995 resultados para Gerontology|Sociology|Quantitative psychology
Resumo:
The aim of our study was to assess the diagnostic usefulness of the gray level parameters to distinguish osteolytic lesions using radiological images. Materials and Methods: A retrospective study was carried out. A total of 76 skeletal radiographs of osteolytic metastases and 67 radiographs of multiple myeloma were used. The cases were classified into nonflat (MM1 and OL1) and flat bones (MM2 and OL2). These radiological images were analyzed by using a computerized method. The parameters calculated were mean, standard deviation, and coefficient of variation (MGL, SDGL, and CVGL) based on gray level histogram analysis of a region-of-interest.Diagnostic utility was quantified bymeasurement of parameters on osteolyticmetastases andmultiplemyeloma, yielding quantification of area under the receiver operating characteristic (ROC) curve (AUC). Results: Flat bone groups (MM2 and OL2) showed significant differences in mean values of MGL ( = 0.048) and SDGL ( = 0.003). Their corresponding values of AUC were 0.758 for MGL and 0.883 for SDGL in flat bones. In nonflat bones these gray level parameters do not show diagnostic ability. Conclusion: The gray level parametersMGL and SDGL show a good discriminatory diagnostic ability to distinguish between multiple myeloma and lytic metastases in flat bones.
Resumo:
Since the classic study of Simon J. Keay published in 1984, knowledge of late Roman amphorae has progressed markedly, thanks to scholars such as Michel Bonifay and Paul Reynolds, amongst others. The area studied by Keay was Catalonia, the ancient Eastern Tarraconensis. The overview here offered for this same region reveals the central role played by African imports in late Antique times, with a minor presence of the Eastern-Mediterranean and South-Hispanic (both Baetican and Lusitanian) productions. Progress in research in the last 25 years has been centred on a series of new and well-dated contexts: the data they have yielded has clarified more precisely the chronology and the proportions of the different imports. On occasion a quantitative approach may even be applied. At the same time the relationship between town and country with respect to the late Roman amphorae is proving of interest and providing results of significance.
Resumo:
The primary objective of this thesis was to research delivery reliability of mill business unit of a forest industry company, especially timely and quantitative accuracy of sales orders. Delivery reliability is an important factor of customer satisfaction, which has a great influence for success of a company. The secondary objective was to find out reasons for possible problems of delivery reliability and give propositions for improvable performances. The empirical part of the thesis based on reporting database of the forest industry company’s ERP-software and detailed information of the mill system. The delivery reliability results of the mill business unit were compared to delivery reliability of similar mill business unit inside the forest industry company. The research results expressed problems in the supply chain. The delivery reliability reporting should be also developed further. This would advance delivery reliability monitoring. The improvement propositions of the thesis were logistic operation mode estimation, particular benchmarking of the compared mill business unit and more detailed survey on production delivery reliability.
Resumo:
This work describes a validation of an analytical procedure for the analysis of petroleum hydrocarbons in marine sediment samples. The proposed protocol is able to measure n-alkanes and polycyclic aromatic hydrocarbons (PAH) in samples at concentrations as low as 30 ng/g, with a precision better than 15% for most of analytes. The extraction efficiency of fortified sediments varied from 65.1 to 105.6% and 59.7 to 97.8%, for n-alkanes and PAH in the ranges: C16 - C32 and fluoranthene - benzo(a)pyrene, respectively. The analytical protocol was applied to determine petroleum hydrocarbons in sediments collected from a marine coastal zone.
Resumo:
An alternative methodology for analysis of acetaminophen (Ace), phenylephrine (Phe) and carbinoxamine (Car) in tablets by ion-pair reversed phase high performance liquid chromatography was validated. The pharmaceutical preparations were analyzed by using a C18 column (5 μm, 300 mm, 3.9 mm) and mobile phase consisting of 60% methanol and 40% potassium monobasic phosphate aqueous solution (62.46 mmol L-1) added with 1 mL phosphoric acid, 0.50 mL triethylamine and 0.25 g sodium lauryl sulfate. Isocratic analysis was performed under direct UV detection at 220 nm for Phe and Car and at 300 nm for Ace within 5 min.
