998 resultados para CASTE DETERMINATION
Resumo:
Graphite powder-supported nickel(II) hexacyanoferrate (NiHCF) was prepared by the in situ chemical deposition method and then dispersed into methyltrimethoxysilane-derived gels to form a conductive composite. The composite was used as electrode material to construct a surface-renewable three-dimensional NiHCF-modified carbon ceramic electrode. Electrochemical behavior of the chemically modified electrode was well characterized using cyclic and square-wave voltammetry. The electrode presented a good electrocatalytic activity toward the oxidization of thiosulfate and thus was used as an amperometric sensor for thiosulfate in the photographic waste effluent. In addition, the electrode exhibited a distinct advantage of surface-renewal by simple mechanical polishing, as well as simple preparation, good chemical and mechanical stability. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
A method for the determination of impurity elements in high purity cadmium by inductively coupled plasma mass spectrometry was developed. The spectral interference arising from Cd was discussed and the magnitude of interference by the polyatomic ion of Cd was compared. The effect of the high concentration Cd on the analyte signal was studied. The results showed that Cd possessed both significant suppression effects on the light mass elements signal and enhancement effects on the heavy mass elements signal,and the effects can be corrected by the use of internal standard elements. In this paper, Y and Bi was employed for the light mass elements and the heavy mass elements,respectively. As, Be, Co, Cu, Ga, Ge, Mn, Mo, Pb, Ni, Sr, Au, Tl, Th, V and U in high purity cadmium were determined. Detection limits are 0.005-0.052 mu g L-1,and the recoveries of standard addition are 82%-108%.
Resumo:
In this paper we describe the moleculare and crystal structures of the Na-3[Hg( II )(edta)Cl] . 6H(2)O (edta=ethylenediamine-N,N,N',N'-tetraacetate). The crystal data are as follows: orthorhombic, a=8. 083 (2) Angstrom , b=13. 870(3) Angstrom , c=38. 617(5) Angstrom , v=4329. 4 (13) Angstrom(3) , Z=8, Dc= 1. 798 g . cm(-3), mu=5. 564 mm(-1), P(000)=2280, R=0. 0317 and R-w=0. 0731 for 3883 unique reflections. In complex, the complex anion [Hg ( II ) (edta)Cl](3-) has a seven-coordination structure like a mono-capped trigonal-prism (C-2v-MTP) in which the edta(4-) acts as a hexadentate ligand with four O atoms and two N atoms and a Cl- caps a quadrilateral face as a seventh ligand. It can be known that the Hg2+ which has a d(10) electronic structure can form a high-coordinate compound with a hexadentate ligand (edta) because it has a big ionic radius.
Resumo:
Underpotential deposition(UPD) of copper at polycrystal gold surface under different concentrations has been studied, and its reversibility and stability in high concentration (0.2M CuSO4+0.IM H2SO4) have been demonstrated by cyclic voltermmetry and EQCM. A Valid approach to determine the gold electrode area in presence of adsorbed species has been provided by using Cu UPD method. Further, the growth kinetics of decane thiol on gold has also been investigated based on such a Cu UPD technique.
Resumo:
A new method for immobilization of a chemiluminescent reagent is presented. It is based on immobilizing hematin, a catalyst for luminol reaction, in the bulk of a carbon paste electrode. Bulk-immobilization allows renewal of the surface by simple polishing or cutting to expose anew and fully active surface in the case of fouling or deactivation by other means. By using a hematin-modified carbon paste electrode, the applied potential shifted negatively compared with that of unmodified carbon paste electrode or a glassy carbon electrode. The shift in potential changed the reaction processes and effectively stabilized the chemiluminescent signal during successive measurements. Under this condition, the signal was stable during 3 hours of continuous operation. The log-log plots of the emitted light intensity vs. luminol concentration and hydrogen peroxide concentration were linear over the region 10(-8)-10(-3) mol L-1 with a correlation coefficient of 0.999 and 3.9 x 10(-6)-10(-3) mol L-1 with a correlation coefficient of 0.994, respectively. Application of this method for other chemiluminescent and bioluminescent systems is suggested.
Resumo:
A self-assembled monolayer (SAM) of 3-mercaptopropionic acid (HSCH2CH2COOH) was formed on a gold electrode. The effect of the charge of the end group on the electrochemical response of Fe(CN)(6)(3-) at the SAM modified electrode was studied by using cyclic voltammetry. At high pH, when the -COOH groups are dissociated, Fe(CN)(6)(3-) current is suppressed; as the solution pH is lowered, Fe(CN)(6)(3-) current increases. The electrochemical titration curve was obtained by correlating the currents to the different electrolyte pH values, from which the surface pK(a) was obtained to be 5.2+/-0.1. Furthermore, a calculation equation was presented to simulate the electrochemical titration. As comparison, the surface pK(a) was also measured by contact angle titration as 5.6+/-0.1. The surface pK(a) values determined by the two methods in our work are consistent and accurate.
Resumo:
A novel method for the highly sensitive determination of perchlorate was proposed. It was based on solvent extraction in the presence of Ru(bpy)(3)(2+) followed by Ru(bpy)(3)(2+) electrochemiluminescent determination. A linear calibration was obtained over the range of 0.1 to 10 mu mol l(-1) with a correlation coefficient of 0.998. The detection limit (S/N = 3) was 5.0 x 10(-8) mol l(-1). The relative standard deviation for 10 replicates of 1 mu mol l(-1) perchlorate was 1.6%. Interference studies suggest that this method is selective for the determination of perchlorate. Application of this method to the highly sensitive determination of other anions is suggested. (C) 1999 Elsevier Science S.A. All rights reserved.
