899 resultados para validation study


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The German version of the Conners Adult ADHD Rating Scales (CAARS) has proven to show very high model fit in confirmative factor analyses with the established factors inattention/memory problems, hyperactivity/restlessness, impulsivity/emotional lability, and problems with self-concept in both large healthy control and ADHD patient samples. This study now presents data on the psychometric properties of the German CAARS-self-report (CAARS-S) and observer-report (CAARS-O) questionnaires.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

What's known on the subject? and What does the study add? One area of particular growth for robotic surgery has been partial nephrectomy. Despite a perceived notion that robotic-assisted partial nephrectomy is more easily adaptable compared to laparoscopic partial nephrectomy, there is nonetheless an associated learning curve. Validated training models with a corresponding assessment method for robotic-assisted partial nephrectomy were previously unavailable. We have designed and validated a RAPN surgical model appropriate for resident and fellow training.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In chronic haemodialysis patients, anaemia is a frequent finding associated with high therapeutic costs and further expenses resulting from serial laboratory measurements. HemoHue HH1, HemoHue Ltd, is a novel tool consisting of a visual scale for the noninvasive assessment of anaemia by matching the coloration of the conjunctiva with a calibrated hue scale. The aim of the study was to investigate the usefulness of HemoHue in estimating individual haemoglobin concentrations and binary treatment outcomes in haemodialysis patients. A prospective blinded study with 80 hemodialysis patients comparing the visual haemoglobin assessment with the standard laboratory measurement was performed. Each patient's haemoglobin concentration was estimated by seven different medical and nonmedical observers with variable degrees of clinical experience on two different occasions. The estimated population mean was close to the measured one (11.06 ± 1.67 versus 11.32 ± 1.23 g/dL, P < 0.0005). A learning effect could be detected. Relative errors in individual estimates reached, however, up to 50%. Insufficient performance in predicting binary outcomes (ROC AUC: 0.72 to 0.78) and poor interrater reliability (Kappa < 0.6) further characterised this method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Myocardial blood flow (MBF) is the gold standard to assess myocardial blood supply and, as recently shown, can be obtained by myocardial contrast echocardiography (MCE). The aims of this human study are (i) to test whether measurements of collateral-derived MBF by MCE are feasible during elective angioplasty and (ii) to validate the concept of pressure-derived collateral-flow assessment. METHODS AND RESULTS: Thirty patients with stable coronary artery disease underwent MCE of the collateral-receiving territory during and after angioplasty of 37 stenoses. MCE perfusion analysis was successful in 32 cases. MBF during and after angioplasty varied between 0.060-0.876 mL min(-1) g(-1) (0.304+/-0.196 mL min(-1) g(-1)) and 0.676-1.773 mL min(-1) g(-1) (1.207+/-0.327 mL min(-1) g(-1)), respectively. Collateral-perfusion index (CPI) is defined as the rate of MBF during and after angioplasty varied between 0.05 and 0.67 (0.26+/-0.15). During angioplasty, simultaneous measurements of mean aortic pressure, coronary wedge pressure, and central venous pressure determined the pressure-derived collateral-flow index (CFI(p)), which varied between 0.04 and 0.61 (0.23+/-0.14). Linear-regression analysis demonstrated an excellent agreement between CFI(p) and CPI (y=0.88 x +0.01; r(2)=0.92; P<0.0001). CONCLUSION: Collateral-derived MBF measurements by MCE during angioplasty are feasible and proved that the pressure-derived CFI exactly reflects collateral relative to normal myocardial perfusion in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To validate the Probability of Repeated Admission (Pra) questionnaire, a widely used self-administered tool for predicting future healthcare use in older persons, in three European healthcare systems. DESIGN: Prospective study with 1-year follow-up. SETTING: Hamburg, Germany; London, United Kingdom; Canton of Solothurn, Switzerland. PARTICIPANTS: Nine thousand seven hundred thirteen independently living community-dwelling people aged 65 and older. MEASUREMENTS: Self-administered eight-item Pra questionnaire at baseline. Self-reported number of hospital admissions and physician visits during 1 year of follow-up. RESULTS: In the combined sample, areas under the receiver operating characteristic curves (AUCs) were 0.64 (95% confidence interval (CI)=0.62-0.66) for the prediction of one or more hospital admissions and 0.68 (95% CI=0.66-0.69) for the prediction of more than six physician visits during the following year. AUCs were similar between sites. In comparison, prediction models based on a person's age and sex alone exhibited poor predictive validity (AUC or= 0.5) were 2.3 times as likely (95% CI=2.1-2.6) as low-risk individuals to have a hospital admission, and 2.1 times as likely (95% CI=2.0-2.2) to have more than six physician visits. CONCLUSION: The Pra instrument exhibits good validity for predicting