1000 resultados para Determinação de minoxidil
Resumo:
This work deals with the method validation for the determination of acetic, propionic and butyric acids (VFAs) in wastewaters from anaerobic reactors by HPLC-DAD. Separation was performed using a C18 column and the mobile phase composition were water pH 3.0 and methanol 90:10 (v/v). The detection and quantification was carried out at 220 nm. The method shows good linearity (r²>0.996), with adequate accuracy (89-102%) and relative standard deviations lower than 18%. The matrix effect was considered low (-4.1, -3.9 and 1.4%). The developed method is fast, simple and cheap; and it was applied in wastewater samples from anaerobic reactor.
Resumo:
Asphaltenes are fractions of crude oils that can precipitate and one of the parameters used in the prediction of the conditions in which this phenomenon occurs is the Hildebrand solubility parameter. In this work, it was evaluated the uncertainty propagation in the experimental determination of the solubility parameter of different crude oils, calculated from data of the asphaltenes precipitation by the addition of n-heptane, identified by optical microscopy. It was verified that the solubility parameter of an oil and the associated uncertainty are specific, being recommended that, whenever viable, it is determined parallel both, conferring higher credibility to the results.
Resumo:
A method for simultaneous analysis of trihalomethanes and organochloride and pyrethroid pesticides in water utilizing SPME-HS and GC-ECD was developed. In the optimized method 25 mL of water containing 2% (w/v) Na2HPO4 were heated to 60 °C for 50 min. The fiber (PDMS - 100 μm) was exposed to a headspace for the same period. For all analytes it was found that LOQ < MCL (Maximum Contaminant Level), CV < 20% and r > 0.9. The method was applied to potable and surface water samples. Some trihalomethanes were encountered in potable waters, at levels below the MCL.
Resumo:
Multivariate models were developed using Artificial Neural Network (ANN) and Least Square - Support Vector Machines (LS-SVM) for estimating lignin siringyl/guaiacyl ratio and the contents of cellulose, hemicelluloses and lignin in eucalyptus wood by pyrolysis associated to gaseous chromatography and mass spectrometry (Py-GC/MS). The results obtained by two calibration methods were in agreement with those of reference methods. However a comparison indicated that the LS-SVM model presented better predictive capacity for the cellulose and lignin contents, while the ANN model presented was more adequate for estimating the hemicelluloses content and lignin siringyl/guaiacyl ratio.
Resumo:
The gravimetric and electrochemical tests are the most common techniques used in determining the corrosion rate. However, the use of electrochemical polarization is limited to electrolytes with sufficient conductivity for which Tafel curves are linear. In this study, we investigated a technique in which working microelectrodes of AISI 1020 steel were used to obtain the Tafel curves in diesel oil. The strategy was to reduce the electrode area and hence the ohmic drop. The diameter of the microelectrode was reduced to a value where the compensation of the Tafel curves became unnecessary. The results showed that for electrodes with diameters below 50 μm, the ohmic drop tends to a minimum and independent of the microelectrode diameter.
Resumo:
The sulphur take an essential role in plants and it is one of the main nutrients in several metabolic processes. The dry ash oxidation, using alkaline oxidizers agent, is the simplest and most economical form for the oxidation of Organic S to sulfate in plants. The objective of this work is to propose a method for sulfur determination in plants samples using dry ash oxidation and agent oxidizers alkaline. The quantification of S-SO4(2-) in samples was accomplished by turbidimetric method. The results demonstrated that the proposed method for oxidation alkaline was appropriate.
Resumo:
The present work describes the determination of polychlorinated biphenyls in 123 umbilical cord serum samples by liquid-liquid extraction method with acid hydrolyze step and analysis by GC-mECD. The analytical method was evaluated with following figures of merit for all PCBs: linearity (>0.997); precision (<12.55%); recoveries (73-119%); limit of detection (0.1 ng mL-1); limit of quantification (0.25-0.5 ng mL-1). The results showed high contamination in the analyzed samples. PCB more frequent was 138 (66.7%), followed by 180 (55.3%) and 52 (51.3%).
