954 resultados para ICC-profiler
Resumo:
För ett par månader sedan kompletterade Sociologiska institutionen vid Uppsala universitetet en serie av sju års mätningar av svenska attityder till den etniska mångfalden, Mångfaldsbarometern (Mella, Palm & Bromark, 2011). De gjorda mätningarna tillåter oss att fastställa och tolka vissa tendenser som stabila profiler. Det handlar i första hand om allmänna attityder, hur folket ställer sig till invandringen, vilka erfarenheter man uppger att man haft med de personer som kommer från andra länder och vilka attityder som utformas kring följande teman: arbetet, kulturen, religionen och bostaden.
Resumo:
Objective To investigate if a home environment test battery can be used to measure effects of Parkinson’s disease (PD) treatment intervention and disease progression. Background Seventy-seven patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study at 10 clinics in Sweden and Norway; 40 of them were treated with levodopa-carbidopa intestinal gel (LCIG) and 37 patients were candidates for switching from oral PD treatment to LCIG. They utilized a mobile device test battery, consisting of self-assessments of symptoms and objective measures of motor function through a set of fine motor tests (tapping and spiral drawings), in their homes. Both the LCIG-naïve and LCIG-non-naïve patients used the test battery four times per day during week-long test periods. Methods Assessments The LCIG-naïve patients used the test battery at baseline (before LCIG), month 0 (first visit; at least 3 months after intraduodenal LCIG), and thereafter quarterly for the first year and biannually for the second and third years. The LCIG-non-naïve patients used the test battery from the first visit, i.e. month 0. Out of the 77 patients, only 65 utilized the test battery; 35 were LCIG-non-naïve and 30 LCIG-naïve. In 20 of the LCIG-naïve patients, assessments with the test battery were available during oral treatment and at least one test period after having started infusion treatment. Three LCIG-naïve patients did not use the test battery at baseline but had at least one test period of assessments thereafter. Hence, n=23 in the LCIG-naïve group. In total, symptom assessments in the full sample (including both patient groups) were collected during 379 test periods and 10079 test occasions. For 369 of these test periods, clinical assessments including UPDRS and PDQ-39 were performed in afternoons at the start of the test periods. The repeated measurements of the test battery were processed and summarized into scores representing patients’ symptom severities over a test period, using statistical methods. Six conceptual dimensions were defined; four subjectively-reported: ‘walking’, ‘satisfied’, ‘dyskinesia’, and ‘off’ and two objectively-measured: ‘tapping’ and ‘spiral’. In addition, an ‘overall test score’ (OTS) was defined to represent the global health condition of the patient during a test period. Statistical methods Change in the test battery scores over time, that is at baseline and follow-up test periods, was assessed with linear mixed-effects models with patient ID as a random effect and test period as a fixed effect of interest. The within-patient variability of OTS was assessed using intra-class correlation coefficient (ICC), for the two patient groups. Correlations between clinical rating scores and test battery scores were assessed using Spearman’s rank correlations (rho). Results In LCIG-naïve patients, mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. However, there were no significant changes in mean OTS scores of LCIG-non-naïve patients, except for worse mean OTS at month 36 (p<0.01, n=16). The mean scores of all subjectively-reported dimensions improved significantly throughout the course of the study, except ‘walking’ at month 36 (p=0.41, n=4). However, there were no significant differences in mean scores of objectively-measured dimensions between baseline and other test periods, except improved ‘tapping’ at month 6 and month 36, and ‘spiral’ at month 3 (p<0.05). The LCIG-naïve patients had a higher within-subject variability in their OTS scores (ICC=0.67) compared to LCIG-non-naïve patients (ICC=0.71). The OTS correlated adequately with total UPDRS (rho=0.59) and total PDQ-39 (rho=0.59). Conclusions In this 3-year follow-up study of advanced PD patients treated with LCIG we found that it is possible to monitor PD progression over time using a home environment test battery. The significant improvements in the mean OTS scores indicate that the test battery is able to measure functional improvement with LCIG sustained over at least 24 months.
