974 resultados para electro magnetic noise nuclear detector coaxial cable twisted pair multi wire chamber pixel anode


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above 3 x 10(18) eV, for all zenith angles between 0 degrees and 60 degrees, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we use Nuclear Magnetic Resonance (NMR) to write electronic states of a ferromagnetic system into high-temperature paramagnetic nuclear spins. Through the control of phase and duration of radio frequency pulses, we set the NMR density matrix populations, and apply the technique of quantum state tomography to experimentally obtain the matrix elements of the system, from which we calculate the temperature dependence of magnetization for different magnetic fields. The effects of the variation of temperature and magnetic field over the populations can be mapped in the angles of spin rotations, carried out by the RF pulses. The experimental results are compared to the Brillouin functions of ferromagnetic ordered systems in the mean field approximation for two cases: the mean field is given by (i) B = B(0) + lambda M and (ii) B = B(0) + lambda M + lambda`M(3), where B(0) is the external magnetic field, and lambda, lambda` are mean field parameters. The first case exhibits second order transition, whereas the second case has first order transition with temperature hysteresis. The NMR simulations are in good agreement with the magnetic predictions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To obtain cerebral perfusion territories of the left, the right. and the posterior circulation in humans with high signal-to-noise ratio (SNR) and robust delineation. Materials and Methods: Continuous arterial spin labeling (CASL) was implemented using a dedicated radio frequency (RF) coil. positioned over the neck, to label the major cerebral feeding arteries in humans. Selective labeling was achieved by flow-driven adiabatic fast passage and by tilting the longitudinal labeling gradient about the Y-axis by theta = +/- 60 degrees. Results: Mean cerebral blood flow (CBF) values in gray matter (GM) and white matter (WM) were 74 +/- 13 mL center dot 100 g(-1) center dot minute(-1) and 14 +/- 13 mL center dot 100 g(-1) center dot minute(-1), respectively (N = 14). There were no signal differences between left and right hemispheres when theta = 0 degrees (P > 0.19), indicating efficient labeling of both hemispheres. When theta = +60 degrees, the signal in GM on the left hemisphere, 0.07 +/- 0.06%, was 92% lower than on the right hemisphere. 0.85 +/- 0.30% (P < 1 x 10(-9)). while for theta = -60 degrees, the signal in the right hemisphere. 0.16 +/- 0.13%, was 82% lower than on the contralateral side. 0.89 +/- 0.22% (P < 1 x 10(-10)). Similar attenuations were obtained in WM. Conclusion: Clear delineation of the left and right cerebral perfusion territories was obtained, allowing discrimination of the anterior and posterior circulation in each hemisphere.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polycrystalline La(0.86)Sr(0.14)Mn(1-x)Cu(x)O(3+delta) (x = 0, 0.05, 0.10, 0.15, 0.20) manganites were investigated by means of magnetic measurements and zero-field (139)La and (55)Mn nuclear magnetic resonance (NMR) spectroscopy. Magnetization versus temperature measurements revealed a paramagnetic to ferromagnetic transition in most samples, with lower Curie temperatures and broader transitions for samples with higher Cu contents. The details of the magnetization measurements suggested a phase-separated scenario, with ferromagnetic clusters embedded in an antiferromagnetic matrix, especially for the samples with large Cu contents (x = 0.15 and 0.20). Zero-field (139)La NMR measurements confirmed this finding, since the spectral features remained almost unchanged for all Cu-doped samples, whereas the bulk magnetization was drastically reduced with increasing Cu content. (55)Mn NMR spectra were again typical of ferromagnetic regions, with a broadening of the resonance line caused by the disorder introduced by the Cu doping. The results indicate a coexistence of different magnetic phases in the manganites studied, with the addition of Cu contributing to the weakening of the double-exchange interaction in most parts of the material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we report results from continuous-wave (CW) and pulsed electron paramagnetic resonance (EPR) and proton nuclear magnetic resonance (NMR) studies of the vanadium pentoxide xerogel V2O5:nH(2)O (n approximate to 1.6). The low temperature CW-EPR spectrum shows hyperfine structure due to coupling of unpaired V4+ electron with the vanadium nucleus. The analysis of the spin Hamiltonian parameters suggests that the V4+ ions are located in tetragonally distorted octahedral sites. The transition temperature from the rigid-lattice low-temperature regime to the high temperature liquid-like regime was determined from the analysis of the temperature dependence of the hyperfine splitting and the V4+ motional correlation time. The Electron Spin Echo Envelope Modulation (ESEEM) data shows the signals resulting from the interaction of H-1 nuclei with V4+ ions. The modulation effect was observed only for field values in the center of the EPR absorption spectrum corresponding to the single crystals orientated perpendicular to the magnetic field direction. At least three protons are identified in the xerogel by our magnetic resonance experiments: (I) the OH groups in the equatorial plane, (ii) the bound water molecules in the axial V=O bond and (iii) the free mobile water molecules between the oxide layers. Proton NMR lineshapes and spin-lattice relaxation times