984 resultados para application times


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Native agars from Gracilaria vermiculophylla produced in sustainable aquaculture systems (IMTA) were extracted under conventional (TWE) and microwave (MAE) heating. The optimal extracts from both processes were compared in terms of their properties. The agars’ structure was further investigated through Fourier transform infrared and NMR spectroscopy. Both samples showed a regular structure with an identical backbone, β-D-galactose (G) and 3,6-anhydro-α-L-galactose (LA) units; a considerable degree of methylation was found at C6 of the G units and, to a lesser extent, at C2 of the LA residues. The methylation degree in the G units was lower for MAEopt agar; the sulfate content was also reduced. MAE led to higher agar recoveries with drastic extraction time and solvent volume reductions. Two times lower values of [η] and Mv obtained for the MAEopt sample indicate substantial depolymerization of the polysaccharide backbone; this was reflected in its gelling properties; yet it was clearly appropriate for commercial application in soft-texture food products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: A realização de broncofibroscopia (BF) a doentes com insuficiência Respiratória grave tem riscos e muitas vezes está contra-indicada. A aplicação de ventilação mecânica não invasiva (VMNI) para assistir a ventilação espontânea durante a BF pode ser constituir uma boa alternativa . Objectivo: Comparar a utilização de VMNI e do CPAP Boussignac (CB), durante a BF, em doentes hipoxémicos e/ou hipercápnicos. Materiais e Metodos: 9 pacientes (1feminino) com hipoxemia definida por PaO2/FiO2<200 com necessidade de (BF) foram elegíveis para o estudo. Cinco indivíduos foram randomizados para o grupo VMNI (G1) e 4 para o grupo CB (G2). Resultados: A pressão parcial arterial de oxigénio (PaO2) melhorou no grupo total: 65,9 (21,9) vs de 94,4 (75,9) pós BF, p=0,03, assim como a relação PaO2/FiO2: 131,7 (129,0) e 150,7 (161, 3), pós BF, p=0,04. A saturação periférica de O2 média durante a BF não foi significativamente diferente comparando os dois grupos: 96,1 (6,9) no G1 vs 97,3 (0,3) no G2, (p=0,62). No G1, 1 paciente foi intubado. Conclusão: Estes resultados sugerem que a pressão positiva tem um papel importante como técnica coadjuvante da BF em pacientes hipoxémicos graves (PaO2/FiO2<200). Neste estudo preliminar nenhuma vantagem da VMNI vs CB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3rd SMTDA Conference Proceedings, 11-14 June 2014, Lisbon Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On this work we suggest a teaching solution that can be implemented in Azores, an archipelago of nine islands of Portugal, based in already known system of e-learning, with a twist based on the flipped method. Structured in a cooperative way, the organization of the system allows to isolated groups of people to have access to a certain level of teaching, if they cannot have the possibility to have physical presence in school due to problems emerging from territory discontinuity. Our suggestion can be elaborate in a model that can be adapted to any level of education, and can be adapted also in cases that a cut of budget exists. We suggest the name of fb-learning: Flipped Broadcast Learning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A empresa Petibol, S.A. – Embalagens de plástico centra-se na produção de embalagens de plástico a partir da matéria-prima Poliestireno Expandido (EPS) e Polipropileno Expandido (EPP). A empresa possui uma preocupação ao nível da qualidade da água e do aproveitamento energético, tendo desta forma surgido a realização do estudo na unidade industrial, com o objectivo de anular e/ou diminuir as possíveis lacunas existentes na unidade industrial. Numa primeira etapa foi realizada uma caracterização global à qualidade da água e à empresa, actualizando-se os esquemas já existentes, contabilizando-se os custos actuais relativamente aos processos no circuito da água (arrefecimento, aquecimento e pressurização), e por fim, efectuou-se um levantamento in loco do circuito de água, relativamente à pressão, temperatura e caudal. Numa fase posterior, foram propostos equipamentos e processos, tendo em vista a colmatação dos problemas identificados, realizando-se um subsequente estudo relativamente aos custos inerentes a esses novos processos. A caracterização à água foi avaliada em diferentes pontos do circuito industrial, tendo-se determinado na Sala de Bombagem que o filtro