Resumo:
Objective: To develop a method for objective quantification of PD motor symptoms related to Off episodes and peak dose dyskinesias, using spiral data gathered by using a touch screen telemetry device. The aim was to objectively characterize predominant motor phenotypes (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Background: A retrospective analysis was conducted on recordings from 65 patients with advanced idiopathic PD from nine different clinics in Sweden, recruited from January 2006 until August 2010. In addition to the patient group, 10 healthy elderly subjects were recruited. Upper limb movement data were collected using a touch screen telemetry device from home environments of the subjects. Measurements with the device were performed four times per day during week-long test periods. On each test occasion, the subjects were asked to trace pre-drawn Archimedean spirals, using the dominant hand. The pre-drawn spiral was shown on the screen of the device. The spiral test was repeated three times per test occasion and they were instructed to complete it within 10 seconds. The device had a sampling rate of 10Hz and measured both position and time-stamps (in milliseconds) of the pen tip. Methods: Four independent raters (FB, DH, AJ and DN) used a web interface that animated the spiral drawings and allowed them to observe different kinematic features during the drawing process and to rate task performance. Initially, a number of kinematic features were assessed including ‘impairment’, ‘speed’, ‘irregularity’ and ‘hesitation’ followed by marking the predominant motor phenotype on a 3-category scale: tremor, bradykinesia and/or choreatic dyskinesia. There were only 2 test occasions for which all the four raters either classified them as tremor or could not identify the motor phenotype. Therefore, the two main motor phenotype categories were bradykinesia and dyskinesia. ‘Impairment’ was rated on a scale from 0 (no impairment) to 10 (extremely severe) whereas ‘speed’, ‘irregularity’ and ‘hesitation’ were rated on a scale from 0 (normal) to 4 (extremely severe). The proposed data-driven method consisted of the following steps. Initially, 28 spatiotemporal features were extracted from the time series signals before being presented to a Multilayer Perceptron (MLP) classifier. The features were based on different kinematic quantities of spirals including radius, angle, speed and velocity with the aim of measuring the severity of involuntary symptoms and discriminate between PD-specific (bradykinesia) and/or treatment-induced symptoms (dyskinesia). A Principal Component Analysis was applied on the features to reduce their dimensions where 4 relevant principal components (PCs) were retained and used as inputs to the MLP classifier. Finally, the MLP classifier mapped these components to the corresponding visually assessed motor phenotype scores for automating the process of scoring the bradykinesia and dyskinesia in PD patients whilst they draw spirals using the touch screen device. For motor phenotype (bradykinesia vs. dyskinesia) classification, the stratified 10-fold cross validation technique was employed. Results: There were good agreements between the four raters when rating the individual kinematic features with intra-class correlation coefficient (ICC) of 0.88 for ‘impairment’, 0.74 for ‘speed’, 0.70 for ‘irregularity’, and moderate agreements when rating ‘hesitation’ with an ICC of 0.49. When assessing the two main motor phenotype categories (bradykinesia or dyskinesia) in animated spirals the agreements between the four raters ranged from fair to moderate. There were good correlations between mean ratings of the four raters on individual kinematic features and computed scores. The MLP classifier classified the motor phenotype that is bradykinesia or dyskinesia with an accuracy of 85% in relation to visual classifications of the four movement disorder specialists. The test-retest reliability of the four PCs across the three spiral test trials was good with Cronbach’s Alpha coefficients of 0.80, 0.82, 0.54 and 0.49, respectively. These results indicate that the computed scores are stable and consistent over time. Significant differences were found between the two groups (patients and healthy elderly subjects) in all the PCs, except for the PC3. Conclusions: The proposed method automatically assessed the severity of unwanted symptoms and could reasonably well discriminate between PD-specific and/or treatment-induced motor symptoms, in relation to visual assessments of movement disorder specialists. The objective assessments could provide a time-effect summary score that could be useful for improving decision-making during symptom evaluation of individualized treatment when the goal is to maximize functional On time for patients while minimizing their Off episodes and troublesome dyskinesias.
Resumo:
Introdução: a incidência dos melanomas permanece em ascensão em diversos países. Os nevos melanocíticos podem ser seus precursores ou marcadores de risco. A radiação ultravioleta é o principal fator de risco ambiental para o seu desenvolvimento. Estudos com nevos irradiados mostram que a radiação ultravioleta B (UVB) pode causar alterações morfológicas e bioquímicas semelhantes às de um melanoma in situ. As metaloproteinases da matriz (MMP) são enzimas proteolíticas e, particularmente, as MMP-2 e –9 (gelatinases A e B) parecem estar associadas à invasão tumoral, à formação de metástases e de neoangiogênese em melanomas. O objetivo do presente estudo é avaliar os efeitos da UVB nas expressões imunoistoquímicas de MMP-2 e –9 nas diferentes linhagens celulares de nevos melanocíticos. Métodos: quarenta e dois nevos melanocíticos tiveram suas metades irradiadas com dose de 2 DEM (dose eritematosa mínima) de UVB e foram excisados uma semana após. As expressões imunoistoquímicas das MMP-2 e -9 foram comparadas, quanto à sua intensidade, por três avaliadores diferentes entre os lados irradiados e não irradiados em queratinócitos, melanócitos de epiderme e derme superior, células endoteliais e fibroblastos. Os dados foram analisados pelo teste t pareado para as diferenças de expressão e pelo ICC para avaliação da homogeneidade entre as respostas dos observadores. Resultados: com relação à expressão imunoistoquímica de MMP-2, todas as linhagens celulares mostraram aumento no lado irradiado, especialmente os melanócitos epidérmicos. Quanto à MMP-9, somente nos queratinócitos, não se observou aumento de expressão do lado irradiado, ficando essa evidente nas demais linhagens celulares avaliadas. Conclusões: A UVB na dose de 2 DEM aumenta a expressão imunoistoquímica das MMP-2 e –9 em quase todas as linhagens celulares dos nevos melanocíticos avaliados até uma semana após a irradiação, com exceção feita queratinócitos, com a MMP-9.
