899 resultados para Diametral tensile strength


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work intends to know the most types of ignition systems, studying its history, the way it works, applications and some examples. The assembly of a distributor less ignition system is also required. All vehicles powered by internal combustion engines need an ignition system that allows this engine to ignite the air-fuel mixture using its ignition system in the best possible manner. The main goal of an ignition system is to obtain a spark having enough energy to start the chemical reaction of the oxygen and the fuel. It took a study dealing with the various types of ignition systems since their creation at the beginning of the last century until 2015. The work starts studying the high tension magneto ignition system and later together with the low tension ignition system, going on with the conventional ignition system and finally accomplishing with the various types of electronic ignition systems. It was studied and implemented an electronic circuit to power a double spark ignition system also known as wasted spark ignition system. This circuit was assembled with an electric pulse generator and powered mechanically by a dc electric motor of the variable rpm type

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study examined the immediate bond strength of etch-and-rinse adhesives to demineralized dentin saturated with either water or absolute ethanol. The research hypothesis was that there would be no difference in bond strength to dentin between water or ethanol wet-bonding techniques. The medium dentin of 20 third molars was exposed (n = 5). The dentin surface was then acid-etched, left moist and randomly assigned to be saturated via either water wet-bonding (WBT) or absolute ethanol wet-bonding (EBT). The specimens were then treated with one of the following etch-and-rinse adhesive systems: a 3-step, water-based system (Adper Scotchbond Multipurpose, or SBMP) or a 2-step, ethanol/water-based system (Adper Single Bond 2, or SB). Resin composite build-ups were then incrementally constructed. After water storage for 24 h at 37 degrees C, the tensile strength of the specimens was tested in a universal testing machine (0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey's test (alpha = 5%). The failure modes were verified using a stereomicroscope (40x). For both adhesives, no significant difference in bond strength was observed between WBT and EBT (p > 0.05). The highest bond strength was observed for SB, regardless of the bonding technique (p < 0.05). No significant interaction between adhesives and bonding techniques was noticed (p = 0.597). There was a predominance of adhesive failures for all tested groups. The EBT and WBT displayed similar immediate bond strength means for both adhesives. The SB adhesive exhibited higher means for all conditions tested. Further investigations are needed to evaluate long-term bonding to dentin mediated by commercial etch-and-rinse adhesives using the EBT approach.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Organic-inorganic composite membranes were prepared from membranes of the bio-polymer bacterial cellulose (BC) and organic-inorganic sal composed of nanoparticulate boehmite and epoxi modified siloxane. Bacterial cellulose membranes are obtained in a highly hydrated state (1% cellulose and 99% cellulose) from cultures of Gluconacetobacter xylinus and could be used in the never-dried or in the dried state. Depending on the use of dried or never-dried BC membranes two main kinds of composites were obtained. In the first one dried BC membranes coated with the hybrid sol have lead to transparent membranes displaying a hi-phase structure where the two components could be easily distinguished, with individual structures preserved. A decrease was observed for tensile strength (50.5 MPa) and Young's Modulus (2.8 GPa) when compared to pure BC membrane (112.5 MPa and 12.7 GPa). Elongation at break was observed to increase (2.5% against 1.5% observed for BC). When never-dried BC membranes were used transparent membranes were also obtained, however an improvement was observed for mechanical properties (tensile strength - 116 MPa and Young's Modulus - 13.7 GPa). A lower value was obtained for the elongation at break (1.3%). In the last case the interaction between the two-phases lead to changes in the cellulose crystallinity as shown by X rays diffraction results. Multifunctional transparent membranes displaying the cellulose structure in one side and the boehmite-siloxane structure at the opposite face could find special applications in opto-electronics or biomedical areas taking advantage of the different chemical nature of the two components. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C (6.43 +/- 3.24 mu m) when compared to Groups A (16.50 +/- 7.55 mu m) and B (16.27 +/- 1.71 mu m) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66 +/- 14.30 mu m; Group B, 39.4.8 +/- 12.03 mu m; Group C, 23.13 +/- 8.24 mu m) (P<.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks. [J Adv Prosthodont 2012;4:89-92]

