Effects of surface treatment, hydration and application method on the bond strength of a silorane adhesive and resin system to dentine


Autoria(s): Pucci, Cesar R.; De Oliveira, Rodrigo S.; Caneppele, Taciana M.F.; Torres, Carlos R.G.; Borges, Alessandra B.; Tay, Franklin R.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

27/05/2014

27/05/2014

01/03/2013

Resumo

Objectives: To evaluate the effects of surface treatment, surface hydration (SH) and application method (AM) on the tensile bond strength of the Silorane Adhesive System (SAS) to dentine. Methods: Ninety bovine teeth were used. For the control group (n = 10), each dentine surface was treated according to the manufacturer's instructions of the SAS. The remaining teeth were randomly distributed into two groups (n = 40), according to the type of dentine surface treatment (ST) - 37% phosphoric acid or Er:YAG Laser prior to the application of the SAS. Each group was further divided into 2 subgroups (n = 20), according to the SH status: dry (D) or wet (W). Each subgroup was further divided into 2 subgroups (n = 10), according to the application method [AM: Active (AC) mode or Passive (PA) mode]. A coat of resin composite (Filtek P90) was applied on the surface. Artificial ageing was performed with a thermo-mechanical cycling machine. The specimens were sectioned into 1 mm × 1 mm × 10 mm sticks and stressed to failure using a universal testing machine. The remaining teeth in each group were used for Scanning Electron Microscopy to examine the fractured area. Data were subjected to a three-way ANOVA, Tukey's test and Dunnet's test (α = 0.05). Results: The ANOVA showed significant differences for SH and AM, but not for ST. For SH, the results of Tukey's test were (in MPa): D-14.9(±3.8)a, W-17.1(±4.3)b; and for AM: PA-14. 9(±4.2)a, AC-17.1(±3.9) b. Conclusions: Acid etching, when combined with a moist dentine surface and the use of primer agitation, improves the bond strength of the SAS to dentine. Clinical Significance: According to the results of the present in vitro study, modification of the application protocols for the silorane-based adhesive system may improve its clinical performance. © 2012 Published by Elsevier Ltd.

Formato

278-286

Identificador

http://dx.doi.org/10.1016/j.jdent.2012.11.016

Journal of Dentistry, v. 41, n. 3, p. 278-286, 2013.

0300-5712

http://hdl.handle.net/11449/74668

10.1016/j.jdent.2012.11.016

WOS:000316179000011

2-s2.0-84875222821

Idioma(s)

eng

Relação

Journal of Dentistry

Direitos

closedAccess

Palavras-Chave #Dentine #Er:YAG laser #Microtensile bond strength #Silorane self-etch adhesive
Tipo

info:eu-repo/semantics/article