997 resultados para Hunter, C. Roy
Resumo:
This study explores a large set of OC and EC measurements in PM(10) and PM(2.5) aerosol samples, undertaken with a long term constant analytical methodology, to evaluate the capability of the OC/EC minimum ratio to represent the ratio between the OC and EC aerosol components resulting from fossil fuel combustion (OC(ff)/EC(ff)). The data set covers a wide geographical area in Europe, but with a particular focus upon Portugal, Spain and the United Kingdom, and includes a great variety of sites: urban (background, kerbside and tunnel), industrial, rural and remote. The highest minimum ratios were found in samples from remote and rural sites. Urban background sites have shown spatially and temporally consistent minimum ratios, of around 1.0 for PM(10) and 0.7 for PM(2.5).The consistency of results has suggested that the method could be used as a tool to derive the ratio between OC and EC from fossil fuel combustion and consequently to differentiate OC from primary and secondary sources. To explore this capability, OC and EC measurements were performed in a busy roadway tunnel in central Lisbon. The OC/EC ratio, which reflected the composition of vehicle combustion emissions, was in the range of 03-0.4. Ratios of OC/EC in roadside increment air (roadside minus urban background) in Birmingham, UK also lie within the range 03-0.4. Additional measurements were performed under heavy traffic conditions at two double kerbside sites located in the centre of Lisbon and Madrid. The OC/EC minimum ratios observed at both sites were found to be between those of the tunnel and those of urban background air, suggesting that minimum values commonly obtained for this parameter in open urban atmospheres over-predict the direct emissions of OC(ff) from road transport. Possible reasons for this discrepancy are explored. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
OBJETIVO: A prevalência da infecção pelo vÃrus da hepatite C (VHC) é maior em pacientes submetidos à hemodiálise que na população em geral, possivelmente refletindo maior exposição a situações de risco. O estudo realizado teve por objetivo determinar a prevalência de anticorpos anti-VHC em pacientes em hemodiálise e identificar fatores relacionados à s clÃnicas e aos pacientes, associados à transmissão do VHC. MÉTODOS: Realizou-se estudo transversal em 752 pacientes em hemodiálise em todas as 12 clÃnicas de Fortaleza, Ceará. Eles foram testados com anticorpos anti-VHC por ELISA de terceira geração. Foram entrevistados 663 pacientes quanto a aspectos sociodemográficos, clÃnicos e epidemiológicos. Fatores nosocomiais foram investigados utilizando-se questionário especÃfico. Para a análise estatÃstica foram aplicados o teste t de Student, o odds ratio e a regressão logÃstica univariada e multivariada. RESULTADOS: A prevalência de anti-VHC foi de 52% (390/746; variando de 6% a 72%). A freqüência de infecção foi maior em pacientes previamente submetidos à diálise peritoneal (OR=1,76; IC 95% 1,12-2,76) e a transfusões de sangue (OR=2,75; IC 95% 1,25-6,03). O tempo de hemodiálise associou-se com positividade do anti-VHC (OR=1,47; IC 95% 1,35-1,61). Procedimentos nas clÃnicas associados à positividade do anti-VHC foram preparo prévio de heparina (OR=2,92; IC 95% 1,23-6,92), falha no uso ou troca de luvas (OR=5,73; IC 95% 1,75-18,72), desinfecção de máquinas de diálise (OR=2,79; IC 95% 1,57-4,96) e segregação em sala de diálise (OR=0,18; IC 95% 0,05-0,61). CONCLUSÕES: Os resultados mostraram elevada prevalência de anti-VHC em pacientes sob hemodiálise e a associação de fatores de transmissão nosocomial com a infecção pelo VHC.
Resumo:
Os pacientes com doença hemato-oncológica submetidos a quimioterapia possuem maior propensão para infecções bacterianas. O seu diagnóstico pode ser efectuado recorrendo-se aos marcadores biológicos: procalcitonina (PCT) e proteÃna C reactiva (PCR). Neste estudo, observaram-se diferenças estatisticamente significativas na concentração de PCT nos diferentes grupos de infecção, o que não se verificou na concentração de PCR. Observou-se ainda uma fraca correlação entre estes marcadores nos grupos de infecção. Apenas os valores de PCT estão directamente relacionados com a gravidade da infecção, evidenciando-o como um bom marcador de diagnóstico, mais eficaz do que a PCR.
Resumo:
Mestrado em Fiscalidade
Resumo:
OBJECTIVE: To describe the opinion of doctors who participated in the Latin American Study on Cesarean section in Brazil regarding the second opinion strategy when faced with the decision of performing a C-section. METHODS: Seventy-two doctors from the hospitals where the study took place (where the second opinion was routinely sought) and 70 from the control group answered a pre-tested self-administered structured questionnaire. Descriptive tables were prepared based on the frequency of relevant variables on opinion of physicians regarding: effectiveness of the application of the second opinion strategy; on whether they would recommend implementation of this strategy and reasons for not recommending it in private institutions; feasibility of the strategy implementation and reasons for not considering this implementation feasible in private institutions. RESULTS: Half of the doctors from the intervention hospitals (50%) and about two thirds of those in the control group (65%) evaluated the second opinion as being or having the potential of being effective/very effective in their institutions. The great majority of those interviewed from both intervention and control hospitals considered this strategy feasible in public (87% and 95% respectively) but not in private hospitals (64% and 70% respectively), mainly because in the latter the doctors would not accept interference from a colleague in their decision-making process. CONCLUSION: Although the second opinion strategy was perceived as effective in reducing C-section rates, doctors did not regard it feasible outside the public health system in Brazil.