Resumo:
This study aimed at assessing the interobserver reliability of the Brazilian-Portuguese version of the Berg Balance Scale (BBS). The assessment was made by physiotherapists with extensive or little clinical experience in non-institutionalized elderly individuals. Participants comprised 12 elderly subjects (10 women and 2 men) with mean ages of 75.8 ± 8.4 years (range = 63-87) and 18 physiotherapists with varying clinical experience. Inter-examiner reliability obtained for each scale item yielded weighted kappa value > 0.75 in 11 of the 14 items (varying from 0.37 to 1.0). The intra-class correlation coefficient (ICC) for the total sum of BBS scores between the two groups of physiotherapists was 0.996 (95% confidence interval, 0.987 0.999) with a Cronbach alpha coefficient of 0.996. We found no difference between the rater groups when we compared the sum score means obtained with the student s T-test (p = 0.86). Although some items had low reliability values, in general our results suggest that the Brazilian Version of the BBS showed good levels of interrater reliability and agreement when used by physiotherapists with different clinical practice levels and without previous training on non-institutionalized elderly patients. We concluded that the BBS can be useful as an important evaluation instrument on a protocol for Rehabilitation clinics. It may be used by various health professionals, as: Physicians, Physical therapists, Physical educators, Occupational therapists, Nurses and Phonoaudiologists, so confirming the interdisciplinary character of this study
Resumo:
Introduction: Chagas Disease is a serious public health problem, with 5 million infected individuals in Brazil. Of these, approximately 30% develop chronic Chagas cardiomyopathy (CCC), where the main symptoms are fatigue and dyspnea. Objective: To correlate maximal exercise capacity with pulmonary function, inspiratory muscle strength and quality of life in patients with CCC. Methodology: Twelve individuals suffering from CCC were evaluated (7 men), with a mean age of 54.91± 8.60 years and the following inclusion criteria: functional class II and III according to the New York Heart Association (NYHA); left ventricle ejection fraction below 45%; clinical stability (> 3 months); symptom duration > 1 year, body mass index (BMI) < 35Kg/m2 and non-smokers or ex-smokers with a history of smoking <10 packs/day. All subjects were submitted to spirometry, manometer testing, maximal cardiopulmonary exercise testing (CPX) and a quality of life questionnaire (Minnesota). Results: A negative correlation was observed between VO2máx and MLHFQ scores (r=-0.626; p=0.03) and a positive association with MIP (r=0.713; p=0.009). Positive correlations were also recorded between MIP and spirometric variables [FEV1(r=0.825;p=0.001 ), FVC(r=0.66;p=0.01 and FEF25-75%(r=0.639;p=0.02)]. Conclusion: The present study demonstrated that in patients with CCC: VO2MAX is directly related to inspiratory muscle strength and quality of life, while deteriorating lung function is directly associated with respiratory muscle weakness
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Resumo:
A doença degenerativa mixomatosa da válvula mitral (DDMVM) é uma cardiopatia de alta incidência na clínica médica de pequenos animais, acometendo mormente cães idosos e raças de pequeno porte. Desta forma, foi realizada uma investigação científica objetivando avaliar clinicamente a utilização dos fármacos maleato de enalapril e furosemida em cães com a referida enfermidade na classe funcional Ib da ICC, antes e após a terapêutica implantada. Para isso, utilizaram-se 16 cães portadores da valvulopatia supracitada, distribuídos em dois grupos; com o primeiro recebendo furosemida (n=8) e o segundo maleato de enalapril (n=8), durante 56 dias. Os cães foram avaliados em quatro momentos (T0, T14, T28 e T56 dias) quanto aos sinais clínicos e parâmetros hematológicos e bioquímico-séricos, que incluíram concentrações séricas da enzima conversora da angiotensina (ECA) e aldosterona, como também avaliações radiográficas, eletrocardiográficas, ecodopplercardiográficas e da pressão arterial. Os resultados quanto aos parâmetros clínicos, avaliações hematológicas e bioquímicas séricas não revelaram alterações significativas em ambos os grupos, mas reduções significativas nos valores de ECA e aldosterona no grupo que recebeu o maleato de enalapril foram identificadas. Ao exame radiográfico observou-se reduções nos valores de VHS e na variável onda Pms do eletrocardiograma em ambos os grupos, mas sem alterações nos valores da pressão arterial. Por sua vez, o ecodopplercardiograma evidenciou diminuição significativa das variáveis DIVEd/s nos grupos estudados e na FEC% nos cães que receberam somente enalapril. Portanto, a análise dos resultados encontrados indicou que a monoterapia fundamentada no maleato de enalapril apresentou melhor eficiência no controle do quadro clínico em pacientes da classe funcional Ib da ICC.
