997 resultados para measurement database


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsed electroacoustic (PEA) method is a commonly used non-destructive technique for investigating space charges. It has been developed since early 1980s. These days there is continuing interest for better understanding of the influence of space charge on the reliability of solid electrical insulation under high electric field. The PEA method is widely used for space charge profiling for its robust and relatively inexpensive features. The PEA technique relies on a voltage impulse used to temporarily disturb the space charge equilibrium in a dielectric. The acoustic wave is generated by charge movement in the sample and detected by means of a piezoelectric film. The spatial distribution of the space charge is contained within the detected signal. The principle of such a system is already well established, and several kinds of setups have been constructed for different measurement needs. This thesis presents the design of a PEA measurement system as a systems engineering project. The operating principle and some recent developments are summarised. The steps of electrical and mechanical design of the instrument are discussed. A common procedure for measuring space charges is explained and applied to verify the functionality of the system. The measurement system is provided as an additional basic research tool for the Corporate Research Centre of ABB (China) Ltd. It can be used to characterise flat samples with thickness of 0.2–0.5 mm under DC stress. The spatial resolution of the measurement is 20 μm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intellectual assets have attained continuous attention in the academic field, as they are vital sources of competitive advantage and organizational performance in the contemporary knowledge intensive business environment. Intellectual capital measurement is quite thoroughly addressed in the accounting literature. However, the purpose of the measurement is to support the management of intellectual assets, but the reciprocal relationship between measurement and management has not been comprehensively considered in the literature. The theoretical motivation for this study rose from this paradox, as in order to maximise the effectiveness of knowledge management the two initiatives need to be closely integrated. The research approach of this interventionist case study is constructive. The objective is to develop the case organization’s knowledge management and intellectual capital measurement in a way that they would be closely integrated and the measurement would support the management of intellectual assets. The case analysis provides valuable practical considerations about the integration and related issues as the case company is a knowledge intensive organization in which the know-how of the employees is the central competitive asset and therefore, the management and measurement of knowledge are essential for its future success. The results suggest that the case organization is confronting challenges in managing knowledge. In order to appropriately manage knowledge processes and control the related risks, support from intellectual capital measurement is required. However, challenges in measuring intellectual capital, especially knowledge, could be recognized in the organization. By reflecting the knowledge management situation and the constructed strategy map, a new intellectual measurement system was developed for the case organization. The construction of the system as well as its indicators can be perceived to contribute to the literature, emphasizing of the importance of properly considering the organization’s knowledge situation in developing an intellectual capital measurement system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the process of design and modeling of instrument for knee joint kinematics measurement that can work for both in-vivo and in-vitro subjects. It is designed to be compatible with imaging machine in a sagittal plane. Due to the invasiveness of the imaging machine, the instrument is designed to be able to function independently. The flexibility of this instrument allows to measure anthropometrically different subject. Among the sixth degree of freedom of a knee, three rotational and one translational degree of freedom can be measured for both type of subject. The translational, proximal-distal, motion is stimulated by external force directly applied along its axis. These angular and linear displacements are measured by magnetic sensors and high precision potentiometers respectively

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate genes differentially expressed in ovaries from lean (wild type) and obese (ob/ob) female mice and cyclic AMP production in both groups.METHODS: The expression on messenger RNA levels of 84 genes concerning obesity was analyzed through the PCR array, and cyclic AMP was quantified by the enzyme immunoassay method.RESULTS: The most downregulated genes in the Obesity Group included adenylate cyclase-activating polypeptide type 1, somatostatin, apolipoprotein A4, pancreatic colipase, and interleukin-1 beta. The mean decrease in expression levels of these genes was around 96, 40, 9, 4.2 and 3.6-fold, respectively. On the other hand, the most upregulated genes in the Obesity Group were receptor (calcitonin) activity-modifying protein 3, peroxisome proliferator activated receptor alpha, calcitonin receptor, and corticotropin-releasing hormone receptor 1. The increase means in the expression levels of such genes were 2.3, 2.7, 4.8 and 6.3-fold, respectively. The ovarian cyclic AMP production was significantly higher in ob/ob female mice (2,229±52 fMol) compared to the Control Group (1,814±45 fMol).CONCLUSIONS: Obese and