978 resultados para Electron beam tomography
Resumo:
The study of the effect of radiation on living tissues is a rather complex task to address mainly because they are made of a set of complex functional biological structures and interfaces. Particularly if one is looking for where damage is taking place in a first stage and what are the underlying reaction mechanisms. In this work a new approach is addressed to study the effect of radiation by making use of well identified molecular hetero-structures samples which mimic the biological environment. These were obtained by assembling onto a solid support deoxyribonucleic acid (DNA) and phospholipids together with a soft water-containing polyelectrolyte precursor in layered structures and by producing lipid layers at liquid/air interface with DNA as subphase. The effects of both ultraviolet (UV) radiation and carbon ions beams were systematically investigated in these heterostructures, namely damage on DNA by means vacuum ultraviolet (VUV), infrared (IR), X-Ray Photoelectron (XPS) and impedance spectroscopy. Experimental results revealed that UV affects furanose, PO2-, thymines, cytosines and adenines groups. The XPS spectrometry carried out on the samples allowed validate the VUV and IR results and to conclude that ionized phosphate groups, surrounded by the sodium counterions, congregate hydration water molecules which play a role of UV protection. The ac electrical conductivity measurements revealed that the DNA electrical conduction is arising from DNA chain electron hopping between base-pairs and phosphate groups, with the hopping distance equal to the distance between DNA base-pairs and is strongly dependent on UV radiation exposure, due loss of phosphate groups. Characterization of DNA samples exposed to a 4 keV C3+ ions beam revealed also carbon-oxygen bonds break, phosphate groups damage and formation of new species. Results from radiation induced damage carried out on biomimetic heterostructures having different compositions revealed that damage is dependent on sample composition, with respect to functional targeted groups and extent of damage. Conversely, LbL films of 1,2-dipalmitoyl-sn-Glycero-3-[Phospho-rac-(1-glycerol)] (Sodium Salt) (DPPG) liposomes, alternated with poly(allylamine hydrochloride) (PAH) revealed to be unaffected, even by prolonged UV irradiation exposure, in the absence of water molecules. However, DPPG molecules were damaged by the UV radiation in presence of water with cleavage of C-O, C=O and –PO2- bonds. Finally, the study of DNA interaction with the ionic lipids at liquid/air interfaces revealed that electrical charge of the lipid influences the interaction of phospholipid with DNA. In the presence of DNA in the subphase, the effects from UV irrladiation were seen to be smaller, which means that ionic products from biomolecules degradation stabilize the intact DPPG molecules. This mechanism may explain why UV irradiation does not cause immediate cell collapse, thus providing time for the cellular machinery to repair elements damaged by UV.
Resumo:
OBJECTIVE: The aims of this study were to evaluate the role of high resolution computed tomography of the torax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. METHOD: Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomographys separated by an interval of at least one year. RESULTS: All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomographys. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36%) patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of paraseptal emphysema was present on both scans. In 3 patients, a "mosaic" appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. CONCLUSIONS: We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis, namely bronchial dilatation, frequently resolve spontaneously. Therefore, the diagnosis of bronchiectasis by high resolution computed tomography in asthmatic patients must be made with caution, since bronchial dilatation can be reversible or can represent false dilatation. Nonsmoking chronic asthmatic subjects in this study had no evidence of centrilobular or panacinar emphysema.
Resumo:
PURPOSE: To report the experience of a radiology department in the use of computed tomography - guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. METHODS: This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). RESULTS: In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. CONCLUSION: The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules.
