960 resultados para Reinforced concrete sandwich panels
Resumo:
Objectives. To test the null hypothesis that continuity of resin cement/dentin interfaces is not affected by location along the root canal walls or water storage for 3 months when bonding fiber posts into root canals. Methods. Fiber posts were luted to bovine incisors using four resinous luting systems: Multilink, Variolink II, Enforce Dual and Enforce PV. After cementation, roots were longitudinally sectioned and epoxy resin replicas were prepared for SEM analysis (baseline). The original halves were immersed in solvent, replicated and evaluated. After 3 months water storage and a second solvent immersion, a new set of replicas were made and analyzed. The ratio (%) between the length (mm) of available bonding interface and the actual extension of bonded cement/dentin interface was calculated. Results. Significant lower percent values of bond integrity were found for Multilink (8.25%) and Variolink 11 (10.08%) when compared to Enforce Dual (25.11%) and Enforce PV (27.0%) at baseline analysis. The same trend was observed after immersion in solvent, with no significant changes. However, bond integrity was significantly reduced after 3 months water storage and a second solvent immersion to values below 5% (Multilink = 3.31%, Variolink=1.87%, Enforce Dual=1.20%, and Enforce PV=0.75%). The majority of gaps were depicted at the apical and middle thirds at baseline and after immersion in solvent. After 3 months, gaps were also detected at the cervical third. Significance. Bond integrity at the cement/dentin interface was surprisingly low after cementation of fiber posts to root canals with all resin cements. That was not significantly altered after immersion in solvent, but was further compromised after 3 months water storage. Gaps were mainly seen at middle and apical thirds throughout the experiment and extended to the cervical third after water storage for 3 months. Bond integrity of fiber posts luted to root canals was affected both by location and water storage. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Introduction: A common complication during the restoration of severely destroyed teeth is the loss of coronal root dentine. The aim of this study was to evaluate the influence of different sealers on the bonding interface of weakened roots reinforced with resin and fiber posts. Methods: Sixty extracted maxillary canines were used. The crowns were removed, and the thickness of root dentine was reduced in the experimental (n = 40) and positive control (n = 10) groups. The specimens of experimental group were assigned to four subgroups (n = 10) according to the filling material: gutta-percha + Grossmann`s sealer, gutta-percha + AH Plus (Dentsply De Trey Gmbh, Konstanz, Germany), gutta-percha + Epiphany (Pentron Clinical Technologies, Wallingford, CT), and Resilon (Resilon Research LLC, Madison, CT) + Epiphany. In the negative control group (n = 10), canals were not filled. After post space preparation, the roots were restored with composite resin light-activated through a translucent fiber post. After 24 hours, specimens were transversally sectioned into 1-mm-thick slices. Push-out test and scanning electron microscopic (SEM) analyses of different regions were performed. Data from push-out test were analyzed by using Tukey post hoc multiple comparison tests. The percentage of failure type was calculated. Data from SEM analysis were compared by Friedman and Kruskal-Wallis tests (alpha = 0.05). Results: The mean bond strength was significantly higher in the negative control group as compared with the other groups (P < .05). In all groups, the most frequent type of failure was adhesive. Overall, apical and middle regions presented a lower density of resin tags than the coronal region (P < .05). Conclusions: The push-out bond strength was not affected by sealer or region. The canal region affected significantly the resin tag morphology and density at the bonding interface. (J Endod 2011;37:531-537)
Resumo:
Deterioration of concrete or reinforcing steel through excessive contaminant concentration is often the result of repeated wetting and drying cycles. At each cycle, the absorption of water carries new contaminants into the unsaturated concrete. Nuclear Magnetic Resonance (NMR) is used with large concrete samples to observe the shape of the wetting profile during a simple one-dimensional wetting process. The absorption of water by dry concrete is modelled by a nonlinear diffusion equation with the unsaturated hydraulic diffusivity being a strongly nonlinear function of the moisture content. Exponential and power functions are used for the hydraulic diffusivity and corresponding solutions of the diffusion equation adequately predict the shape of the experimental wetting profile. The shape parameters, describing the wetting profile, vary little between different blends and are relatively insensitive to subsequent re-wetting experiments allowing universal parameters to be suggested for these concretes.
