699 resultados para Elicottero raffreddamento ejector exhaust
Resumo:
Estimating un-measurable states is an important component for onboard diagnostics (OBD) and control strategy development in diesel exhaust aftertreatment systems. This research focuses on the development of an Extended Kalman Filter (EKF) based state estimator for two of the main components in a diesel engine aftertreatment system: the Diesel Oxidation Catalyst (DOC) and the Selective Catalytic Reduction (SCR) catalyst. One of the key areas of interest is the performance of these estimators when the catalyzed particulate filter (CPF) is being actively regenerated. In this study, model reduction techniques were developed and used to develop reduced order models from the 1D models used to simulate the DOC and SCR. As a result of order reduction, the number of states in the estimator is reduced from 12 to 1 per element for the DOC and 12 to 2 per element for the SCR. The reduced order models were simulated on the experimental data and compared to the high fidelity model and the experimental data. The results show that the effect of eliminating the heat transfer and mass transfer coefficients are not significant on the performance of the reduced order models. This is shown by an insignificant change in the kinetic parameters between the reduced order and 1D model for simulating the experimental data. An EKF based estimator to estimate the internal states of the DOC and SCR was developed. The DOC and SCR estimators were simulated on the experimental data to show that the estimator provides improved estimation of states compared to a reduced order model. The results showed that using the temperature measurement at the DOC outlet improved the estimates of the CO , NO , NO2 and HC concentrations from the DOC. The SCR estimator was used to evaluate the effect of NH3 and NOX sensors on state estimation quality. Three sensor combinations of NOX sensor only, NH3 sensor only and both NOX and NH3 sensors were evaluated. The NOX only configuration had the worst performance, the NH3 sensor only configuration was in the middle and both the NOX and NH3 sensor combination provided the best performance.
Resumo:
The Homogeneous Charge Compression Ignition (HCCI) engine is a promising combustion concept for reducing NOx and particulate matter (PM) emissions and providing a high thermal efficiency in internal combustion engines. This concept though has limitations in the areas of combustion control and achieving stable combustion at high loads. For HCCI to be a viable option for on-road vehicles, further understanding of its combustion phenomenon and its control are essential. Thus, this thesis has a focus on both the experimental setup of an HCCI engine at Michigan Technological University (MTU) and also developing a physical numerical simulation model called the Sequential Model for Residual Affected HCCI (SMRH) to investigate performance of HCCI engines. The primary focus is on understanding the effects of intake and exhaust valve timings on HCCI combustion. For the experimental studies, this thesis provided the contributions for development of HCCI setup at MTU. In particular, this thesis made contributions in the areas of measurement of valve profiles, measurement of piston to valve contact clearance for procuring new pistons for further studies of high geometric compression ratio HCCI engines. It also consists of developing and testing a supercharging station and the setup of an electrical air heater to extend the HCCI operating region. The HCCI engine setup is based on a GM 2.0 L LHU Gen 1 engine which is a direct injected engine with variable valve timing (VVT) capabilities. For the simulation studies, a computationally efficient modeling platform has been developed and validated against experimental data from a single cylinder HCCI engine. In-cylinder pressure trace, combustion phasing (CA10, CA50, BD) and performance metrics IMEP, thermal efficiency, and CO emission are found to be in good agreement with experimental data for different operating conditions. Effects of phasing intake and exhaust valves are analyzed using SMRH. In addition, a novel index called Fuel Efficiency and Emissions (FEE) index is defined and is used to determine the optimal valve timings for engine operation through the use of FEE contour maps.