future health service use on a population level in different healthcare settings. Administrative data have shown similar predictive validity, but in practice, such data are often not available. The Pra is likely of high interest to governments and health insurance companies worldwide as a basis for programs aimed at health risk management in older persons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article reports about the internet based, second multicenter study (MCS II) of the spine study group (AG WS) of the German trauma association (DGU). It represents a continuation of the first study conducted between the years 1994 and 1996 (MCS I). For the purpose of one common, centralised data capture methodology, a newly developed internet-based data collection system ( http://www.memdoc.org ) of the Institute for Evaluative Research in Orthopaedic Surgery of the University of Bern was used. The aim of this first publication on the MCS II was to describe in detail the new method of data collection and the structure of the developed data base system, via internet. The goal of the study was the assessment of the current state of treatment for fresh traumatic injuries of the thoracolumbar spine in the German speaking part of Europe. For that reason, we intended to collect large number of cases and representative, valid information about the radiographic, clinical and subjective treatment outcomes. Thanks to the new study design of MCS II, not only the common surgical treatment concepts, but also the new and constantly broadening spectrum of spine surgery, i.e. vertebro-/kyphoplasty, computer assisted surgery and navigation, minimal-invasive, and endoscopic techniques, documented and evaluated. We present a first statistical overview and preliminary analysis of 18 centers from Germany and Austria that participated in MCS II. A real time data capture at source was made possible by the constant availability of the data collection system via internet access. Following the principle of an application service provider, software, questionnaires and validation routines are located on a central server, which is accessed from the periphery (hospitals) by means of standard Internet browsers. By that, costly and time consuming software installation and maintenance of local data repositories are avoided and, more importantly, cumbersome migration of data into one integrated database becomes obsolete. Finally, this set-up also replaces traditional systems wherein paper questionnaires were mailed to the central study office and entered by hand whereby incomplete or incorrect forms always represent a resource consuming problem and source of error. With the new study concept and the expanded inclusion criteria of MCS II 1, 251 case histories with admission and surgical data were collected. This remarkable number of interventions documented during 24 months represents an increase of 183% compared to the previously conducted MCS I. The concept and technical feasibility of the MEMdoc data collection system was proven, as the participants of the MCS II succeeded in collecting data ever published on the largest series of patients with spinal injuries treated within a 2 year period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives of this study were to develop and validate a tool for assessing pain in population-based observational studies and to develop three subscales for back/neck, upper extremity and lower extremity pain. Based on a literature review, items were extracted from validated questionnaires and reviewed by an expert panel. The initial questionnaire consisted of a pain manikin and 34 items relating to (i) intensity of pain in different body regions (7 items), (ii) pain during activities of daily living (18 items) and (iii) various pain modalities (9 items). Psychometric validation of the initial questionnaire was performed in a random sample of the German-speaking Swiss population. Analyses included tests for reliability, correlation analysis, principal components factor analysis, tests for internal consistency and validity. Overall, 16,634 of 23,763 eligible individuals participated (70%). Test-retest reliability coefficients ranged from 0.32 to 0.97, but only three coefficients were below 0.60. Subscales were constructed combining four items for each of the subscales. Item-total coefficients ranged from 0.76 to 0.86 and Cronbach's alpha were 0.75 or higher for all subscales. Correlation coefficients between subscales and three validated instruments (WOMAC, SPADI and Oswestry) ranged from 0.62 to 0.79. The final Pain Standard Evaluation Questionnaire (SEQ Pain) included 28 items and the pain manikin and accounted for the multidimensionality of pain by assessing pain location and intensity, pain during activity, triggers and time of onset of pain and frequency of pain medication. It was found to be reliable and valid for the assessment of pain in population-based observational studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: The aim of this study was to determine which of two clinically applied methods, electromyography or acceleromyography, was less affected by external disturbances, had a higher sensitivity and which would provide the better input signal for closed loop control of muscle relaxation. METHODS: In 14 adult patients, anaesthesia was induced with intravenous opioids and propofol. The response of the thumb to ulnar