogenolytic activity was also neutralized by Sp at a 1:10 ratio, resulting in total protection of fibrinogen B beta chain and partial protection of A alpha chain. Interaction tests have demonstrated that, at certain extract/proteins ratios, Sp precipitates proteins non-specifically suggesting the presence of tannins, which are very likely responsible for the excellent inhibiting effects of the analysed ophidian activities. Sp aqueous extract chromatography on Sephadex LH-20 was carried out aiming at the separation of these compounds that mask the obtained results. Thus, the fractionation of Sp resulted in three fractions: F1 (methanolic fraction); F2 (methanol:water fraction, 1:1 v/v); and F3 (aqueous fraction). These fractions were analysed for their ability to inhibit the BaltCV fibrinogenolytic activity. F1 inhibited 100% the venom fibrinogenolytic activity without presenting protein precipitation effect; F2 showed only partial inhibition of this venom activity. Finally, F3 did not inhibit fibrinogen proteolysis, but presented strong protein precipitating action. We conclude that Sp aqueous extract, together with tannins, also contains other compounds that can display specific inhibitory activity against snake venom toxins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is well established that insomniacs overestimate sleep-onset latency. Furthermore, there is evidence that brief arousals from sleep may occur more frequently in insomnia. This study examined the hypothesis that brief arousals from sleep influence the perception of sleep-onset latency. An average of four sleep onsets was obtained from each of 20 normal subjects on each of two nonconsecutive, counterbalanced, experimental nights. The experimental nights consisted of a control night (control condition) and a condition in which a moderate respiratory load was applied to increase the frequency of microarousals during sleep onset (mask condition). Subjective estimation of sleep-onset latency and indices of sleep quality were assessed by self-report inventory. Objective measures of sleep-onset latency and microarousals were assessed using polysomnography. Results showed that sleep-onset latency estimates were longer in the mask condition than in the control condition, an effect not reflected in objective sleep-stage scoring of sleep-onset latency. Furthermore, an increase in the frequency of brief arousals from sleep was detected in the mask condition, and this is a possible source for the sleep-onset latency increase perceived by the subjects. Findings are consistent with the concept of a physiological basis for sleep misperception in insomnia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents observations of summertime anti-winds monitored under ideal conditions in the Lake Tekapo hydro-catchment situated in the central Southern Alps, New Zealand. Onset and cessation of anti-winds was observed to coincide with the change in phase of the surface limbs of thermally generated valley and mountain winds under settled anti-cyclonic conditions. Anti-winds were best developed in the early morning before surface heating and associated convective mixing of the valley atmosphere began to mask the boundaries between the surface based limb of the mountain-valley wind and the corresponding anti-wind. By mid-day, the anti-valley wind exceeded the height of the surrounding ridgeline and became embedded in the topographically channeled gradient wind. Observations presented here have both theoretical and applied implications with regard to the development of thermally generated wind systems in deep alpine valleys, and their role in the dispersion of air pollution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC). DESIGN: Observational cohort study. METHODS: The study included 377 eyes of 221 patients with a median follow-up of 4.0 years. Images were obtained annually with the GDx VCC (Carl Zeiss Med, itec Inc, Dublin, California, USA), along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. Progression was determined by the Guided Progression Analysis software for SAP and by masked assessment of stereophotographs by expert graders. The typical scan score (TSS) was used to quantify the presence of ARPs on GDx VCC images. Random coefficients models were used to evaluate the relationship between ARP and RNFL thickness measurements over time. RESULTS: Thirty-eight eyes (10%) showed progression over time on visual fields, stereophotographs, or both. Changes in TSS scores from baseline were significantly associated with changes in RNFL thickness measurements in both progressing and nonprogressing eyes. Each I unit increase in TSS score was associated with a 0.19-mu m decrease in RNFL thickness measurement (P < .001) over time. CONCLUSIONS: ARPs had a significant effect on detection of progressive RNFL loss with the GDx VCC. Eyes with large amounts of atypical patterns, great fluctuations on these patterns over time, or both may show changes in measurements that can appear falsely as glaucomatous progression or can mask true changes in the RNFL. (Am J Ophthalmol 2009;148:155-163. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kishi D; Videira RLR Description of Nosocomial Infection Prevention Practices by Anesthesiologists in a University Hospital. Background and objectives: Anesthesiologists play an important role in the prevention of nosocomial infections. In anesthetic practice, physiologic barriers are routinely breached, allowing patient contamination with microorganisms and the consequent development of infection. The lack of adhesion to recommended practices can facilitate transmission of microorganisms. It is important to describe prophylactic practices of anesthesia-related nosocomial infections performed by anesthesiologists. Methods: Structured questionnaires were distributed to be answered voluntarily and anonymously by anesthesiologists. Results: Among 112 anesthesiologists, 75% answered the questionnaire. Surgical mask is used by 95.2% of anesthesiologists, 96.3% wear gloves frequently, 98.9% wear sterile gloves for neuraxial block, 91.3% use sterile technique for central venous puncture, 95.1% wash their hands between cases, 91.6% try to maintain the endotracheal tube sterile, 96.3% discard the prefilled propofol syringe at the end of each anesthesia, 30% clean the vials before using it in the neuraxial blocks, and 19.8% clean the vials before intravenous use. Conclusions: Respondents showed good adhesion to practices of nosocomial infection prophylaxis and to improve them educational multidisciplinary campaigns are necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To describe knowledge, practices, and associated factors of medical students to prevent transmission of tuberculosis (TB) in five medical schools. Methods. Cross-sectional survey of undergraduate medical students in preclinical and in early and late clinical years. Information was obtained on sociodemographic profile, previous lectures on TB, knowledge about TB transmission, exposure to patients with active pulmonary TB, and use of respiratory protective masks. Results. Among 1 094 respondents, 575 (52.6%) correctly answered that coughing, speaking, and sneezing can transmit TB. Early [adjusted odds ratio = 4.0 (3.0, 5.5)] and late [adjusted odds ratio = 4.2 (3.1, 5.8)] clinical years were associated with correct answers, but having had previous lectures on TB was not. Among those who had previous lectures on TB, the rate of correct answers increased from 42.1% to 61.6%. Among 332 medical students who reported exposure to TB patients, 194 (58.4%) had not used protective masks. More years of clinical experience was associated with the use of masks [adjusted odds ratio = 2.9 (1.4, 6.1)], while knowledge was inversely associated with the use of masks [adjusted odds ratio = 0.4 (0.2, 0.6)]. Conclusions. Many medical students are not aware of the main routes of TB infection, and lectures on TB are not sufficient to change knowledge and practices. Regardless of knowledge about TB transmission, students engage in risky behaviors: more than two-thirds do not use a protective mask when examining an active TB case. We suggest innovative, effective active learning experiences to change this scenario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This case report describes the nonsurgical, nonextraction therapy of a 16-year-old boy with a skeletal Class III malocclusion, a prognathic mandible, and a retrusive maxilla. He was initially classified as needing orthognathic surgery, but he and his parents wanted to avoid that. The Class III malocclusion was corrected with a rapid palatal expander and a maxillary protraction mask followed by nonextraction orthodontic treatment with fixed appliances, combined with short Class III and vertical elastics in the anterior area. The height of the maxillary alveolar process and the vertical face height were slightly increased with treatment. Class I molar and canine relationships were achieved, and the facial profile improved substantially. (Am J Orthod Dentofacial Orthop 2009; 136: 736-45)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concept of a basic (i.e., essential) medical emergency kit suitable for a general dental