anovulatory female mice have reduced reproductive hormone levels and altered ovogenesis. Several genes have their expression levels altered when leptin is absent, especially adenylate cyclase-activating polypeptide type 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Polycystic ovary syndrome (PCOS) is the most common endocrine metabolic disorder in women between menarche and menopause. Clinical hyperandrogenism is the most important diagnostic criterion of the syndrome, which manifests as hirsutism in 70% of cases. Hirsute carriers of PCOS have high cardiovascular risk. Lipid accumulation product (LAP) is an index for the evaluation of lipid accumulation in adults and the prediction of cardiovascular risk. The aim of this study was to evaluate the association between LAP and hirsutism in women with PCOS. Methods This was a cross-sectional observational study of a secondary database, which included 263 patients who had visited the Hyperandrogenism Outpatient Clinic from November 2009 to July 2014. The exclusion criteria were patients without Ferriman-Gallwey index (FGI) and/or LAP data. We used the Rotterdam criteria for the diagnosis of PCOS. All patients underwent medical assessment followed by measurement and recording of anthropometric data and the laboratory tests for measurement of the following: thyroid-stimulating hormone, follicle-stimulating hormone, prolactin, total testosterone, sex hormone binding globulin, 17-α-hydroxyprogesterone (follicular phase), glycohemoglobin A1c, and basal insulin. In addition, the subjects underwent lipid profiling and oral glucose tolerance tests. Other laboratory measurements were determined according to clinical criteria. LAP and the homeostatic model assessment index (HOMA-IR) were calculated using the data obtained. We divided patients into two groups: the PCOS group with normal LAP (< 34.5) and the PCOS group with altered LAP (> 34.5) to compare the occurrence of hirsutism. For statistical analysis, we used SPSS Statistics for Windows(r) and Microsoft Excel programs, with descriptive (frequencies, percentages, means, and standard deviations) and comparative analyses (Student's t-test and Chi-square test). We considered relations significant when the p-value was≤0.05. Results LAP was high in most patients (n = 177; 67.3%) and the FGI indicated that 58.5% of the patients (n = 154) had hirsutism. The analysis by LAP quartiles showed a positive correlation (p = 0.04) among patients with a high FGI and an upper quartile LAP (> 79.5) when compared with those with LAP < 29.0 (lower quartile). Conclusion This study demonstrated an association between high LAP and hirsutism. The FGI could represent a simple and low-cost tool to infer an increased cardiovascular risk in women with PCOS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to find out the factors that affect customer profitability in the not-for-profit case company. The customer profitability was examined in two different segments of the customer base. The effects that price, cost and the amount of services provided have on the profit margin were studied. The distribution of profitability among the customers and the effect of certain characteristics, such as size of the customer measured in services purchased, on the profitability were analyzed. The theoretical framework was built around customer profitability and the use of customer profitability information in a not-for-profit organization. The present use of customer profitability information and the possibilities of using the results of this research in the case company were presented. Quantitative research methods were used in the empirical part of the study. The results indicate that the two customer segments have differences in their buying behaviors which affect the profitability and thus the measures taken to improve the profitability should be considered with the different characteristics of the customers in mind. Finally the limitations of the study were discussed as possible further research topics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement is a tool for researching. Therefore, it is important that the measuring process is carried out correctly, without distorting the signal or the measured event. Researches of thermoelectric phenomena have been focused more on transverse thermoelectric phenomena during recent decades. Transverse Seebeck effect enables to produce thinner and faster heat flux sensor than before. Studies about transverse Seebeck effect have so far focused on materials, so in this Master’s Thesis instrumentation of transverse Seebeck effect based heat flux sensor is studied, This Master’s Thesis examines an equivalent circuit of transverse Seebeck effect heat flux sensors, their connectivity to electronics and choosing and design a right type amplifier. The research is carried out with a case study which is Gradient Heat Flux Sensors and an electrical motor. In this work, a general equivalent circuit was presented for the transverse Seebeck effect-based heat flux sensor. An amplifier was designed for the sensor of the case study, and the solution was produced for the measurement of the local heat flux of the electric motor to improve the electromagnetic compatibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master’s thesis is devoted to study different heat flux measurement techniques such as differential temperature sensors, semi-infinite surface temperature methods, calorimetric sensors and gradient heat flux sensors. The possibility to use Gradient Heat Flux Sensors (GHFS) to measure heat flux in the combustion chamber of compression ignited reciprocating internal combustion engines was considered in more detail. A. Mityakov conducted an experiment, where Gradient Heat Flux Sensor was placed in four stroke diesel engine