840 resultados para coronal deformity
Resumo:
Introduction: A growing interest to preserve teeth into the mouth by patients resulted in the increasing number of endodontic retreatments, and when these happen, many different types of irritants are extruded through the foramen. Objective: This study analyzed in vitro the amount of debris extruded through the foramen using four instrumentation techniques during endodontic retreatment. Material and methods: Forty mesial-buccal roots of first molars were selected, instrumented with anatomical diameter up to size #30 ISO file and then obturated with gutta-percha and grossman sealer by lateral condensation. After, they were separated and randomly allocated into four groups with 10 teeth each for the endodontic retreatment procedure: G1 – conventional technique + solvent, G2 – conventional technique without solvent, G3 – ProTaper retreatment + solvent, G4 – ProTaper retreatment without solvent. In all groups, gutta-percha in the coronal portion was removed by using size 1-3 Gates Glidden drills. All teeth were irrigated with distilled water. The debris extruded through the foramen were collected and weighed by an analytical balance. Results: Group 4 had the lowest average for material extrusion through the foramen followed by groups 2, 3 and 1. When Tukey test for statistical analysis was applied, no significant difference among groups were found (p = 0.5664). Conclusion: We conclude that all instrumentation techniques used in this study produced debris which goes beyond the foramen.
Resumo:
Aim: To assess the immediate influence of dentine bonding systems (DBS) associated with 2% chlorhexidine digluconate (CHX) on glass-fibre post-bond strength to root dentine, in terms of coronal, middle and apical thirds. Methodology: Sixty bovine roots were root filled and randomly assigned to 1 of 6 groups (n = 10): SBMP (3-step etch-and-rinse system, Scotchbond Multi-Purpose), SB (2-step etch-and-rinse system, Single Bond 2), SE (2-step self-etching system, Clearfil SE Bond) and SBMP-CHX, SB-CHX and SE-CHX, respectively, associated with CHX. For all groups, a glassfibre post was luted with a dual-cure resin cement, RelyX ARC. After 7-day storage, specimens were subjected to the push-out test. Failure modes were analysed under optical microscopy (40x). Bond strength values were statistically analysed by two-way ANOVA and Bonferroni tests (P < 0.05). Results: The effect of DBS was significant (P < 0.05), and SE reached higher bond strength in comparison with the other DBS tested. CHX association did not show improvement with any DBS (P > 0.05); rather, it negatively affected SE, which was detected for all thirds. There was no difference between thirds (P > 0.05), except for the SE-CHX, which presented lower values for the apical third (P < 0.05). Adhesive cement/dentine adhesive failure was predominant for all groups. CHX did not influence the failure mode for any DBS (P > 0.05). Conclusions: The performance of the dentine bonding systems was material dependent. CHX did not improve immediate bond strength; however, CHX negatively affected the bond strength of the self-etching system, especially in the third apical
Resumo:
Background: In epidemiological surveys, a good reliability among the examiners regarding the caries detection method is essential. However, training and calibrating those examiners is an arduous task because it involves several patients who are examined many times. To facilitate this step, we aimed to propose a laboratory methodology to simulate the examinations performed to detect caries lesions using the International Caries Detection and Assessment System (ICDAS) in epidemiological surveys. Methods: A benchmark examiner conducted all training sessions. A total of 67 exfoliated primary teeth, varying from sound to extensive cavitated, were set in seven arch models to simulate complete mouths in primary dentition. Sixteen examiners (graduate students) evaluated all surfaces of the teeth under illumination using buccal mirrors and ball-ended probe in two occasions, using only coronal primary caries scores of the ICDAS. As reference standard, two different examiners assessed the proximal surfaces by direct visual inspection, classifying them in sound, with non-cavitated or with cavitated lesions. After, teeth were sectioned in the bucco-lingual direction, and the examiners assessed the sections in stereomicroscope, classifying the occlusal and smooth surfaces according to lesion depth. Inter-examiner reproducibility was evaluated using weighted kappa. Sensitivities and specificities were calculated at two thresholds: all lesions and advanced lesions (cavitated lesions in proximal surfaces and lesions reaching the dentine in occlusal and smooth surfaces). Conclusion: The methodology purposed for training and calibration of several examiners designated for epidemiological surveys of dental caries in preschool children using the ICDAS is feasible, permitting the assessment of reliability and accuracy of the examiners previously to the survey´s development.