Resumo:
OBJETIVO: Os vÃrus da imunodeficiência humana e o vÃrus da hepatite C apresentam fatores de transmissão em comum. Atualmente, há alta freqüência da co-infecção, principalmente em indivÃduos usuários de drogas injetáveis e com história de transfusões. O objetivo do estudo foi avaliar os fatores de risco para infecção pelo HIV em pacientes infectados pelo vÃrus da hepatite C. MÉTODOS: Trata-se de estudo epidemiológico do tipo caso-controle, realizado com 118 pacientes (casos) infectados pelos vÃrus HIV e vÃrus da hepatite C e 233 pacientes (controles) infectados somente pelo vÃrus da hepatite C. Entre janeiro de 1999 a novembro de 2001, os pacientes foram submetidos a questionário sobre caracterÃsticas sociodemográficas, profissionais, e principais fatores de risco para infecção pelos vÃrus. Após descritas e comparadas, as variáveis foram submetidas à análise univariada, e em seguida à análise de regressão logÃstica para variáveis selecionadas pelo teste da razão da máxima verossimilhança. RESULTADOS: A co-infecção está associada ao sexo feminino (OR=2,89; IC 95%: 1,16-7,08), aos estados civis separado/viúvo (OR=3,91; IC 95%: 1,34-11,35), ao uso pregresso ou atual de drogas ilÃcitas (OR=3,96; IC 95%: 1,55-0,13) e ao hábito de compartilhar canudos ou seringas (OR=10,28; IC 95%: 4,00-6,42). CONCLUSÕES: Em pacientes infectados pelo vÃrus da hepatite C, o sexo feminino é fator de risco para a infecção pelo HIV quando ajustado à variável compartilhar canudos ou seringas. Os estados civis separado/viúvo, uso de drogas ilÃcitas e hábito de compartilhar canudos ou seringas são, também, fatores associados ao risco para esta co-infecção.
Resumo:
Trabalho de natureza profissional para a atribuição do TÃtulo de Especialista do Instituto Politécnico do Porto, na área de Direito, defendido a 11-01-2013.
Resumo:
Combined tunable WDM converters based on SiC multilayer photonic active filters are analyzed. The operation combines the properties of active long-pass and short-pass wavelength filter sections into a capacitive active band-pass filter. The sensor element is a multilayered heterostructure produced by PE-CVD. The configuration includes two stacked SiC p-i-n structures sandwiched between two transparent contacts. Transfer function characteristics are studied both theoretically and experimentally. Results show that optical bias activated photonic device combines the demultiplexing operation with the simultaneous photodetection and self amplification of an optical signal acting the device as an integrated photonic filter in the visible range. Depending on the wavelength of the external background and irradiation side, the device acts either as a short- or a long-pass band filter or as a band-stop filter. The output waveform presents a nonlinear amplitude-dependent response to the wavelengths of the input channels. A numerical simulation and two building-blocks active circuit is presented and gives insight into the physics of the device.
Resumo:
The hydrotris(pyrazol-1-yl)methane iron(II) complex [FeCl2{eta(3)-HC(pz)(3)}] (Fe, pz = pyrazol-1-yl) immobilized on commercial (MOR) or desilicated (MOR-D) zeolite, catalyses the oxidation of cyclohexane with hydrogen peroxide to cyclohexanol and cyclohexanone, under mild conditions. MOR-D/Fe (desilicated zeolite supported [FeCl2{eta(3)-HC(pz)(3)}] complex) provides an outstanding catalytic activity (TON up to 2.90 x 10(3)) with the concomitant overall yield of 38%, and can be easy recovered and reused. The MOR or MOR-D supported hydrotris(pyrazol-1-yl)methane iron(II) complex (MOR/Fe and MOR-D/Fe, respectively) was characterized by X-ray powder diffraction, ICP-AES, and TEM studies as well as by IR spectroscopy and N-2 adsorption at -196 degrees C. The catalytic operational conditions (e.g., reaction time, type and amount of oxidant, presence of acid and type of solvent) were optimized. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Although global biodiversity is declining, local ecosystems are not systematically losing diversity, but rather experiencing rapid turnover in species.
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de NÃvel Superior (CAPES)
Resumo:
Gold(III) complexes of type [AuCl2{eta(2)-RC(R'pz)(3)}]Cl [R = R' = H (1), R = CH2OH, R' = H (2) and R = H, R' = 3,5-Me-2(3), pz = pyrazol-1-yl] were supported on carbon materials (activated carbon, carbon xerogel and carbon nanotubes) and used for the oxidation of cyclohexane to cyclohexanol and cyclohexanone, with aqueous H2O2, under mild conditions.
Resumo:
New studies are giving ecologists some hope of controlling red lionfish, a voracious predator that has invaded the Atlantic.