were measured in the temperature range between 150 K and 323 K. Our analysis indicates that only a fraction of the xerogel protons contribute to the measured conductivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions. (C) 2010 Elsevier B.V All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In magnetic resonance imaging (MRI), either on human or animal studies, the main requirements for radiofrequency (RF) coils are to produce a homogeneous RF field while used as a transmitter coil and to have the best signal-to-noise ratio (SNR) while used as a receiver. Besides, they need to be easily frequency adjustable and have input impedance matching 50 Omega to several different load conditions. New theoretical and practical concepts are presented here for considerable enhancing of RF coil homogeneity for MRI experiments on small animals. To optimize field homogeneity, we have performed simulations using Blot and Savart law varying the coil`s window angle, achieving the optimum one. However, when the coil`s dimensions are the same order of the wave length and according to transmission line theory, differences in electrical length and effects of mutual inductances between adjacent strip conductors decrease both field homogeneity and SNR. The problematic interactions between strip conductors by means of mutual inductance were eliminated by inserting crossings at half electrical length, avoiding distortion on current density, thus eliminating sources of field inhomogeneity. Experimental results show that measured field maps and simulations are in good agreement. The new coil design, dubbed double-crossed saddle described here have field homogeneity and SNR superior than the linearly driven 8-rung birdcage coil. One of our major findings was that the effects of mutual inductance are more significant than differences in electrical length for this frequency and coil dimensions. In vitro images of a primate Cebus paela brain were acquired, confirming double-crossed saddle superiority. (C) 2010 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 37B: 193-201, 2010

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we applied a quantum circuit treatment to describe the nuclear spin relaxation. From the Redfield theory, we obtain a description of the quadrupolar relaxation as a computational process in a spin 3/2 system, through a model in which the environment is comprised by five qubits and three different quantum noise channels. The interaction between the environment and the spin 3/2 nuclei is described by a quantum circuit fully compatible with the Redfield theory of relaxation. Theoretical predictions are compared to experimental data, a short review of quantum channels and relaxation in NMR qubits is also present.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic fabric and rock magnetism studies were performed on apparently isotropic granite facies from the main intrusion of the Lavras do Sul Intrusive Complex pluton (LSIC, Rio Grande do Sul, South Brazil). This intrusion is roughly circular (similar to 12 x 13.5 km), composed of alkali-calcic and alkaline granitoids, with the latter occupying the margin of the pluton. Magnetic fabrics were determined by applying both anisotropy of low-field magnetic susceptibility (AMS) and anisotropy of anhysteretic remanent magnetization (AARM). The two fabrics are coaxial. The parallelism between AMS and AARM tensors excludes the presence of a single domain (SD) effect on the AMS fabric of the granites. Several rock-magnetism experiments performed in one specimen from each sampled site show that for all sites the magnetic susceptibility is dominantly carried by ferromagnetic minerals, while mainly magnetite carries the magnetic fabrics. Lineations and foliations in the granite facies were successful determined by applying magnetic methods. Magnetic lineations are gently plunging and roughly parallel to the boundaries of the pluton facies, except at the few sites in the central facies which have a radial orientation pattern. In contrast, the magnetic foliations tend to follow the contacts between the different granite facies. They are gently outerward-dipping inside the pluton, and become either steeply southwesterly dipping or vertical towards its margin. The lack of solid-state and subsolidus deformations at outcrop scale and in thin sections precludes deformation after full crystallization of the pluton. This evidence allows us to interpret the observed magnetic fabrics as primary in origin (magmatic) acquired when the rocks were solidified as a result of processes reflecting magma flow. The foliation pattern displays a dome-shaped form for the main LSIC-pluton. However, the alkaline granites which outcrop in the southern part of the studied area have an inward-dipping foliation, and the steeply plunging magnetic lineation suggests that this area could be part of a feeder zone. The magma ascent probably occurred due to ring-diking. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An all-in-one version of a capacitively coupled contactless conductivity detector is introduced. The absence of moving parts (potentiometers and connectors) makes it compact (6.5 cm(3)) and robust. A local oscillator, working at 1.1 MHz, was optimized to use capillaries of id from 20 to 100 lam. Low noise circuitry and a high-resolution analog-to-digital converter (ADC) (21 bits effective) grant good sensitivities for capillaries and background electrolytes currently used in capillary electrophoresis. The fixed frequency and amplitude of the signal generator is a drawback that is compensated by the steady calibration curves for conductivity. Another advantage is the possibility of determining the inner diameter of a capillary by reading the ADC when air and subsequently water flow through the capillary. The difference of ADC reading may be converted into the inner diameter by a calibration curve. This feature is granted by the 21-bit ADC, which eliminates the necessity of baseline compensation by hardware. In a typical application, the limits of detection based on the 3 sigma criterion (without baseline filtering) were 0.6, 0.4, 0.3, 0.5, 0.6, and 0.8 mu mol/L for K(+), Ba(2+), Ca(2+), Na(+), Mg(2+), and Li(+), respectively, which is comparable to other high-quality implementations of a capacitively coupled contactless conductivity detector.