899 resultados para Definite


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Newer-generation drug-eluting stents that release zotarolimus or everolimus have been shown to be superior to the first-generation drug-eluting stents. However, data comparing long-term safety and efficacy of zotarolimus- (ZES) and everolimus-eluting stents (EES) are limited. RESOLUTE all-comers (Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) trial compared these 2 stents and has shown that ZES was noninferior to EES at 12-month for the primary end point of target lesion failure. We report the secondary clinical outcomes at the final 5-year follow-up of this trial. METHODS AND RESULTS RESOLUTE all-comer clinical study is a prospective, multicentre, randomized, 2-arm, open-label, noninferiority trial with minimal exclusion criteria. Patients (n=2292) were randomly assigned to treatment with either ZES (n=1140) or EES (n=1152). Patient-oriented composite end point (combination of all-cause mortality, myocardial infarction, and any revascularizations), device-oriented composite end point (combination of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization), and major adverse cardiac events (combination of all-cause death, all myocardial infarction, emergent coronary bypass surgery, or clinically indicated target lesion revascularization) were analyzed at 5-year follow-up. The 2 groups were well-matched at baseline. Five-year follow-up data were available for 98% patients. There were no differences in patient-oriented composite end point (ZES 35.3% versus EES 32.0%, P=0.11), device-oriented composite end point (ZES 17.0% versus EES 16.2%, P=0.61), major adverse cardiac events (ZES 21.9% versus EES 21.6%, P=0.88), and definite/probable stent thrombosis (ZES 2.8% versus EES 1.8%, P=0.12). CONCLUSIONS At 5-year follow-up, ZES and EES had similar efficacy and safety in a population of patients who had minimal exclusion criteria. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00617084.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium metal alloy platform with an ultrathin bioabsorbable Poly(D,L-lactide-co-glycolide) abluminal everolimus-eluting polymer. We performed a multicenter, randomized controlled trial for regulatory approval to determine noninferiority of the SYNERGY stent to the durable polymer PROMUS Element Plus everolimus-eluting stent. METHODS AND RESULTS Patients (n=1684) scheduled to undergo percutaneous coronary intervention for non-ST-segment-elevation acute coronary syndrome or stable coronary artery disease were randomized to receive either the SYNERGY stent or the PROMUS Element Plus stent. The primary end point of 12-month target lesion failure was observed in 6.7% of SYNERGY and 6.5% PROMUS Element Plus treated subjects by intention-to-treat (P=0.83 for difference; P=0.0005 for noninferiority), and 6.4% in both the groups by per-protocol analysis (P=0.0003 for noninferiority). Clinically indicated revascularization of the target lesion or definite/probable stent thrombosis were observed in 2.6% versus 1.7% (P=0.21) and 0.4% versus 0.6% (P=0.50) of SYNERGY versus PROMUS Element Plus-treated subjects, respectively. CONCLUSIONS In this randomized trial, the SYNERGY bioabsorbable polymer everolimus-eluting stent was noninferior to the PROMUS Element Plus everolimus-eluting stent with respect to 1-year target lesion failure. These data support the relative safety and efficacy of SYNERGY in a broad range of patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01665053.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The benefits and risks of prolonged dual antiplatelet therapy may be different for patients with acute myocardial infarction (MI) compared with more stable presentations. OBJECTIVES This study sought to assess the benefits and risks of 30 versus 12 months of dual antiplatelet therapy among patients undergoing coronary stent implantation with and without MI. METHODS The Dual Antiplatelet Therapy Study, a randomized double-blind, placebo-controlled trial, compared 30 versus 12 months of dual antiplatelet therapy after coronary stenting. The effect of continued thienopyridine on ischemic and bleeding events among patients initially presenting with versus without MI was assessed. The coprimary endpoints were definite or probable stent thrombosis and major adverse cardiovascular and cerebrovascular events (MACCE). The primary safety endpoint was GUSTO (Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Arteries) moderate or severe bleeding. RESULTS Of 11,648 randomized patients (9,961 treated with drug-eluting stents, 1,687 with bare-metal stents), 30.7% presented with MI. Between 12 and 30 months, continued thienopyridine reduced stent thrombosis compared with placebo in patients with and without MI at presentation (MI group, 0.5% vs. 1.9%, p < 0.001; no MI group, 0.4% vs. 1.1%, p < 0.001; interaction p = 0.69). The reduction in MACCE for continued thienopyridine was greater for patients with MI (3.9% vs. 6.8%; p < 0.001) compared with those with no MI (4.4% vs. 5.3%; p = 0.08; interaction p = 0.03). In both groups, continued thienopyridine reduced MI (2.2% vs. 5.2%, p < 0.001 for MI; 2.1% vs. 3.5%, p < 0.001 for no MI; interaction p = 0.15) but increased bleeding (1.9% vs. 0.8%, p = 0.005 for MI; 2.6% vs. 1.7%, p = 0.007 for no MI; interaction p = 0.21). CONCLUSIONS Compared with 12 months of therapy, 30 months of dual antiplatelet therapy reduced the risk of stent thrombosis and MI in patients with and without MI, and increased bleeding. (The Dual Antiplatelet Therapy Study [The DAPT Study]; NCT00977938).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND An increased body mass index (BMI) is associated with a high risk of cardiovascular disease and reduction in life expectancy. However, several studies reported improved clinical outcomes in obese patients treated for cardiovascular diseases. The aim of the present study is to investigate the impact of BMI on long-term clinical outcomes after implantation of zotarolimus eluting stents. METHODS Individual patient data were pooled from the RESOLUTE Clinical Program comprising five trials worldwide. The study population was sorted according to BMI tertiles and clinical outcomes were evaluated at 2-year follow-up. RESULTS Data from a total of 5,127 patients receiving the R-ZES were included in the present study. BMI tertiles were as follow: I tertile (≤ 25.95 kg/m(2) -Low or normal weight) 1,727 patients; II tertile (>25.95 ≤ 29.74 kg/m(2) -overweight) 1,695 patients, and III tertile (>29.74 kg/m(2) -obese) 1,705 patients. At 2-years follow-up no difference was found for patients with high BMI (III tertile) compared with patients with normal or low BMI (I tertile) in terms of target lesion failure (I-III tertile, HR [95% CI] = 0.89 [0.69, 1.14], P = 0.341; major adverse cardiac events (I-III tertile, HR [95% CI] = 0.90 [0.72, 1.14], P = 0.389; cardiac death (I-III tertile, HR [95% CI] = 1.20 [0.73, 1.99], P = 0.476); myocardial infarction (I-III tertile, HR [95% CI] = 0.86 [0.55, 1.35], P = 0.509; clinically-driven target lesion revascularization (I-III tertile, HR [95% CI] = 0.75 [0.53, 1.08], P = 0.123; definite or probable stent thrombosis (I-III tertile, HR [95% CI] = 0.98 [0.49, 1.99], P = 0.964. CONCLUSIONS In the present study, the patients' body mass index was found to have no impact on long-term clinical outcomes after coronary artery interventions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Buruli ulcer (BU) is a necrotizing skin disease most prevalent among West African children. The causative organism, Mycobacterium ulcerans, is sensitive to temperatures above 37°C. We investigated the safety and efficacy of a local heat application device based on phase change material. METHODS In a phase II open label single center noncomparative clinical trial (ISRCTN 72102977) under GCP standards in Cameroon, laboratory confirmed BU patients received up to 8 weeks of heat treatment. We assessed efficacy based on the endpoints 'absence of clinical BU specific features' or 'wound closure' within 6 months ("primary cure"), and 'absence of clinical recurrence within 24 month' ("definite cure"). RESULTS Of 53 patients 51 (96%) had ulcerative disease. 62% were classified as World Health Organization category II, 19% each as category I and III. The average lesion size was 45 cm(2). Within 6 months after completion of heat treatment 92.4% (49 of 53, 95% confidence interval [CI], 81.8% to 98.0%) achieved cure of their primary lesion. At 24 months follow-up 83.7% (41 of 49, 95% CI, 70.3% to 92.7%) of patients with primary cure remained free of recurrence. Heat treatment was well tolerated; adverse effects were occasional mild local skin reactions. CONCLUSIONS Local thermotherapy is a highly effective, simple, cheap and safe treatment for M. ulcerans disease. It has in particular potential as home-based remedy for BU suspicious lesions at community level where laboratory confirmation is not available. CLINICAL TRIALS REGISTRATION ISRCT 72102977.