Indenor XL4D to measure heat flux in the combustion chamber. The results which were obtained from the experiment were compared with model’s numerical output. This model (a one – dimensional single zone model) was implemented with help of MathCAD and the result of this implementation is graph of heat flux in combustion chamber in relation to the crank angle. The values of heat flux throughout the cycle obtained with aid of heat flux sensor and theoretically were sufficiently similar, but not identical. Such deviation is rather common for this type of experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the problems that slows the development of off-line programming is the low static and dynamic positioning accuracy of robots. Robot calibration improves the positioning accuracy and can also be used as a diagnostic tool in robot production and maintenance. A large number of robot measurement systems are now available commercially. Yet, there is a dearth of systems that are portable, accurate and low cost. In this work a measurement system that can fill this gap in local calibration is presented. The measurement system consists of a single CCD camera mounted on the robot tool flange with a wide angle lens, and uses space resection models to measure the end-effector pose relative to a world coordinate system, considering radial distortions. Scale factors and image center are obtained with innovative techniques, making use of a multiview approach. The target plate consists of a grid of white dots impressed on a black photographic paper, and mounted on the sides of a 90-degree angle plate. Results show that the achieved average accuracy varies from 0.2mm to 0.4mm, at distances from the target from 600mm to 1000mm respectively, with different camera orientations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study concerns performance measurement and management in a collaborative network. Collaboration between companies has been increased in recent years due to the turbulent operating environment. The literature shows that there is a need for more comprehensive research on performance measurement in networks and the use of measurement information in their management. This study examines the development process and uses of a performance measurement system supporting performance management in a collaborative network. There are two main research questions: how to design a performance measurement system for a collaborative network and how to manage performance in a collaborative network. The work can be characterised as a qualitative single case study. The empirical data was collected in a Finnish collaborative network, which consists of a leading company and a reseller network. The work is based on five research articles applying various research methods. The research questions are examined at the network level and at the single network partner level. The study contributes to the earlier literature by producing new and deeper understanding of network-level performance measurement and management. A three-step process model is presented to support the performance measurement system design process. The process model has been tested in another collaborative network. The study also examines the factors affecting the process of designing the measurement system. The results show that a participatory development style, network culture, and outside facilitators have a positive effect on the design process. The study increases understanding of how to manage performance in a collaborative network and what kind of uses of performance information can be identified in a collaborative network. The results show that the performance measurement system is an applicable tool to manage the performance of a network. The results reveal that trust and openness increased during the utilisation of the performance measurement system, and operations became more transparent. The study also presents a management model that evaluates the maturity of performance management in a collaborative network. The model is a practical tool that helps to analyse the current stage of the performance management of a collaborative network and to develop it further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In R&D organizations multiple projects are executed concurrently. Problems arises in managing shared resources since they are needed by multiple projects simultaneously. The objective of this thesis was to study how the project and resource management could be developed in a public sector R&D organization. The qualitative research was carried out in the Magnetic Measurements section at CERN where the section measures magnets for particle accelerators and builds state of the art measurement devices for various needs. Hence, the R&D and measurement projects are very time consuming and very complex. Based on the previous research and the requirements from the organization the best alter- native for resource management was to build a project management information system. A centralized database was constructed and on top of it was built an application for interacting and visualizing the project data. The application allows handling project data, which works as a basis for resource planning before and during the projects are executed. It is one way to standardize the work-flow of projects, which strengthens the project process. Additionally, it was noted that the inner customer’s database, the measurement system and the new application needed to be integrated. Further integration ensures that the project data is received efficiently from customers and available not only within the application but also during the concrete work. The research results introduced a new integrated application, which centralizes the project information flow with better visibility.