Resumo:
Since instrumentation of the apical foramen has been suggested for cleaning and disinfection of the cemental canal, selection of the file size and position of the apical foramen have challenging steps. This study analyzed the influence of apical foramen lateral opening and file size can exert on cemental canal instrumentation. Thirty-four human maxillary central incisors were divided in two groups: Group 1 (n=17), without flaring, and Group 2 (n=17), with flaring with LA Axxess burs. K-files of increasing diameters were progressively inserted into the canal until binding at the apical foramen was achieved and tips were visible and bonded with ethyl cyanoacrylate adhesive. Roots/files set were cross-sectioned 5 mm from the apex. Apices were examined by scanning electron microscopy at ×140 and digital images were captured. Data were analyzed statistically by Student’s t test and Fisher’s exact test at 5% significance level. SEM micrographs showed that 19 (56%) apical foramina emerged laterally to the root apex, whereas 15 (44%) coincided with it. Significantly more difficulty to reach the apical foramen was noted in Group 2. Results suggest that the larger the foraminal file size, the more difficult the apical foramen instrumentation may be in laterally emerged cemental canals.
Resumo:
PURPOSE: To verify whether the number of chewing strokes and the chewing time are influenced by dentofacial deformities in habitual free mastication. METHODS: Participants were 15 patients with diagnosis of class II dentofacial deformity (GII), 15 with class III (GIII), and 15 healthy control individuals with no deformity (CG). Free habitual mastication of a cornstarch cookie was analyzed, considering the number of chewing strokes and the time needed to complete two mastications. Strokes were counted by considering the opening and closing movements of the mandible. The time needed to consume each bite was determined using a digital chronometer, started after the placement of the food in the oral cavity and stopped when each portion was swallowed. RESULTS: There were no differences between groups regarding both the number of strokes and the chewing time. However, with regards to the number of strokes, CG and GII presented a significant concordance between the first and the second chewing situation, which was not observed in GIII. The analysis of time showed significant concordance between the first and second chewing situation in CG, reasonable concordance in GII, and discordance in GIII. CONCLUSION: Dentofacial deformities do not influence the number of chewing strokes or the chewing time. However, class III individuals do not show uniformity regarding these aspects.
Resumo:
New Cosmic Origins Spectrograph (COS) observing modes have extended the Hubble Space Telescope's spectral range to wavelengths between 900-1150 Å. However, the G140L/1280 and the Cycle 19 available G130M central wavelengths (1055 and 1096) that sample below 1150 Å were only available at focus positions which provided low-resolution (R<3,000). For HST Cycle 20, we introduced a new G130M/1222 central wavelength that covers 1065-1365 Å with R>10,000 everywhere, but optimized for 15000 from 1080-1200 Å. This mode places geo-coronal Lyα between the COS FUV detector segments to minimize detector gain sag. Also for Cycle 20, the resolution of the G130M/1055 and 1096 modes will be increased by a factor of 3-4 by optimizing the focus positions for these modes. This will give HST approximately the effective area of FUSE over the FUSE bandpass at 10,000. Here we present the current calibration status of the COS G130M/1055, 1096, and 1222 central wavelength settings at the original and second FUV lifetime positions with an emphasis on observing over the "Lyman UV", or "LUV", 912-1216 Å.