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND In percutaneous coronary intervention (PCI) patients new-generation drug-eluting stent (DES) has reduced adverse events in comparison to early-generation DES. The aim of the current study was to investigate the long-term clinical efficacy and safety of new-generation DES versus early-generation DES for PCI of unprotected left main coronary artery (uLMCA) disease. METHODS The patient-level data from the ISAR-LEFT MAIN and ISAR-LEFT MAIN 2 randomized trials were pooled. The clinical outcomes of PCI patients assigned to new-generation DES (everolimus- or zotarolimus-eluting stent) versus early-generation DES (paclitaxel- or sirolimus-eluting stent) were studied. The primary endpoint was the composite of death, myocardial infarction (MI), target lesion revascularization and stroke (MACCE, major adverse cardiac and cerebrovascular event). RESULTS In total, 1257 patients were available. At 3 years, the risk of MACCE was comparable between patients assigned to new-generation DES or early-generation DES (28.2 versus 27.5 %, hazard ratio-HR 1.03, 95 % confidence intervals-CI 0.83-1.26; P = 0.86). Definite/probable stent thrombosis was low and comparable between new-generation DES and early-generation DES (0.8 versus 1.6 %, HR 0.52, 95 % CI 0.18-1.57; P = 0.25); in patients treated with new-generation DES no cases occurred beyond 30 days. Diabetes increased the risk of MACCE in patients treated with new-generation DES but not with early-generation DES (P interaction = 0.004). CONCLUSIONS At 3-year follow-up, a PCI with new-generation DES for uLMCA disease shows comparable efficacy to early-generation DES. Rates of stent thrombosis were low in both groups. Diabetes significantly impacts the risk of MACCE at 3 years in patients treated with new-generation DES for uLMCA disease. ClinicalTrials.gov Identifiers: NCT00133237; NCT00598637.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. METHODS In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). RESULTS The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). CONCLUSIONS The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OPINION STATEMENT Children who present with acute neurological symptoms suggestive of a stroke need immediate clinical assessment and urgent neuroimaging to confirm diagnosis. Magnetic resonance imaging (MRI) is the investigation of first choice due to limited sensitivity of computed tomography (CT) for detection of ischaemia. Acute monitoring should include monitoring of blood pressure and body temperature, and neurological observations. Surveillance in a paediatric high dependency or intensive care unit and neurosurgical consultation are mandatory in children with large infarcts at risk of developing malignant oedema or haemorrhagic transformation. Thrombolysis and/or endovascular treatment, whilst not currently approved for use in children, may be considered when stroke diagnosis is confirmed within 4.5 to 6 h, provided there are no contraindications on standard adult criteria. Standard treatment consists of aspirin, but anticoagulation therapy is frequently prescribed in stroke due to cardiac disease and extracranial dissection. Steroids and immunosuppression have a definite place in children with proven vasculitis, but their role in focal arteriopathies is less clear. Decompressive craniotomy should be considered in children with deteriorating consciousness or signs of raised intracranial pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Importance: Although rheumatic heart disease has been nearly eradicated in high-income countries, 3 in 4 children grow up in parts of the world where it is still endemic. Objectives: To determine the prevalence of clinically silent and manifest rheumatic heart disease as a function of age, sex, and socioeconomic status and to estimate age-specific incidence. Design, Setting, and Participants: In this school-based cross-sectional study with cluster sampling, 26 schools in the Sunsari district in Eastern Nepal with 5467 eligible children 5 to 15 years of age were randomly selected from 595 registered