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the tensile strength, elongation, microhardness, microstructure and fracture pattern of various metal ceramic alloys cast under different casting conditions. Two Ni-Cr alloys, Co-Cr and Pd-Ag were used. The casting conditions were as follows: electromagnetic induction under argon atmosphere, vacuum, using blowtorch without atmosphere control. For each condition, 16 specimens, each measuring 25 mm long and 2.5 mm in diameter, were obtained. Ultimate tensile strength (UTS) and elongation (EL) tests were performed using a Kratos machine. Vickers Microhardness (VM), fracture mode and microstructure were analyzed by SEM. UTS, EL and VM data were statistically analyzed using ANOVA. For UTS, alloy composition had a direct influence on casting condition of alloys (Wiron 99 and Remanium CD), with higher values shown when cast with Flame/Air (p < 0.05). The factors "alloy" and "casting condition" influenced the EL and VM results, generally presenting opposite results, i.e., alloy with high elongation value had lower hardness (Wiron 99), and casting condition with the lowest EL values had the highest VM values (blowtorch). Both factors had significant influence on the properties evaluated, and prosthetic laboratories should select the appropriate casting method for each alloy composition to obtain the desired property.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Surface treatment interferes with the primary stability of dental implants because it promotes a chemical and micromorphological change on the surface and thus stimulates osseointegration. This study aimed to evaluate the effects of different surface treatments on primary stability by analyzing insertion torque (IT) and pullout force (PF). Eight samples of implants with different surface treatments (TS - external hexagon with acid surface treatment; and MS - external hexagon, machined surface), all 3.75 mm in diameter x 11.5 mm in length, were inserted into segments of artificial bones. The IT of each sample was measured by an electronic torquemeter, and then the pullout test was done with a universal testing machine. The results were subjected to ANOVA (p < 0.05), followed by Tukey's test (p < 0.05). The IT results showed no statistically significant difference, since the sizes of the implants used were very similar, and the bone used was not highly resistant. The PF values (N) were, respectively, TS = 403.75 +/- 189.80 and MS = 276.38 +/- 110.05. The implants were shown to be different in terms of the variables of maximum force (F = 4.401, p = 0.0120), elasticity in maximum flexion (F = 3.672, p = 0.024), and relative stiffness (F = 4.60, p = 0.01). In this study, external hexagonal implants with acid surface treatment showed the highest values of pullout strength and better stability, which provide greater indication for their use.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this in vitro study was to compare the degradation of resin-dentin bonds of an etch-and-rinse adhesive system to primary and permanent teeth. Flat superficial coronal dentin surfaces from 5 primary second molars and 5 permanent third molars were etched with phosphoric acid and bonded with an adhesive system (Adper Single Bond 2, 3M ESPE). Blocks of resin composite (Z250, 3M ESPE) were built up and the teeth sectioned to produce bonded sticks with a 0.8 mm(2) cross-sectional area. The sticks of each tooth were randomly divided and assigned to be subjected to microtensile testing immediately (24 h) or after aging by water storage (6 months). Data were analyzed by two-way repeated measures ANOVA and Tukey post hoc test (alpha = 0.05). Failure mode was evaluated using a stereomicroscope (400x). Microtensile values significantly decreased after the 6 months aging, independent of the dentin substrate. In 24 h, the values obtained to primary dentin were lower compared with permanent dentin. This difference was not maintained after aging. Adhesive/mixed failure was predominant in all experimental groups. In conclusion, degradation of resin-dentin bonds of the etch-and-rinse adhesive system occurred after 6 months of water storage; however, the reduction in bond strength values was higher for permanent teeth.