Resumo:
The Brain-Computer Interfaces (BCI) have as main purpose to establish a communication path with the central nervous system (CNS) independently from the standard pathway (nervous, muscles), aiming to control a device. The main objective of the current research is to develop an off-line BCI that separates the different EEG patterns resulting from strictly mental tasks performed by an experimental subject, comparing the effectiveness of different signal-preprocessing approaches. We also tested different classification approaches: all versus all, one versus one and a hierarchic classification approach. No preprocessing techniques were found able to improve the system performance. Furthermore, the hierarchic approach proved to be capable to produce results above the expected by literature
Resumo:
This study aimed to analyze the effects of nandrolone decanoate on the ovaries and uterus of adult females rats. This drug was administered intraperitoneally, at one, two and three doses of 3 mg nandrolone decanoate/kg of body weight, respectively, in the first, second and third week of treatment. The females of the control group received a physiological solution. The rats treated with nandrolone decanoate showed estral acyclicity and there was destruction of follicular units and an absence of corpus luteum in the ovaries. In the uterus, the drug promoted morphological alterations, characterized by vacuolated epithelium and endometrial stroma fibrosis. Ovary, uterus and pituitary weights were not affected by the steroid treatment. Nandrolone decanoate affects the sexual cycle and promotes histological alterations in the ovaries and uterus of adult female rats. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to analyze the reproducibility of the electromyography signal's parameters (EMG) in the frequency domain used in the characterization of localized muscle fatigue. Fifteen male subjects underwent a fatigue test based on isometric knee extension, being held at three different times at intervals of seven days. To assess the reproducibility of data between the tests we calculated the correlation coefficient (ICC) for the median frequency (MF) in total exercise time (MFT), MF obtained for every 10% of exercise time (MF10%) and the powers of the frequency bands obtained by dividing the power spectrum at windows of 20 Hz. The results showed: (1) excellent reproducibility for MFT, (2) good reproducibility for MF10%, and (3) greater variation in the signal EMG bands from 20 to 120 Hz, especially at the bands of 20-40 Hz and 40-60 Hz, which showed greater sensitivity to the process of muscle fatigue. We conclude that the MF is a variable that shows good reproducibility and that the fragmented analysis of the power spectrum, by means of frequency bands, showed that significant variations occur in the EMG signal during the installation of the fatigue process, having potential to become a new method for the characterization of localized muscle fatigue.