Resumo:
INTRODUCTION: Pleuropulmonary changes are common following coronary artery bypass grafting surgery performed with a saphenous vein graft, with or without an internal mammary artery. The presence of atelectasis or pleural effusions reflects the thoracic trauma. PURPOSE: To define the postoperative incidence of changes in the lung and in the pleural space and to evaluate the influence of the trauma. METHODS: Thirty patients underwent elective coronary artery bypass grafting surgery (8 saphenous vein grafts and 22 saphenous vein grafts and internal mammary artery grafts with pleurotomy). Chest tubes in the left pleural space were used in all internal mammary artery patients. On the second (day 2) and seventh (day 7) postoperative day, patients underwent a computed tomography, and pleural effusions were rated as follows: grade 0 = no fluid to grade 4 = fluid in more than 75% of the hemithorax. Atelectasis was rated as follows: laminar = 1, segmental = 3, and lobar = 10 points. RESULTS: All patients had pleural effusion or atelectasis. Between day 2 and day 7, the number of patients with effusions or atelectasis on the right side decreased (P < 0.05). The incidence of effusions on day 2 in the saphenous vein graft group (87.5%) was higher (P < 0.05) than in the internal mammary artery group (52.3%). The incidence of atelectasis in the lower right lobe decreased (P < 0.05) from 86.7% (day 2) to 26.7% (day 7). The degree of atelectasis in both sides did not differ on day 2 (P = 0.42) but did on day 7 (P < 0.0001). There was a decrease in the atelectasis from day 2 to day 7 on the right side (P < 0.001), but not on the left (P = 0.21). On day 2 there was a relationship between atelectasis and effusion on the right (P = 0.04), but not on the left (P = 0.113). CONCLUSION: The present series demonstrates that there is a high incidence of both minimal pleural effusion and atelectasis after coronary artery bypass grafting surgery, which drops on the right side from day 2 to day 7 post surgery. Factors that contribute to the persistence of changes on the left side include the thoracic trauma and the presence of chest tubes and pericardial effusion.
Resumo:
PURPOSE: To report the experience of a radiology department in the use of computed tomography guided biopsies of mediastinal lesions with fine and cutting needles, describing the differences between them. The results of adequacy of the sample and histologic diagnoses are presented according to the type of needle used. METHODS: We present a retrospective study of mediastinal biopsies guided by computed tomography performed from January 1993 to December 1999. Eighty-six patients underwent mediastinal biopsy in this period, 37 with cutting needles, 38 with fine needles, and 11 with both types (total of 97 biopsies). RESULTS: In most cases, it was possible to obtain an adequate sample (82.5%) and specific diagnosis (67.0%). Cutting-needle biopsy produced a higher percentage of adequate samples (89.6% versus 75.5%, P = 0.068) and of specific diagnosis (81.3% versus 53.1%, P = 0.003) than fine-needle biopsy. There were no complications that required intervention in either group. CONCLUSION: Because they are practical, safe, and can provide accurate diagnoses, image-guided biopsies should be considered the procedure of choice in the initial exploration of patients with mediastinal masses. In our experience, cutting needles gave higher quality samples and diagnostic rates. We recommend the use of cutting needles as the preferred procedure.
Resumo:
The thrust towards energy conservation and reduced environmental footprint has fueled intensive research for alternative low cost sources of renewable energy. Organic photovoltaic cells (OPVs), with their low fabrication costs, easy processing and flexibility, represent a possible viable alternative. Perylene diimides (PDIs) are promising electron-acceptor candidates for bulk heterojunction (BHJ) OPVs, as they combine higher absorption and stability with tunable material properties, such as solubility and position of the lowest unoccupied molecular orbital (LUMO) level. A prerequisite for trap free electron transport is for the LUMO to be located at a level deeper than 3.7 eV since electron trapping in organic semiconductors is universal and dominated by a trap level located at 3.6 eV. Although the mostly used fullerene acceptors in polymer:fullerene solar cells feature trap-free electron transport, low optical absorption of fullerene derivatives limits maximum attainable efficiency. In this thesis, we try to get a better understanding of the electronic properties of PDIs, with a focus on charge carrier transport characteristics and the effect of different processing conditions such as annealing temperature and top contact (cathode) material. We report on a commercially available PDI and three PDI derivatives as acceptor materials, and its blends with MEH-PPV (Poly[2-methoxy 5-(2-ethylhexyloxy)-1,4-phenylenevinylene]) and P3HT (Poly(3-hexylthiophene-2,5-diyl)) donor materials in single carrier devices (electron-only and hole-only) and in solar cells. Space-charge limited current measurements and modelling of temperature dependent J-V characteristics confirmed that the electron transport is essentially trap-free in such materials. Different blend ratios of P3HT:PDI-1 (1:1) and (1:3) show increase in the device performance with increasing PDI-1 ratio. Furthermore, thermal annealing of the devices have a significant effect in the solar cells that decreases open-circuit voltage (Voc) and fill factor FF, but increases short-circuit current (Jsc) and overall device performance. Morphological studies show that over-aggregation in traditional donor:PDI blend systems is still a big problem, which hinders charge carrier transport and performance in solar cells.