Resumo:
Accounting for around 40% of the total final energy consumption, the building stock is an important area of focus on the way to reaching the energy goals set for the European Union. The relatively small share of new buildings makes renovation of existing buildings possibly the most feasible way of improving the overall energy performance of the building stock. This of course involves improvements on the climate shell, for example by additional insulation or change of window glazing, but also installation of new heating systems, to increase the energy efficiency and to fit the new heat load after renovation. In the choice of systems for heating, ventilation and air conditioning (HVAC), it is important to consider their performance for space heating as well as for domestic hot water (DHW), especially for a renovated house where the DHW share of the total heating consumption is larger. The present study treats the retrofitting of a generic single family house, which was defined as a reference building in a European energy renovation project. Three HVAC retrofitting options were compared from a techno-economic point of view: A) Air-to-water heat pump (AWHP) and mechanical ventilation with heat recovery (MVHR), B) Exhaust air heat pump (EAHP) with low-temperature ventilation radiators, and C) Gas boiler and ventilation with MVHR. The systems were simulated for houses with two levels of heating demand and four different locations: Stockholm, Gdansk, Stuttgart and London. They were then evaluated by means of life cycle cost (LCC) and primary energy consumption. Dynamic simulations were done in TRNSYS 17. In most cases, system C with gas boiler and MVHR was found to be the cheapest retrofitting option from a life cycle perspective. The advantage over the heat pump systems was particularly clear for a house in Germany, due to the large discrepancy between national prices of natural gas and electricity. In Sweden, where the price difference is much smaller, the heat pump systems had almost as low or even lower life cycle costs than the gas boiler system. Considering the limited availability of natural gas in Sweden, systems A and B would be the better options. From a primary energy point of view system A was the best option throughout, while system B often had the highest primary energy consumption. The limited capacity of the EAHP forced it to use more auxiliary heating than the other systems did, which lowered its COP. The AWHP managed the DHW load better due to a higher capacity, but had a lower COP than the EAHP in space heating mode. Systems A and C were notably favoured by the air heat recovery, which significantly reduced the heating demand. It was also seen that the DHW share of the total heating consumption was, as expected, larger for the house with the lower space heating demand. This confirms the supposition that it is important to include DHW in the study of HVAC systems for retrofitting.
Resumo:
Within the aging building stock of Europe, there is great potential of saving energy through renovation and upgrading to modern standards, and to thereby approach the internationally set goals of lower energy use. This paper concerns the planned renovation of the building envelope and HVAC systems in a multi-family house in Ludwigsburg, Germany. Five systemic HVAC solutions were compared, with special focus on two systems: A) Balanced ventilation with HRC + Micro heat pump, and B) Forced exhaust ventilation + Heat pump with exhaust air HRC + Ventilation radiators. Given the predicted heating demand and ventilation rate of the house after renovation, the performance of the two systems was compared, alongside three common systems for reference. Calculations were made using TMF Energi, a tool developed by SP Technical Research Institute of Sweden. Both systems A and B were found to have the lowest electrical energy use together with the ground source heat pump system for the assumed conditions. For other assumptions, including different climate and degree of insulation, some differences between these three systems were noted. Most significant is the increased electrical use of system B for higher heating loads due to limitations in the power available from the heat source, exhaust air, which is dependent on the ventilation rate.
Resumo:
In this paper, dynamic simulation was used to compare the energy performance of three innovativeHVAC systems: (A) mechanical ventilation with heat recovery (MVHR) and micro heat pump, (B) exhaustventilation with exhaust air-to-water heat pump and ventilation radiators, and (C) exhaust ventilationwith air-to-water heat pump and ventilation radiators, to a reference system: (D) exhaust ventilation withair-to-water heat pump and panel radiators. System A was modelled in MATLAB Simulink and systems Band C in TRNSYS 17. The reference system was modelled in both tools, for comparison between the two.All systems were tested with a model of a renovated single family house for varying U-values, climates,infiltration and ventilation rates.It was found that A was the best system for lower heating demand, while for higher heating demandsystem B would be preferable. System C was better than the reference system, but not as good as A or B.The difference in energy consumption of the reference system was less than 2 kWh/(m2a) betweenSimulink and TRNSYS. This could be explained by the different ways of handling solar gains, but also bythe fact that the TRNSYS systems supplied slightly more than the ideal heating demand.