Resumo:
Introdução: The scales of cognitive screening are important tools for early detection of dementia, creating the possibility of developing measures to slow this process and assist in the management of the disease. Objective: To validate the Leganés Cognitive Test (Prueba Cognitive de Leganés) (PCL) for cognitive screening in low educated elderly Brazilians. Methods: The study sample was composed of 59 elderly residents from the city of Santa Cruz, Brazil with low schooling levels. Reliability was analyzed with a 2-day interval between assessments, and concurrent validity was assessed using the Mini Mental State Examination (MMSE). Results: According to the PCL, the prevalence of dementia was 11.8%. The scale items showed a moderate to strong correlation between domains (p <0.01), and inter-rater reliability exhibited ICC = 0.81, 95% CI (0.72-0.88). Factor analysis resulted in two factors: memory and orientation. Interscale agreement was considered poor (k = - 0.02), supporting the hypothesis of an educational impact on final MMSE scores. Conclusion: The results suggest that PCL has acceptable levels of reliability for use in low educated elderly Brazilians
Resumo:
Objectives: to translate and assess the psychometric properties of the Brazilian short-form of the Mobility Assessment Tool (MAT-sf) in Brazilians community elderly. Methds: the 12 items MAT-sf went through the process of translation and back translation into Portuguese of the Brazil, considering the semantic and cultural adaptation. In a sample of 150 aged 65-74 years living in the community, the instrument's psychometric properties were evaluated by analysis of convergent and construct validity and test-retest reliability. The main outcomes measures used for validation included in the battery of tests of physical ability, self-repor measures of functional limitations, health, depression, cognitive and sex. The test-retest reliability of the instrument was assessed using the intra-class correlation coefficient (ICC), 40 subjects were reassessed after an interval of 14 days of assessment. Results: the concurrent validity for the MAT-sf was evidenced by significant correlations with SPPB (r = 0,53), number of functional limitations (r = -0,62) and depressive symptoms (r = -0,45). The construct validity of the instrument was measured by gradual and significant increase of the MAT-sf scores with high levels of physical performance and with positive self-reported health, also found that MAT-sf scores were statistically differents according to sex. The variation in MAT-sf scores (R2 = 0,41) was explained by SPPB, number of limitations for activities of daily life and depressive symptoms. High values for test-retest reliability was evidencend by ICC = 0,94, 95% CI = 0,90 0,97. Conclusions: the Brazilian version of the short-form of the Mobility Assessment Tool has values of validity and reliability to ensure its use in elderly populations living in communities
Resumo:
The Wii Balance Board (WBB) began to be investigated as a low-cost alternative for assessing static balance in vertical posture. However, studies employed methodological procedures that did not eliminate result variability between the tests and equipment used. Objective: Determine the validity and reproducibility of the WBB as an instrument for assessing static balance in the vertical position, using simultaneous data analysis and superimposed equipment. Methods: This is an accuracy study of 29 healthy young individuals of both sexes aged 18 to 30 years. Subjects were assessed 24h apart (test-retest), using unipodal and bipodal support tests, with eyes closed and open. To that end the WBB was placed on top of a force platform (FP) and data (postural sway) were collected simultaneously on both devices. Validity and reproducibility were analyzed using the interclass correlation coefficient (ICC). Finally, Bland-Altman analysis was applied to assess agreement. Results: The sample was composed of 23 women and 6 men, with mean age of 24.2±6.3 years, 60.7±6.3 kg and 1.64±4.2 m. The validity of the WBB compared to the FP was excellent for all 4 tasks proposed (ICC = 0.93 0.98). The reproducibility analyzed by test-retest was excellent for the bipodal support tasks (ICC = 0.93-0.98) and only moderate for the unipodal support tests (ICC = 0.46 0.70). Graphic analysis exhibited good agreement between the devices, since most of the measures were within the limits of agreement. Conclusion: this study proved the validity and reproducibility of the Wii Balance Board as an instrument for assessing static balance in vertical posture, using simultaneous analysis with superimposed equipment. Thus, the WBB has been increasingly used by physical therapists and other health professionals in their clinical practice, as both a rehabilitation and assessment tool
Resumo:
The calculation of tooth mass discrepancy, essential for good planning and a proper orthodontic finishing, when performed manually, besides being laborious, requires considerable time consumption. The aim of this study was to develop and test Bolton Freeware, a software for analysis of the tooth mass discrepancy of Bolton, aiming to minimize the consumption of time in a less onerous way. The digital analysis of the software was done by means of two-dimensional scanning of plaster study models and compared to manual evaluation (gold standard), using 75 pairs of stone plaster study models divided into two groups according to the magnitude of the Curve of Spee (group I from 0 to 2 mm, group II greater than 2 to 3mm). All the models had permanent dentition and were in perfect condition. The manual evaluation was performed with a digital caliper and a calculator, and the time required to perform the analysis for both methods was recorded and compared. In addition, the software was evaluated by orthodontists regarding its use, by means of questionnaires developed specifically for this purpose. Calibration was performed prior to manual analysis, and excellent levels of inter-rater agreement were achieved, with ICC > 0.75 and r > 0.9 for total and anterior proportion. It was observed in the evaluation of error of the digital method that some teeth showed a significant systematic error, being the highest measured at 0.08 mm. The analysis of total tooth mass discrepancy performed by Bolton Freeware, for those cases in which the curve of Spee is mild and moderate, differ from manual analysis, on average, 0.09 mm and 0.07 mm respectively, for each tooth evaluated, with r> 0, 8 for total and anterior proportion. According to the specificity and sensitivity test, Bolton Freeware has an improved ability to detect true negatives, i.e. the presence of discrepancy. The Bolton analysis digitally performed was faster, with an average difference of time consumed to perform the analysis of Bolton between the two methods of approximately 6 minutes. Most experts interviewed (93%) approved the usability of the software