989 resultados para 1995_12180638 Optics-20
Resumo:
Bulk handling of powders and granular solids is common in many industries and often gives rise to handling difficulties especially when the material exhibits complex cohesive behaviour. For example, high storage stresses in a silo can lead to high cohesive strength of the stored solid, which may in turn cause blockages such as ratholing or arching near the outlet during discharge. This paper presents a Discrete Element Method study of discharge of a granular solid with varying levels of cohesion from a flat-bottomed silo. The DEM simulations were conducted using the commercial EDEM code with a recently developed DEM contact model for cohesive solids implemented through an API. The contact model is based on an elasto-plastic contact with adhesion and uses hysteretic non-linear loading and unloading paths to model the elastic-plastic contact deformation. The adhesion parameter is a function of the maximum contact overlap. The model has been shown to be able to predict the stress history dependent behaviour depicted by a flow function of the material. The effects of cohesion on the discharge rate and flow pattern in the silo are investigated. The predicted discharge rates are compared for the varying levels of cohesion and the effect of adhesion is evaluated. The ability of the contact model to qualitatively predict the phenomena that are present in the discharge of a silo has been shown with the salient feature of mixed flow from a flat bottomed hopper identified in the simulation.
Resumo:
Many researchers have investigated the flow and segregation behaviour in model scale experimental silos at normal gravity conditions. However it is known that the stresses experienced by the bulk solid in industrial silos are high when compared to model silos. Therefore it is important to understand the effect of stress level on flow and segregation behaviour and establish the scaling laws governing this behaviour. The objective of this paper is to understand the effect of gravity on the flow and segregation behaviour of bulk solids in a silo centrifuge model. The materials used were two mixtures composed of Polyamide and glass beads. The discharge of two bi-disperse bulk solids in a silo centrifuge model were recorded under accelerations ranging from 1g to 15g. The velocity distribution during discharge was evaluated using Particle Image Velocimetry (PIV) techniques and the concentration distribution of large and small particles were obtained by imaging processing techniques. The flow and segregation behaviour at high gravities were then quantified and compared with the empirical equations available in the literature.
Resumo:
This paper presents an analytical solution for the solid stresses in a silo with an internal tube. The research was conducted to support the design of a group of full scale silos with large inner concrete tubes. The silos were blasted and formed out of solid rock underground for storing iron ore pellets. Each of these silos is 40m in diameter and has a 10m diameter concrete tube with five levels of openings constructed at the centre of each rock silo. A large scale model was constructed to investigate the stress regime for the stored pellets and to evaluate the solids flow pattern and the loading on the concrete tube. This paper focuses on the development of an analytical solution for stresses in the iron ore pellets in the silo and the effect of the central tube on the stress regimes. The solution is verified using finite element analysis before being applied to analyse stresses in the solid in the full scale silo and the effect of the size of the tube.
Resumo:
In this study, the behaviour of iron ore fines with varying levels of adhesion was investigated using a confined compression test and a uniaxial test. The uniaxial test was conducted using the semi-automated uniaxial EPT tester in which the cohesive strength of a bulk solid is evaluated from an unconfined compression test following a period of consolidation to a pre-defined vertical stress. The iron ore fines were also tested by measuring both the vertical and circumferential strains on the cylindrical container walls under vertical loading in a separate confined compression tester - the K0 tester, to determine the lateral pressure ratio. Discrete Element Method simulations of both experiments were carried out and the predictions were compared with the experimental observations. A recently developed DEM contact model for cohesive solids, an Elasto-Plastic Adhesive model, was used. This particle contact model uses hysteretic non-linear loading and unloading paths and an adhesion parameter which is a function of the maximum contact overlap. The model parameters for the simulations are phenomenologically based to reproduce the key bulk characteristics exhibited by the solid. The simulation results show a good agreement in capturing the stress history dependent behaviour depicted by the flow function of the cohesive iron ore fines while also providing a reasonably good match for the lateral pressure ratio observed during the confined compression K0 tests. This demonstrates the potential for the DEM model to be used in the simulation of bulk handling applications.
Resumo:
Introduction: It has been suggested that doctors in their first year of post-graduate training make a disproportionate number of prescribing errors.
Obkective: This study aimed to compare the prevalence of prescribing errors made by first-year post-graduate doctors with that of errors by senior doctors and non-medical prescribers and to investigate the predictors of potentially serious prescribing errors.