Resumo:
RESUMO: Este trabalho teve como objetivo a determinação de esquemas de tratamento alternativos para o carcinoma da próstata com radioterapia externa (EBRT) e braquiterapia de baixa taxa de dose (LDRBT) com implantes permanentes de Iodo-125, biologicamente equivalentes aos convencionalmente usados na prática clínica, com recurso a modelos teóricos e a métodos de Monte Carlo (MC). Os conceitos de dose biológica efetiva (BED) e de dose uniforme equivalente (EUD) foram utilizados, com o modelo linear-quadrático (LQ), para a determinação de regimes de tratamento equivalentes. Numa primeira abordagem, utilizou-se a BED para determinar: 1) esquemas hipofracionados de EBRT mantendo as complicações retais tardias de regimes convencionais com doses totais de 75,6 Gy, 77,4 Gy, 79,2 Gy e 81,0 Gy; e 2) a relação entre as doses totais de EBRT e LDRBT de modo a manter a BED do regime convencional de 45 Gy de EBRT e 110 Gy de LDRBT. Numa segunda abordagem, recorreu-se ao código de MC MCNPX para a simulação de distribuições de dose de EBRT e LDRBT em dois fantomas de voxel segmentados a partir das imagens de tomografia computorizada de pacientes com carcinoma da próstata. Os resultados das simulações de EBRT e LDRBT foram somados e determinada uma EUD total de forma a obterem-se: 1) esquemas equivalentes ao tratamento convencional de 25 frações de 1,8 Gy de EBRT em combinação com 110 Gy de LDRBT; e 2) esquemas equivalentes a EUD na próstata de 67 Gy, 72 Gy, 80 Gy, 90 Gy, 100 Gy e 110 Gy. Em todos os resultados nota-se um ganho terapêutico teórico na utilização de esquemas hipofracionados de EBRT. Para uma BED no reto equivalente ao esquema convencional, tem-se um aumento de 2% na BED da próstata com menos 5 frações. Este incremento dá-se de forma cada vez mais visível à medida que se reduz o número de frações, sendo da ordem dos 10-11% com menos 20 frações e dos 35-45% com menos 40 frações. Considerando os resultados das simulações de EBRT, obteve-se uma EUD média de 107 Gy para a próstata e de 42 Gy para o reto, com o esquema convencional de 110 Gy de LDRBT, seguidos de 25 frações de 1,8 Gy de EBRT. Em termos de probabilidade de controlo tumoral (igual EUD), é equivalente a este tratamento a administração de EBRT em 66 frações de 1,8 Gy, 56 de 2 Gy, 40 de 2,5 Gy, 31 de 3 Gy, 20 de 4 Gy ou 13 de 5 Gy. Relativamente à administração de 66 frações de 1,8 Gy, a EUD generalizada no reto reduz em 6% com o recurso a frações de 2,5 Gy e em 10% com frações de 4 Gy. Determinou-se uma BED total de 162 Gy para a administração de 25 frações de 1,8 Gy de EBRT em combinação com 110 Gy de LDRBT. Variando-se a dose total de LDRBT (TDLDRBT) em função da dose total de EBRT (TDEBRT), de modo a garantir uma BED de 162 Gy, obteve-se a seguinte relação:.......... Os resultados das simulações mostram que a EUD no reto diminui com o aumento da dose total de LDRBT para dose por fração de EBRT (dEBRT) inferiores a 2, Gy e aumenta para dEBRT a partir dos 3 Gy. Para quantidades de TDLDRBT mais baixas (<50 Gy), o reto beneficia de frações maiores de EBRT. À medida que se aumenta a TDLDRBT, a EUD generalizada no reto torna-se menos dependente da dEBRT. Este trabalho mostra que é possível a utilização de diferentes regimes de tratamento para o carcinoma da próstata com radioterapia que possibilitem um ganho terapêutico, quer seja administrando uma maior dose biológica com efeitos tardios constantes, quer mantendo a dose no tumor e diminuindo a toxicidade retal. A utilização com precaução de esquemas hipofracionados de EBRT, para além do benefício terapêutico, pode trazer vantagens ao nível da conveniência para o paciente e economia de custos. Os resultados das simulações deste estudo e conversão para doses de efeito biológico para o tratamento do