de areia não possuía as dimensões mais apropriadas, existindo também um problema a nível mecânico associado ao processo de contra-lavagem. Tais factos podem ser a causa da ocorrência de um aumento do teor de sólidos após a passagem na camada filtrante. Relativamente ao amaciador, este deveria amaciar de forma completa a água para alimentação à caldeira, embora se tenha registado à saída do amaciador uma dureza de 21,3 mg/L, denunciando problemas na troca iónica. No que toca à água de alimentação à caldeira, verifica-se a existência de parâmetros que não se encontram de acordo com os critérios enunciados para uma óptima qualidade, sendo eles o pH (10,14), condutividade (363 μS/cm), teor de ferro (1,21 mg/L) e a dureza (16 mg/L). De salientar que somente o teor de cobre, que se encontra em quantidades vestigiais, apresenta-se de acordo com os valores impostos. No que respeita à água da caldeira, esta apresenta parâmetros incompatíveis com os recomendados, sendo eles a condutividade (7350 μS/cm), teor de sólidos dissolvidos (5248 mg/L) e alcalinidade total (780 mg/L). De referir que o valor de pH (11,8) não se encontra de acordo com a aplicação do tratamento “fosfato-pH coordenado”. Em relação aos parâmetros com valores que se encontram dentro dos limites, estes correspondem à dureza (0 mg/L), ao teor de fosfatos (45 mg/L) e teor de sílica (0 mg/L). A água do circuito de arrefecimento foi sujeita a uma análise microbiológica, que corroborou a presença de um biofilme. Um dos problemas enunciados pela empresa, prendia-se com a impossibilidade de descarga, no colector municipal, dos condensados dos compressores, visto apresentarem uma quantidade de óleo de cerca de 43,3 mg/L, equivalente a quatro vezes o valor limite de emissão, de acordo com a legislação municipal. Por fim, o efluente de descarga industrial apresenta um valor de pH (10,3) acima do intervalo permitido por lei (6,0 – 9,0), sendo que a corrente que mais contribui para este acréscimo de pH corresponde à corrente proveniente da água de purga, visto esta apresentar um valor de pH de 12,22. De maneira a contornar os parâmetros enunciados, é proposto a substituição do filtro de areia da Sala de Bombagem, assim como a inserção de um conjunto de medidas de remoção de ferro e desinfecção, sendo a conjugação de arejamento, coagulação, filtração e desinfecção, por parte do hipoclorito, a proposta apresentada. Aos condensados dos compressores é apresentado um sistema de separação, que possibilita a remoção do óleo da água, e uma consequente descarga da mesma. Actualmente, não existe qualquer filtro de areia no circuito de arrefecimento da água, sendo proposto assim esse equipamento, de forma a minorar o desenvolvimento da população microbiana, bem como a permitir uma maior eficiência na transferência de calor na torre de arrefecimento. Relativamente à descarga industrial, é recomendável a colocação de um sistema de regularização automática de pH. A inserção de uma válvula de três vias permite um aproveitamento energético e de água, a partir da confluência da água oriunda dos furos com a água do tanque de água fria, sendo posteriormente alimentada à central de vácuo. No estudo da recuperação energética, um outro equipamento avaliado correspondeu à serpentina, no entanto, verificou-se que a poupança no consumo de gás natural era de apenas 0,005%, o que não se mostrou uma proposta viável. O orçamento de todos os equipamentos é de 11.720,76 €, possibilitando não só um melhor funcionamento industrial, como um menor impacto a nível ambiental. Os custos futuros de funcionamento aumentam em 3,36%, tendo a pressurização um aumento do seu custo em 3,4% em relação ao custo actual, verificando-se um custo anual de 10.781,21€, em relação aos processos de arejamento, coagulação e desinfecção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tourism contributes to the development of many regions. Different factors affect the movement of tourists within a destination. Those factors are related to the tourist characteristics, like the time budgets, preferences or destination knowledge, and to the destination features, like the attraction characteristics or accessibility level. Tourist decisions aren’t always done in a rational way. Emotions add further complexity to the human decision process. The use of footpaths can play an important role in the satisfaction of tourists, helping them discover the territory and giving them access to different types of attractions. The existence of a mathematical model that integrates the main factors related