Resumo:
The variation of the physical properties of four differ- ent carbon nanofibers (CNFs), based-polymer nano- composites incorporated in the same polypropylene (PP) matrix by twin-screw extrusion process was investigated. Nanocomposites fabricated with CNFs with highly graphitic outer layer revealed electrical isolation-to-conducting behaviors as function of CNF’s content. Nanocomposites fabricated with CNFs with an outer layer consisting on a disordered pyro- litically stripped layer, in contrast, revealed better mechanical performance and enhanced thermal sta- bility. Further, CNF’s incorporation into the polymer increased the thermal stability and the degree of crystallinity of the polymer, independently on the filler content and type. In addition, dispersion of the CNFs’ clusters in PP was analyzed by transmitted light opti- cal microscopy, and grayscale analysis (GSA). The results showed a correlation between the filler concentration and the variance, a parameter which measures quantitatively the dispersion, for all composites. This method indicated a value of 1.4 vol% above which large clusters of CNFs cannot be dispersed effectively and as a consequence only slight changes in mechanical performance are observed. Finally, this study establishes that for tailoring the physical properties of CNF based-polymer nanocomposites, both adequate CNFs structure and content have to be chosen.
Resumo:
The majority of worldwide structures use concrete as its main material. This happens because concrete is economically feasible, due to its undemanding production technology and case Of use. However, it is widely recognized that concrete production has a strong environmental impact in the planet. Natural aggregates use is one of the most important problems of concrete production nowadays, since they are obtained from limited, and in some countries scarce, resources. In Portugal, although there are enough stone quarries to cover coarse aggregates needs for several more years, Supplies of fine aggregates are becoming scarcer, especially in the northern part of the country. On the other hand, as concrete structures' life cycle comes to an end, an urgent need emerges to establish technically and economically viable solutions for demolition debris, other than for use as road base and quarry fill. This paper presents a partial life cycle assessment (LCA) of concrete made with fine recycled concrete aggregates performed with EcoConcrete tool. EcoConcrete is a tailor-made, interactive, learning and communications tool promoted by the Joint Project Group (JPG) on the LCA of concrete, to qualify and quantify the overall environment impact of concrete products. It consists of an interactive Excel-spreadsheet in which several environmental inputs (material quantities, distances from origin to production Site, production processes) and outputs (material, energy, emissions to air, water, soil or waste) are collected in a life cycle inventory, and are then processed to determine the environmental impact (assessment) of the analysed concrete, in terms of ozone layer depletion, smog or "greenhouse" effect.
Resumo:
Este Trabalho refere-se ao Projecto de Execução de Fundações e Estruturas de uma Ponte Rodoviária em betão armado pré-esforçado, realizado no âmbito do Trabalho Final de Mestrado em Engenharia Civil – Especialização em Estruturas, do Instituto Superior de Engenharia de Lisboa. O Projecto de Execução é composto de Peças Escritas e Peças Desenhadas. Nas Peças Escritas estão incluídos: Memória Justificativa e Descritiva; Cálculos Justificativos e Anexos. A ponte é composta por dois tabuleiros paralelos com 10,28m de largura cada um e afastados entre si de 0,10m. A obra é constituída de 8 tramos; os tramos correntes com 31m de comprimento e os tramos extremos com 25 e 20m de comprimento, perfazendo um comprimento total de 231m. A obra foi parcialmente isolada dos sismos pela introdução, em todos os pilares, de aparelhos de apoio de elevado amortecimento sísmico do tipo HDRB (High Damping Rubber Bearings). Encontram-se particularmente discriminadas e detalhadas neste projecto as seguintes situações: - Cálculo do Pré-esforço e respectivas perdas; - Acção das sobrecargas rodoviárias; - Diferença de comportamento da obra na entrada em serviço e no longo prazo; - Análise sísmica e do isolamento sísmico; - Estudo dos efeitos diferidos: retracção e fluência. Tendo as abordagens de cálculo e as verificações de segurança seguido a regulamentação nacional em vigor, nomeadamente RSA e REBAP, foi no entanto feita uma aproximação às regras do “Capacity Design” previstas no EC8, em que se privilegia a actuação do projectista sobre o comportamento da estrutura, procurando uma resposta não linear da mesma, visando garantir que: - A rotura não ocorrerá nos elementos de fundação; - Nos pilares a dissipação de energia se faz através de rótulas plásticas, evitando-se roturas associadas a esforços transversos. A aplicação destas regras neste Projecto demonstrou haver um agravamento substancial na definição dos esforços a que devem resistir alguns dos componentes da estrutura, designadamente os pilares e as fundações, originando soluções de secções de betão e armaduras bem mais exigentes do que aqueles que resultariam da simples verificação de segurança, pela comparação entre esforços actuante e esforços resistentes “secção a secção”, imposta pela actual regulamentação nacional.
Resumo:
This paper presents the results from an experimental study of the technical viability of two mixture designs for self-consolidating concrete (SCC) proposed by two Portuguese researchers in a previous work. The objective was to find the best method to provide the required characteristics of SCC in fresh and hardened states without having to experiment with a large number of mixtures. Five SCC mixtures, each with a volume of 25 L (6.61 gal.) were prepared using a forced mixer with a vertical axis for each of three compressive strength targets: 40, 55, and 70 MPa (5.80, 7.98, and 10.15 ksi). The mixtures' fresh state properties of fluidity, segregation resistance ability, and bleeding and blockage tendency, and their hardened state property of compressive strength were compared. For this study, the following tests were performed. slump-flow, V-funnel, L-box, box, and compressive strength. The results of this study made it possible to identify the most influential factors in the design of the SCC mixtures.
Resumo:
O objectivo deste trabalho consiste na elaboração de um projecto de estruturas de um edifício, desde a fase de concepção estrutural até à fase de pormenorização, passando obviamente pelo dimensionamento. O trabalho foi motivo para aplicação dos conhecimentos adquiridos durante o curso, na prática de projecto de estruturas, nomeadamente na utilização da regulamentação europeia de estruturas que está para entrar em vigor. O projecto foi elaborado a partir do projecto base de arquitectura e diz respeito a um conjunto de 4 edifícios de habitação separados por junta de dilatação, a construir em Lisboa. A estrutura em betão armado constituída por lajes fungiformes maciças apoiadas em pilares, paredes de betão e vigas, foi analisada com recurso a um programa de cálculo automático de elementos finitos SAP 200 V14.2.4. Para a execução deste trabalho recorreu-se à regulamentação europeia, nomeadamente o Eurocódigo 0, o Eurocódigo 1, o Eurocódigo 2 e o Eurocódigo 8, na sua versão final de Norma Portuguesa. Os critérios de dimensionamento bem como as disposições construtivas relativas a armaduras de betão são detalhadamente referidos ao longo do trabalho. Embora a análise estrutural tenha sido efectuada para quatro edifícios, os desenhos de pormenorização de betão armado são apresentados relativamente apenas ao edifício Nº1. Optou-se por esta solução em virtude de os edifícios serem semelhantes.
Resumo:
O presente trabalho foi realizado no âmbito do Trabalho Final de Mestrado em Engenharia Civil do Instituto Superior de Engenharia de Lisboa. O trabalho consistiu em realizar um Projecto de Execução de uma Passagem Superior com três tramos em Betão Armado e Pré-Esforçado. Foram tidos em conta os condicionamentos da topografia local, geotécnica e de traçado. O dimensionamento dos elementos estruturais foi efectuado de acordo com a regulamentação portuguesa actualmente em vigor, nomeadamente o Regulamento de Segurança e Acções (RSA) e o Regulamento de Estruturas de Betão Armado e Pré-esforçado (REBAP). A verificação da segurança foi efectuada em relação aos Estados Limites Últimos e de Utilização. Para a análise estrutural foi utilizado o programa de cálculo automático SAP2000.
Resumo:
Com a crescente divulgação no mercado português de métodos construtivos de alvenaria resistente tipo Termoargila, compara-se neste trabalho a sua rentabilidade económica, em relação à execução em betão armado, com paredes não estruturais de alvenaria. Estudam-se três tipologias de estruturas com geometria regular (1 piso, 2 pisos, 4 pisos), em zonas sísmicas A e D segundo o Regulamento de Segurança e Acções. A análise dos resultados permite verificar a eficiência dos métodos construtivos para cada tipologia de edifício, assim como os seus custos. Analisa-se se o motivo pelo qual em Portugal não é corrente a aplicação de soluções estruturais de alvenaria resistente tipo Termoargila, se unicamente económico ou se existe uma inércia dos intervenientes na construção, privilegiando os métodos construtivos tradicionais.