Methods: Pharmacists in 20 hospitals over 7 prospectively selected days collected data on the number of medication orders checked, the grade of prescriber and details of any prescribing errors. Logistic regression models (adjusted for clustering by hospital) identified factors predicting the likelihood of prescribing erroneously and the severity of prescribing errors.
Results: Pharmacists reviewed 26,019 patients and 124,260 medication orders; 11,235 prescribing errors were detected in 10,986 orders. The mean error rate was 8.8 % (95 % confidence interval [CI] 8.6-9.1) errors per 100 medication orders. Rates of errors for all doctors in training were significantly higher than rates for medical consultants. Doctors who were 1 year (odds ratio [OR] 2.13; 95 % CI 1.80-2.52) or 2 years in training (OR 2.23; 95 % CI 1.89-2.65) were more than twice as likely to prescribe erroneously. Prescribing errors were 70 % (OR 1.70; 95 % CI 1.61-1.80) more likely to occur at the time of hospital admission than when medication orders were issued during the hospital stay. No significant differences in severity of error were observed between grades of prescriber. Potentially serious errors were more likely to be associated with prescriptions for parenteral administration, especially for cardiovascular or endocrine disorders.
Conclusions: The problem of prescribing errors in hospitals is substantial and not solely a problem of the most junior medical prescribers, particularly for those errors most likely to cause significant patient harm. Interventions are needed to target these high-risk errors by all grades of staff and hence improve patient safety.
Resumo:
Superlenses enable near-field imaging beyond the diffraction limit. However, their widespread implementation in optical imaging technology so far has been limited by large-scale fabrication, fixed lens position and specific object materials. Here, we demonstrate that a dielectric lamella of sub-wavelength size in all three spatial dimensions behaves as a compact superlens that operates at infrared wavelengths and can be positioned to image any local microscopic area of interest on the sample. In particular, the lamella superlens may be placed in contact with any type of object and therefore enables examination of hard-to-scan samples e.g. with high topography or in liquids, without altering the specimen design. This lamella-based local superlens design is directly applicable to sub-wavelength light-based technology such as integrated optics.
Resumo:
Dissertação, Mestrado, Contabilidade e Finanças, Instituto Politécnico de Santarém, Escola Superior de Gestão e Tecnologia, 2014
Resumo:
O objectivo desta tese é a utilização de materiais híbridos orgânicos-inorgânicos, designados por di-ureiasis modificados pela adição de tetra-propóxido de zircónio (Zr(i-OPr)4) estabilizado com ácido metacrílico (CH2=C(CH3)COOH), obtidos pela via sol-gel, para aplicações em dispositivos ópticos integrados de baixo custo. A estrutura local dos di-ureiasis com diferentes concentrações de propóxido de zircónio (20 a 80 % mol) foi estudada por difracção de raios-X, espalhamento de raios X a baixos ângulos, microscopia de força atómica, ressonância magnética nuclear dos núcleos dos átomos de 29Si e 13C, espectroscopia no infravermelho por transformada de Fourier, espectroscopia de Raman por transformada de Fourier e termogravimetria. A influência dos parâmetros de síntese, concentração de tetra propóxido de zircónio e rácio tetra propóxido de zircónio: ácido metacrilico na estrutura e propriedades das amostras em monólito e filmes finos (depositados pela técnica de deposição por rotação do substrato) foram avaliadas, permitindo obter amostras transparentes, fotopolimerizáveis e estáveis termicamente até aos 100 ºC. Foram determinadas as propriedades dos guias planares em substratos de vidro borosilicato e silício oxidado (1
Resumo:
Dissertação de mest., Tecnologia de Alimentos, Instituto Superior de Engenharia, Univ. do Algarve, 2012
Resumo:
Dissertação de mestrado, Finanças Empresariais, Faculdade de Economia, Universidade do Algarve, 2014
Resumo:
Noch bis vor wenigen Jahren galt die interne Kommunikation in den meisten Unternehmen im Vergleich zur Kommunikation mit externen Zielgruppen als deutlich weniger anspruchsvoll oder gar als in irgendeiner Weise wettbewerbsrelevant. Wurde sie lange als reine Sozialleistung betrachtet, rückt sie nun - insbesondere vor dem Hintergrund voranschreitender Globalisierung und ihren Auswirkungen auf die Wettbewerbsfähigkeit der Unternehmen - langsam als strategisches Führungsinstrument in das Bewusstsein vieler Unternehmenslenker. Denn mehr und mehr wird deutlich, dass die eigenen Mitarbeiter ausschlaggebender Faktor bei der Bewältigung von Veränderungen sind.