915 resultados para Intra-observer errors


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate and compare the intraobserver and interobserver reliability and agreement for the biparietal diameter (BPD), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW) obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US). Methods Singleton pregnant women between 24 and 40 weeks were invited to participate in this study. They were examined using 2D-US in a blinded manner, twice by one observer, intercalated by a scan by a second observer, to determine BPD, AC and FL. In each of the three examinations, three 3D-US datasets (head, abdomen and thigh) were acquired for measurements of the same parameters. We determined EFW using Hadlock's formula. Systematic errors between 3D-US and 2D-US were examined using the paired t-test. Reliability and agreement were assessed by intraclass correlation coefficients (ICCs), limits of agreement (LoA), SD of differences and proportion of differences below arbitrary points. Results We evaluated 102 singleton pregnancies. No significant systematic error between 2D-US and 3D-US was observed. The ICC values were higher for 3D-US in both intra- and interobserver evaluations; however, only for FL was there no overlap in the 95% CI. The LoA values were wider for 2D-US, suggesting that random errors were smaller when using 3D-US. Additionally, we observed that the SD values determined from 3D-US differences were smaller than those obtained for 2D-US. Higher proportions of differences were below the arbitrarily defined cut-off points when using 3D-US. Conclusion 3D-US improved the reliability and agreement of fetal measurements and EFW compared with 2D-US.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to compare inter-observer agreement of Stratus™ OCT versus Spectralis™ OCT image grading in patients with neovascular age-related macular degeneration (AMD). Thirty eyes with neovascular AMD were examined with Stratus™ OCT and Spectralis™ OCT. Four different scan protocols were used for imaging. Three observers graded the images for the presence of various pathologies. Inter-observer agreement between OCT models was assessed by calculating intra-class correlation coefficients (ICC). In Stratus™ OCT highest interobserver agreement was found for subretinal fluid (ICC: 0.79), and in Spectralis™ OCT for intraretinal cysts (IRC) (ICC: 0.93). Spectralis™ OCT showed superior interobserver agreement for IRC and epiretinal membranes (ERM) (ICC(Stratus™): for IRC 0.61; for ERM 0.56; ICC(Spectralis™): for IRC 0.93; for ERM 0.84). Increased image resolution of Spectralis™ OCT did improve the inter-observer agreement for grading intraretinal cysts and epiretinal membranes but not for other retinal changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: This study is based on a comprehensive survey of the neuropsychological attention-deficit hyperactivity disorder (ADHD) literature and presents the first psychometric analyses of different parameters of intra-subject variability (ISV) in patients with ADHD compared to healthy controls, using the Continuous Performance Test, a Go-NoGo task, a Stop Signal Task, as well as N-back tasks. METHODS: Data of 57 patients with ADHD and 53 age- and gender-matched controls were available for statistical analysis. Different parameters were used to describe central tendency (arithmetic mean, median), dispersion (standard deviation, coefficient of variation, consecutive variance), and shape (skewness, excess) of reaction time distributions, as well as errors (commissions and omissions). RESULTS: Group comparisons revealed by far the strongest effect sizes for measures of dispersion, followed by measures of central tendency, and by commission errors. Statistical control of ISV reduced group differences in the other measures substantially. One (patients) or two (controls) principal components explained up to 67% of the inter-individual differences in intra-individual variability. CONCLUSIONS: Results suggest that, across a variety of neuropsychological tests, measures of ISV contribute best to group discrimination, with limited incremental validity of measures of central tendency and errors. Furthermore, increased ISV might be a unitary construct in ADHD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To study the inter-observer variation related to extraction of continuous and numerical rating scale data from trial reports for use in meta-analyses. DESIGN: Observer agreement study. DATA SOURCES: A random sample of 10 Cochrane reviews that presented a result as a standardised mean difference (SMD), the protocols for the reviews and the trial reports (n=45) were retrieved. DATA EXTRACTION: Five experienced methodologists and five PhD students independently extracted data from the trial reports for calculation of the first SMD result in each review. The observers did not have access to the reviews but to the protocols, where the relevant outcome was highlighted. The agreement was analysed at both trial and meta-analysis level, pairing the observers in all possible ways (45 pairs, yielding 2025 pairs of trials and 450 pairs of meta-analyses). Agreement was defined as SMDs that differed less than 0.1 in their point estimates or confidence intervals. RESULTS: The agreement was 53% at