976 resultados para Pressure Sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Room-temperature sensing characteristics for H-2, ethanol, NH3, H2S and water have been investigated with thick-film sensors based on GaN nanoparticles, prepared by a simple chemical route. In general, GaN nanoparticles exhibit satisfactory sensor properties for these gases and vapors even at room temperature. The sensitivity for ethanol is found to be highest, the sensitivity and recovery times being smallest. Gas sensor properties of GaN seem to be related to intrinsic defects, which act as sorption sites for the gas molecules. (c) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pressure and temperature dependence of 35Cl nuclear quadrupole resonance (NQR) has been investigated in NaClO3 and Ba(ClO3)2·H2O. NQR frequencies are measured in the temperature range 77–300 K and up to 5 kbar pressure. The torsional frequency of the ClO3 pyramid and its variation with both pressure and temperature are evaluated from the NQR frequencies under the harmonic approximation. In general, the pressure effect on the internal motions is found to be less in Ba (ClO3)2·H2O compared to NaClO3. When the samples are cooled to 77 K the pressure coeffecient of NQR frequency becomes nearly zero in sodium chlorate, whereas it retains a value of 6 kHz kbar−1 in barium chlorate. This behaviour follows from the fact that at 77K, the torsional frequency in NaClO3 is unaffected by the application of pressure while it increases at the rate 12 cm−1 kbar−1 in Ba(ClO3)2·H2O.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypertension is one of the major risk factors for cardiovascular morbidity. The advantages of antihypertensive therapy have been clearly demonstrated, but only about 30% of hypertensive patients have their blood pressure (BP) controlled by such treatment. One of the reasons for this poor BP control may lie in the difficulty in predicting BP response to antihypertensive treatment. The average BP reduction achieved is similar for each drug in the main classes of antihypertensive agents, but there is a marked individual variation in BP responses to any given drug. The purpose of the present study was to examine BP response to four different antihypertensive monotherapies with regard to demographic characteristics, laboratory test results and common genetic polymorphisms. The subjects of the present study are participants in the pharmacogenetic GENRES Study. A total of 208 subjects completed the whole study protocol including four drug treatment periods of four weeks, separated by four-week placebo periods. The study drugs were amlodipine, bisoprolol, hydrochlorothiazide and losartan. Both office (OBP) and 24-hour ambulatory blood pressure (ABP) measurements were carried out. BP response to study drugs were related to basic clinical characteristics, pretreatment laboratory test results and common polymorphisms in genes coding for components of the renin-angiotensin system, alpha-adducin (ADD1), beta1-adrenergic receptor (ADRB1) and beta2-adrenergic receptor (ADRB2). Age was positively correlated with BP responses to amlodipine and with OBP and systolic ABP responses to hydrochlorothiazide, while body mass index was negatively correlated with ABP responses to amlodipine. Of the laboratory test results, plasma renin activity (PRA) correlated positively with BP responses to losartan, with ABP responses to bisoprolol, and negatively with ABP responses to hydrochlorothiazide. Uniquely to this study, it was found that serum total calcium level was negatively correlated with BP responses to amlodipine, whilst serum total cholesterol level was negatively correlated with ABP responses to amlodipine. There were no significant associations of angiotensin II type I receptor 1166A/C, angiotensin converting enzyme I/D, angiotensinogen Met235Thr, ADD1 Gly460Trp, ADRB1 Ser49Gly and Gly389Arg and ADRB2 Arg16Gly and Gln27Glu polymorphisms with BP responses to the study drugs. In conclusion, this study confirmed the relationship between pretreatment PRA levels and response to three classes of antihypertensive drugs. This study is the first to note a significant inverse relation between serum calcium level and responsiveness to a calcium channel blocker. However, this study could not replicate the observations that common polymorphisms in angiotensin II type I receptor, angiotensin converting enzyme, angiotensinogen, ADD1, ADRB1, or ADRB2 genes can predict BP response to antihypertensive drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

