Three-dimensional Doppler evaluation of single spherical samples from the placenta: intra- and interobserver reliability


Autoria(s): Martins, W. P.; Lima, J. C.; Welsh, A. W.; Araujo, E., Jr.; Miyague, A. H.; Filho, F. M.; Raine-Fenning, N. J.
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

05/11/2013

05/11/2013

2012

Resumo

Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Identificador

ULTRASOUND IN OBSTETRICS & GYNECOLOGY, HOBOKEN, v. 40, n. 2, supl. 2, Part 3, pp. 200-206, AUG, 2012

0960-7692

http://www.producao.usp.br/handle/BDPI/41580

10.1002/uog.11076

http://dx.doi.org/10.1002/uog.11076

Idioma(s)

eng

Publicador

WILEY-BLACKWELL

HOBOKEN

Relação

ULTRASOUND IN OBSTETRICS & GYNECOLOGY

Direitos

closedAccess

Copyright WILEY-BLACKWELL

Palavras-Chave #DOPPLER #PLACENTA #REPRODUCIBILITY OF RESULTS #ULTRASONOGRAPHY #FLOW PHANTOM EXPERIMENT #3D POWER DOPPLER #REPRODUCIBILITY #ANGIOGRAPHY #ULTRASOUND #VOLUME #VASCULARIZATION #VASCULATURE #ACQUISITION #PREGNANCIES #ACOUSTICS #OBSTETRICS & GYNECOLOGY #RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING