900 resultados para Difference method for differences


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Topical retinoids are used to treat photoaging; oral isotretinoin is gold standard for acne; off label indications, including photoaging, have been reported with insufficient evidence of efficacy. This is a randomized controlled phase II trial with clinical and histological assessment to evaluate efficacy and safety of oral isotretinoin for photoaging. Study population was comprised of 32 menopausal or sterilized women, aged 40-55, divided in 2 groups: A (21) received 20mg isotretinoin, 3 times per week, nightly moisturizer, and daily sunscreen, for three months; B (11) just moisturizer/sunscreen. Main outcome measures were: overall clinical assessment; profilometry, corneometer and elasticity tests in periocular regions and left forearm; before/after biopsies from left forearm in patients of B and in 10 randomly selected of A. Microscopic blinded evaluation of epidermal thickness, dermal elastosis, new collagen, p53 epidermal expression was performed by quantitative digital image analysis. All data were submitted to statistical analysis. Clinical evaluation showed slight improvement; profilometry, corneometer and skin elasticity tests presented significant difference in pre/post values (P = 0.001 to 0.028), but no differences between A/B. Histological findings and p53 expression were comparable between groups before treatment (P > 0.1); microscopic analysis showed no differences between groups for most variables, after treatment. Slight but significant difference between A/B for p53 with major reduction post isotretinoin [0.66±0.31 vs. 0.94±0.34 respectively (P = 0.04) was observed. There were minor side effects and no significant laboratory test alterations. We concluded that no significant clinical, microscopic changes but p53 epidermal expression reduction were observed. The role of ultra-violet induced p53 mutation in skin carcinogenesis reinforces retinoids chemoprevention. Oral isotretinoin seemed safe but not effective to treat photoaging. Caution should be considered for women prone to pregnancy. Further controlled studies are necessary. © 2010 The International Society of Dermatology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: This study aimed to compare the safety and analgesic efficacy of a new topical drug (in two different presentations: cream and aerosol) consisting of benzocaine, menthol and triclosan, in the curettage of molluscum contagiosum. Method: The study included 296 volunteers in different stages: 256 healthy adult volunteers for the safety evaluation, and 40 volunteers between 2 and 12 years old who presented Molluscum contagiosum, for the evaluation of tolerability and efficacy. Each volunteer represented two experimental units (left and right) where it was applied randomly the tested products (cream or aerosol) 30 minutes before the dermatological curettage, immediately after and twice a day during 7 days. Dermatological evaluations of safety and efficacy were performed immediately after the procedure, 3 and 7 days after the curettage. Results: During safety evaluation, the tested products showed no irritant, sensitizing, phototoxic or photosensitizing potential. Both presentations, cream and aerosol, were considered safe with no statistically significant differences between them. With respect to analgesic efficacy, the results showed that the medication promoted the reduction of painful symptoms and there was no statistically significant difference (p <0.05) between the two presentations. Conclusion: The tested product, in two different presentations, was considered safe and effective in controlling pain symptoms during and after the curettage of molluscum contagiosum. © Copyright Moreira Jr. Editora.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Several anti-inflammatory drugs have been used to reduce pain and discomfort after periodontal surgeries. This study evaluates the efficacy of using etoricoxib and dexamethasone for pain prevention after open-flap debridement surgery. Methods: For this prospective, double-masked, crossover, placebo-controlled, randomized clinical trial, open-flap debridement surgeries were performed on 15 patients (eight males and seven females, age range 20 to 56 years: mean age ± SD: 40 ± 9.7 years) who presented with chronic periodontitis after nonsurgical periodontal therapy at three quadrants. Each patient underwent three surgical procedures at intervals of 30 days and received one of the following premedication protocols 1-hour before surgery: group 1 = placebo, group 2 = 8 mg dexamethasone, and group 3 = 120 mg etoricoxib. Rescue medication (750 mg acetaminophen) was given to each patient who was instructed to take it when necessary. Pain intensity and discomfort were evaluated by a 101-point numeric rate scale and a four-point verbal rate scale, respectively, hourly for the first 8 hours after surgery and three times a day on the following 3 days. Results: The results demonstrate that groups 2 and 3 present reduced postoperative pain-intensity levels compared to group 1. There were statistically significant differences at the 4, 5, 6, 7, and 8 hour-periods after surgery (Friedman test; P<0.05). Furthermore, rescue-medication intake was significantly lower for groups 2 and 3 than for group 1 (analysis of variance; P<0.02). Conclusion: The adoption of a preemptive medication protocol using etoricoxib or dexamethasone may be considered effective for pain and discomfort prevention after open-flap debridement surgeries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

