997 resultados para Laser-Assisted CVD
Resumo:
A laser-based technique for printing transparent and weakly absorbing liquids is developed. Its principle of operation relies in the tight focusing of short laser pulses inside the liquid and close to its free surface, in such a way that the laser radiation is absorbed in a tiny volume around the beam waist, with practically no absorption in any other location along the beam path. If the absorbed energy overcomes the optical breakdown threshold, a cavitation bubble is generated, and its expansion results in the propulsion of a small fraction of liquid which can be collected on a substrate, leading to the printing of a microdroplet for each laser pulse. The technique does not require the preparation of the liquid in thin film form, and its forward mode of operation imposes no restriction concerning the optical properties of the substrate. These characteristics make it well suited for printing a wide variety of materials of interest in diverse applications. We demonstrate that the film-free laser forward printing technique is capable of printing microdroplets with good resolution, reproducibility and control, and analyze the influence of the main process parameter, laser pulse energy. The mechanisms of liquid printing are also investigated: time-resolved imaging provides a clear picture of the dynamics of liquid transfer which allows understanding the main features observed in the printed droplets.
Resumo:
The expansion dynamics of the ablation plume generated by KrF laser irradiation of hydroxyapatite targets in a 0.1 mbar water atmosphere has been studied by fast intensified charge coupled device imaging with the aid of optical bandpass filters. The aim of the filters is to isolate the emission of a single species, which allows separate analysis of its expansion. Images obtained without a filter revealed two emissive components in the plume, which expand at different velocities for delay times of up to 1.1 ¿s. The dynamics of the first component is similar to that of a spherical shock wave, whereas the second component, smaller than the first, expands at constant velocity. Images obtained through a 520 nm filter show that the luminous intensity distribution and evolution of emissive atomic calcium is almost identical to those of the first component of the total emission and that there is no contribution from this species to the emission from the second component of the plume. The analysis through a 780 nm filter reveals that atomic oxygen partially diffuses into the water atmosphere and that there is a contribution from this species to the emission from the second component. The last species studied here, calcium oxide, was analyzed by means of a 600 nm filter. The images revealed an intensity pattern more complex than those from the atomic species. Calcium oxide also contributes to the emission from the second component. Finally, all the experiments were repeated in a Ne atmosphere. Comparison of the images revealed chemical reactions between the first component of the plume and the water atmosphere.
Resumo:
Epitaxial thin films of Y¿doped SrZrO3 have been grown on MgO(001) by pulsed laser deposition. The deposition process has been performed at temperatures of 1000¿1200¿°C and at an oxygen pressure of 1.5×10¿1 mbar. The samples are characterized by Rutherford backscattering spectrometry/channeling (RBS/C) and x¿ray diffraction (XRD). We found an epitaxial relationship of SrZrO3 (0k0) [101]¿MgO (001) [100]. Good crystalline quality is confirmed by RBS/C minimum yield values of 9% and a FWHM of 0.35° of the XRD rocking curve.
Resumo:
In this study, we have performed magneto-optical Kerr effect (MOKE) measurement on epitaxial La2/3Sr1/3MnO3 thin films containing artificial interfaces created by laser-patterning the SrTiO3 substrate. The observed increase of the resistivity and of the high-field magnetoresistance when measuring the films across the interface arrays are related to the reduction of the magnetization of the interfaces with respect to the rest of the film. As observed by the local MOKE probe, the structural disorder in the manganite film induced by the underlying patterned substrate leads to a large spin disorder responsible for a strong high-field susceptibility of the resistance.
Resumo:
Laser-induced forward transfer (LIFT) is a laser direct-write technique that offers the possibility of printing patterns with a high spatial resolution from a wide range of materials in a solid or liquid state, such as conductors, dielectrics, and biomolecules in solution. This versatility has made LIFT a very promising alternative to lithography-based processes for the rapid prototyping of biomolecule microarrays. Here, we study the transfer process through the LIFT of droplets of a solution suitable for microarray preparation. The laser pulse energy and beam size were systematically varied, and the effect on the transferred droplets was evaluated. Controlled transfers in which the deposited droplets displayed optimal features could be obtained by varying these parameters. In addition, the transferred droplet volume displayed a linear dependence on the laser pulse energy. This dependence allowed determining a threshold energy density value, independent of the laser focusing conditions, which acted as necessary conditions for the transfer to occur. The corresponding sufficient condition was given by a different total energy threshold for each laser beam dimension. The threshold energy density was found to be the dimensional parameter that determined the amount of the transferred liquid per laser pulse, and there was no substantial loss of material due to liquid vaporization during the transfer.
Resumo:
Time-resolved imaging is carried out to study the dynamics of the laser-induced forward transfer of an aqueous solution at different laser fluences. The transfer mechanisms are elucidated, and directly correlated with the material deposited at the analyzed irradiation conditions. It is found that there exists a fluence range in which regular and well-defined droplets are deposited. In this case, laser pulse energy absorption results in the formation of a plasma, which expansion originates a cavitation bubble in the liquid. After the further expansion and collapse of the bubble, a long and uniform jet is developed, which advances at a constant velocity until it reaches the receptor substrate. On the other hand, for lower fluences no material is deposited. In this case, although a jet can be also generated, it recoils before reaching the substrate. For higher fluences, splashing is observed on the receptor substrate due to the bursting of the cavitation bubble. Finally, a discussion of the possible mechanisms which lead to such singular dynamics is also provided.