trial level and 31% at meta-analysis level. Including all pairs, the median disagreement was SMD=0.22 (interquartile range 0.07-0.61). The experts agreed somewhat more than the PhD students at trial level (61% v 46%), but not at meta-analysis level. Important reasons for disagreement were differences in selection of time points, scales, control groups, and type of calculations; whether to include a trial in the meta-analysis; and data extraction errors made by the observers. In 14 out of the 100 SMDs calculated at the meta-analysis level, individual observers reached different conclusions than the originally published review. CONCLUSIONS: Disagreements were common and often larger than the effect of commonly used treatments. Meta-analyses using SMDs are prone to observer variation and should be interpreted with caution. The reliability of meta-analyses might be improved by having more detailed review protocols, more than one observer, and statistical expertise.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The abstraction of data from medical records is a widespread practice in epidemiological research. However, studies using this means of data collection rarely report reliability. Within the Transition after Childhood Cancer Study (TaCC) which is based on a medical record abstraction, we conducted a second independent abstraction of data with the aim to assess a) intra-rater reliability of one rater at two time points; b) the possible learning effects between these two time points compared to a gold-standard; and c) inter-rater reliability. METHOD Within the TaCC study we conducted a systematic medical record abstraction in the 9 Swiss clinics with pediatric oncology wards. In a second phase we selected a subsample of medical records in 3 clinics to conduct a second independent abstraction. We then assessed intra-rater reliability at two time points, the learning effect over time (comparing each rater at two time-points with a gold-standard) and the inter-rater reliability of a selected number of variables. We calculated percentage agreement and Cohen's kappa. FINDINGS For the assessment of the intra-rater reliability we included 154 records (80 for rater 1; 74 for rater 2). For the inter-rater reliability we could include 70 records. Intra-rater reliability was substantial to excellent (Cohen's kappa 0-6-0.8) with an observed percentage agreement of 75%-95%. In all variables learning effects were observed. Inter-rater reliability was substantial to excellent (Cohen's kappa 0.70-0.83) with high agreement ranging from 86% to 100%. CONCLUSIONS Our study showed that data abstracted from medical records are reliable. Investigating intra-rater and inter-rater reliability can give confidence to draw conclusions from the abstracted data and increase data quality by minimizing systematic errors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wydział Biologii: Instytut Antropologii

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the great challenges of the scientific community on theories of genetic information, genetic communication and genetic coding is to determine a mathematical structure related to DNA sequences. In this paper we propose a model of an intra-cellular transmission system of genetic information similar to a model of a power and bandwidth efficient digital communication system in order to identify a mathematical structure in DNA sequences where such sequences are biologically relevant. The model of a transmission system of genetic information is concerned with the identification, reproduction and mathematical classification of the nucleotide sequence of single stranded DNA by the genetic encoder. Hence, a genetic encoder is devised where labelings and cyclic codes are established. The establishment of the algebraic structure of the corresponding codes alphabets, mappings, labelings, primitive polynomials (p(x)) and code generator polynomials (g(x)) are quite important in characterizing error-correcting codes subclasses of G-linear codes. These latter codes are useful for the identification, reproduction and mathematical classification of DNA sequences. The characterization of this model may contribute to the development of a methodology that can be applied in mutational analysis and polymorphisms, production of new drugs and genetic improvement, among other things, resulting in the reduction of time and laboratory costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To establish the prevalence of refractive errors and ocular disorders in preschool and schoolchildren of Ibiporã, Brazil. Methods: A survey of 6 to 12-year-old children from public and private elementary schools was carried out in Ibiporã between 1989 and 1996. Visual acuity measurements were performed by trained teachers using Snellen's chart. Children with visual acuity <0.7 in at least one eye were referred to a complete ophthalmologic examination. Results: 35,936 visual acuity measurements were performed in 13,471 children. 