the aim of this study was to validate the Alternate Current Biosusceptometry (ACB) for monitoring gastric contractions in rats. In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed on rats with magnetic markers and SGs previously implanted under the gastric serosa. The effects of the prandial state in gastric motility profiles were obtained. The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation between the ACB and SG signal amplitude was higher in the postprandial than in the fasting state. Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation for fasting-state recordings. The contraction frequencies using ACB were 0.068 ± 0.007 Hz (postprandial) and 0.058 ± 0.007 Hz (fasting) and those using SG were 0.066 ± 0.006 Hz (postprandial) and 0.059 ± 0.008 Hz (fasting) (P < 0.003). When a magnetic tracer was ingested, there was a strong correlation and a small phasedifference between techniques. We conclude that ACB provides an accurate and sensitive technique for studies of GI motility in the rat. © 2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: evaluating the adequacy, prescription and energy supply of enteral nutrition therapy in hospitalized patients. Methods: was performed a retrospective survey of the evolution of TNE protocol of 59 patients hospitalized in a general hospital in Marília / SP / BR. Data collected included gender, age, clinical diagnosis, anthropometric and dietary data related to the prescribed dietary formula, route and method of administration of the enteral nutrition, the daily volume prescribed and administered, the daily amount of energy required and offered in the diet, as well as possible complications. Body mass index (BMI), triceps skinfold (TSF) and arm muscle circumference (AMC) were used to establish the nutritional status of the patients. The adequacy of ENT was done according to the daily energy requirement compared to the average energy received during the daily use of ENT. Results: The average found to the BMI was 21.4 kg/m 2, and no differences were found comparing male and female. The data for TSF and AMC were different between genders (p<0.05) and suggest a more severe muscle mass in relation to adipose tissue. The averaged to the energy requirements was 1642 kcal/day but the average of energy prescribed was 1045 kcal/day and the amount offered was 1035 kcal/day. There was a significant difference between the necessity and the supplied energy offered through enteral nutrition (p=0.00) as well between the energy required and prescribed (p =0.00), both were shorter than the necessity. There was no significant difference (p>0.05) in energy supply, volume of enteral nutrition prescribed and administered among eutrophic, underweight or overweight patients. Conclusion: The results of this study indicate that the prescription and energy supply were not based on the needs of these patients, causing a significant energy deficit, which can lead to worsening of the nutritional status of the same. In hospitalized patients in use of ENT, the energy requirement must be made by a qualified professional within the multidisciplinary team, based on the needs of each patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed at developing radiographic techniques for the early detection of dyschondroplastic lesions in the tibia of broilers. The experiment was carried out at the facilities of UNIFOR/MG and Formiga and UNIFENAS/ Alfenas with 420 one-day-old male Cobb broilers. At 20 days of age, all birds were radiographed and identified with an alpha-numeric metal ring in the right leg. At 40 days of age, 42 broilers previously selected as a function of bone mineral density and lesion thickness scores were again radiographed and scored, and then sacrificed. Their right tibia was removed for gross and histological examination of the growth plate. The results showed that radiographic techniques are correlated with gross and histological examination and that there was no significant differences among techniques (P>0.05). it was concluded that the use of radiographic examination to identify tibial dyschondroplasia in broilers precludes the use of bone mineral density to diagnose this condition. The non-parametric statistical Chi-square test at 5% significance level was used to analyze the results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work evaluated the effects of high moisture silage, extrusion and corn and sorghum drying with and without tannin, on the chemical composition and ruminal digestion of dry matter. The experimental design was completely randomized in 3x3 factorial scheme (kinds of grains: processing), for the chemical composition and degradability and three blocks (animals) through in situ method. It was verified significant difference between kinds of grains and processing in relation to the chemical composition, except for crude protein and mineral matter. The contents of etherextract in the three types of grains, were reduced significantly with the high moisture silage, extrusion and drying in relation to the humid material. For the contents of phenols, total and condensed tannin there was effect of hybrid, processing and interaction, and the most elevated contents were found in sorghum with tannin. Although grain composition has been similar, the interaction in ruminal ambient associated to the tannin, promoted differences in the dry matter degradability. It was concluded that sorghum without tannin may be ensiled or extruded, while the sorghum with tannin, must be extruded to improve the degradability and availability of nutrients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Colour stability of resin and silicone is an important factor for longevity of facial prostheses. The aim of this study was to evaluate the colour stability of resins and silicone for facial prostheses. Three