schools. After exclusion of 289 children, 5178 children were enrolled in the present study from December 12, 2012, through September 12, 2014. Data analysis was performed from October 1, 2014, to April 15, 2015. Exposures: Demographic and socioeconomic characteristics were acquired in a standardized interview by means of a questionnaire customized to the age of the children. A focused medical history was followed by a brief physical examination. Cardiac auscultation and transthoracic echocardiography were performed by 2 independent physicians. Main Outcomes and Measures: Rheumatic heart disease according to the World Heart Federation criteria. Results: The median age of the 5178 children enrolled in the study was 10 years (interquartile range, 8-13 years), and 2503 (48.3%) were female. The prevalence of borderline or definite rheumatic heart disease was 10.2 (95% CI, 7.5-13.0) per 1000 children and increased with advancing age from 5.5 (95% CI, 3.5-7.5) per 1000 children 5 years of age to 16.0 (95% CI, 14.9-17.0) in children 15 years of age, whereas the mean incidence remained stable at 1.1 per 1000 children per year. Children with rheumatic heart disease were older than children without rheumatic heart disease (median age [interquartile range], 11 [9-14] years vs 10 [8-13] years; P = .03), more commonly female (34 [64.2%] vs 2469 [48.2%]; P = .02), and more frequently went to governmental schools (40 [75.5%] vs 2792 [54.5%]; P = .002). Silent disease (n = 44) was 5 times more common than manifest disease (n = 9). Conclusions and Relevance: Rheumatic heart disease affects 1 in 100 schoolchildren in Eastern Nepal, is primarily clinically silent, and may be more common among girls. The overall prevalence and the ratio of manifest to subclinical disease increase with advancing age, whereas the incidence remains stable at 1.1 per 1000 children per year. Early detection of silent disease may help prevent progression to severe valvular damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND No data are available on the long-term performance of ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES). We reported 2-year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP-SES with durable-polymer everolimus-eluting stents (DP-EES) in patients undergoing percutaneous coronary intervention. METHODS AND RESULTS A total of 2119 patients with minimal exclusion criteria were assigned to treatment with BP-SES (n=1063) or DP-EES (n=1056). Follow-up at 2 years was available for 2048 patients (97%). The primary end point was target-lesion failure, a composite of cardiac death, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. At 2 years, target-lesion failure occurred in 107 patients (10.5%) in the BP-SES arm and 107 patients (10.4%) in the DP-EES arm (risk ratio [RR] 1.00, 95% CI 0.77-1.31, P=0.979). There were no significant differences between BP-SES and DP-EES with respect to cardiac death (RR 1.01, 95% CI 0.62-1.63, P=0.984), target-vessel myocardial infarction (RR 0.91, 95% CI 0.60-1.39, P=0.669), target-lesion revascularization (RR 1.17, 95% CI 0.81-1.71, P=0.403), and definite stent thrombosis (RR 1.38, 95% CI 0.56-3.44, P=0.485). There were 2 cases (0.2%) of definite very late stent thrombosis in the BP-SES arm and 4 cases (0.4%) in the DP-EES arm (P=0.423). In the prespecified subgroup of patients with ST-segment elevation myocardial infarction, BP-SES was associated with a lower risk of target-lesion failure compared with DP-EES (RR 0.48, 95% CI 0.23-0.99, P=0.043, Pinteraction=0.026). CONCLUSIONS Comparable safety and efficacy profiles of BP-SES and DP-EES were maintained throughout 2 years of follow-up. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT01443104.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Martian surface is covered by a fine-layer of oxidized dust responsible for its red color in the visible spectral range (Bibring et al., 2006; Morris et al., 2006). In the near infrared, the strongest spectral feature is located between 2.6 and 3.6 mu m and is ubiquitously observed on the planet (Jouglet et al., 2007; Milliken et al., 2007). Although this absorption has been studied for many decades, its exact attribution and its geological and climatic implications remain debated. We present new lines of evidence from laboratory experiments, orbital and landed missions data, and characterization of the unique Martian