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this controlled animal study was to investigate the effect of low-level laser therapy (LLLT) administered 30 min after injury to the Achilles tendon. The study animals comprised 16 Sprague Dawley male rats divided in two groups. The right Achilles tendons were injured by blunt trauma using a mini guillotine, and were treated with LLLT or placebo LLLT 30 min later. The injury and LLLT procedures were then repeated 15 hours later on the same tendon. One group received active LLLT (lambda = 904 nm, 60 mW mean output power, 0.158 W/cm(2) for 50 s, energy 3 J) and the other group received placebo LLLT 23 hours after LLLT. Ultrasonographic images were taken to measure the thickness of the right and left Achilles tendons. Animals were then killed, and all Achilles tendons were tested for ultimate tensile strength (UTS). All analyses were performed by blinded observers. There was a significant increase in tendon thickness in the active LLLT group when compared with the placebo group (p < 0.05) and there were no significant differences between the placebo and uninjured left tendons. There were no significant differences in UTS between laser-treated, placebo-treated and uninjured tendons. Laser irradiation of the Achilles tendon at 0.158 W/cm(2) for 50 s (3 J) administered within the first 30 min after blunt trauma, and repeated after 15 h, appears to lead to edema of the tendon measured 23 hours after LLLT. The guillotine blunt trauma model seems suitable for inflicting tendon injury and measuring the effects of treatment on edema by ultrasonography and UTS. More studies are needed to further refine this model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A nanocomposite based on bacterial cellulose (BC) and type I collagen (COL) was evaluated for in vitro bone regeneration. BC membranes were modified by glycine esterification followed by cross-linking of type I collagen employing 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide. Collagen incorporation was studied by spectroscopy analysis. X-Ray diffraction showed changes in the BC crystallinity after collagen incorporation. The elastic modulus and tensile strength for BC-COL decreased, while the strain at failure showed a slight increase, even after sterilization, as compared to pristine BC. Swelling tests and contact angle measurements were also performed. Cell culture experiments performed with osteogenic cells were obtained by enzymatic digestion of newborn rat calvarium revealed similar features of cell morphology for cultures grown on both membranes. Cell viability/proliferation was not different between BC and BC-COL membranes at day 10 and 14. The high total protein content and ALP activity at day 17 in cells cultured on BC-COL indicate that this composite allowed the development of the osteoblastic phenotype in vitro. Thus, BC-COL should be considered as alternative biomaterial for bone tissue engineering.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Resistance to corrosion, high tensile strength, low weight, easiness and rapidity of application, are characteristics that have contributed to the spread of the strengthening technique characterized by bonding of carbon fibers reinforced polymer (CFRP). This research aimed to develop an innovate strengthening method for RC beams, based on a high performance cement-based composite of steel fibers (macro + microfibers) to be applied as a transition layer. The purpose of this transition layer is better control the cracking of concrete and detain or even avoid premature debonding of strengthening. A preliminary study in short beams molded with steel fibers and strengthened with CFRP sheet, was carried out where was verified that the conception of the transition layer is valid. Tests were developed to get a cement-based composite with adequate characteristics to constitute the layer transition. Results showed the possibility to develop a high performance material with a pseudo strain-hardening behavior, high strength and fracture toughness. The application of the strengthening on the transition layer surface had significantly to improve the performance levels of the strengthened beam. It summary, it was proven the efficiency of the new strengthening technique, and much information can be used as criteria of projects for repaired and strengthened structures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Reinforced concrete columns might fail because of buckling of the longitudinal reinforcing bar when exposed to earthquake motions. Depending on the hoop stiffness and the length-over-diameter ratio, the instability can be local (in between two subsequent hoops) or global (the buckling length comprises several hoop spacings). To get insight into the topic, an extensive literary research of 19 existing models has been carried out including different approaches and assumptions which yield different results. Finite element fiberanalysis was carried out to study the local buckling behavior with varying length-over-diameter and initial imperfection-over-diameter ratios. The comparison of the analytical results with some experimental results shows good agreement before the post buckling behavior undergoes large