213 resultados para 99mTc-Timina


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Área de especialização: Radiofarmácia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ischemia and reperfusion of the small intestine disrupts gut barrier, causes bacterial translocation and activates inflammatory responses. An experimental study was planned to evaluate if 99mTc labelled Escherichia coli translocates to mesenteric lymph nodes, liver, spleen, lung and serum of rats submitted to mesenteric ischemia/reperfusion. Additionally, it was observed if the time of reperfusion influences the level of translocation. METHODS: Forty male Wistar rats underwent 45 minutes of gut ischemia by occlusion of the superior mesenteric artery. The translocation of labelled bacteria to different organs and portal serum was determined in rats reperfused for 30 minutes, 24 hours, sham(S) and controls(C), using radioactivity count and colony forming units/g (CFU). RESULTS: All the organs from rats observed for 24 hours after reperfusion had higher levels of radioactivity and positive cultures (CFU) than did the organs of rats reperfused for 30 minutes, C and S, except in the spleen (p<0,01). CONCLUSION: The results of this study indicated that intestinal ischemia/reperfusion led to bacterial translocation, mostly after 24 hours of reperfusion

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate if the splenectomy alters the biodistribution of 99mTc-DMSA and renal function in Wistar rats. The animals were separated in the groups: splenectomy (n = 6) and control (n = 6). After splenectomy (15 days), the administration of 0.1ml of 99mTc-DMSA IV (0.48 MBq) was carried out. Thirty minutes later, kidney, heart, lung, thyroid, stomach, bladder and femur and samples of blood were isolated. The organs were weighed, counted and the percentage of radioactivity -g (%ATI-g) determined. Serum urea and creatinine, hematocrit, leukocytes and platelets were measured. Statistics by t test (p<0.05) was done. There was a significant reduction in %ATI-g in kidney and blood (p<0.05) of splenectomized animals, a significant increase (p<0.05) of urea (88.8 ± 18.6 mg-dL) and creatinine (0.56 ± 0.08 mg-dL), compared to the controls (51.5±1.6, 0.37±0.02mg-dL, respectively), as well as increase in platelets and leucocytes, and hematocrit reduction. The analysis of the results indicates that in rats, splenectomy seems to alter the renal function and the uptake of 99mTc-DMSA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Olanzapine, an atypical antipsychotic drug, was administered to a patient with Huntington's disease (HD) with marked choreiform movements. Brain SPECT with 99mTc-HMPAO was performed before and after treatment. Brain SPECT imaging has been performed in patients with HD in order to determine the status of basal ganglia perfusion. The use of brain SPECT with 99mTc-HMPAO before and after treatment in patients with HD has not been yet reported. The marked hypoperfusion of the basal ganglia on brain SPECT performed before therapy with olanzapine improved significantly after treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fibrodysplasia ossificans progressiva is a rare genetic disease characterized by widespread soft tissue ossification and congenital stigmata of the extremities. We report on a male child followed for ten years since the age of 3 years and 9 months, when the diagnosis was made. He was born with bilateral hypoplasic hallux valgus and ventricular septal defect, corrected by transsternal approach when 32 months old. Restriction of neck mobility followed and foci of ectopic ossification appeared. Four crises of disease exacerbation were treated with oral prednisone and/or other antiinflammatory drugs. Sodium etidronate 5 to 10 mg/kg/day was prescribed intermittently during about six years but was discontinued due to osteopenia. The disease course has been relentless, with severe movement restriction including the chest wall. A review showed few similar case reports in the Brazilian literature. We revisit the criteria for diagnosis and the essentials of management and treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gender-related differences in gastric emptying are still controversial. The aims of this study were: to confirm the sex-related difference in gastric emptying of a solid meal and to investigate its association with different patterns of meal distribution between the proximal and distal gastric compartments. Eighteen healthy volunteers (nine males, mean age 35 ± 9 years; nine females, mean age: 41 ± 11 years) were studied in the morning, after ingestion of the solid test-meal (an omelette labeled with 185MBq of 99mTc-sulfur colloid). Simultaneous anterior and posterior images of the stomach were acquired immediately after ingestion of the meal and every 10 minutes for 120 minutes. Time versus activity curves were obtained for the whole, proximal and distal stomach. Gastric T½ was longer in women (96.1 ± 17.2 min) than in men (79.9 ± 17.8 min; P = 0.02). The analysis of the meal distribution inside the stomach showed no differences between males and females in proximal gastric emptying, but the meal retention in the distal compartment was significantly increased among women (P = 0.04). In conclusion, gastric emptying of a solid meal is slower in pre-menopausal women than in age-matched men, probably due to an increased retention of the meal in the distal compartment. This should be taken into consideration to avoid misleading diagnosis of gastroparesis for female patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A avaliação da função pulmonar em cães pode ser obtida mediante exames cintilográficos, os quais incluem a injeção de radiofármacos, seguida de radiografias. Neste estudo, foram utilizados 10 cães machos hígidos da raça Rottweiler e radiograficamente normais e soronegativos para dirofilariose, com administração de doses variadas de macroagregado de albumina sérica humana marcados com tecnécio-99m ([99mTc](MAA)). Os resultados foram avaliados qualitativa e quantitativamente, considerando o índice de perfusão pulmonar e