nerve stimulation was recorded on the same arm. Mivacurium was used for neuromuscular blockade. Under stable conditions of relaxation, the infusion-rate was decreased and the effects of turning the hand were investigated. RESULTS: Electromyography and acceleromyography both reflected the change of the infusion rate (P = 0.015 and P < 0.001, respectively). Electromyography was significantly less affected by the hand-turn (P = 0.008) than acceleromyography. While zero counts were detected with acceleromyography, electromyography could still detect at least one count in 51.1%. CONCLUSIONS: Electromyography is more reliable for use in daily practice as it is less influenced by external disturbances than acceleromyography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical efficacy of aerosol therapy in premature newborns depends on the efficiency of delivery of aerosolized drug to the bronchial tree. To study the influence of various anatomical, physical, and physiological factors on aerosol delivery in preterm newborns, it is crucial to have appropriate in vitro models, which are currently not available. We therefore constructed the premature infant nose throat-model (PrINT-Model), an upper airway model corresponding to a premature infant of 32-wk gestational age by three-dimensional (3D) reconstruction of a three-planar magnetic resonance imaging scan and subsequent 3D-printing. Validation was realized by visual comparison and comparison of total airway volume. To study the feasibility of measuring aerosol deposition, budesonide was aerosolized through the cast and lung dose was expressed as percentage of nominal dose. The airway volumes of the initial magnetic resonance imaging and validation computed tomography scan showed a relative deviation of 0.94%. Lung dose at low flow (1 L/min) was 61.84% and 9.00% at high flow (10 L/min), p < 0.0001. 3D-reconstruction provided an anatomically accurate surrogate of the upper airways of a 32-wk-old premature infant, making the model suitable for future in vitro testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory. METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length. RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes. CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: With more children receiving cochlear implants during infancy, there is a need for validated assessments of pre-verbal and early verbal auditory skills. The LittlEARS Auditory Questionnaire is presented here as the first module of the LittlEARS test battery. The LittlEARS Auditory Questionnaire was developed and piloted to assess the auditory behaviour of normal hearing children and hearing impaired children who receive a cochlear implant or hearing aid prior to 24 months of age. This paper presents results from two studies: one validating the LittlEARS Auditory Questionnaire on children with normal hearing who are German speaking and a second validating the norm curves found after adaptation and administration of the questionnaire to children with normal hearing in 15 different languages. METHODS: Scores from a group of 218 German and Austrian children with normal hearing between 5 days and 24 months of age were used to create a norm curve. The questionnaire was adapted from the German original into English and then 15 other languages to date. Regression curves were found based on parental responses from 3309 normal hearing infants and toddlers. Curves for each language were compared to the original German validation curve. RESULTS: The results of the first study were a norm curve which reflects the age-dependence of auditory behaviour, reliability and homogeneity as a measure of auditory behaviour, and calculations of expected and critical values as a function of age. Results of the second study show that the regression curves found for all the adapted languages are essentially equal to the German norm curve, as no statistically significant differences were found. CONCLUSIONS: The LittlEARS Auditory Questionnaire is a valid, language-independent tool for assessing the early auditory behaviour of infants and toddlers with normal hearing. The results of this study suggest that the LittlEARS Auditory Questionnaire could also be very useful for documenting children's progress with their current amplification, providing evidence of the need for implantation, or highlighting the need for follow-up in other developmental areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The estimation of physiologic ability and surgical stress (E-PASS) has been used to produce a numerical estimate of expected mortality and morbidity after elective gastrointestinal surgery. The aim of this study was to validate E-PASS in a selected cohort of patients requiring liver resections (LR). METHODS: In this retrospective study, E-PASS predictor equations for morbidity and mortality were applied to the prospective data from 243 patients requiring LR. The observed rates were compared with predicted rates using Fisher's exact test. The discriminative capability of E-PASS was evaluated using receiver-operating characteristic (ROC) curve analysis. RESULTS: The observed and predicted overall mortality rates were both 3.3% and the morbidity rates were 31.3 and 26.9%, respectively. There was a significant difference in the comprehensive risk scores for deceased and surviving patients (p = 0.043). However, the scores for patients with