SEM observation of the bond integrity of fiber-reinforced composite posts cemented into root canals


Autoria(s): BONFANTE, Estevam A.; PEGORARO, Luiz F.; GOES, Mario R. de; CARVALHO, Ricardo M.
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2008

Resumo

Objectives. To test the null hypothesis that continuity of resin cement/dentin interfaces is not affected by location along the root canal walls or water storage for 3 months when bonding fiber posts into root canals. Methods. Fiber posts were luted to bovine incisors using four resinous luting systems: Multilink, Variolink II, Enforce Dual and Enforce PV. After cementation, roots were longitudinally sectioned and epoxy resin replicas were prepared for SEM analysis (baseline). The original halves were immersed in solvent, replicated and evaluated. After 3 months water storage and a second solvent immersion, a new set of replicas were made and analyzed. The ratio (%) between the length (mm) of available bonding interface and the actual extension of bonded cement/dentin interface was calculated. Results. Significant lower percent values of bond integrity were found for Multilink (8.25%) and Variolink 11 (10.08%) when compared to Enforce Dual (25.11%) and Enforce PV (27.0%) at baseline analysis. The same trend was observed after immersion in solvent, with no significant changes. However, bond integrity was significantly reduced after 3 months water storage and a second solvent immersion to values below 5% (Multilink = 3.31%, Variolink=1.87%, Enforce Dual=1.20%, and Enforce PV=0.75%). The majority of gaps were depicted at the apical and middle thirds at baseline and after immersion in solvent. After 3 months, gaps were also detected at the cervical third. Significance. Bond integrity at the cement/dentin interface was surprisingly low after cementation of fiber posts to root canals with all resin cements. That was not significantly altered after immersion in solvent, but was further compromised after 3 months water storage. Gaps were mainly seen at middle and apical thirds throughout the experiment and extended to the cervical third after water storage for 3 months. Bond integrity of fiber posts luted to root canals was affected both by location and water storage. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Identificador

DENTAL MATERIALS, v.24, n.4, p.483-491, 2008

0109-5641

http://producao.usp.br/handle/BDPI/26100

10.1016/j.dental.2007.04.010

http://dx.doi.org/10.1016/j.dental.2007.04.010

Idioma(s)

eng

Publicador

ELSEVIER SCI LTD

Relação

Dental Materials

Direitos

restrictedAccess

Copyright ELSEVIER SCI LTD

Palavras-Chave #fiber-reinforced composite post #resin cements #bonding #scanning electron microscopy #bond integrity #ENDODONTICALLY-TREATED TEETH #SIMPLIFIED-STEP ADHESIVES #DUAL-CURED COMPOSITES #DENTAL COMPOSITES #PERMEABLE MEMBRANES #CLINICAL CONDITIONS #RESIN COMPOSITE #SINGLE-BOTTLE #STRENGTH #POLYMERIZATION #Dentistry, Oral Surgery & Medicine #Materials Science, Biomaterials
Tipo

article

original article

publishedVersion