brands of acrylic resin and one of facial silicone were evaluated considering pigment incorporation for the colourless materials. Ten samples of each material were fabricated and submitted to measurements of chromatic alteration initially and after 90 and 180 days of weathering natural through visual analysis and spectrophotometry. Data were evaluated by ANOVA and Tukey test (p < 0.05). Statistically significant colour alteration was observed among some materials regardless of the period. The materials did not present a statistical difference between 90 and 180 days except for the pigmented heat-polymerized resin. The colour difference between pigmented Silastic MDX4-4210 and colourless Silastic was statistically significant (p < 0.01) in both periods as well as between pigmented and colourless heat-polymerized resin, and between the resins Rapidaflex and Lentaflex. The visual method demonstrated colour alteration in all materials evaluated during the first 90 days of ageing. All materials exhibited colour alteration due to exposure to environment. © 2012 Informa UK, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study evaluated the reliability and failure modes of implants with a microthreaded or smooth design at the crestal region, restored with screwed or cemented crowns. The postulated null hypothesis was that the presence of microthreads in the implant cervical region would not result in different reliability and strength to failure than smooth design, regardless of fixation method, when subjected to step-stress accelerated life-testing (SSALT) in water. Materials and methods: Eighty four dental implants (3.3 × 10 mm) were divided into four groups (n = 21) according to implant macrogeometric design at the crestal region and crown fixation method: Microthreads Screwed (MS); Smooth Screwed (SS); Microthreads Cemented (MC), and Smooth Cemented (SC). The abutments were torqued to the implants and standardized maxillary central incisor metallic crowns were cemented (MC, SC) or screwed (MS, SS) and subjected to SSALT in water. The probability of failure versus cycles (90% two-sided confidence intervals) was calculated and plotted using a power law relationship for damage accumulation. Reliability for a mission of 50,000 cycles at 150 N (90% 2-sided confidence intervals) was calculated. Differences between final failure loads during fatigue for each group were assessed by Kruskal-Wallis along with Benferroni's post hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value (confidence interval range) derived from use level probability Weibull calculation of 1.30 (0.76-2.22), 1.17 (0.70-1.96), 1.12 (0.71-1.76), and 0.52 (0.30-0.89) for groups MC, SC, MS, and SS respectively, indicated that fatigue was an accelerating factor for all groups, except for SS. The calculated reliability was higher for SC (99%) compared to MC (87%). No difference was observed between screwed restorations (MS - 29%, SS - 43%). Failure involved abutment screw fracture for all groups. The cemented groups (MC, SC) presented more abutment and implant fractures. Significantly higher load to fracture values were observed for SC and MC relative to MS and SS (P < 0.001). Conclusion: Since reliability and strength to failure was higher for SC than for MC, our postulated null hypothesis was rejected. © 2012 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this research was to analyze and measure, under optical microscopy, the hybrid layer thickness and resin tags length, as well as the microtensile bond strength of two conventional adhesive systems when applied to dry and moist dentinal substrate. Methods: Thirty-two extracted human molars were randomly distributed into four groups according to the adhesive systems (XP Bond and Prime&Bond 2.1) and moisture condition (dry and moist). In Groups I and II, XP adhesive system was applied on dry and moist dentin, respectively; while Groups III and IV received PB adhesive system, in the same way as was done in Groups I and II, respectively. After adhesive and restorative procedures, all specimens were sectioned along their long axes; one hemi-tooth sample was subjected to the microtensile bond strength test while the other was decalcified and serially sectioned into six micron thick slices and sequentially mounted on glass slides. These sections were stained by the Brown and Brenn method for posterior analysis and measurement of the hybrid layer and resin tags under a light microscope with a micrometric ocular 40/075. Results: Data were analyzed using two-way ANOVA and Tukey's test (α=0.05). For the variable hybrid layer thickness, XP showed no significant differences between dry and moist dentin (5.2 μm and 5.5 μm, respectively), but for PB, hybrid layer was significantly thicker for moist (4.0 μm) than for dry dentin (3.0 μm). For the variable resin tags length XP showed 17.9 μm length for dry dentin and 20.8 μm for moist dentin; PB 11.7 μm for dry and 12.69 μm for moist dentin;there was no significant differences between them, independent of the moisture condition. For the variable microtensile bond strength, XP showed 38.0 MPa for dry dentin and 44.5 MPa for moist dentin; and PB showed 22.7 MPa for dry dentin and 20.8 MPa for dry dentin no significant difference was observed between moist and dry dentin for XP (p=0.2) and PB (p=0.7), but XP was presented significantly higher bond strength values than PB in both moisture conditions (p=0.003 for dry and p=0.002 for moist). Conclusion: The two-step butanol-based etch-and-rinse adhesive XP Bond presented a superior behavior with regard to the hybrid layer thickness, length of resin tags and bond strength to dry and moist dentin substrates when compared with two-step acetone-based