Resumo:
In smart grids context, the distributed generation units based in renewable resources, play an important rule. The photovoltaic solar units are a technology in evolution and their prices decrease significantly in recent years due to the high penetration of this technology in the low voltage and medium voltage networks supported by governmental policies and incentives. This paper proposes a methodology to determine the maximum penetration of photovoltaic units in a distribution network. The paper presents a case study, with four different scenarios, that considers a 32-bus medium voltage distribution network and the inclusion storage units.
Resumo:
Research on the use of Construction and Demolition Waste (CDW) as recycled aggregate (in particular crushed concrete) for the production of new concrete has by now established the feasibility of this environmentally-friendly use of otherwise harmful waste. However, contrary to conventional concrete (CC), no large applications of concrete made with recycled concrete have been made and there is still a lack of knowledge in some areas of production and performance of recycled aggregate concrete (RAC). One issue concerns curing conditions: these greatly affect the performance of concrete made on site and some potential users of RAC wonder how RAC is affected by far-from-ideal curing conditions. This paper shows the main results of experiments to determine the influence of different curing conditions on the mechanical performance of concrete made with coarse recycled aggregate from crushed concrete. The properties analyzed include compressive strength, splitting tensile strength, modulus of elasticity, and abrasion resistance. The general conclusion in terms of mechanical performance is that RAC is affected by curing conditions roughly in the same way as CC. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Functionally graded materials are composite materials wherein the composition of the constituent phases can vary in a smooth continuous way with a gradation which is function of its spatial coordinates. This characteristic proves to be an important issue as it can minimize abrupt variations of the material properties which are usually responsible for localized high values of stresses, and simultaneously providing an effective thermal barrier in specific applications. In the present work, it is studied the static and free vibration behaviour of functionally graded sandwich plate type structures, using B-spline finite strip element models based on different shear deformation theories. The effective properties of functionally graded materials are estimated according to Mori-Tanaka homogenization scheme. These sandwich structures can also consider the existence of outer skins of piezoelectric materials, thus achieving them adaptive characteristics. The performance of the models, are illustrated through a set of test cases. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
This paper deals with the coupled effect of temperature and silica fume addition on rheological, mechanical behaviour and porosity of grouts based on CEMI 42.5R, proportioned with a polycarboxylate-based high range water reducer. Preliminary tests were conducted to focus on the grout best able to fill a fibrous network since the goal of this study was to develop an optimized grout able to be injected in a mat of steel fibers for concrete strengthening. The grout composition was developed based on criteria for fresh state and hardened state properties. For a CEMI 42.5R based grout different high range water reducer dosages (0%, 0.2%, 0.4%, 0.5%, 0.7%) and silica fume (SF) dosages (0%, 2%, 4%) were tested (as replacement of cement by mass). Rheological measurements were used to investigate the effect of polycarboxylates (PCEs) and SF dosage on grout properties, particularly its workability loss, as the mix was to be injected in a matrix of steel fibers for concrete jacketing. The workability behaviour was characterized by the rheological parameters yield stress and plastic viscosity (for different grout temperatures and resting times), as well as the procedures of mini slump cone and funnel flow time. Then, further development focused only on the best grout compositions. The cement substitution by 2% of SF exhibited the best overall behaviour and was considered as the most promising compared to the others compositions tested. Concerning the fresh state analysis, a significant workability loss was detected if grout temperature increased above 35 degrees C. Below this temperature the grout presented a self-levelling behaviour and a life time equal to 45 min. In the hardened state, silica fumes increased not only the grout's porosity but also the grout's compressive strength at later ages, since the pozzolanic contribution to the compressive strength does not occur until 28 d and beyond. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
This paper addresses the problem of optimal positioning of surface bonded piezoelectric patches in sandwich plates with viscoelastic core and laminated face layers. The objective is to maximize a set of modal loss factors for a given frequency range using multiobjective topology optimization. Active damping is introduced through co-located negative velocity feedback control. The multiobjective topology optimization problem is solved using the Direct MultiSearch Method. An application to a simply supported sandwich plate is presented with results for the maximization of the first six modal loss factors. The influence of the finite element mesh is analyzed and the results are, to some extent, compared with those obtained using alternative single objective optimization. (C) 2013 Elsevier Ltd. All rights reserved.