deformation. Furthermore, different global buckling analysis cases were run considering the influence of different parameters; for certain hoop stiffnesses and length-over-diameter ratios local buckling was encountered. A parametric study yields an adimensional critical stress in function of a stiffness ratio characterized by the reinforcement configuration. Colonne in cemento armato possono collassare per via dell’instabilità dell’armatura longitudinale se sottoposte all’azione di un sisma. In funzione della rigidezza dei ferri trasversali e del rapporto lunghezza d’inflessione-diametro, l’instabilità può essere locale (fra due staffe adiacenti) o globale (la lunghezza d’instabilità comprende alcune staffe). Per introdurre alla materia, è proposta un’esauriente ricerca bibliografica di 19 modelli esistenti che include approcci e ipotesi differenti che portano a risultati distinti. Tramite un’analisi a fibre e elementi finiti si è studiata l’instabilità locale con vari rapporti lunghezza d’inflessione-diametro e imperfezione iniziale-diametro. Il confronto dei risultati analitici con quelli sperimentali mostra una buona coincidenza fino al raggiungimento di grandi spostamenti. Inoltre, il caso d’instabilità globale è stato simulato valutando l’influenza di vari parametri; per certe configurazioni di rigidezza delle staffe e lunghezza d’inflessione-diametro si hanno ottenuto casi di instabilità locale. Uno studio parametrico ha permesso di ottenere un carico critico adimensionale in funzione del rapporto di rigidezza dato dalle caratteristiche dell’armatura.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L’utilizzo di materiali compositi come i calcestruzzi fibrorinforzati sta diventando sempre più frequente e diffuso. Tuttavia la scelta di nuovi materiali richiede una approfondita analisi delle loro caratteristiche e dei loro comportamenti. I vantaggi forniti dall’aggiunta di fibre d’acciaio ad un materiale fragile, quale il calcestruzzo, sono legati al miglioramento della duttilità e all'aumento di assorbimento di energia. L’aggiunta di fibre permette quindi di migliorare il comportamento strutturale del composito, dando vita ad un nuovo materiale capace di lavorare non solo a compressione ma anche in piccola parte a trazione, ma soprattutto caratterizzato da una discreta duttilità ed una buona capacità plastica. Questa tesi ha avuto come fine l’analisi delle caratteristiche di questi compositi cementizi fibrorinforzati. Partendo da prove sperimentali classiche quali prove di trazione e compressione, si è arrivati alla caratterizzazione di questi materiali avvalendosi di una campagna sperimentale basata sull’applicazione della norma UNI 11039/2003. L’obiettivo principale di questo lavoro consiste nell’analizzare e nel confrontare calcestruzzi rinforzati con fibre di due diverse lunghezze e in diversi dosaggi. Studiando questi calcestruzzi si è cercato di comprendere meglio questi materiali e trovare un riscontro pratico ai comportamenti descritti in teorie ormai diffuse e consolidate. La comparazione dei risultati dei test condotti ha permesso di mettere in luce differenze tra i materiali rinforzati con l’aggiunta di fibre corte rispetto a quelli con fibre lunghe, ma ha anche permesso di mostrare e sottolineare le analogie che caratterizzano questi materiali fibrorinforzati. Sono stati affrontati inoltre gli aspetti legati alle fasi della costituzione di questi materiali sia da un punto di vista teorico sia da un punto di vista pratico. Infine è stato sviluppato un modello analitico basato sulla definizione di specifici diagrammi tensione-deformazione; i risultati di questo modello sono quindi stati confrontati con i dati sperimentali ottenuti in laboratorio.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Zusammenfassung Das Ziel der Arbeit bestand darin, mit der Aufklärung der Abbindereaktion von Zinkphosphatzement eine Grundlage für eine gezielte Modifikation bzw. Optimierung zu schaffen, insbesondere im Hinblick auf einen Einsatz als permanenter Füllungswerkstoff. Über den Abbindechemismus war bislang lediglich bekannt, daß es sich bei den primär gebildeten Reaktionsprodukten um röntgenamorphe Phasen handelt, die sich nach Wochen bzw. Monaten in das thermodynamisch stabile Reaktionsprodukt alpha-Hopeit (alpha-Zn3(PO4)2·4H2O) umwandeln.Im Rahmen der vorliegenden Arbeit gelang durch den Einsatz der Infrarot-Reflexionsspek-troskopie (DRIFT) die Identifikation von Dizink Cyclotetraphosphat-Octahydrat (Zn2P4O12·8H2O) als röntgenamorpher Vorläuferphase. Das kondensierte Phosphat ist hydrolyseempfindlich sowie thermodynamisch instabil. Mit Hilfe der zeitaufgelösten 1H NMR-Spektroskopie konnte gezeigt werden, daß bereits nach ca. 10 Minuten eine Phasenumwandlung (topochemische Disproportionierung) in ein zunächst röntgenamorphes Orthophosphat stattfindet. Mittels 31P Doppelquanten-NMR-Spektroskopie gelang der Nachweis, daß innerhalb des röntgenamorphen Bereiches lokal nahgeordnete (nanokristalline) Bereiche auftreten, deren Ordnung sich auf einer Längenskala von 10 bis 30 Å erstreckt. Die Nanokristallite unterliegen einem Wachstumsprozeß, der schließlich zu alpha-Hopeit-Kristallen mit Ausdehnungen im Mikrometerbereich führt. Die Ursache für die primäre Ausbildung röntgenamorpher Reaktionsprodukte kann zunächst gelösten Aluminophosphatkomplexen zugeordnet werden, die im Verlauf der Abbindereaktion zu anorganischen Polymeren aggregieren und damit als Kristallisationsinhibitoren fungieren.