adhesive system Prime&Bond2.1. © 2013 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the effects of surface treatment, surface hydration (SH) and application method (AM) on the tensile bond strength of the Silorane Adhesive System (SAS) to dentine. Methods: Ninety bovine teeth were used. For the control group (n = 10), each dentine surface was treated according to the manufacturer's instructions of the SAS. The remaining teeth were randomly distributed into two groups (n = 40), according to the type of dentine surface treatment (ST) - 37% phosphoric acid or Er:YAG Laser prior to the application of the SAS. Each group was further divided into 2 subgroups (n = 20), according to the SH status: dry (D) or wet (W). Each subgroup was further divided into 2 subgroups (n = 10), according to the application method [AM: Active (AC) mode or Passive (PA) mode]. A coat of resin composite (Filtek P90) was applied on the surface. Artificial ageing was performed with a thermo-mechanical cycling machine. The specimens were sectioned into 1 mm × 1 mm × 10 mm sticks and stressed to failure using a universal testing machine. The remaining teeth in each group were used for Scanning Electron Microscopy to examine the fractured area. Data were subjected to a three-way ANOVA, Tukey's test and Dunnet's test (α = 0.05). Results: The ANOVA showed significant differences for SH and AM, but not for ST. For SH, the results of Tukey's test were (in MPa): D-14.9(±3.8)a, W-17.1(±4.3)b; and for AM: PA-14. 9(±4.2)a, AC-17.1(±3.9) b. Conclusions: Acid etching, when combined with a moist dentine surface and the use of primer agitation, improves the bond strength of the SAS to dentine. Clinical Significance: According to the results of the present in vitro study, modification of the application protocols for the silorane-based adhesive system may improve its clinical performance. © 2012 Published by Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Previous studies with long-term average spectrum (LTAS) showed the importance of the glottal source for understanding the projected voices of actresses. In this study, electroglottographic (EGG) analysis was used to investigate the contribution of the glottal source to the projected voice, comparing actresses and nonactresses' voices, in different levels of intensity. Method: Thirty actresses and 30 nonactresses sustained vowels in habitual, moderate, and loud intensity levels. The EGG variables were contact quotient (CQ), closing quotient (QCQ), and opening quotient (QOQ). Other variables were sound pressure level (SPL) and fundamental frequency (F0). A KayPENTAX EGG was used. Variables were inputted in a general linear model. Results/Discussion: Actresses showed significantly higher values for SPL, in all levels, and both groups increased SPL significantly while changing from habitual to moderate and further to loud. There were no significant differences between groups for EGG quotients. There were significant differences between the levels only for F0 and CQ for both groups. Conclusion: SPL was significantly higher among actresses in all intensity levels, but in the EGG analysis, no differences were found. This apparently weak contribution of the glottal source in the supposedly projected voices of actresses, contrary to previous LTAS studies, might be because of a higher subglottal pressure or perhaps greater vocal tract contribution in SPL. Results from the present study suggest that trained subjects did not produce a significant higher SPL than untrained individuals by increasing the cost in terms of higher vocal fold collision and hence more impact stress. Future researches should explore the difference between trained and nontrained voices by aerodynamic measurements to evaluate the relationship between physiologic findings and the acoustic and EGG data. Moreover, further studies should consider both types of vocal tasks, sustained vowel and running speech, for both EGG and LTAS analysis. © 2013 The Voice Foundation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The participation of children and adolescents in sports, including basketball, is becoming increasingly common, and this increased involvement raises concerns about the potential risk of sports injuries. Objective. To analyze the occurrence of sports injuries among young basketball players according to their position on the court and to associate these injuries with risk factors. Method. A retrospective, epidemiological study. A sample consisting of 204 basketball players with a mean age of 14.33 ± 1.19 years participated in the study. The players were interviewed using a reported condition questionnaire containing anthropometric and training data as well as information on injuries during the previous 12 months. Results: The frequency of injury was highest among the shooting guards (47.8%), followed by the centers (34.8%) and point guards (17.4%). Among the 204 participants, 40 players reported a total of 46 injuries, representing 0.22 injuries per participant and 1.15 injuries per injured participant. For the shooting guards and centers, statistically significant differences between injured and non-injured players were found related to age, weight, height, length of time in training and number of weekly practice hours (p < 0.05). For point guards, a statistically significant difference between injured and non-injured players was found based on weight alone (p < 0.05). Conclusion: The occurrence of injuries among basketball players was low. Injuries were associated with both intrinsic and extrinsic factors among shooting guards and centers, whereas injuries were only associated with weight among point guards. © 2013 Vanderlei et al; licensee BioMed Central Ltd.