sua homogeneidade, sendo dessa maneira visualizado um aumento na homogeneidade da imagem diretamente relacionado ao número de partículas de MAA injetado. Este estudo define os critérios de normalidade e de dosagem na perfusão pulmonar em cães hígidos da raça Rottweiller estabelecidos com a técnica de cintilografia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiac sympathetic denervation and ventricular arrhythmia are frequently observed in chronic Chagas cardiomyopathy (CCC). This study quantitatively evaluated the association between cardiac sympathetic denervation and sustained ventricular tachycardia (SVT) in patients with CCC. Methods: We prospectively investigated patients with CCC and left ventricular ejection fraction (LVEF) greater than 35% with SVT (SVT group: n = 5 15; mean age +/- SD, 61 +/- 8 y; LVEF, 51% +/- 8%) and patients without SVT (non-SVT group: n = 11; mean age +/- SD, 55 +/- 10 y; LVEF, 57% +/- 10%). Patients underwent myocardial scintigraphy with (123)I-metaiodobenzylguanidine ((123)I-MIBG) for the evaluation of sympathetic innervation and resting perfusion with (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) for the evaluation of myocardial viability. A visual semiquantitative score was attributed for regional uptake of each radiotracer using a 17-segment left ventricular segmentation model (0, normal; 4, absence of uptake). A mismatch defect was defined as occurring in segments with a 99mTc-MIBI uptake score of 0 or 1 and a (123)I-MIBG score of 2 or more. Results: Compared with the non-SVT group, the SVT group had a similar (99m)Tc-MIBI summed score (6.9 +/- 7.5 vs. 4.4 +/- 5.2, respectively, P = 0.69) but a higher (123)I-MIBG summed score (10.9 +/- 7.8 vs. 22.4 +/- 9.5, respectively, P = 0.007) and a higher number of mismatch defects per patient (2.0 +/- 2.2 vs. 7.1 +/- 2.0, respectively, P < 0.0001). The presence of more than 3 mismatch defects was strongly associated with the presence of SVT (93% sensitivity, 82% specificity; P = 0.0002). Conclusion: In CCC, the amount of sympathetically denervated viable myocardium is associated with the occurrence of SVT. Myocardial sympathetic denervation may participate in triggering malignant ventricular arrhythmia in CCC patients with relatively well-preserved ventricular function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Renal scintigraphy with 99mTc-dimercaptosuccinic acid (99mTc-DMSA) is performed with the aim of detect cortical abnormalities related to urinary tract infection and accurately quantify relative renal function (RRF). For this quantitative assessment Nuclear Medicine Technologist should draw regions of interest (ROI) around each kidney (KROI) and peri-renal background (BKG) ROI, although, controversy still exists about BKG-ROI. The aim of this work was to evaluate the effect of the normalization procedure, number and location of BKG-ROI on the RRF in 99mTc-DMSA scintigraphy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem de perfusão do miocárdio por tomografia computorizada de emissão de fotão único (SPECT, do acrónimo inglês Single Photon Emission Computed Tomography) é um dos exames complementares de diagnóstico mais indicados na cardiologia clínica. Os dois agentes tecneciados mais utilizados são o 99mTc-tetrofosmina e o 99mTc-sestamibi. Estes permitem avaliar a distribuição do fluxo sanguíneo no músculo cardíaco. O mecanismo de fixação é idêntico nos dois radiofármacos (RF’s). São excretados, do organismo, a partir do sistema hepatobiliar para o duodeno e para o intestino. Assim, o RF está presente tanto no coração como nos órgãos adjacentes. O coração encontra-se localizado sobre o diafragma, logo acima do lobo esquerdo do fígado e nas proximidades do estômago. Deste modo, os fotões difusos provenientes desses órgãos podem interferir com a interpretação das imagens SPECT, principalmente na parede inferior do ventrículo esquerdo, traduzindo-se na redução da razão alvo-fundo e na qualidade da imagem. Deste modo, a sensibilidade e a especificidade da Cintigrafia de Perfusão do Miocárdio (CPM) diminuem. Têm sido descritos na literatura vários métodos e técnicas para minimizar o efeito da actividade extra-miocárdica, como: a aquisição de imagens mais tardias, a ingestão de líquidos ou alimentos ricos em lípidos. Outras técnicas apontam para a alteração do posicionamento do paciente durante a aquisição. Assim, o objectivo deste estudo é identificar o protocolo da CPM a nível nacional e avaliar a percentagem de repetições de exames provocadas pela interferência de actividade extra-miocárdica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Renal scintigraphy with 99mTc-dimercaptosuccinic acid (99mTc-DMSA) is performed with the aim of detect cortical abnormalities related to urinary tract infection and accurately quantify relative renal function (RRF). For this quantitative assessment Nuclear Medicine Technologist should draw regions of interest (ROI) around each kidney (KROI) and peri-renal background (BKG) ROI although controversy still exists about BKG-ROI. The aim of this work was to evaluate the effect of the normalization procedure, number and location of BKG-ROI on the RRF in 99mTc-DMSA scintigraphy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Área de especialização: Radiofarmácia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado, Biotecnologia em Controlo Biológico, 27 de Junho de 2013, Universidade dos Açores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective - To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform. Material and methods - Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of 99mTc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann–Whitney–Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal–Wallis test to assess simulation accuracy for this parameter. Results - There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30cm) with energy windows of 126–154 keV and 130–158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126–154 keV and 130–158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval. Conclusions - Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.