892 resultados para cooling curve


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Line of Investigation that in the department of “Technical Drawing” in the School of Agriculture Engineering of Madrid, we carry out on the study of The Technical Curves and his singularities, we demonstrate an interesting property of the Logarithmic Spiral. The demonstrated property consists of which the logarithmic spiral is a autoisoptic curve, that is to say that if from a point P anyone of the spiral tangent straight lines draw up to the previous arc, these form a constant angle α. This demonstration is novel and in addition we get to contribute a method to calculate the angle α given the equation of the spiral.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of cooling rate on the microstructure of MAR-M247 Ni-based superalloy was investigated via physical simulation of the casting process. Solidification experiments with cooling rates in the range of 0.25–10 K/s showed smooth temperature profiles with measured cooling rates matching the set values. The MAR-M247 showed cellular (0.25 K/s) and dendritic (1, 5 and 10 K/s) microstructures. Microconstituents also varied with cooling rates: γ/γ′ matrix with carbides and γ/γ′ eutectic at 0.25 K/s, γ/γ′ matrix with carbides at 1 K/s, and γ/γ′ matrix with carbides and γ/MC eutectic at 5 and 10 K/s. Moreover, the secondary dendritic arm spacing decreased and the hardness increased with the increase in the cooling rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudio de la cinética de la crioconservación de tejidos vegetales

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solutions studied were Plant Vitrification Solutions 1, 2 and 3: (PVS1: Uragami et al. 1989, Plant Cell Rep. 8, 418; PVS2: Sakai et al. 1990, Plant Cell Rep. 9, 30; PVS3: Nishizawa et al. 1993, Plant Sci. 91, 67). Cooling was performed using the calorimeter control (5, 10 and 20°C min-1), or for higher rates, by quenching the closed pan with PVS in LN, either naked (faster - 5580°C min-1) or introduced in cryovials (reduced rate 360°C min-1). Quenched pans were then transferred to the sample chamber, pre-cooled to -196°C. Glass transition temperature was observed by DSC with a TA 2920 instrument, upon warming pans with solution samples from -145°C to room temperature, at standard warming rate10°C min-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar thermal power plants are usually installed in locations with high yearly average solar radiation, often deserts. In such conditions, cooling water required for thermodynamic cycles is rarely available. Moreover, when solar radiation is high, ambient temperature is very high as well; this leads to excessive condensation temperature, especially when air-condensers are used, and decreases the plant efficiency. However, temperature variation in deserts is often very high, which drives to relatively low temperatures during the night. This fact can be exploited with the use of a closed cooling system, so that the coolant (water) is chilled during the night and store. Chilled water is then used during peak temperature hours to cool the condenser (dry cooling), thus enhancing power output and efficiency. The present work analyzes the performance improvement achieved by night thermal cool storage, compared to its equivalent air cooled power plant. Dry cooling is proved to be energy-effective for moderately high day–night temperature differences (20 °C), often found in desert locations. The storage volume requirement for different power plant efficiencies has also been studied, resulting on an asymptotic tendency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electron-retarding range of the current-voltage characteristic of a flat Langmuir probe perpendicular to a strong magnetic field in a fully ionized plasma is analysed allowing for anomalous (Bohm) cross-field transport and temperature changes in the collection process. With probe size and ion thermal gyroradius comparable, and smaller than the electron mean free path, there is an outer quasineutral region with ion viscosity determinant in allowing nonambipolar parallel and cross flow. A potential overshoot lying either at the base or inside the quasineutral region both makes ions follow Boltzmann's law at negative bias and extends the electron-retarding range to probe bias e(j)p ~ +2Too. Electron heating and cooling occur roughly at positive and negative bias, with a re-minimum around efa ~ - 2 7 ^ ; far from the probe heat conduction cools and heats electrons at and radially away from the probe axis, respectively. The potential overshoot with no thermal effects would reduce the electron current Ie, making the In Ie versus 4>p graph downwards-concave,but cooling further reduces Ie substantially, and may tilt the slope upwards past the temperature minimum. The domain of strict validity of our analysis is narrow in case of low ion mass (deuterium), breaking down with the ion Boltzmann law.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we present an analysis of the influence of the thermodynamic regime on the monochromatic emissivity, the radiative power loss and the radiative cooling rate for optically thin carbon plasmas over a wide range of electron temperature and density assuming steady state situations. Furthermore, we propose analytical expressions depending on the electron density and temperature for the average ionization and cooling rate based on polynomial fittings which are valid for the whole range of plasma conditions considered in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the measurement of the I-V curve of an 800 kW PV generator by means of an own-made capacitive load. Along the lines of some previous works, it is shown that an I-V curve analysis can also be applied to big PV generators and that, when measuring the operating conditions with reference modules and taking some precautions (especially regarding the operating cell temperature), it is still a useful tool for characterizing them and therefore can be incorporated into maintenance procedures. As far as we know, this is the largest I-V curve measured so far.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper shows the Gini Coefficient, the dissimilarity Index and the Lorenz Curve for the Spanish Port System by type of goods from 1960 to the year 2010 for business units: Total traffic, Liquid bulk cargo, Solid bulk cargo, General Merchandise and Container (TEUs) with the aim of carcaterizar the Spanish port systems in these periods and propose future strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the measurement of the I-V curve of a 500-kW PV generator by means of an own-made capacitive load. It is shown that I-V curve analysis can also be applied to big PV generators and that when measuring the operation conditions with reference modules and taking some precautions (especially regarding the operation cell temperature), it is still a useful tool for characterizing them and therefore can be incorporated into maintenance procedures. As far as we know, this is the largest I-V curve measured so far.