991 resultados para Inspiratory resistive load testing
Resumo:
A 1000-kgf resistive strain-gauge load cell has been developed for quality testing of rocket propellant grain. A 7075-T6 aluminum alloy has been used for the elastic column, in which 8 uniaxial, 120-Ω strain gauges have been bonded and connected to form a full Wheatstone bridge to detect the strain. The chosen geometry makes the transducer insensitive to moments and, also, to the temperature. Experimental tests using a universal testing machine to imposed compression force to the load cell have demonstrated that its behavior is linear, with sensitivity of 2.90 μV/kgf ± 0.34%, and negligible hysteresis. The designed force transducer response to a dynamic test has been comparable to that of a commercial load cell. © 2005 IEEE.
Resumo:
Introdução: A DPOC é uma doença respiratória prevenível e tratável, caracterizada por limitação persistente ao fluxo aéreo, hiperinsuflação e aprisionamento aéreo. A dispneia e a intolerância aos esforços, decorrentes destas alterações fisiopatológicas sofre influência de vários fatores. Dentre estes, o recrutamento e a sobrecarga imposta aos músculos inspiratórios e expiratórios são de fundamental importância, porém a participação destes ainda não foi completamente elucidada em diferentes gravidades da doença. Objetivos: O objetivo principal deste estudo foi avaliar a mecânica ventilatória, e o grau de recrutamento da musculatura inspiratória e expiratória na DPOC leve e grave, na condição de repouso e durante um teste máximo de exercício, comparado a um grupo de indivíduos saudáveis. Metodologia: Trata-se de um estudo transversal envolvendo 36 indivíduos, sendo 24 pacientes portadores de DPOC e 12 voluntários sadios. As avaliações foram divididas em 2 visitas. No D1, foram realizadas uma avaliação clínica, avaliação de dispneia (mMRC) e de qualidade de vida (SGRQ), além da prova de função pulmonar completa. Na 2ª visita, realizada com intervalo de 1 semana, foram avaliadas: as pressões respiratórias máximas estáticas por meio de métodos volitivos (PImax, PEmax, SNIP, Pes sniff, Pga sniff e Pdi sniff) e não volitivos (Twitch cervical bilateral e T10); avaliação da sincronia toracoabdominal por pletismografia de indutância; avaliação do recrutamento dos músculos inspiratórios e expiratórios ao repouso pela eletromiografia de superfície; e, posteriormente, um teste de exercício cardiopulmonar incremental para estudo de todas essas variáveis no esforço. Resultados: Foram avaliados 24 pacientes (12 leves e 12 graves) e 12 indivíduos saudáveis da mesma faixa etária. A maioria dos pacientes apresentava comprometimento significativo da qualidade de vida e os pacientes do grupo grave eram mais sintomáticos. A função pulmonar encontrava-se alterada na maioria dos pacientes. Destes, 79,2% apresentavam aprisionamento aéreo e 70,8% tinham redução da DLCO. Tais alterações foram semelhantes nos 2 grupos de pacientes. A força muscular estática medida por métodos volitivos e não volitivos estava reduzida nos 2 grupos e mostrou relação com o VEF1. No exercício, a dispneia foi o principal motivo para interrupção do teste em 70% dos pacientes. A HD esteve presente em 87,5% dos pacientes. O comportamento das pressões respiratórias foi significativamente diferente entre os 3 grupos. Os pacientes com DPOC apresentaram maior atividade diafragmática (Pdi) comparado aos controles e a participação da musculatura expiratória também foi maior neste grupo, principalmente nos graves. Apesar disso, os pacientes com DPOC apresentaram uma eficiência mecânica reduzida, ou seja, esse incremento da força muscular foi insuficiente para manter uma ventilação adequada para uma determinada carga. Com o aumento da demanda ventilatória, houve recrutamento precoce e progressivo dos músculos inspiratórios e expiratórios durante o exercício. O trabalho resistivo e o expiratório foram significativamente diferentes entre os controles e os pacientes com DPOC desde o início do exercício. Como consequência destas alterações, a intensidade da dispneia durante o TECP foi maior nos pacientes com DPOC (leve e grave) para a mesma carga e mesma ventilação-minuto (VE), quando comparada aos indivíduos do grupo-controle. Conclusões: O conjunto destes achados demonstra que o comprometimento dos músculos inspiratórios e expiratórios contribuiu significativamente para a dispneia e a intolerância ao exercício tanto no DPOC leve quanto no DPOC grave. E que este comprometimento pode não ser detectado com os testes máximos de força ao repouso
Resumo:
Damages during extreme wind events highlight the weaknesses of mechanical fasteners at the roof-to-wall connections in residential timber frame buildings. The allowable capacity of the metal fasteners is based on results of unidirectional component testing that do not simulate realistic tri-axial aerodynamic loading effects. The first objective of this research was to simulate hurricane effects and study hurricane-structure interaction at full-scale, facilitating better understanding of the combined impacts of wind, rain, and debris on inter-component connections at spatial and temporal scales. The second objective was to evaluate the performance of a non-intrusive roof-to-wall connection system using fiber reinforced polymer (FRP) materials and compare its load capacity to the capacity of an existing metal fastener under simulated aerodynamic loads. ^ The Wall of Wind (WoW) testing performed using FRP connections on a one-story gable-roof timber structure instrumented with a variety of sensors, was used to create a database on aerodynamic and aero-hydrodynamic loading on roof-to-wall connections tested under several parameters: angles of attack, wind-turbulence content, internal pressure conditions, with and without effects of rain. Based on the aerodynamic loading results obtained from WoW tests, sets of three force components (tri-axial mean loads) were combined into a series of resultant mean forces, which were used to test the FRP and metal connections in the structures laboratory up to failure. A new component testing system and test protocol were developed for testing fasteners under simulated triaxial loading as opposed to uni-axial loading. The tri-axial and uni-axial test results were compared for hurricane clips. Also, comparison was made between tri-axial load capacity of FRP and metal connections. ^ The research findings demonstrate that the FRP connection is a viable option for use in timber roof-to-wall connection system. Findings also confirm that current testing methods of mechanical fasteners tend to overestimate the actual load capacities of a connector. Additionally, the research also contributes to the development a new testing protocol for fasteners using tri-axial simultaneous loads based on the aerodynamic database obtained from the WoW testing. ^
Resumo:
Damages during extreme wind events highlight the weaknesses of mechanical fasteners at the roof-to-wall connections in residential timber frame buildings. The allowable capacity of the metal fasteners is based on results of unidirectional component testing that do not simulate realistic tri-axial aerodynamic loading effects. The first objective of this research was to simulate hurricane effects and study hurricane-structure interaction at full-scale, facilitating better understanding of the combined impacts of wind, rain, and debris on inter-component connections at spatial and temporal scales. The second objective was to evaluate the performance of a non-intrusive roof-to-wall connection system using fiber reinforced polymer (FRP) materials and compare its load capacity to the capacity of an existing metal fastener under simulated aerodynamic loads. The Wall of Wind (WoW) testing performed using FRP connections on a one-story gable-roof timber structure instrumented with a variety of sensors, was used to create a database on aerodynamic and aero-hydrodynamic loading on roof-to-wall connections tested under several parameters: angles of attack, wind-turbulence content, internal pressure conditions, with and without effects of rain. Based on the aerodynamic loading results obtained from WoW tests, sets of three force components (tri-axial mean loads) were combined into a series of resultant mean forces, which were used to test the FRP and metal connections in the structures laboratory up to failure. A new component testing system and test protocol were developed for testing fasteners under simulated tri-axial loading as opposed to uni-axial loading. The tri-axial and uni-axial test results were compared for hurricane clips. Also, comparison was made between tri-axial load capacity of FRP and metal connections. The research findings demonstrate that the FRP connection is a viable option for use in timber roof-to-wall connection system. Findings also confirm that current testing methods of mechanical fasteners tend to overestimate the actual load capacities of a connector. Additionally, the research also contributes to the development a new testing protocol for fasteners using tri-axial simultaneous loads based on the aerodynamic database obtained from the WoW testing.
Resumo:
Peer reviewed
Resumo:
This paper reports the application of linearly increasing stress testing (LIST) to the study of stress corrosion cracking (SCC) of carbon steel in 4 N NaNO3 and in Bayer liquor. LIST is similar to the constant extension-rate testing (CERT) methodology with the essential difference that the LIST is load controlled whereas the CERT is displacement controlled. The main conclusion is that LIST is suitable for the study of the SCC of carbon steels in 4 N NaNO3 and in Bayer liquor. The low crack velocity in Bayer liquor and a measured maximum stress close to that of the reference specimen in air both indicate that a low applied stress rate is required to study SCC in this system. (C) 1998 Chapman & Hall.
Resumo:
Background and objective: Hyperinflation with a decrease in inspiratory capacity (IC) is a common presentation for both unstable and stable COPD patients. As CPAP can reduce inspiratory load, possibly secondary to a reduction in hyperinflation, this study examined whether CPAP would increase IC in stable COPD patients. Methods: Twenty-one stable COPD patients (nine emphysema, 12 chronic bronchitis) received a trial of CPAP for 5 min at 4, 7 and 11 cmH(2)O. Fast and slow VC (SVC) were measured before and after each CPAP trial. In patients in whom all three CPAP levels resulted in a decreased IC, an additional trial of CPAP at 2 cmH(2)O was conducted. For each patient, a `best CPAP` level was defined as the one associated with the greatest IC. This pressure was then applied for an additional 10 min followed by spirometry. Results: Following application of the `best CPAP`, the IC and SVC increased in 15 patients (nine emphysema, six chronic bronchitis). The mean change in IC was 159 mL (95% CI: 80-237 mL) and the mean change in SVC was 240 mL (95% CI: 97-386 mL). Among these patients, those with emphysema demonstrated a mean increase in IC of 216 mL (95% CI: 94-337 mL). Six patients (all with chronic bronchitis) did not demonstrate any improvement in IC. Conclusions: The best individualized CPAP can increase inspiratory capacity in patients with stable COPD, especially in those with emphysema.
Resumo:
Breast cancer accounts for approximately one quarter of all cancers in females. HER2 gene amplification or HER2 protein overexpression, detected in about 20% of breast carcinomas, predicts a more aggressive clinical course and determines eligibility for targeted therapy with trastuzumab. HER2 testing has become an essential part of the clinical evaluation of all breast carcinoma patients, and accurate HER2 results are critical in identifying patients who may be benefited from targeted therapy. This study investigated the concordance in the results of HER2 immunohistochemistry assays performed in 500 invasive breast carcinomas between a reference laboratory and 149 local laboratories from all geographic regions of Brazil. Our results showed an overall poor concordance (171 of 500 cases, 34.2%) regarding HER2 results between local and reference laboratories, which may be related to the low-volume load of HER2 assays, inexperience with HER2 scoring system, and/or technical issues related to immunohistochemistry in local laboratories. Standardization of HER2 testing with rigorous quality control measures by local laboratories is highly recommended to avoid erroneous treatment of breast cancer patients.
Resumo:
This study evaluated the influence of adhesive layer thickness (ADL) on the resin-dentin bond strength of two adhesive systems (AS) after ther-mal and mechanical loading (TML). A flat superficial dentin surface was exposed with 600-grit SiC paper on 40 molars. After primer application, the adhesive layer of Scotchbond Multipurpose (SBMP) or Clearfil SE Bond (CSEB) was applied in one or two layers to a delimited area (52 mm(2)) and resin blocks (Filtek 2250) were built incrementally: Half of the sample was stored in distilled water (37 C, 24 hours) and submitted to thermal (1,000; 5 degrees-55 degrees C) and mechanical cycles (500,000; 10kgf) [TML]. The other half was stored in distilled water (72 hours). The teeth were then sectioned to obtain sticks (0.8 mm(2)) to be tested under tensile mode (1.0 mm/minute). The fracture mode was analyzed at 400x. The BS from all sticks from the same tooth was averaged for statistical purposes. The data was analyzed by three-way ANOVA. The x(2) test was used (p<0.05) to compare the frequency of pre-testing failure specimens. Higher BS values were observed for SBMP regardless of the ADL. The TML reduced the BS values irrespective of the adhesive employed and the ADL. A higher frequency of pre-testing failure specimens was observed for the cycled groups. A thicker adhesive layer, acting as an intermediate flexible layer, did not min-imize the damage caused by thermal/mechanical load cycling for a three-step etch-and-rinse and two-step self-etch system.
Resumo:
Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.
Resumo:
P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.
Resumo:
Electricity short-term load forecast is very important for the operation of power systems. In this work a classical exponential smoothing model, the Holt-Winters with double seasonality was used to test for accurate predictions applied to the Portuguese demand time series. Some metaheuristic algorithms for the optimal selection of the smoothing parameters of the Holt-Winters forecast function were used and the results after testing in the time series showed little differences among methods, so the use of the simple local search algorithms is recommended as they are easier to implement.
Resumo:
Electricity short-term load forecast is very important for the operation of power systems. In this work a classical exponential smoothing model, the Holt-Winters with double seasonality was used to test for accurate predictions applied to the Portuguese demand time series. Some metaheuristic algorithms for the optimal selection of the smoothing parameters of the Holt-Winters forecast function were used and the results after testing in the time series showed little differences among methods, so the use of the simple local search algorithms is recommended as they are easier to implement.
Resumo:
Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.
Resumo:
The method used by YAGYU et al. for the subtype-specific polymerase chain reaction (PCR) amplification of the gp41 transmembrane region of the human immunodeficiency virus type-1 (HIV-1) env gene, was tested. HIV-1 proviral DNA from 100 infected individuals in Itajaí, South Brazil was used to analyze this method. Seventy individuals were determined according to this method as having PCR products at the expected size for subtypes B, C, D and F. Of these individuals, 26 (37.1%) were observed as having the expected amplification for subtype C, and 42 (60%) were observed as having the expected products for subtypes B and D. Of the subtype B and D amplicons, 16 (22.9%) were classified as subtype D, and 26 (37.1%) were classified as subtype B. Two individuals (2.9%) had amplicons that were observed after subtype F-specific amplification was performed. Sequencing and comparing the patient sequences to reference sequences confirmed the classification of sequences of subtypes C and B. However, sequences that were falsely determined as being D and F in the PCR assay were determined as being subtypes C and B, respectively, by sequence analysis. For those individuals from whom no amplified products were obtained, a low viral load that was indicated in their patient history may explain the difficulty in subtyping by PCR methods. This issue was demonstrated by the results of ANOVA when testing the effect of viral load on the success of PCR amplification. The alignment of the obtained sequences with HIV-1 reference sequences demonstrated that there is high intra-subtype diversity. This indicates that the subtype-specific primer binding sites were not conserved or representative of the subtypes that are observed in the Brazilian populations, and that they did not allow the correct classification of HIV-1 subtypes. Therefore, the proposed method by YAGYU et al. is not applicable for the classification of Brazilian HIV-1 subtypes.