1.966 children (14.59%) were referred to an ophthalmologic examination. Amblyopia was diagnosed in 237 children (1.76%), whereas strabismus was observed in 114 cases (0.84%). Cataract (n=17) (0.12%), chorioretinitis (n=38) (0.28%) and eyelid ptosis (n=6) (0.04%) were also diagnosed. Among the 614 (4.55%) children who were found to have refractive errors, 284 (46.25%) had hyperopia (hyperopia or hyperopic astigmatism), 206 (33.55%) had myopia (myopia or myopic astigmatism) and 124 (20.19%) showed mixed astigmatism. Conclusions: The study determined the local prevalence of amblyopia, refractive errors and eye disorders among preschool and schoolchildren.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate changes in retinal nerve fiber layer thickness as measured by scanning laser polarimetry (SLP) after the use of medication to reduce intraocular pressure (IOP) in glaucomatous or ocular hypertensive patients. METHODS: The authors prospectively enrolled 37 eyes of 37 patients in whom IOP was reduced by more than 25% after the use of medication. The images were obtained before and 15 to 30 days after the introduction of medication. The SLP parameters measured before and after the use of medication were compared using paired Student's t Test. RESULTS: The mean IOP was significantly reduced from 26.57±4.23 mmHg to 16.54 ±2.92 mmHg after the use of medication (p<0.05). None of the 10 SLP analyzed parameters was significantly affected by the reduction of IOP with medication (p>0.05). CONCLUSION: The retinal nerve fiber layer thickness, as measured by SLP, is not affected by the reduction of IOP with medication in patients with glaucoma or ocular hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The antibacterial effect of ozone (O3) has been described in the extant literature, but the role of O3 therapy in the treatment of certain types of infection remains controversial. OBJECTIVES: To evaluate the effect of intraperitoneal (i.p.) O3 application in a cecal ligation/puncture rat model on interleukins (IL-6, IL-10) and cytokine-induced neutrophil chemoattractant (CINC)-1 serum levels, acute lung injury and survival rates. METHODS: Four animal groups were used for the study: a) the SHAM group underwent laparotomy; b) the cecal ligation/puncture group underwent cecal ligation/puncture procedures; and c) the CLP+O2 and CLP+O3 groups underwent CLP+ corresponding gas mixture infusions (i.p.) throughout the observation period. IL-6, CINC-1 and IL-10 concentrations were determined by enzyme-linked immunosorbent assay (ELISA). Acute lung injury was evaluated with the Evans blue dye lung leakage method and by lung histology. P<0.05 was considered significant. RESULTS: CINC-1 was at the lowest level in the SHAM group and was lower for the CLP+O3 group vs. the CLP+O2 group and the cecal ligation/puncture group. IL-10 was lower for the SHAM group vs. the other three groups, which were similar compared to each other. IL-6 was lower for the SHAM group vs. all other groups, was lower for the CLP+O3 or CLP+O2 group vs. the cecal ligation/puncture group, and was similar for the CLP+O3 group vs. the CLP+O2 group. The lung histology score was lower for the SHAM group vs. the other groups. The Evans blue dye result was lower for the CLP+O3 group vs. the CLP+O2 group and the cecal ligation/puncture group but similar to that of the SHAM group. The survival rate for the CLP+O3 group was lower than for the SHAM group and similar to that for the other 2 groups (CLP and CLP+O2). CONCLUSION: Ozone therapy modulated the inflammatory response and acute lung injury in the cecal ligation/puncture infection model in rats, although there was no improvement on survival rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Identificar diferenciais intra-urbanos e fatores de risco na prevalência de baixo peso ao nascer. MÉTODOS: Foram utilizadas as informações das declarações de nascido vivo de mães residentes no município de São Paulo, obtidos do Sistema de Informação de Nascidos Vivos e Fundação Seade, para o período de 2002 e 2003, totalizando 368.980 nascidos vivos. Os endereços foram geo-referenciados em setores censitários e classificados em seis grupos de vulnerabilidade segundo o Índice Paulista de Vulnerabilidade Social. Para identificação dos possíveis fatores de risco empregou-se análise de regressão logística. RESULTADOS: Observou-se tendência de crescimento da prevalência de baixo peso ao nascer com aumento da vulnerabilidade (de 6,8% a 8,1%). Houve diferenças significativas entre os grupos quanto às características maternas, assistência pré-natal e da proporção de nascimentos de não pré-termo de baixo peso. No grupo de baixo peso não pré-termo, proxy da presença de retardo do crescimento intra-uterino, residir em áreas vulneráveis (1,29;1,17-1,43) e características socioeconômicas maternas desaforáveis, como mães adolescentes (1,13;1,04-1,22), baixa escolaridade (1,26;1,17-1,35) e elevada paridade (1,10;1,01-1,20) foram fatores de risco, assim como mães idosas (1,38;1,30-1,47), e sem companheiro (1,15;1,11-1,20). A ausência de pré-natal apresentou o maior risco de baixo peso para nascimentos de pré-termo (3,39;2,86-4,02) e não pré-termo (2,12;1,87-2,41). Houve redução de risco de baixo peso com o aumento de consultas de pré-natal para nascimentos de pré-termo e não pré-termo. CONCLUSÕES: Há diferenças de prevalência de baixo peso ao nascer segundo grupos de vulnerabilidade. A assistência pré-natal mostrou-se desigual segundo grupos de vulnerabilidade e seu elevado risco para o baixo peso ao nascer indica a importância de ampliar o acesso e qualidade dos serviços de saúde