Resumo:
[EN]Red porgy is a candidate species for marine aquaculture diversification.The objective of the present study was to describe the osteological development and the occurrence of skeletal deformities in Pagrus pagrus larvae in relation to the intensification of the rearing system. Fish samples were periodically collected along the development from hatching to juveniles (95days after hatching). Osteological development and the presence of skeleton abnormalities were evaluated. X-ray studies revealed a high number of fish (Semi-intensive:38.8%; Intensive:46.5 %) with skeletal deformities. No significant interaction was found on the incidence of lordosis and fused vertebrae with the rearing tecnique. However, cranial abnormalities and kyphosis incidences were significantly higher in intensive system cultured red porgy. Also, the position of fused vertebrae in this fish was located mainly in the caudal area instead of pre-hemal area for semi-intensive system reared red porgy. Present results, suggest a relationship among feeding sequence, osteological development and deformity incidence and location in red porgy larvae
Resumo:
[ES] Main deformities such as lordosis, opercular deformities and upper/lower jaws shortening are considered as quality descriptors in commercial marine fish fry production and seem to be related with larval culture conditions in early larval stages. The aim of this work was to obtain information about the contribution of the diet and rearing system to the apparition of these abnormalities in gilthead sea bream (Sparus aurata) larvae in semi-industrial scale facilities. For that purpose, two different larval rearing systems semi-intensive and intensive were compared; besides, two different rotifer enrichments, DHA Protein Selco, (Inve Aquaculture, Dendermonde, Belgium) (R1) and Red Pepper Paste, (Bernaqua bvba, Turnhout, Belgium) were tested in the intensive system. Biochemical composition of larvae, preys and commercial products was analysed. At 50 days post hatching six hundred fish per treatment were individually studied under stereoscope and deformity frequency recorded. Besides at 95 days post hatching fry were soft X ray monitored. Both rotifer enrichment and rearing system affected survival, growth and deformity frequency. Rearing system did not affect total larvae fatty acid content except at 20 dah, where DHA were significantly higher and EPA significantly lower in Semi-intensive system. A significantly lower percentage of deformity rates together with better survival and growth were obtained in the semi-intensive system. In dietary treatment, rotifer enrichment significantly affected larval survival. R1 rotifers enrichment significantly (P<0.05) improved survival when compared to fed R2 larvae. The content of DPA was significantly (P<0.05) higher in R2 fed larvae reflecting the R2 rotifers content of this fatty acid. The level of this FA tended to decrease in concordance with the rotifers replacement by artemia in the diet. The effects n-3-HUFA and DPA (22:5n-6) over larval survival and skeletal deformities development is discussed.
Resumo:
[EN] Main deformities such as lordosis, opercular deformities and upper/lower jaws shortening are considered as quality descriptors in commercial marine fish fry production and seem to be related at least with larval culture conditions in early larval stages. The aim of this work was to obtain information about the contribution of the diet and rearing system to the apparition of these abnormalities in gilthead sea bream (Sparus aurata) larvae in semi-industrial scale facilities. For that purpose, two different larval rearing systems semi-intensive and intensive were compared by duplicate and with the same live feed enrichments; besides, two different rotifer enrichments were tested in an intensive system. Biochemical composition of larvae, preys and commercial products was analysed. At 50 days post hatching six hundred fish per treatment were individually studied under stereoscope and abnormalities frequency recorded. At 95 days post hatching fry were soft X ray monitored as well. Survival and malformation frequency were significantly different between treatments, the effect of diet and system are discussed. A significantly lower percentage of deformity rates together with better survival and growth were obtained in the semi-intensive system, whereas the rotifer enrichment significantly affected larval survival.
Resumo:
In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.
Resumo:
This Thesis studies the dynamics of hot and cold gas outside the plane in galaxies like the Milky-Way (extra-planar gas) and focuses on the interaction between disc and halo material. Stationary models for the cold phase of the extra-planar gas are presented. They show that the kinematics of this phase must be influenced by the interaction with an ambient medium that we identify as the hot cosmological corona that surrounds disc galaxies. To study this interaction a novel hydrodynamical code has been implemented and a series of hydrodynamical simulations has been run to investigate the mass and momentum exchange between the cold extra-planar gas clouds and the hot corona. These simulations show that the coronal gas can condense efficiently in the turbulent wakes that form behind the cold clouds and it can be accreted by the disc to sustain star formation. They also predict that the corona cannot be a static structure but it must rotate and lag by approximately 80-120 km/s with respect to the disc. Implications of the results of this Thesis for the evolution of star-forming galaxies and for the large-scale dynamics of galactic coronae are also briefly discussed.
Resumo:
Für diese Arbeit wurden sechs neue Benzodiazepinderivate, TC07, TC08, TC09, TC10, TC11 und TC12, hergestellt. Diese wurden mittels Radioligandenbindungsassay sowohl auf ihre Bindungseigenschaften für Membranen des Cerebellum, des Hippo-campus und des Cortex der Ratte hin untersucht, als auch für Membranen von HEK293 Zellen, die transient rekombinante GABAA Rezeptoren exprimierten. Zusätz-lich wurden kompetitive in situ Rezeptorautoradiographien an Rattenhirnschnitten mit den Liganden [3H]Ro15-4513 und [3H]R015-1788 durchgeführt. Zusammen ergaben sich aus diesen Experimenten deutliche Hinweise auf eine Selektivität der Verbindun-gen TC07, TC11 und TC12 für a5-Untereinheiten enthaltende GABAA Rezeptoren mit a5-Affinitäten im niedrigen nanomolaren Bereich. In vivo Bindungsexperimente in Ratten, mit [3H]Ro15-1788 als Tracer und TC07 als Kompetitor, ergaben, dass TC07 mehr [3H]Ro15-1788 im Vorderhirn als im Cerebellum verdrängt. Bezog man die regionale Verteilung der a5-Untereinheit des GABAA Rezep-tors im Rattenhirn mit ein – sehr wenige a5-Untereinheiten im Cerebellum, etwa 20 % der GABAA Rezeptor-Untereinheiten im Hippocampus – untermauerten diese Ergeb-nisse die Vermutung, TC07 könne a5-selektiv sein. Diese Daten bestätigten darü-berhinaus, dass TC07 die Blut-Hirn-Schranke passieren kann. Für elektrophysiologische Messungen mit TC07 und TC12 wurden die oben erwähnten transient transfizierten HEK293 Zellen verwendet, welche die GABAA Rezeptor Unte-reinheitenkombination a5b3g2 exprimierten. Das Dosis-Antwort Verhalten ergab keinen signifikanten Effekt für TC12. Die Daten von TC07 dagegen lassen auf einen schwach negativ modulatorischen Effekt schließen, was, zumindest theoretisch, die Möglichkeit eröffnet, TC07 auch als sogenannten cognitive enhancer einzusetzen. Der errechnete Ki-Wert lag in derselben Größenordnung wie der Ki-Wert, der anhand der Bindungsas-saydaten errechnet wurde. Insgesamt rechtfertigen die bisherigen Ergebnisse die radiochemische Markierung mit 18F von drei der sechs getesteten Verbindungen in der Reihenfolge TC07, TC12 und TC11. Des Weiteren wurde [18F]MHMZ, ein potentiell 5-HT2A selektiver Ligand und PET-Tracer einschließlich Vorläufer und Referenzverbindungen, mit hohen Ausbeuten syn-thetisiert (Herth, Debus et al. 2008). Autoradiographieexperimente mit Rattenhirn-schnitten zeigten hervorragende in situ Bindungseigenschaften der neuen Verbindung. Die Daten wiesen eine hohe Selektivität für 5-HT2A Rezeptoren in Verbindung mit einer niedrigen unspezifischen Bindung auf. [18F]MHMZ erfährt in vivo eine schnelle Metabo-lisierung, wobei ein polarer aktiver Metabolit entsteht, welcher vermutlich nicht die Blut-Hirn-Schranke passieren kann. Transversale, sagittale und coronale Kleintier-PET-Bilder des Rattenhirns zeigten eine hohe Anreicherung im frontalen Cortex und im Striatum, während im Cerebellum so gut wie keine Anreicherung festzustellen war. Diese Verteilung deckt sich mit der bekann-ten Verteilung der 5-HT2A Rezeptoren. Die in vivo Anreicherung scheint sich ebenfalls gut mit der Verteilung der in den Autoradiographieexperimenten gemessenen Bindung zu decken. Nach Berechnungen mit dem 4-Parameter Referenzgewebe Modell beträgt das Bindungspotential (BP) für den frontalen Cortex 1,45. Das Cortex zu Cerebellum Verhältnis wurde auf 2,7 nach 30 Minuten Messzeit bestimmt, was bemerkenswert nah an den von Lundkvist et al. für [11C]MDL 100907 publizierten Daten liegt. Abgesehen von der etwas niedrigeren Affinität waren die gemessenen in vitro, in situ und in vivo Daten denen von [3H]MDL 100907 und [11C]MDL 100907 sehr ähnlich, so dass wir ein [18F]Analogon in der Hand haben, das die bessere Selektivität von MDL 100907 verglichen mit Altanserin mit der längeren Halbwertszeit und den besse-ren Eigenschaften für die klinische Routine von 18F verglichen mit 11C verbindet. Die Ergebnisse von [18F]MHMZ rechtfertigenden weitere Experimente, um diesen Liganden für die klinische Routine am Menschen nutzbar zu machen.
Resumo:
In the last decade, sensitive observations have revealed that disc galaxies are surrounded by multiphase gaseous halos produced by the circulation of gas from the discs to the environment and vice-versa. This Thesis is a study of the gaseous halo of the Milky Way carried out via the modelling of the HI emission and the available absorption-line data. We fitted simple kinematical models to the HI LAB Survey and found that the Galaxy has a massive (~3x10^8 Mo) HI halo extending a few kiloparsecs above the plane. This layer rotates more slowly than the disc and shows a global inflow motion, a kinematics similar to that observed in the HI halos of nearby galaxies. We built a dynamical model of the galactic fountain to reproduce the properties of this layer. In this model, fountain clouds are ejected from the disc by SN feedback and - as suggested by hydrodynamical simulations - triggers the cooling of coronal gas, which is entrained by the cloud wakes and accretes onto the disc when the clouds fall back. For a proper choice of the parameters, the model reproduces well the HI data and predicts an accretion of coronal gas onto the disc at a rate of 2 Mo/yr. We extended this model to the warm-hot component of the halo, showing that most of the ion absorption features observed towards background sources are consistent with being produced in the turbulent wakes that lag behind the fountain clouds. Specifically, the column densities, positions, and velocities of the absorbers are well reproduced by our model. Finally, we studied the gas content of galaxies extracted from a cosmological N-body+SPH simulation, and found that an HI halo with the forementioned properties is not observed, probably due ti the relatively low resolution of the simulations.
Resumo:
Il rachide è stato suddiviso in tre colonne da Denis: anteriore e centrale comprendono la metà anteriore del corpo vertebrale, la metà posteriore e l’inizio dei peduncoli, mentre la colonna posteriore comprende l’arco e i peduncoli stessi. In caso di resezione o lesione della colonna anteriore e media è indicata la ricostruzione. Diverse tecniche e materiali possono essere usati per ricostruire il corpo vertebrale. Innesti vascolarizzati, autograft, allograft sono stati usati, così come impianti sintetici di titanio o materiale plastico come il PEEK (Poly etere etere ketone). Tutti questi materiali hanno vantaggi e svantaggi in termini di proprietà intrinseche, resistenza meccanica, modulo di elasticità, possibilità di trasmissione malattie, capacità di fondersi con l’osso ospite o meno. Le soluzioni più usate sono le cage in titanio o carbonio, il PMMA ( Poli methil metacrilato), gli innesti ossei massivi. Si è effettuato uno studio di coorte retrospettivo paragonando due gruppi di pazienti oncologici spinali trattati da due chirurghi esperti in un centro di riferimento, con vertebrectomia e ricostruzione della colonna anteriore: un gruppo con cage in carbonio o titanio, l’altro gruppo con allograft massivo armato di innesto autoplastico o mesh in titanio. Si sono confrontati i risultati in termini di cifosi segmenterai evolutiva, fusione ossea e qualità di vita del paziente. Il gruppo delle cage in carbonio / titanio ha avuto risultati leggermente migliori dal punto di vista biomeccanico ma non statisticamente significativo, mentre dal punto di vista della qualità di vita i risultati sono stati migliori nel gruppo allograft. Non ci sono stati fallimenti meccanici della colonna anteriore in entrambi i gruppi, con un Fu tra 12 e 60 mesi. Si sono paragonati anche i costi delle due tecniche. In conclusione l’allogar è una tecnica sicura ed efficace, con proprietà meccaniche solide, soprattutto se armato con autograft o mesi in titanio.
Resumo:
Subthreshold resonance is a characteristic membrane property of different neuronal classes, is critically involved in the generation of network oscillations, and tunes the integration of synaptic inputs to particular frequency ranges. In order to investigate whether resonance properties of distinct neuronal populations in the immature neocortex contribute to these network oscillations, I performed whole-cell patch-clamp recordings from visually identified neurons in tangential and coronal neocortical slices from postnatal day (P) P0-P7 C57Bl/6 and P6-P13 GAD67-GFP knock-in mice. Subthreshold resonance was analyzed by sinusoidal current injection of varying frequency. All Cajal-Retzius cells showed subthreshold resonance with an average frequency of 2.6 ± 0.1 Hz (n=60), which was massively reduced by ZD7288, a blocker of hyperpolarization-activated cation currents. About 65.6% (n=61) of the supragranular pyramidal neurons showed subthreshold resonance with an average frequency of 1.4 ± 0.1 Hz (n=40). Application of 1 mM Ni2+ suppressed subthreshold resonance, suggesting that low-threshold Ca2+ currents contribute to resonance in these neurons. About 63.6% (n=77) of the layer V pyramidal neurons showed subthreshold resonance with an average frequency of 1.4 ± 0.2 Hz (n=49), which was abolished by ZD7288. Only 44.1% (n=59) of the subplate neurons showed subthreshold resonance with an average frequency of 1.3 ± 0.2 Hz (n=26) and a small resonance strength. Finally, 50% of the investigated GABAergic interneurons showed subthreshold resonance with an average frequency of 2.0 ± 0.2 Hz (n=42). Membrane hyperpolarization to –86 mV attenuated the frequency and strength of subthreshold resonance. Subthreshold resonance was virtually abolished in the presence of 1 mM Ni2+, suggesting that t-type Ca2+ currents are critically involved in the generation of resonance, while ZD7288 had no effect. Application of 0.4 µM TTX suppressed subthreshold resonance at depolarized, but not hyperpolarized membrane potential, suggesting that persistent Na+ current contribute to the amplification of membrane resonance. rnIn summary, these results demonstrate that all investigated neuronal subpopulations reveal resonance behavior, with either hyperpolarization-activated cation or low-threshold Ca2+ currents contributing to the subthreshold resonance. GABAergic interneurons also express subthreshold resonance at low frequencies, with t-type Ca2+ and persistent Na+ currents underlying the generation of membrane resonance. The membrane resonance of immature neurons may contribute to the generation of slow oscillatory activity pattern in the immature neocortex and enhance the temporal precision of synaptic integration in developing cortical neurons.rn