to the movement of independent tourists within a destination, in a dynamic way, will make possible the creation of an adaptable software tool. This tool will meet the specific needs of tourists, allowing the use of the network in an optimal way by the different tourist profiles, and the needs of the regional government and business, permitting better decisions and the offer of relevant tourism products. This article identifies the main tourists’ mobility criteria in the São Miguel island territory, Azores, Portugal, recognizes the necessary modelling process and identifies the basis for the construction of the mathematical model that explains the movement of tourists within the destination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A metodologia Kaizen, originária do Japão, tem como significado “melhorar continuamente” e ao longo da sua existência tem sido aplicada com grande sucesso em várias empresas, existindo três aspectos fundamentais para sua aplicabilidade: um melhor serviço ao cliente, uma melhor qualidade dos seus produtos e na redução dos custos pela via da eliminação dos desperdícios. Neste sentido, a dissertação propõe a aplicação da metodologia e ferramentas Kaizen ao contexto real da empresa Polisport. Esta empresa integra o Grupo Polisport e tem como seu núcleo principal a obtenção de materiais, montagem e comercialização de artigos finais para bicicleta, moto e automóvel. Neste contexto, o presente trabalho reflecte o estudo de técnicas de criação de valor interno, tendo em vista o aumento da produtividade dos seus processos produtivos. É realçado ainda a complementaridade da metodologia Kaizen com o estudo dos tempos e métodos, distinguindo o balanceamento e a ergonomia de postos de trabalho directamente relacionado com a eficiência do operário.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho propus-me realizar um Sistema de Aquisição de Dados em Tempo Real via Porta Paralela. Para atingir com sucesso este objectivo, foi realizado um levantamento bibliográfico sobre sistemas operativos de tempo real, salientando e exemplificando quais foram marcos mais importantes ao longo da sua evolução. Este levantamento permitiu perceber o porquê da proliferação destes sistemas face aos custos que envolvem, em função da sua aplicação, bem como as dificuldades, científicas e tecnológicas, que os investigadores foram tendo, e que foram ultrapassando com sucesso. Para que Linux se comporte como um sistema de tempo real, é necessário configura-lo e adicionar um patch, como por exemplo o RTAI ou ADEOS. Como existem vários tipos de soluções que permitem aplicar as características inerentes aos sistemas de tempo real ao Linux, foi realizado um estudo, acompanhado de exemplos, sobre o tipo de arquitecturas de kernel mais utilizadas para o fazer. Nos sistemas operativos de tempo real existem determinados serviços, funcionalidades e restrições que os distinguem dos sistemas operativos de uso comum. Tendo em conta o objectivo do trabalho, e apoiado em exemplos, fizemos um pequeno estudo onde descrevemos, entre outros, o funcionamento escalonador, e os conceitos de latência e tempo de resposta. Mostramos que há apenas dois tipos de sistemas de tempo real o ‘hard’ que tem restrições temporais rígidas e o ‘soft’ que engloba as restrições temporais firmes e suaves. As tarefas foram classificadas em função dos tipos de eventos que as despoletam, e evidenciando as suas principais características. O sistema de tempo real eleito para criar o sistema de aquisição de dados via porta paralela foi o RTAI/Linux. Para melhor percebermos o seu comportamento, estudamos os serviços e funções do RTAI. Foi dada especial atenção, aos serviços de comunicação entre tarefas e processos (memória partilhada e FIFOs), aos serviços de escalonamento (tipos de escalonadores e tarefas) e atendimento de interrupções (serviço de rotina de interrupção - ISR). O estudo destes serviços levou às opções tomadas quanto ao método de comunicação entre tarefas e serviços, bem como ao tipo de tarefa a utilizar (esporádica ou periódica). Como neste trabalho, o meio físico de comunicação entre o meio ambiente externo e o hardware utilizado é a porta paralela, também tivemos necessidade de perceber como funciona este interface. Nomeadamente os registos de configuração da porta paralela. Assim, foi possível configura-lo ao nível de hardware (BIOS) e software (módulo do kernel) atendendo aos objectivos do presente trabalho, e optimizando a utilização da porta paralela, nomeadamente, aumentando o número de bits