Invariance of the Glass Transition Temperature of Plant Vitrification Solutions with Cooling Rate


Autoria(s): Schneider Teixeira, Aline; Faltus, Milos; Zamecnik, Jiri; Kotková, Renata; González Benito, Elena; Molina García, Antonio Diego
Data(s)

01/12/2012

Resumo

The solutions studied were Plant Vitrification Solutions 1, 2 and 3: (PVS1: Uragami et al. 1989, Plant Cell Rep. 8, 418; PVS2: Sakai et al. 1990, Plant Cell Rep. 9, 30; PVS3: Nishizawa et al. 1993, Plant Sci. 91, 67). Cooling was performed using the calorimeter control (5, 10 and 20°C min-1), or for higher rates, by quenching the closed pan with PVS in LN, either naked (faster - 5580°C min-1) or introduced in cryovials (reduced rate 360°C min-1). Quenched pans were then transferred to the sample chamber, pre-cooled to -196°C. Glass transition temperature was observed by DSC with a TA 2920 instrument, upon warming pans with solution samples from -145°C to room temperature, at standard warming rate10°C min-1.

Formato

application/pdf

Identificador

http://oa.upm.es/16136/

Idioma(s)

eng

Publicador

E.U.I.T. Agrícola (UPM)

Relação

http://oa.upm.es/16136/1/INVE_MEM_2012_96177.pdf

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

Cryobiology, ISSN 0011-2240, 2012-12, Vol. 65, No. 3

Palavras-Chave #Agricultura
Tipo

info:eu-repo/semantics/article

Artículo

PeerReviewed