941 resultados para Dose de Referência


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência da Informação - FFC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: With the invention of the Internet and the Collaborative Web, libraries had to rethink the way to offer their services. Thus, the U.S. libraries began a search for technological innovations in an effort to bring the library to the user through features that patrons commonly use. The Virtual Reference Service (VRS) through chat and reference services via videoconferencing are features that derived from this search. Objective: This article aims to outline the implementation process of Virtual Reference Services (SRV) libraries in American universities, particularly those for chat, as well as presenting the successful Brazilian experience. This paper also discusses factors to be considered for implementing virtual reference service via chat for libraries wishing to offer the service. Methodology: The research methodology is based on a theoretical search on international and national literature on the subject. The methodology also includes participant observation. Results: In Brazil the implementation of SRV in some university libraries has occurred and according to these institutions, the SRV is a service that benefits the community and puts the library in line with the demands of information technology and communication. Conclusions: It is concluded that online SRV is appropriate to the reality of university libraries in Brazil, since the institutions that offer the service have positive results from their assessments and believe they are adding value to their library.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information Science has for its object of study the general properties of information and analysis of their construction, communication and use processes. Organic information, one of the information types, is the one recorded in the archives, which can be split into two distinct groups based on users: current and permanent, used by administrators, historians/citizens, respectively. After defining the information behavior of each group, the articles directs the discussion to the mediation of information in the permanent archives. The interaction between user and information professionals through references services aiming the user needs is presented. In addition, the standards of archival description and the research instruments as tools to reference service are discussed. Moreover, it argues the importance of information technologies and the new possibilities for the promotion of organic information in permanent archives, especially concerning the information architecture of websites and the conversion of the DTD standards of archival descriptions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Materiais estruturais utilizados no projeto de equipamentos e instalações industriais podem apresentar mudança de seu comportamento à fratura quando se varia a temperatura. Este tipo de comportamento caracteriza-se pela existência de uma curva de transição, onde 3 regiões ficam bem definidas: os patamares inferior e superior e a região de transição. Na região de transição, os resultados experimentais apresentam alto espalhamento e são bastante dependentes da geometria ensaiada. Para solucionar este problema, foi desenvolvido um modelo analítico experimental, que resultou na edição da norma ASTM E1921-97. O trabalho inclui um estudo da influência de diversas rotas de tratamentos térmicos aplicadas em um aço 4130 utilizado pela indústria aeronáutica, um aço de qualidade API utilizado pela indústria petrolífera e um aço da classe A516 atualmente utilizado pela indústria nacional de vasos de pressão, na microestrutura, propriedades mecânicas de tração e tenacidade à fratura. Os resultados mostraram que o aço 4130 A450, apresentou a melhor correlação entre resistência e tenacidade entre as microestruturas pesquisadas. Este comportamento deve estar associado a rota de tratamento térmico aplicada a esta condição. O tratamento de austêmpera possibilita a formação de bainita que, tradicionalmente é conhecida por apresentar elevados valores de tenacidade. O método proposto pela ASTM pode ser considerado viável para as diversas microestruturas pesquisadas ampliando a aplicação da metodologia que recomenda o ensaio apenas para aços ferríticos. No entanto, a metodologia da Curva Mestra em materiais tratados termicamente deve ser conduzida de forma a se estabelecer parâmetros que considerem as modificações microestruturais sofridas pelo material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this project is the reproduction, through the simulation code based on the MCNPX (Monte Carlo N-Particle eXtended) v2.50 method, of the proton beam interaction with the material, since, in proton therapy, only the particle ionization and excitation are analyzed and the occurence of nuclear interactive inelastic process are not considered. This work will help the development of studies concerning the contribution to the total dosis of secondary particles generated by nuclear interaction in proton therapy. They are: alpha particles ( ), deuterium(2H), tritium (3H), neutron (n) and helium (3He). A MS20 tissue substitute phantom was used as the target and the energy of the proton beams was within an interest range of 100 to 200MeV. With the results obtained, it was possible to generate graphics which allows the analysis of the dosis deposition relation with and without nuclear interaction, the percentage of secondary particles deposited dosis, the radial dispersion of neutrons in the material, the secondary particles multiplicity, as well as the relation between the secondary particles spectrum with the próton generated spectrum

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brachytherapy braquiterapia is an x-ray modality radiotherapy in which stamped or halfstamped radioactive sources in format of seeds are used, wires or to one short distance, in contact or implanted to the fabric to be treated. All the treatment modalities require a previous planning. The formalism recommended for calculation of dose was considered by the AAPM for the first TG-43 Report. In it distributions of dose of isolated seeds measured and calculated by Monte Carlo method in water instead of with models half-empiricists. In this work we in accordance with present some preliminary results of the calculation of functions of radial anisotropy and of dose in the distance for seed of 192Ir, wide used in brachytherapy treatments of high tax of dose (HDR), with the aid of the program based on the Monte Carlo method MCNPX v2.50 (Mount Carlo N ParticleeXtended). The materials chosen in the simulation beyond water, had been MS20 and estriado muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brachytherapy braquiterapia is an x-ray modality radiotherapy in which stamped or halfstamped radioactive sources in format of seeds are used, wires or to one short distance, in contact or implanted to the fabric to be treated. All the treatment modalities require a previous planning.The formalism recommended for calculation of dose was considered by the AAPM for the first TG-43 Report. In it distributions of dose of isolated seeds measured and calculated by Monte Carlo method in water instead of with models half-empiricists.In this work we in accordance with present some preliminary results of the calculation of functions of radial anisotropy and of dose in the distance for seed of 192Ir, wide used in brachytherapy treatments of high tax of dose (HDR), with the aid of the program based on the Monte Carlo method MCNPX v2.50 (Mount Carlo N ParticleeXtended).The materials chosen in the simulation beyond water, had been MS20 and estriado muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy is a multidisciplinary speciality which uses complex equipment and radiation sources for delivery of treatment, using high-energy ionizing radiation to treat cancer at several stages of complexity. Since radiation therapy is a technique which involves a precalculated radiation dose, it shall be established quality assurance programs that provide an efficient and safety treatment. The International Commission on Radiation Units and Measurements (ICRU) report No. 50 has recommended dose uniformity between 5% of the prescribed dose throughout the region of interest. This is one of the most primordial points that justify the importance of a suitable attendance of the equipments quality and performance. For quality control, the medical physicist will be involved with establishing and running a Quality Control Program (QCP). He must adapt or develop the procedures of equipment acceptance and commissioning, besides verifying the use of principles and accepted protocols of national and international reports to assure the correct quality, quantity, and placement of radiation during the performance of a radiological procedure, establishing adequate protocols to ensure accurate patient dosimetry. This present work consists of a description of the activities carried through the Sectors of Radiation Therapy of the Hospital of Clinics of the Campinas State University (Unicamp), particularly in the implementation of the Quality Control Program