or without complications were not significantly different (p = 0.120). Subsequent ROC curve analysis revealed a poor predictive accuracy for morbidity. CONCLUSIONS: The E-PASS score seems to effectively predict mortality in this specific group of patients but is a poor predictor of complications. A new modified logistic regression might be required for LR in order to better predict the postoperative outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Enzootic pneumonia (EP) of pigs, caused by Mycoplasma hyopneumoniae has been a notifiable disease in Switzerland since May 2003. The diagnosis of EP has been based on multiple methods, including clinical, bacteriological and epidemiological findings as well as pathological examination of lungs (mosaic diagnosis). With the recent development of a real-time PCR (rtPCR) assay with 2 target sequences a new detection method for M. hyopneumoniae became available. This assay was tested for its applicability to nasal swab material from live animals. Pigs from 74 herds (average 10 pigs per herd) were tested. Using the mosaic diagnosis, 22 herds were classified as EP positive and 52 as EP negative. From the 730 collected swab samples we were able to demonstrate that the rtPCR test was 100% specific. In cases of cough the sensitivity on herd level of the rtPCR is 100%. On single animal level and in herds without cough the sensitivity was lower. In such cases, only a positive result would be proof for an infection with M. hyopneumoniae. Our study shows that the rtPCR on nasal swabs from live pigs allows a fast and accurate diagnosis in cases of suspected EP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Recommendations from international task forces on geriatric assessment emphasize the need for research including validation of cancer-specific geriatric assessment (C-SGA) tools in oncological settings. The objective of this study was to evaluate the feasibility of the SAKK Cancer-Specific Geriatric Assessment (C-SGA) in clinical practice. METHODS A cross sectional study of cancer patients >=65 years old (N = 51) with pathologically confirmed cancer presenting for initiation of chemotherapy treatment (07/01/2009-03/31/2011) at two oncology departments in Swiss canton hospitals: Kantonsspital Graubunden (KSGR N = 25), Kantonsspital St. Gallen (KSSG N = 26). Data was collected using three instruments, the SAKK C-SGA plus physician and patient evaluation forms. The SAKK C-SGA includes six measures covering five geriatric assessment domains (comorbidity, function, psychosocial, nutrition, cognition) using a mix of medical record abstraction (MRA) and patient interview. Five individual domains and one overall SAKK C-SGA score were calculated and dichotomized as below/above literature-based cut-offs. The SAKK C-SGA was evaluated by: patient and physician estimated time to complete, ease of completing, and difficult or unanswered questions. RESULTS Time to complete the patient questionnaire was considered acceptable by almost all (>=96%) patients and physicians. Patients reported slightly shorter times to complete the questionnaire than physicians (17.33 +/- 7.34 vs. 20.59 +/- 6.53 minutes, p = 0.02). Both groups rated the patient questionnaire as easy/fairly easy to complete (91% vs. 84% respectively, p = 0.14) with few difficult or unanswered questions. The MRA took on average 8.32 +/- 4.72 minutes to complete. Physicians (100%) considered time to complete MRA acceptable, 96% rated it as easy/fairly easy to complete. Individual study site populations differed on health-related characteristics (excellent/good physician-rated general health KSGR 71% vs. KSSG 32%, p = 0.007). The overall mean C-SGA score was 2.4 +/- 1.12. Patients at KSGR had lower C-SGA scores (2.00 +/- 1.19 vs. 2.81 +/- 0.90, p = 0.009) and a smaller proportion (28% vs.65%, p = 0.008) was above the C-SGA cut-off score compared to KSSG. CONCLUSIONS These results suggest the SAKK C-SGA is a feasible practical tool for use in clinical practice. It demonstrated discriminative ability based on objective geriatric assessment measures, but additional investigations on use for clinical decision-making are warranted. The SAKK C-SGA also provides important usable domain information for intervention to optimize outcomes in older cancer patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Delivering cochlear implants through a minimally invasive tunnel (1.8 mm in diameter) from the mastoid surface to the inner ear is referred to as direct cochlear access (DCA). Based on cone beam as well as micro-computed tomography imaging, this in vitro study evaluates the feasibility and efficacy of manual cochlear electrode array insertions via DCA. Free-fitting electrode arrays were inserted in 8 temporal bone specimens with previously drilled DCA tunnels. The insertion depth angle, procedural time, tunnel alignment as well as the inserted scala and intracochlear trauma were assessed. Seven of the 8 insertions were full insertions, with insertion depth angles higher than 520°. Three cases of atraumatic scala tympani insertion, 3 cases of probable basilar membrane rupture and 1 case of dislocation into the scala vestibuli were observed (1 specimen was damaged during extraction). Manual electrode array insertion following a DCA procedure seems to be feasible and safe and is a further step toward clinical application of image-guided otological microsurgery.