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we show that the steady-state free precession sequence can be used to acquire (13)C high-resolution nuclear magnetic resonance spectra and applied to qualitative analysis. The analysis of brucine sample using this sequence with 60 degrees flip angle and time interval between pulses equal to 300 ms (acquisition time, 299.7 ms; recycle delay, 300 ms) resulted in spectrum with twofold enhancement in signal-to-noise ratio, when compared to standard (13)C sequence. This gain was better when a much shorter time interval between pulses (100 ms) was applied. The result obtained was more than fivefold enhancement in signal-to-noise ratio, equivalent to more than 20-fold reduction in total data recording time. However, this short time interval between pulses produces a spectrum with severe phase and truncation anomalies. We demonstrated that these anomalies can be minimized by applying an appropriate apodization function and plotting the spectrum in the magnitude mode.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper was to study patients with congenital and acquired hemiparesis, their clinical aspects, the presence or not of epileptic seizures, and electroencephalographic (EEG) and Magnetic Resonance Imaging (MRI) findings. We analyzed the interrelation between etiology, the presence and seriousness of epileptic seizures (ES) and the possible causes of refractoriness. This is a prospective study using the clinical diagnosis of a child neurologist, who attested to the presence of unilateral motor lesions. We compared the electroencephalographic findings in patients with or without epileptic seizures, and investigated if among the former, these seizures were controlled or not, their likely etiology and risks of refractoriness. EEG background activity on the lesion and contralateral side was analyzed, in addition to the presence of concomitant epileptiform activity. Encephalon MRIs of all the patients were studied to correlate etiology and the control or not of epileptic seizures. The disorganization of bilateral EEG activity correlated with the difficult-to-control epileptic seizures. Suitably organized background activity contralateral to the lesion is a good prognosis in relation to epileptic seizures. Focal epileptogenic activity does not necessarily predispose to epileptic manifestation. The MRI is more important in determining etiology than in prognosing epileptic seizures. This study used a multidisciplinary approach involving child neurologists, a physical therapist and a neuroradiologist. This meets the criteria of multidisciplinarity of the Postgraduate Program in Health Sciences

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objetivou-se determinar o potencial do uso da tomografia de ressonância magnética, como método não-destrutivo, para avaliar os efeitos das injúrias mecânicas em goiabas. Foram utilizados frutos no estádio de maturação de vez das cultivares Paluma e Pedro Sato. Na injúria por impacto, os frutos foram deixados cair, em queda livre, de uma altura de 1,20 m, sofrendo dois impactos, em lados opostos de sua porção equatorial. Na injúria por compressão, os frutos foram submetidos a um peso de 29,4 N, por 15 minutos. Para a injúria por corte, foram efetuados dois cortes, no sentido longitudinal dos frutos, de exatamente 30 mm de comprimento por 2 mm de profundidade. Os frutos injuriados foram armazenados sob condições de ambiente (22 ± 2 °C e 40 %UR). Foram realizadas análises com tomógrafo de ressonância magnética Varian Inova de 2 Tesla. As imagens foram obtidas a partir da detecção dos prótons de hidrogênio (¹H). Para cada fruto, foram obtidos tomogramas simétricos a partir do centro do fruto. A tomografia de ressonância magnética nuclear mostrou-se uma ferramenta eficaz na detecção de injúrias internas de frutos. O estresse físico causado pelo impacto produziu um colapso interno nos lóculos desses frutos (internal bruising), levando à perda da integridade celular e a conseqüente liquefação dos tecidos placentários. A cultivar Pedro Sato mostrou uma suscetibilidade maior à injúria por impacto que a 'Paluma'. A injúria por compressão tornou-se mais evidente no pericarpo externo do fruto, de ambas as cultivares. A injúria por corte levou a lignificação dos tecidos no local injuriado e deformações superficiais devido à perda acentuada de matéria fresca no local da lesão, evidentes no sexto dia de avaliação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate some proposals to solve the electric charge quantization puzzle that simultaneously explain the recent measured deviation on the muon anomalous magnetic moment. For this we assess extensions of the electro-weak standard model spanning modifications on the scalar sector only. It is interesting to verify that one can have modest extensions which easily account for the solution for both problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO. (c) 2006 Elsevier B.V. All rights reserved.