Resumo:
In this communication we analyse current versus voltage data obtained using one carrier injection at metal/polymer/metal structures, The used polymer is a soluble blue-emitting alternating block copolymer, Our experimental results demonstrate that the electron current is limited by a large amount of traps with exponential energy distribution in the copolymer. The electron ;mobility of 5.1 x 10(-10) cm(2)/V s is directly determined by space-charge-limited current measurements. The electron mobility is at least three orders of magnitude smaller than that for holes in the copolymer. (C) 1999 Elsevier Science Ltd. All rights reserved.
Resumo:
Petroleum sulfoxide-NH4SCN extraction chromatography was developed for the separation of Y from other rare earth elements. Some chromatographic parameters were chosen and separation factors between Y and other rare earth elements were determined. A column of resin coated with petroleum sulfoxide was used. The Y in the sample was eluted with NH4SCN, then titrated with EDTA. The recovery was 67%-120% and relative standard deviation +/-4.0%-19.4%. This method can be applied to the determination of trace amounts of rare earth impurities in Y2O3 with a purity of 99.999 9%-99. 999 99%.
Resumo:
This article applied [HEH(HEP)] (2-ethyhexyldrogen-2-ethylhexyl phosphonate)extraction chromatography to separate 14 rare earth impurities from ultra-highly pure Er2O3 and Ho2O3, and then the impurities were determined by atomic emission spectrometry. The average percentage recovery for each element is in the range of 70%similar to 140%. The relative standard deviations of the determination are +/-3.3%similar to 2.2%. This method can be applied to the determination of the trace amounts of rare eath impurities in Er2O3 and Ho2O3 with a purity of 99.999 9%-99.999 99%.
Resumo:
A method was developed for the determination of total mercury in biological samples. The effects of aqueous ammonia, ethylenediamine and triethanolamine on Hg signal intensity by inductively coupled plasma mass spectrometry has been evaluated and the possible mechanisms discussed. It has been proved that the signal intensity of Hg significantly increases with adding, in the presence of small amounts of aqueous ammonia, ethylenediamine or triethanolamine. The normalized intensity (the signal intensity ratio with amine and without amine) of Hg increases as the concentration of aqueous ammonia, ethylenediamine or triethanolamine increases, but the degree of enhancement of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The normalized intensity of Hg with aqueous ammonia, ethylenediamine and triethanolamine decreases as the nebulizer flow rate increases, but decreasing degree of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The higher the RF powers the higher the normalized intensity of Hg at the same nebulizer flow rate. The addition of aqueous ammonia, ethylenediamine and triethanolamine into analytical solutions significantly improved the transport efficiency of Hg. The detection limit of Hg is improved about ten times by the addition of ethylenediamine or triethanolamine under the optimum experimental parameters. The method has been used to determine mercury in biological standard reference materials (SRM). The analytical results are very close to the certified values and the determined values for similar samples.
Resumo:
The purity and molecular weight of calmodulin have been determined by means of matrix-assisted laser desorption/ionization time of flight mass spectrometry, and the results have been discussed. The experimental results demonstrate that this method is high sensitive and rapid as compared with other traditional methods.
Resumo:
A method for the determiantion of rare earth elements in biological sampels by inductively coupled plasma mass spectrometry was developed. Oxide ion yield of the rare earth elements (RFE) decreased with the increasing of RF power and the sampling depth, or with the decreasing of carrier gas flow rate. The spectral interference arising from (PrO)-Pr-141-O-16 on Gd-157 must be corrected. if the concentration of Ba was high enough, it was necessary to correct the spectral interference arising from (BO)-B-135-O-16 on Eu-151, and it was not necessary to correct spectral interference arising from (NdO)-Nd-143-O-16 on Tb-159 etc. in the biological samples under the selected operation parameters. In the biological sample, the major matrix elements, such as K, Na and Ca, result in the suppression of REEs signals and the suppression degree of the Ca is grezter than that of the K and Na. The mussel sample was digested by thd dry ashing, wet digestion with HNO3 + H2O2 and HNO3 + HClO4, respectively. The analytical results of REEs were consistent with each other. Detection limits for REEs are 0.001 similar to 0.013 mu g/L. Recoveries of standard addition are 91.7% similar to 125%. REEs in biological samples were determined directly without separation and preconcentration procedure.
Resumo:
A flow injection analysis detection method for glucose is presented which is based on the oxidation of glucose by glucose oxidase followed by chemiluminescent detection of hydrogen peroxide. Both glucose oxidase and hematin, a chemiluminescent reaction catalyst, were bulk-immobilized conveniently by direct mixing with carbon paste, which allows renewal of the electrode surface by simply polishing or cutting to expose a new and fully active surface in the case of fouling. Luminol in reagent solution passed through the flow cell and reacted with hydrogen peroxide produced by the enzyme reactor in the presence of the catalyst to yield light. An applied potential of -0.4 V avoided the electrode fouling effectively. The log-log plot of the emitted light intensity vs glucose concentration was linear over the range of 1-100 mmol L-1 with a correlation coefficient of 0.992. Application of this method to other chemiluminescent and bioluminescent systems is suggested. (C) 1999 Academic Press.
Resumo:
An acid-stable soybean-peroxidase biosensor was devel oped by immobilizing the enzyme in a sol-gel thin film. Methylene blue was used as a mediator because of its high electron-transfer efficiency. The sol-gel thin film and enzyme membrane were characterized by FT-IR, and the effects of pH, operating potential, and temperature were explored for optimum analytical performance by using the amperometric method. The H2O2 sensor exhibited a fast response (5 s), high sensitivity (27.5 mu A/mM), as well as good thermostability and long-term stability. In addition, the performance of the biosensor was investigated using flow-injection analysis (FIA).