meteorite NWA 7533, all converging toward the prominent role of hydroxylated ferric minerals. Martian breccias (so-called "Black Beauty" meteorite NWA7034 and its paired stones NWA7533 and NWA 7455) are unique pieces of the Martian surface that display abundant evidence of aqueous alteration that occurred on their parent planet (Agee et al., 2013). These dark stones are also unique in the fact that they arose from a near surface level in the Noachian southern hemisphere (Humayun et al., 2013). We used IR spectroscopy, Fe-XANES and petrography to identify the mineral hosts of hydrogen in NWA 7533 and compare them with observations of the Martian surface and results of laboratory experiments. The spectrum of NWA 7533 does not show mafic mineral absorptions, making its definite identification difficult through NIR remote sensing mapping. However, its spectra are virtually consistent with a large fraction of the Martian highlands. Abundant NWA 7034/7533 (and paired samples) lithologies might abound on Mars and might play a role in the dust production mechanism. (C) 2015 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Around 14 distinct virus species-complexes have been detected in honeybees, each with one or more strains or sub-species. Here we present the initial characterization of an entirely new virus species-complex discovered in honeybee (Apis mellifera L.) and varroa mite (Varroa destructor) samples from Europe and the USA. The virus has a naturally poly-adenylated RNA genome of about 6500 nucleotides with a genome organization and sequence similar to the Tymoviridae (Tymovirales; Tymoviridae), a predominantly plant-infecting virus family. Literature and laboratory analyses indicated that the virus had not previously been described. The virus is very common in French apiaries, mirroring the results from an extensive Belgian survey, but could not be detected in equally-extensive Swedish and Norwegian bee disease surveys. The virus appears to be closely linked to varroa, with the highest prevalence found in varroa samples and a clear seasonal distribution peaking in autumn, coinciding with the natural varroa population development. Sub-genomic RNA analyses show that bees are definite hosts, while varroa is a possible host and likely vector. The tentative name of Bee Macula-like virus (BeeMLV) is therefore proposed. A second, distantly related Tymoviridae-like virus was also discovered in varroa transcriptomes, tentatively named Varroa Tymo-like virus (VTLV).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary ciliary dyskinesia (PCD) is a rare autosomal recessive disorder leading to chronic upper and lower airway disease. Fundamental data on epidemiology, clinical presentation, course and treatment strategies are lacking in PCD. We have established an international PCD registry to realise an unmet need for an international platform to systematically collect data on incidence, clinical presentation, treatment and disease course.The registry was launched in January 2014. We used internet technology to ensure easy online access using a web browser under www.pcdregistry.eu. Data from 201 patients have been collected so far. The database is comprised of a basic data form including demographic and diagnostic information, and visit forms designed to monitor the disease course.To establish a definite PCD diagnosis, we used strict diagnostic criteria, which required two to three diagnostic methods in addition to classical clinical symptoms. Preliminary analysis of lung function data demonstrated a mean annual decline of percentage predicted forced expiratory volume in 1 s of 0.59% (95% CI 0.98-0.22).Here, we present the development of an international PCD registry as a new promising tool to advance the understanding of this rare disorder, to recruit candidates for research studies and ultimately to improve PCD care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. At present, prostate cancer screening (PCS) guidelines require a discussion of risks, benefits, alternatives, and personal values, making decision aids an important tool to help convey information and to help clarify values. Objective: The overall goal of this study is to provide evidence of the reliability and validity of a PCS anxiety measure and the Decisional Conflict Scale (DCS). Methods. Using data from a randomized, controlled PCS decision aid trial that