carcinoma da próstata apresentam linhas de orientação teórica de interesse para novos ensaios clínicos. --------------------------------------------------ABSTRACT: The purpose of this work was to determine alternative radiotherapy regimens for the treatment of prostate cancer using external beam radiotherapy (EBRT) and low dose-rate brachytherapy (LDRBT) with Iodine-125 permanent implants which are biologically equivalent to conventional clinical treatments, by the use of theoretical models and Monte Carlo techniques. The concepts of biological effective dose (BED) and equivalent uniform dose (EUD), together with the linear-quadratic model (LQ), were used for determining equivalent treatment regimens. In a first approach, the BED concept was used to determine: 1) hypofractionated schemes of EBRT maintaining late rectal complications as with the conventional regimens with total doses of 75.6 Gy, 77.4 Gy, 79.2 Gy and 81.0 Gy; and 2) the relationship between total doses of EBRT and LDRBT in order to keep the BED of the conventional treatment of 45 Gy of EBRT and 110 Gy of LDRBT. In a second approach, the MC code MCNPX was used for simulating dose distributions of EBRT and LDRBT in two voxel phantoms segmented from the computed tomography of patients with prostate cancer. The results of the simulations of EBRT and LDRBT were added up and given an overall EUD in order to obtain: 1) equivalent to conventional treatment regimens of 25 fraction of 1.8 Gy of EBRT in combination with 110Gy of LDRBT; and 2) equivalent schemes of EUD of 67 Gy, 72 Gy, 80 Gy, 90 Gy, 100 Gy, and 110Gy to the prostate. In all the results it is noted a therapeutic gain using hypofractionated EBRT schemes. For a rectal BED equivalent to the conventional regimen, an increment of 2% in the prostate BED was achieved with less 5 fractions. This increase is visibly higher as the number of fractions decrease, amounting 10-11% with less 20 fractions and 35-45% with less 20 fractions. Considering the results of the EBRT simulations an average EUD of 107 Gy was achieved for the prostate and of 42 Gy for the rectum with the conventional scheme of 110 Gy of LDRBT followed by 25 fractions of 1.8 Gy of EBRT. In terms of tumor control probability (same EUD) it is equivalent to this treatment, for example, delivering the EBRT in 66 fractions of 1.8 Gy, 56 fractions of 2 Gy, 40 fractions of 2.5 Gy, 31 fractions of 3 Gy, 20 fractions of 4 Gy or 13 fractions of 5 Gy. Regarding the use of 66 fractions of 1.8 Gy, the rectum EUD is reduced to 6% with 2.5 Gy per fraction and to 10% with 4 Gy. A total BED of 162 Gy was achieved for the delivery of 25 fractions of 1.8 Gy of EBRT in combination with 110 Gy of LDRBT. By varying the total dose of LDRBT (TDLDRBT) with the total dose of EBRT (TDEBRT) so as to ensure a BED of 162 Gy, the following relationship was obtained: ....... The simulation results show that the rectum EUD decreases with the increase of the TDLDRBT, for EBRT dose per fracion (dEBRT) less than 2.5 Gy and increases for dEBRT above 3 Gy. For lower amounts of TDLDRBT (< 50Gy), the rectum benefits of larger EBRT fractions. As the TDLDRBT increases, the rectum gEUD becomes less dependent on the dEBRT. The use of different regimens which enable a therapeutic gain, whether deivering a higher dose with the same late biological effects or maintaining the dose to the tumor and reducing rectal toxicity is possible. The use with precaution of hypofractionated regimens, in addition to the therapeutic benefit, can bring advantages in terms of convenience for the patient and cost savings. The simulation results of this study together with the biological dose conversion for the treatment of prostate cancer serve as guidelines of interest for new clinical trials.