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Das Ziel dieser Arbeit besteht darin, die Möglichkeiten der Sprühtrocknung für die Generierung von Inhalationspulvern zur Therapie von Lungenkrankheiten zu nutzen. Die Erzeugung von physikalisch stabilen und leicht dispergierbaren Partikeln steht hierbei im Vordergrund. Aufgrund von physiko-chemischen Untersuchungen (Glasübergangstemperatur, Fragilität, Relaxationsverhalten, Hygroskopizität) unterschiedlicher amorpher Hilfsstoffe (Lactose, Raffinose, Dextrane, Cyclodextrine) ist für Hydroxypropyl-β-Cyclodextrin das größte Potential für die Stabilisierung eines Wirkstoffes innerhalb einer amorphen Matrix erkennbar. Sprühgetrocknete Partikel weisen im Vergleich zu strahlgemahlenen Partikeln günstigere Dispergier- und Depositionseigenschaften auf. Dies ist vorrangig auf größere Berührungsflächen zwischen strahlgemahlenen Partikeln zurückzuführen. Kugelförmige sprühgetrocknete Partikel besitzen dagegen aufgrund einer punktförmigen Berührung geringere Haftkräfte. Versuche mit unterschiedlich stark gefalteten Partikeloberflächen weisen auf geringere Haftkräfte hin, wenn sich die Partikel an Stellen geringerer Krümmungsradien berühren. Dispergierversuche in einer definierten Rohrströmung (Deagglomerator) lassen auf einen kaskadenartigen Agglomeratzerfall schließen. Durch Sprüheinbettung unterschiedlicher Modellwirkstoffe (Salbutamolsulfat, Ipratropiumbromid, Budesonid) in Hydroxypropyl-β-Cyclodextrin konnten sowohl Einzelformulierungen als auch eine Kombinationsformulierung mit allen drei Wirkstoffen erzeugt werden. Diese weisen bei einem Wirkstoffgehalt bis max. 14% selbst nach vierwöchiger Offenlagerung bei 40°C und 75% r.F. keine bzw. nur geringfügige Veränderungen in der „Fine Particle Dose“ (FPD) auf. Die „Fine Particle Fraction“ (FPF) liegt bei diesen Formulierungen im Bereich von 40% bis 75%. In Verbindung mit einem geeigneten Pack- bzw. Trockenmittel, ist hierbei mit einer physikalischen Stabilität zu rechnen, die eine sinnvolle Produktlaufzeit eines Inhalationspulvers ermöglicht. Formulierungen mit höheren Wirkstoffkonzentrationen zeigen dagegen stärkere Veränderungen nach Stresslagerung. Als Beispiel einer kristallinen Sprühtrocknungsformulierung konnte ein Pulver bestehend aus Mannitol und Budesonid erzeugt werden.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The utilization of borate mineral wastes with glass-ceramic technology was first time studied and primarily not investigated combinations of wastes were incorporated into the research. These wastes consist of; soda lime silica glass, meat bone and meal ash and fly ash. In order to investigate possible and relevant application areas in ceramics, kaolin clay, an essential raw material for ceramic industry was also employed in some studied compositions. As a result, three different glass-ceramic articles obtained by using powder sintering method via individual sintering processes. Light weight micro porous glass-ceramic from borate mining waste, meat bone and meal ash and kaolin clay was developed. In some compositions in related study, soda lime silica glass waste was used as an additive providing lightweight structure with a density below 0.45 g/cm3 and a crushing strength of 1.8±0.1 MPa. In another study within the research, compositions respecting the B2O3–P2O5–SiO2 glass-ceramic ternary system were prepared from; borate wastes, meat bone and meal ash and soda lime silica glass waste and sintered up to 950ºC. Low porous, highly crystallized glass-ceramic structures with density ranging between 1.8 ± 0,7 to 2.0 ± 0,3 g/cm3 and tensile strength ranging between 8,0 ± 2 to 15,0 ± 0,5 MPa were achieved. Lastly, diopside - wollastonite (SiO2-Al2O3-CaO )glass-ceramics from borate wastes, fly ash and soda lime silica glass waste were successfully obtained with controlled rapid sintering between 950 and 1050ºC. The wollastonite and diopside crystal sizes were improved by adopting varied combinations of formulations and heating rates. The properties of the obtained materials show; the articles with a uniform pore structure could be useful for thermal and acoustic insulations and can be embedded in lightweight concrete where low porous glass-ceramics can be employed as building blocks or additive in cement and ceramic industries.