practitioner varies somewhat between different authorities. A practitioner's choice is also dependant on the proximity of medical aid and the nature of the dental practice. Over recent years the trend has been to restrict the items to a minimum, in the interest of both common sense and safety, for example, just oxygen, adrenaline 1:1000, an oral carbohydrate source, glyceryl trinitrate and aspirin as first options. Ancillary equipment should include an oxygen therapy facemask, a pocket mask and a set of oral (Guedel) airways. Two further medication options for consideration are an aerosol bronchodilator and, in certain circumstances, an injectable antihypoglycaemic agent. This paper provides a selective overview of the subject. An absolute necessity is for dentists to be competent in Basic Life Support skills, and to maintain a complete and current medical history for all patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A crescente complexidade dos sistemas electrónicos associada a um desenvolvimento nas tecnologias de encapsulamento levou à miniaturização dos circuitos integrados, provocando dificuldades e limitações no diagnóstico e detecção de falhas, diminuindo drasticamente a aplicabilidade dos equipamentos ICT. Como forma de lidar com este problema surgiu a infra-estrutura Boundary Scan descrita na norma IEEE1149.1 “Test Access Port and Boundary-Scan Architecture”, aprovada em 1990. Sendo esta solução tecnicamente viável e interessante economicamente para o diagnóstico de defeitos, efectua também outras aplicações. O SVF surgiu do desejo de incutir e fazer com que os fornecedores independentes incluíssem a norma IEEE 1149.1, é desenvolvido num formato ASCII, com o objectivo de enviar sinais, aguardar pela sua resposta, segundo a máscara de dados baseada na norma IEEE1149.1. Actualmente a incorporação do Boundary Scan nos circuitos integrados está em grande expansão e consequentemente usufrui de uma forte implementação no mercado. Neste contexto o objectivo da dissertação é o desenvolvimento de um controlador boundary scan que implemente uma interface com o PC e possibilite o controlo e monitorização da aplicação de teste ao PCB. A arquitectura do controlador desenvolvido contém um módulo de Memória de entrada, um Controlador TAP e uma Memória de saída. A implementação do controlador foi feita através da utilização de uma FPGA, é um dispositivo lógico reconfiguráveis constituído por blocos lógicos e por uma rede de interligações, ambos configuráveis, que permitem ao utilizador implementar as mais variadas funções digitais. A utilização de uma FPGA tem a vantagem de permitir a versatilidade do controlador, facilidade na alteração do seu código e possibilidade de inserir mais controladores dentro da FPGA. Foi desenvolvido o protocolo de comunicação e sincronização entre os vários módulos, permitindo o controlo e monitorização dos estímulos enviados e recebidos ao PCB, executados automaticamente através do software do Controlador TAP e de acordo com a norma IEEE 1149.1. A solução proposta foi validada por simulação utilizando o simulador da Xilinx. Foram analisados todos os sinais que constituem o controlador e verificado o correcto funcionamento de todos os seus módulos. Esta solução executa todas as sequências pretendidas e necessárias (envio de estímulos) à realização dos testes ao PCB. Recebe e armazena os dados obtidos, enviando-os posteriormente para a memória de saída. A execução do trabalho permitiu concluir que os projectos de componentes electrónicos tenderão a ser descritos num nível de abstracção mais elevado, recorrendo cada vez mais ao uso de linguagens de hardware, no qual o VHDL é uma excelente ferramenta de programação. O controlador desenvolvido será uma ferramenta bastante útil e versátil para o teste de PCBs e outras funcionalidades disponibilizadas pelas infra-estruturas BS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes an online mechanism that can evaluate the sensitivity of single event upsets (SEUs) of field programmable gate arrays (FPGAs). The online detection mechanism cyclically reads and compares the values form the external and internal configuration memories, taking into account the mask information. This remote detection method also signals any mismatch as a result of a SEU that affects both used and not-used FPGA parts, which maximizes the monitored area. By utilizing an external, Web-accessible controller that is connected to the test infrastructure, the possibility of running the same operation in a remote manner is enabled. Moreover, the need for a local memory to store the mask values is also eliminated.