Resumo:
Simultaneous measurements of the tt¯, W+W−, and Z/γ∗→ττ production cross-sections using an integrated luminosity of 4.6 fb−1 of pp collisions at s√=7 TeV collected by the ATLAS detector at the LHC are presented. Events are selected with two high transverse momentum leptons consisting of an oppositely charged electron and muon pair. The three processes are separated using the distributions of the missing transverse momentum of events with zero and greater than zero jet multiplicities. Measurements of the fiducial cross-section are presented along with results that quantify for the first time the underlying correlations in the predicted and measured cross-sections due to proton parton distribution functions. These results indicate that the correlated NLO predictions for tt¯ and Z/γ∗→ττ significantly underestimate the data, while those at NNLO generally describe the data well. The full cross-sections are measured to be σ(tt¯)=181.2±2.8+9.7−9.5±3.3±3.3 pb, σ(W+W−)=53.3±2.7+7.3−8.0±1.0±0.5 pb, and σ(Z/γ∗→ττ)=1174±24+72−87±21±9 pb, where the cited uncertainties are due to statistics, systematic effects, luminosity and the LHC beam energy measurement, respectively.
Resumo:
This paper presents measurements from the ATLAS experiment of the forward-backward asymmetry in the reaction pp→Z/γ∗→l+l−, with l being electrons or muons, and the extraction of the effective weak mixing angle. The results are based on the full set of data collected in 2011 in pp collisions at the LHC at s√ = 7 TeV, corresponding to an integrated luminosity of 4.8 fb−1. The measured asymmetry values are found to be in agreement with the corresponding Standard Model predictions. The combination of the muon and electron channels yields a value of the effective weak mixing angle of 0.2308±0.0005(stat.)±0.0006(syst.)±0.0009(PDF), where the first uncertainty corresponds to data statistics, the second to systematic effects and the third to knowledge of the parton density functions. This result agrees with the current world average from the Particle Data Group fit.
Resumo:
We report on the growth and structural and morphologic characterization of stacked layers of self-assembled GeSn dots grown on Si (100) substrates by molecular beam epitaxy at low substrate temperature T = 350 °C. Samples consist of layers (from 1 up to 10) of Ge0.96Sn0.04 self-assembled dots separated by Si spacer layers, 10 nm thick. Their structural analysis was performed based on transmission electron microscopy, atomic force microscopy and Raman scattering. We found that up to 4 stacks of dots could be grown with good dot layer homogeneity, making the GeSn dots interesting candidates for optoelectronic device applications.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)
Resumo:
This work describes the influence of a high annealing temperature of about 700C on the Si(substrate)/Si3N4/TiOx/Pt/LiCoO2 multilayer system for the fabrication of all-solid-state lithium ion thin film microbatteries. Such microbatteries typically utilize lithium cobalt oxide (LiCoO2) as cathode material with a platinum (Pt) current collector. Silicon nitride (Si3N4) is used to act as a barrier against Li diffusion into the substrate. For a good adherence between Si3N4 and Pt, commonly titanium (Ti) is used as intermediate layer. However, to achieve crystalline LiCoO2 the multilayer system has to be annealed at high temperature. This post-treatment initiates Ti diffusion into the Pt-collector and an oxidation to TiOx, leading to volume expansion and adhesion failures. To solve this adhesion problem, we introduce titanium oxide (TiOx) as an adhesion layer, avoiding the diffusion during the annealing process. LiCoO2, Pt and Si3N4 layers were deposited by magnetron sputtering and the TiOx layer by thermal oxidation of Ti layers deposited by e-beam technique. Asdeposited and annealed multilayer systems using various TiOx layer thicknesses were studied by scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) and x-ray photoelectron spectroscopy (XPS). The results revealed that an annealing process at temperature of 700C leads to different interactions of Ti atoms between the layers, for various TiOx layer thicknesses (25–45 nm).