disponíveis para a leitura de dados. No desenvolvimento da tarefa de hard real-time, foram tidas em atenção as várias considerações atrás referenciadas. Foi desenvolvida uma tarefa do tipo esporádica, pois era pretendido, ler dados pela porta paralela apenas quando houvesse necessidade (interrupção), ou seja, quando houvesse dados disponíveis para ler. Desenvolvemos também uma aplicação para permitir visualizar os dados recolhidos via porta paralela. A comunicação entre a tarefa e a aplicação é assegurada através de memória partilhada, pois garantindo a consistência de dados, a comunicação entre processos do Linux e as tarefas de tempo real (RTAI) que correm ao nível do kernel torna-se muito simples. Para puder avaliar o desempenho do sistema desenvolvido, foi criada uma tarefa de soft real-time cujos tempos de resposta foram comparados com os da tarefa de hard real-time. As respostas temporais obtidas através do analisador lógico em conjunto com gráficos elaborados a partir destes dados, mostram e comprovam, os benefícios do sistema de aquisição de dados em tempo real via porta paralela, usando uma tarefa de hard real-time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho presente nesta dissertação incidiu sobre a aplicação das metodologias Lean no âmbito da manutenção de uma empresa metalomecânica de produção de Moldes – Simoldes Aços. No atual enquadramento, com os mercados nacionais e internacionais debaixo de feroz competição, as empresas são obrigadas a estudar métodos e técnicas que permitam eliminar desperdícios, reduzir custos e tempos de produção, ao mesmo tempo que são exigidos maiores níveis de qualidade dos produtos fabricados com vista ao aumento da competitividade. Sendo a Manutenção uma área funcional com um impacto elevado no desempenho da produção, é percebido que o desempenho desta, tem influência direta no comportamento do fluxo produtivo e nos respetivos níveis de eficácia e eficiência. No decorrer do trabalho desta dissertação de mestrado foi realizada uma análise abrangente do estado atual do sector de atividade de manutenção na empresa SIMOLDES SA, o que permitiu identificar as áreas e os pontos a intervir e desenhar as soluções de melhoria na atividade de manutenção. Na fase concludente do trabalho foram implementadas algumas dessas propostas de melhoria, ao passo que outras ficaram agendadas para futura implementação. Na base do trabalho desenvolvido esteve a metodologia Lean, que apresenta um papel relevante na implementação de uma abordagem integrada da função manutenção na manutenção dos objetivos da produção. O presente projeto baseou a sua estratégia de implementação na aplicação da ferramenta do 5S’ em paralelo com o TPM (Total Productive Maintenance). Ambas as ferramentas visam a redução de desperdícios e o aumento da fiabilidade dos processos, pelo aumento da disponibilidade dos equipamentos, da melhoria do desempenho dos processos e da plena integração de todos os colaboradores no processo de fabrico. Com a implementação das melhorias propostas, foram observados melhorias significativas no fluxo das atividades da manutenção, assim como uma maior visibilidade das mesmas em todo o processo produtivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nickel-copper metallic foams were electrodeposited from an acidic electrolyte, using hydrogen bubble evolution as a dynamic template. Their morphology and chemical composition was studied by scanning electron microscopy and related to the deposition parameters (applied current density and deposition time). For high currents densities (above 1 A cm(-2)) the nickel-copper deposits have a three-dimensional foam-like morphology with randomly distributed nearly-circular pores whose walls present an open dendritic structure. The nickel-copper foams are crystalline and composed of pure nickel and a copper-rich phase containing nickel in solid solution. The electrochemical behaviour of the material was studied by cyclic voltammetry and chronopotentiometry (charge-discharge curves) aiming at its application as a positive electrode for supercapacitors. Cyclic voltammograms showed that the Ni-Cu foams have a pseudocapacitive behaviour. The specific capacitance was calculated from charge-discharge data and the best value (105 F g(-1) at 1 mA cm(-2)) was obtained for nickel-copper foams deposited at 1.8 A cm(-2) for 180 s. Cycling stability of these foams was also assessed and they present a 90 % capacitance retention after 10,000 cycles at 10 mA cm(-2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.