V2O5 supported on ZrO2 is found to be an excellent sensor for n-propane-butane mixtures at 625 K; in-situ X-ray diffraction studies show that V2O5 is reduced to VO2 with a metastable monoclinic structure on contact with the hydrocarbons and is oxidised back to the parent oxide on exposure to air.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The equilibrium pressure of calcium corresponding to the reduction reaction 6CaO (s) + 2Al (l) half-arrow-right-over-half-arrow-left 3CaO.Al2O3 (s) + 3Ca (g) has been measured by Knudsen effusion - mass loss analysis in the temperature range 1190 - 1500 K. The measured vapour pressure can be expressed as a function of temperature by the relation: log p(Ca) (Pa) = -10,670/T + 9.267 The calcium generated is partially absorbed by aluminium to form an alloy. The equilibrium composition of the alloy at 1373 K was found to be 22 mol% Ca - 78 mol% Al. The measured vapour pressure is in good agreement with that computed from thermodynamic data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pressure dependence of critical parameters xc, Tc, and β have been analysed in four systems namely cyclohexane + acetic anhydride, n-heptane + acetic anhydride, methanol + n-heptane, and carbon disulphide + acetonitrile. The separation temperature was found to increase linearly with pressure the value of dTc/dP being 28 mK, 11 mK, 22 mK, and 25 mK respectively. These are in fair agreement with earlier measurements available for two systems. For the methanol + n-heptane system dTc/dP is apparently not consistent with the value predicted from the specific heat and thermal expansion data.Die Druckabhängigkeit der kritischen Parameter xc, Tc und β ist in den vier Systemen Cyclohexan + Essigsäureanhydrid, n-Heptan + Essigsäureanhydrid, Methanol + n-Heptan und Schwefelkohlenstoff + Acetonitril analysiert worden. Es wurde gefunden, daß die kritische Temperatur linear mit dem Druck ansteigt. Die Werte für dTc/dP betragen 28 mK, 11 mK, 22 mK und 25 mK. Sie sind in guter überein-stimmung mit früheren Messungen an zweien dieser Systeme. Für Methanol + n-Heptan stimmt der Wert für dT/dP offensichtlich nicht mit Werten, die mit Hilfe von Daten für die spezifische Wärme und die thermische Ausdehnung vorhergesagt wurden, überein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental studies on the measurement of pressure fields in the region of separating and reattaching flows behind several two-dimensional fore-bodies and one axisymmetric body are reported. In particular, extensive measurements of mean pressure, surface pressure fluctuation, and pressure fluctuation within the flow were made for a series of two-dimensional fore-body shapes consisting of triangular nose with varying included angle. The measurements from different bodies are compared and one of the important findings is that the maximum values of rms pressure fluctuation levels in the shear layer approaching reattachment are almost equal to the maximum value of the surface fluctuation levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basic principles of operation of gas sensors based on solid-state galvanic cells are described. The polarisation of the electrodes can be minimised by the use of point electrodes made of the solid electrolyte, the use of a reference system with chemical potential close to that of the sample system and the use of graded condensed phase reference electrodes. Factors affecting the speed of response of galvanic sensors in equilibrium and non-equilibrium gas mixtures are considered with reference to products of combustion of fossil fuels. An expression for the emf of non-isothermal galvanic sensors and the criterion for the design of temperature compensated reference electrodes for non-isothermal galvanic sensors are briefly outlined. Non-isothermal sensors are useful for the continuous monitoring of concentrations or chemical potentials in reactive systems at high temperatures. Sensors for oxygen, carbon, and alloying elements (Zn and Si) in liquid metals and alloys are discussed. The use of auxiliary electrodes permits the detection of chemical species in the gas phase which are not mobile in the solid electrolyte. Finally, the cause of common errors in galvanic measurements, and tests for correct functioning of galvanic sensors are given. 60 ref.