measured PCS anxiety at baseline and DCS at baseline (T0) and at two-weeks (T2), four psychometric properties were assessed: (1) internal consistency reliability, indicated by factor analysis intraclass correlations and Cronbach's α; (2) construct validity, indicated by patterns of Pearson correlations among subscales; (3) discriminant validity, indicated by the measure's ability to discriminate between undecided men and those with a definite screening intention; and (4) factor validity and invariance using confirmatory factor analyses (CFA). Results. The PCS anxiety measure had adequate internal consistency reliability and good construct and discriminant validity. CFAs indicated that the 3-factor model did not have adequate fit. CFAs for a general PCS anxiety measure and a PSA anxiety measure indicated adequate fit. The general PCS anxiety measure was invariant across clinics. The DCS had adequate internal consistency reliability except for the support subscale and had adequate discriminate validity. Good construct validity was found at the private clinic, but was only found for the feeling informed subscale at the public clinic. The traditional DCS did not have adequate fit at T0 or at T2. The alternative DCS had adequate fit at T0 but was not identified at T2. Factor loadings indicated that two subscales, feeling informed and feeling clear about values, were not distinct factors. Conclusions. Our general PCS anxiety measure can be used in PCS decision aid studies. The alternative DCS may be appropriate for men eligible for PCS. Implications: More emphasis needs to be placed on the development of PCS anxiety items relating to testing procedures. We recommend that the two DCS versions be validated in other samples of men eligible for PCS and in other health care decisions that involve uncertainty. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The number of infections of cardiac implantable electronic devices (CIED) continues to escalate out of proportion to the increase rate of device implantation. Staphylococcal organisms account for 70% to 90% of all CIED infections. However, little is known about non-staphylococcal infections, which have been described only in case reports, small case series or combined in larger studies with staphylococcal CIED infections, thereby diluting their individual impact. ^ Methods. A retrospective review of hospital records of patients admitted with a CIED-related infections were identified within four academic hospitals in Houston, Texas between 2002 and 2009. ^ Results. Of the 504 identified patients with CIED-related infection, 80 (16%) had a non-staphylococcal infection and were the focus of this study. Although the demographics and comorbities of subjects were comparable to other reports, our study illustrates many key points: (a) the microbiologic diversity of non-staphylococcal infections was rather extensive, as it included other Gram-positive bacteria like streptococci and enterococci, a variety of Gram-negative bacteria, atypical bacteria including Nocardia and Mycobacteria, and fungi like Candida and Aspergillus; (b) the duration of CIED insertion prior to non-staphylococcal infection was relatively prolong (mean, 109 ± 27 weeks), of these 44% had their device previously manipulated within a mean of 29.5 ± 6 weeks; (c) non-staphylococcal organisms appear to be less virulent, cause prolonged clinical symptoms prior to admission (mean, 48 ± 12.8 days), and are associated with a lower mortality (4%) than staphylococcal organisms; (d) thirteen patients (16%) presented with CIED-related endocarditis; (e) although not described in prior reports, we identified 3 definite and 2 suspected cases of secondary Gram-negative bacteremia seeding of the CIED; and (f) inappropriate antimicrobial coverage was provided in approximately 50% of patients with non-staphylococcal infections for a mean period of 2.1 days. ^ Conclusions. Non-staphylococcal CIED-related infections are prevalent and diverse with a relatively low virulence and mortality rate. Since non-staphylococcal organisms are capable of secondarily seeding the CIED, a high suspicion for CIED-related infection is warranted in patients with bloodstream infection. Additionally, in patients with suspected CIED infection, adequate Gram positive and -negative antibacterial coverage should be administered until microbiologic data become available.^