Resumo:
Introducción. Los trabajadores de los talleres de reparación de automóviles conviven diariamente con la exposición a los solventes orgánicos, exposición que se convierte en un riesgo para su salud que generalmente en el corto plazo se presenta como déficits de concentración, memoria y tiempo de reacción y en el largo plazo produciendo graves repercusiones clínicas como efectos mutagénicos y carcinogénicos. Objetivo. Caracterizar las condiciones higiénicas y de seguridad de trabajadores ocupacionalmente expuestos a solventes orgánicos y determinar los niveles ambientales de benceno, tolueno y xileno (BTX) en talleres de lámina y pintura automotriz de la ciudad de Bogotá. Materiales y métodos. Se hizo un estudio de corte transversal en 60 trabajadores que laboran expuestos a solventes orgánicos en talleres de reparación automotriz en Bogotá. Se realizó una encuesta con variables sociodemográficas, laborales y se determinaron los niveles en aire de benceno, tolueno y xileno. Para los muestreos ambientales, las bombas se colocaron en una posición fija representativa del ambiente general, con el objeto de conocer la distribución de los solventes en el área de trabajo. Se realizó un análisis descriptivo por conteos de frecuencia, medidas de tendencia central y dispersión. Se utilizó prueba de bondad de ajuste para distribución normal (Kolmogorov-Smirnov o Shapiro Wilk), prueba t Student para comparación de medias, o en su defecto prueba U de Mann Whitney para comparación de medianas. Para identificar la relación entre las características sociodemográficas y ocupacionales con la exposición a BTX, se utilizaron pruebas de asociación Chi cuadrado o análisis de correlación según la naturaleza de las variables. El nivel de significancia para cada prueba fue 0.05. Resultados. La edad promedio de los trabajadores fue de 43 años y un tiempo total de exposición a solventes de 20 años. Respecto al uso de protección corporal, 45 (75%) de los trabajadores manifestaron que usaban uniforme, mientras que 14 (23,3%) usaban ropa de calle durante la jornada laboral. El 46,7% manifestaron usar protección respiratoria. La concentración de benceno en aire fue entre 0,1 y 0,45 mg/l (mediana de 0,31 mg/l; DE 0,13 mg/l); la de tolueno estuvo entre 8,25 y 27,22 mg/l (mediana de 14,5 mg/l; DE 6.99 mg/l) y la de xileno entre 19,34 y 150,15 mg/l (mediana de 70,12 mg/l; DE 40,82 mg/l). Conclusión. Los pintores de automóviles están expuestos a niveles elevados de solventes en los lugares de trabajo y no cuentan con condiciones de higiene y seguridad industrial adecuados. Un gran número de pintores son informales lo que les impide el acceso a los beneficios del Sistema de Seguridad Social Integral.
Resumo:
Understanding the transport mechanisms of aerosol particles in enclosures has broad ramifications in the context of cleaning strategies, and health risk assessment (e. g., occupational exposure). This paper addresses airflow pattern and aerosol transport mechanism in a ventilated two-zone enclosure with the outlet (exhaust location) situated at different locations. A numerical approach that combines a Eulerian simulation of turbulent flow with a Lagrangian particle-tracking algorithm is used. Simulations are carried out using solid suspensions with different sizes (1 to 100 micron) and densities (240 and 2300 kg/m3). The effect of location of the outlet (exhaust) on airflow patterns and aerosol dynamics is analyzed and quantified.
Resumo:
1 Doutora em Linguística e Língua Portuguesa pela Universidade Estadual Paulista "Júlio de Mesquita Filho", campus de Araraquara (1998). Professora Associado A, no Departamento de Letras Vernáculas da Universidade Estadual de Ponta Grossa. Atua no Mestrado em Linguagem, Identidade e Subjetividade desde 03/2010. 2 Mestranda em Estudos da Linguagem pela Universidade Estadual de Londrina (2012). Bolsista CAPES. Especialista em Língua, Linguística e Literatura pela Universidade Estadual de Ponta Grossa (2010) e graduada em Letras Português/Inglês pela mesma instituição (2006). As with societies, history and culture, language also evolves, a process which is inherent to it. The Portuguese of Brazil has its own characteristics due to the influence of Indian, African peoples and others who have lived here. This study researched 19th century handwritten letters for the origins of Brazilian Portuguese. The corpus consists of three personal letters collected by the Museu do Tropeiro in Castro. Two of them were written by the Baroness of Guaraúna and one by the Empress Thereza de Bourbon. This textual genre is Revista Línguas & Letras ISSN: 1517-7238 Vol. 13 nº 24 1º Sem. 2012 a valuable source for socio-historical studies because it brings, through the linguistic register, an immeasurable cultural and intellectual legacy. Studying the educated Portuguese Brazilian language, used informally between 1880 and 1893, one is able to notice syntactic phenomena, which are found in forms of treatment and spelling diversity characteristic of the century in which they were written. Our focus was not to exhaust all the possibilities of analysis and observation on the origin of this entire legacy but to contribute towards the studies of the history of Brazilian Portuguese, and in particular, the one from the state of Paraná.
Resumo:
This paper presents some discussions on the theoretical and methodological principles of the studies on language variation. The reflections take the socio-historical context as an element that affects the performance of speech time and space. Language, more specifically its realization in speech, is taken as belonging to the social order, i.e., as an element that relates to the way of life of individuals, groups and societies, which, through social networks and their entanglements, depict the dynamic and complex set of social relations. Registered in its most alive realization, speech is the axis to which converge multiple connections and different levels of society. This dynamic relationship between language and society, according to the studies of Sociolinguistics and Dialectology, provides the elements for examining the phenomena manifested in speech. The theoretical and methodological approach delineated in this paper does not exhaust the principles that underpin the studies on variation, but it congregates some reflections on the conditions in which the language description can provide elements for a review of the behavior of speakers given the history and culture of the community.