Resumo:
The substrate tuning technique was applied to a radio frequency magnetron sputtering system to obtain a variable substrate bias without an additional source. The dependence of the substrate bias on the value of the external impedance was studied for different values of chamber pressure, gas composition and rf input power. A qualitative explanation of the results is given, based on a simple model, and the role of the stray capacitance is clearly disclosed. Langmuir probe measurements show that this system allows independent control of the ion flux and the ion energy bombarding the growing film. For an argon flow rate of 2.8 sccm and a radio frequency power of 300 W (intermediate values of the range studied) the ion flux incident on the substrate was 1.3 X 1020-m-2-s-1. The maximum ion energy available in these conditions can be varied in the range 30-150 eV. As a practical application of the technique, BN thin films were deposited under different ion bombardment conditions. An ion energy threshold of about 80 eV was found, below which only the hexagonal phase was present in the films, while for higher energies both hexagonal and cubic phase were present. A cubic content of about 60% was found for an ion energy of 120 V.
Resumo:
Coalescing compact binary systems are important sources of gravitational waves. Here we investigate the detectability of this gravitational radiation by the recently proposed laser interferometers. The spectral density of noise for various practicable configurations of the detector is also reviewed. This includes laser interferometers with delay lines and Fabry-Prot cavities in the arms, both in standard and dual recycling arrangements. The sensitivity of the detector in all those configurations is presented graphically and the signal-to-noise ratio is calculated numerically. For all configurations we find values of the detector's parameters which maximize the detectability of coalescing binaries, the discussion comprising Newtonian- as well as post-Newtonian-order effects. Contour plots of the signal-to-noise ratio are also presented in certain parameter domains which illustrate the interferometer's response to coalescing binary signals.
Resumo:
Polycrystalline Ni-Mn-Ga thin films have been deposited by the pulsed laser deposition (PLD) technique, using slices of a Ni-Mn-Ga single crystal as targets and onto Si (100) substrates at temperatures ranging from 673 K up to 973 K. Off-stoichiometry thin films were deposited at a base pressure of 1×10-6-Torr or in a 5 mTorr Ar atmosphere. Samples deposited in vacuum and temperatures above 823 K are magnetic at room temperature and show the austenitic {220} reflection in their x-ray diffraction patterns. The temperature dependences of both electrical resistance and magnetic susceptibility suggest that these samples exhibit a structural martensitic transition at around 260 K. The magnetoresistance ratio at low temperature can be as high as 1.3%, suggesting the existence of a granular structure in the films
Resumo:
Résumé : Introduction : L'objectif de cette étude était d'une part d'évaluer les caractéristiques histologiques des fragments cellulaires rétiniens attachés à la limitante interne après vitrectomie et pelage d'une membrane epirétinienne, et d'autre part de mettre en évidence des différences histologiques entre les cas opérés avec ou sans l'aide d'ICG dilué dans du glucose 5%. Méthodes Nous avons examiné rétrospectivement l'histologie de 88 spécimens de membranes épimaculaires contenant la limitante interne de la rétine, qui ont été enlevés chirurgicalement entre 1995 et 2003. L'analyse histologique a centré principalement l'attention sur la présence et les caractéristiques des fragments cellulaires rétiniens attachés à la limitante interne. L'analyse statistique a comparé les résultats entre le groupe I (chirurgie conventionnelle sans l'aide de l'ICG) et le groupe II (chirurgie à l'aide de l'ICG). Résultats Soixante et onze patients ont eu une vitrectomie sans l'aide de l'ICG (groupe I) et 17 avec l'aide de l'ICG (groupe II). Le nombre de débris de cellules de Müller à la surface rétinienne de la limitante interne était plus important dans le groupe I (sans ICG) que dans le groupe II (avec ICG) (40.8% versus 11.8% ; p = 0.024). Des larges fragments cellulaires rétiniens attachés à la limitante interne ont été plus fréquemment observés dans le groupe I (sans ICG) que dans le groupe II (avec ICG) (63.4% versus 23.5%; p= 0.003). Dans cinq (7%) cas du groupe I, de gros éléments cellulaires rétiniens ont été mis en évidence (des axones neuraux ou des vaisseaux sanguins). De tels éléments n'ont pas été retrouvés dans les spécimens du groupe II (avec ICG). Conclusions L'utilisation de l'ICG dilué dans du glucose 5% pour faciliter le pelage d'une membrane épimaculaire et notamment l'ablation de la limitante interne de la rétine semble diminuer de manière significative le nombre et la taille des débris des cellules de Muller adhérents à la face rétinienne de la membrane limitante interne de la rétine. Cette observation suggère que l'utilisation per-opératoire d'ICG dilué dans du glucose 5% facilite l'ablation de la limitante interne pendant la chirurgie de la membrane epirétinienne en diminuant l'adhérence de la limitante interne à la rétine.
Resumo:
Two methods of differential isotopic coding of carboxylic groups have been developed to date. The first approach uses d0- or d3-methanol to convert carboxyl groups into the corresponding methyl esters. The second relies on the incorporation of two 18O atoms into the C-terminal carboxylic group during tryptic digestion of proteins in H(2)18O. However, both methods have limitations such as chromatographic separation of 1H and 2H derivatives or overlap of isotopic distributions of light and heavy forms due to small mass shifts. Here we present a new tagging approach based on the specific incorporation of sulfanilic acid into carboxylic groups. The reagent was synthesized in a heavy form (13C phenyl ring), showing no chromatographic shift and an optimal isotopic separation with a 6 Da mass shift. Moreover, sulfanilic acid allows for simplified fragmentation in matrix-assisted laser desorption/ionization (MALDI) due the charge fixation of the sulfonate group at the C-terminus of the peptide. The derivatization is simple, specific and minimizes the number of sample treatment steps that can strongly alter the sample composition. The quantification is reproducible within an order of magnitude and can be analyzed either by electrospray ionization (ESI) or MALDI. Finally, the method is able to specifically identify the C-terminal peptide of a protein by using GluC as the proteolytic enzyme.