826 resultados para Rapid Screen
Resumo:
The objective of the present study was to develop and apply the direct immunohistochemistry (D-IHC) assay to search for turkey coronavirus (TCoV) antigens in formalin-fixed embedded-paraffin tissues by the use of biotin-labeled polyclonal antibody. Twenty-eight-day-old embryonated turkey eggs (n = 50) were inoculated with TCoV-purified virus, and 3 d after inoculation, sections from ileum, ileum-cecal junction, and ceca were harvested, fixed in neutral formalin, and embedded in paraffin blocks and used as positive control. In addition, a total of 100 field samples from ileum, ileum-cecal junction, and ceca, collected from 30 to 45-d-old turkeys poults experiencing an outbreak of acute enteritis, were used to search for TCoV by the same D-IHC. All results were compared with those obtained by conventional RT-PCR and indirect fluorescent antibody assay (IFA) for all tested samples. Turkey coronavirus was detected in experimentally infected embryo tissues and also in field samples in 100% of ileum-cecal junction and ceca by the 3 detection procedures. With IFA as a reference assay, sensitivity and specificity of D-IHC were 98 and 58%, whereas sensitivity and specificity of reverse transcription-PCR were 96 and 66%, calculated from the total of tested samples from experimental infection. Each of the examined procedures was highly specific (D-IHC, 93%; RT-PCR, 90%), sensitive (D-IHC, 85%; RT-PCR, 86%), and agreement of both D-IHC and RT-PCR was 99 and 100%, respectively, compared with IFA results obtained from all the field samples. These findings demonstrated the utility of D-IHC for direct detection of TCoV from field samples and considering the sensitivity and specificity found here, can be used as an alternative technique.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
One of the characteristics of diabetes mellitus is the exaggerated inflammatory response. The present report shows the reaction from the use of a rapid maxillary expander in a diabetic patient. A 9-year-old child presented an uncommon reaction to the treatment with a rapid maxillary expander, and on follow-up examination, it was discovered that the patient had diabetes mellitus. After controlling the disease, the proposed treatment was used without further incidents. The case calls attention to the presence of uncommon responses to treatment and the need for the orthodontist to suspect a patient's systemic compromise. (Angle Orthod. 2011;81:546-550.)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A rapid and simple method was developed for quantitation of polar compounds in fats and oils using monostearin as internal standard. Starting from 50 mg of oil sample, polar compounds were obtained by solid-phase extraction (silica cartridges) and subsequently separated by high-performance size-exclusion chromatography into triglyceride polymers, triglyceride dimers, oxidized triglyceride monomers, diglycerides, internal standard and fatty acids. Quantitation of total polar compounds was achieved through the internal standard method and then amounts of each group of compounds could be calculated. A pool of polar compounds was used to check linearity, precision and accuracy of the method, as well as the solid-phase extraction recovery. The procedure was applied to samples with different content of polar compounds and good quantitative results were obtained, especially for samples of low alteration level.
Resumo:
Strontium barium niobate (SBN) thin films were crystallized by conventional electric furnace annealing and by rapid-thermal annealing (RTA) at different temperatures. The average grain size of films was 70 nm and thickness around 500 nm. Using x-ray diffraction, we identified the presence of polycrystalline SBN phase for films annealed from 500 to 700 °C in both cases. Phases such as SrNb2O6 and BaNb2O6 were predominantly crystallized in films annealed at 500 °C, disappearing at higher temperatures. Dielectric and ferroelectric parameters obtained from films crystallized by conventional furnace and RTA presented essentially the same values.
Resumo:
Barium titanate thick films were prepared from mechanically activated powders based on BaCO 3 and TiO 2. The thick films were screen-printed on alumina substrates electroded with Ag/Pd. The BT films were sintered at 850°C for 1 hour. The thickness was 30-75 μm depending of number of layers. The microstructure of thick films and the compatibility between BT layers and substrate was investigated by SEM. The dielectric properties were measured and the results were reported.
Resumo:
A rapid and efficient method is described for the determination of thiabendazole and imazalil residues in lemons (peel and pulp). The procedure is based on the extraction with an hexane:ethyl acetate mixture (1:1, v/v) and gas chromatographic analysis using thermionic specific detection (TSD). The possibility of matrix effect was also studied. Mean recoveries from 8 replicates of fortified samples ranged from 79% to 109%, with relative standard deviation values between 2.4% to 12.8%. The detection and quantification limits of the method were 0.2 mg kg-1 and 0.5 mg kg-1, respectively.
Resumo:
A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.