Resumo:
This review reports the use of solid amalgam electrodes in the electroanalytical determination of organic and inorganic compounds. The different types of amalgam electrodes are presented, and attention is paid to solid amalgam electrode, and here is presented details about the pre-treatment for activation and renovation and also possible modifications in its surface. The wide potential range, higher signal-to-noise ratio, mechanical stability enabling their application in flowing systems, and principally their resistance toward passivation, indicate that the solid amalgam electrodes are environmentally friendly alternatives to mercury electrodes, without loss in the sensitivity and reproducibility in voltammetric responses.
Resumo:
Simvastatin is an oral anti-hyperlipidemic that has been widely used to reduce the cardiovascular disease risk. There isn't any pharmacopoeic method to assay this drug in capsules. It was proposed and validated a method for determining the content of simvastatin in capsules by UV/visible spectrophotometry (l = 237 nm), a more affordable method for the compounding pharmacy. The method was validated for linearity, specificity, range, accuracy, precision, performance, robustness, and limits of detection and quantification.
Resumo:
A multivariate spectrophotometric method was developed for analysis of kojic acid/hydroquinone associations in skin whitening cosmetics. The method is based on the reaction between kojic acid and Fe3+ and on the reduction of Fe3+ by hydroquinone and further complexation of Fe2+ with 1,10-phenanthroline. The multivariate model was developed by Partial Least Squares Regression (PLSR), using 25 synthetic mixtures and mean-centered spectral data (350-380 nm). The use of 3 (kojic acid) and 2 (hydroquinone) latent variables permits the observation of mean errors of about 5% in the external validation phase.
Resumo:
The objective in this work was to validate a chromatography method for the determination of total carbohydrates in soluble coffee, using a HPLC-UV-VIS with postcolumn derivatization system, in order to verify adulterant additions. The validated method was accurate and robust. Adulteration could be observed by increasing xylose and glucose levels in samples with addition of coffee husks and starchy products while decreasing of galactose and mannose characteristic carbohydrates presenting in high concentration in soluble coffees produced by arabica and robusta coffee beans.
Resumo:
An evaluation of the pesticides extraction from onion using a modern sample preparation method (QuEChERS) and determination by liquid chromatography tandem mass spectrometry was carried out. All the calibration curves showed r>0.99. The recoveries ranged between 61.8 and 120.0% with relative standard deviation lower than 20% for all compounds. Due to the occurrence of matrix effect, the quantification was performed using matrix-matched calibration. The limits of quantification of the method were between 0.0005 and 0.05 mg kg-1. The method shows the advantages of not require the clean-up step and consume low volume of organic solvents, decreasing time, costs and residues.
Resumo:
A factorial design applied in a voltammetric stripping method for the measurement of Ag(I) in natural water is described. The procedure is based on the effective pre-concentration of silver ions on electrode surface. The calibration graph was linear in the silver concentration range from 7.92 x 10"7 to 1.07 x 10"5 mol L"1 with a detection limit of 3.81 x 10-7 mol L-1. The determination of Ag(I) in natural water samples was carried out satisfactory with the proposed electrode.
Resumo:
Analysis of seven pesticides in sediments was successfully achieved using comprehensive two-dimensional gas chromatography with micro-electron capture detection, as it provided higher sensitivity and less matrix interference. Repeatability and intermediate precision of peak areas and heights were less than 4% and the recovery percentage for the analytes ranged from 52 to 115%. Instrumental LOD and LOQ were in the range of 0.60 to 2.31 μg L-1 and 1.83 to 5.62 μg L-1, respectively. Concentrations of 3.34 μg kg-1 (dry basis) for trifloxystrobin and azoxystrobin (below the LOQ) were found in a sediment sample.
Resumo:
A simple flow-injection amperometric procedure using a three-electrode-integrated sensor for the determination of H2O2 in antiseptic mouthwash is reported. This method involves the use of a working composite electrode modified with Prussian Blue (PB) particles that was easily adapted as detector in FIA. The best amperometric response was observed for a composite containing 30% of graphite modified with PB particles (GAP) and 70% of pure graphite (GR). The proposed method presents a linear response in the range of 10 to 200 μmol L-1. The detection and quantification limits were 0.8 and 2.6 μmol L-1, respectively.