--AA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of a pressure transducer with meandering-path thin film strain gauges has been studied. Details of the procedure followed to prepare the thin film strain gauge system on the pressure transducer diaphragm are given. The effect of post-deposition heat treatment on the resistance of the sensing films of the strain gauges and the insulating base layers are discussed. The output of the pressure transducer was studied with various input pressures and excitation voltages. It was found that up to a maximum of 10 V bridge excitation the output was stable and repetitive. The maximum non-linearity and hysteresis observed are ±0.15%, ±0.16% and ±0.14% FSO (full-scale output) for 5, 7.5 and 10 V excitation respectively. Information on the output behaviour of the pressure transducer with temperature is also included.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is focused on the development and evaluation of ion mobility instrumentation with various atmospheric pressure ionization techniques and includes the following work. First, a high-resolution drift tube ion mobility spectrometer (IMS), coupled with a commercial triple quadrupole mass spectrometer (MS), was developed. This drift tube IMS is compatible with the front-end of commercial Sciex mass spectrometers (e.g., Sciex API-300, 365, and 3000) and also allows easy (only minor modifications are needed) installation between the original atmospheric pressure ion source and the triple quadrupole mass spectrometer. Performance haracteristics (e.g.,resolving power, detection limit, transmission efficiency of ions) of this IMS-MS instrument were evaluated. Development of the IMS-MS instrument also led to a study where a proposal was made that tetraalkylammonium ions can be used as chemical standards for ESI-IMS. Second, the same drift tube design was also used to build a standalone ion mobility spectrometer equipped with a Faraday plate detector. For this highresolution (resolving power about 100 shown) IMS device, a multi-ion source platform was built, which allows the use of a range of atmospheric pressure ionization methods, such as: corona discharge chemical ionization (CD-APCI), atmospheric pressure photoionization (APPI), and radioactive atmospheric pressure chemical ionization (R-APCI). The multi-ion source platform provides easy switching between ionization methods and both positive and negative ionization modes can be used. Third, a simple desorpion/ionization on silicon (DIOS) ion source set-up for use with the developed IMS and IMS-MS instruments was built and its operation demonstrated. Fourth, a prototype of a commercial aspiration-type ion mobility spectrometer was mounted in front of a commercial triple quadrupole mass spectrometer. The set-up, which is simple, easy to install, and requires no major modifications to the MS, provides the possibility of gathering fundamental information about aspiration mobility spectrometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A diaphragm-type pressure transducer with a sputtered platinum film strain gauge (sensing film) has been designed and fabricated. The various steps followed to prepare thin film strain gauges on the diaphragm are described. M-bond 450 adhesive (Measurements Group, USA) has been employed as the insulating layer. A detailed procedure to cure this layer is given. A d.c. sputtering method is employed to prepare the platinum films. This paper also includes details of the strain gauge pattern and its location on the diaphragm. A description of the output characteristics and overall behaviour of the platinum thin film pressure transducer is reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dc electrical conductivity of TlInX2 (X = Se, Te) single crystals, parallel and perpendicular to the (001) c-axis is studied under high quasi-hydrostatic pressure up to 7.0 GPa, at room temperature. Conductivity measurements parallel to the c-axis are carried out at high pressures and down to liquid nitrogen temperatures. These materials show continuous metallization under pressure. Both compounds have almost the same pressure coefficient of the electrical activation energy parallel to the c-axis, d(ΔE∥)/dP = −2.9 × 10−10 eV/Pa, which results from the narrowing of the band gap under pressure. The results are discussed in the light of the band structure of these compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wide-line proton NMR spectra of ammonium thiocyanate have been recorded at 77 K as a function of external hydrostatic pressure. Contrary to expectations the line-width and the second moment decrease with the increase of pressure. This, however, is in accordance with the anomalous behaviour observed in other magnetic resonance studies of this compound and can be understood in terms of the change of electron density around the nitrogen atom of the SCN- group.