Resumo:
A photometric procedure was developed for determination of aflatoxin B1 in peanuts by TLC-CCD technique. The quantification and detection limit were 1.2 μg kg-1 and 0.4 ng per spot, respectively, with mean recovery of 98%. The CCD camera is sufficiently sensitive to detect small changes in spots fluorescence intensity and the results for performance confirmed the efficiency of the method. Another important property of CCD detector is its linearity for a wide range of luminous stimulus determined by analysis of five-point calibration curves using the intensity of AFB1 fluorescence versus AFB1 concentration (0.8 to 4.8 ng per spot). The method was applied to the analysis of thirty nine peanut samples and aflatoxin B1 levels ranged from 16 to 115 μg kg-1. The TLC-CCD and the photometric procedure developed in this study demonstrated to be a simple and efficient tool for quantitative analyses of AFB1 in peanut samples.
Resumo:
A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.
Resumo:
A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.
Resumo:
Genetic algorithm and multiple linear regression (GA-MLR), partial least square (GA-PLS), kernel PLS (GA-KPLS) and Levenberg-Marquardt artificial neural network (L-M ANN) techniques were used to investigate the correlation between retention index (RI) and descriptors for 116 diverse compounds in essential oils of six Stachys species. The correlation coefficient LGO-CV (Q²) between experimental and predicted RI for test set by GA-MLR, GA-PLS, GA-KPLS and L-M ANN was 0.886, 0.912, 0.937 and 0.964, respectively. This is the first research on the QSRR of the essential oil compounds against the RI using the GA-KPLS and L-M ANN.
Resumo:
This study describes the validation of UV spectrophotometric method for quantitative determination of gemifloxacin mesylate (GFM) in tablets using methanol as solvent. The method was specific, linear, precise, exact and robust at 272 and 343 nm. The results confirmed that the method in both wavelengths is valid and useful to the routine quality control of GFM in coated tablets. The validate method was compared to liquid chromatography (HPLC), microbiological assay and visible (VIS) spectrophotometry, which were previously developed and validated to the same drug. There was not significative difference between the methods for GFM quantitation.
Resumo:
The hydroalcoholic extracts prepared from standard leaves of Maytenus ilicifolia and commercial samples of espinheira-santa were evaluated qualitatively (fingerprinting) and quantitatively. In this paper, fingerprinting chromatogram coupled with Principal Component Analysis (PCA) is described for the metabolomic analysis of standard and commercial espinheira-santa samples. The epicatechin standard was used as an external standard for the development and validation of a quantitative method for the analysis in herbal medicines using a photo diode array detector. This method has been applied for quantification of epicatechin in commercialized herbal medicines sold as espinheira-santa in Brazil and in the standard sample of M. ilicifolia.
Resumo:
Prior to obtain a standardized dried extract from V. ferruginea, lupeol was first time isolated from leaves and used as chemical maker. An analytical method using HPLC-PDA for lupeol determination in V. ferruginea intermediate products was developed using a C8 reverse-phase column, acetonitrile-acetic acid (99.99:0.01, v/v) as mobile phase at 0.8 mL min-1, oven temperature at 23-25 ºC, sample injection volume at 30 µL and detection at 210 nm. The method presented linearity from 10 to 160 µg mL-1, accuracy, precision, robustness and suitable sensitivity proving to be a useful tool to the obtainment process of lupeol standardized dried extracts of V. ferruginea.
Resumo:
This work quantifies two important epidemiological features of the bean (Phaseolus vulgaris)/Phaeoisariopsis griseola pathosystem. The first is the effect of the number of nights of leaf wetness on infection efficiency. Infection efficiency was below 10% when inoculated leaflets were exposed to less than two nights of leaf wetness. Optimum infection efficiencies were obtained after three to four nights of leaf wetness, at about 50%. Further nights of leaf wetness did not increase the infection efficiency. The second feature quantified is the relative rate of leaflet defoliation for varying levels of angular leaf spot severity. It increased with disease severity according to a logarithm-like curve, and a relative rate of 0.23 day-1 was estimated for a severity of 18%. The implications of these results on the disease epidemiology are discussed.
Resumo:
Flow injection (FI) methodology, using diffuse reflectance in the visible region of the spectrum, for the analysis of total sulfur in the form of sulfate, precipitated in the form of barium sulfate, is presented. The method was applied to biodiesel, to plant leaves and to natural waters analysis. The analytical signal (S) correlates linearly with sulfate concentration (C) between 20 and 120 ppm, through the equation S=-1.138+0.0934 C (r = 0.9993). The experimentally observed limit of detection is about 10 ppm. The mean R.S.D. is about 3.0 %. Real samples containing sulfate were analyzed and the results obtained by the FI and by the reference batch turbidimetric method using the statistical Student's t-test and F-test were compared.
Resumo:
A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.