952 resultados para Pulse Measurement
Resumo:
The Bartlett-Lewis Rectangular Pulse Modified (BLPRM) model simulates the precipitous slide in the hourly and sub-hourly and has six parameters for each of the twelve months of the year. This study aimed to evaluate the behavior of precipitation series in the duration of 15 min, obtained by simulation using the model BLPRM in situations: (a) where the parameters are estimated from a combination of statistics, creating five different sets; (b) suitability of the model to generate rain. To adjust the parameters were used rain gauge records of Pelotas/RS/Brazil, which statistics were estimated - mean, variance, covariance, autocorrelation coefficient of lag 1, the proportion of dry days in the period considered. The results showed that the parameters related to the time of onset of precipitation (λ) and intensities (μx) were the most stable and the most unstable were ν parameter, related to rain duration. The BLPRM model adequately represented the mean, variance, and proportion of the dry period of the series of precipitation lasting 15 min and, the time dependence of the heights of rain, represented autocorrelation coefficient of the first retardation was statistically less simulated series suitability for the duration of 15 min.
Resumo:
Att övervaka förekomsten av giftiga komponenter i naturliga vattendrag är nödvändigt för människans välmående. Eftersom halten av föroreningar i naturens ekosystem bör hållas möjligast låg, pågår en ständig jakt efter kemiska analysmetoder med allt lägre detektionsgränser. I dagens läge görs miljöanalyser med dyr och sofistikerad instrumentering som kräver mycket underhåll. Jonselektiva elektroder har flera goda egenskaper som t.ex. bärbarhet, låg energiförbrukning, och dessutom är de relativt kostnadseffektiva. Att använda jonselektiva elektroder vid miljöanalyser är möjligt om deras känslighetsområde kan utvidgas genom att sänka deras detektionsgränser. För att sänka detektionsgränsen för Pb(II)-selektiva elektroder undersöktes olika typer av jonselektiva membran som baserades på polyakrylat-kopolymerer, PVC och PbS/Ag2S. Fast-fas elektroder med membran av PbS/Ag2S är i allmänhet enklare och mer robusta än konventionella elektroder vid spårämnesanalys av joniska föroreningar. Fast-fas elektrodernas detektionsgräns sänktes i detta arbete med en nyutvecklad galvanostatisk polariseringsmetod och de kunde sedan framgångsrikt användas för kvantitativa bestämningar av bly(II)-halter i miljöprov som hade samlats in i den finska skärgården nära tidigare industriområden. Analysresultaten som erhölls med jonselektiva elektroder bekräftades med andra analytiska metoder. Att sänka detektionsgränsen m.hj.a. den nyutvecklade polariseringsmetoden möjliggör bestämning av låga och ultra-låga blyhalter som inte kunde nås med klassisk potentiometri. Den verkliga fördelen med att använda dessa blyselektiva elektroder är möjligheten att utföra mätningar i obehandlade miljöprov trots närvaron av fasta partiklar vilket inte är möjligt att göra med andra analysmetoder. Jag väntar mig att den nyutvecklade polariseringsmetoden kommer att sätta en trend i spårämnesanalys med jonselektiva elektroder.
Resumo:
Atherosclerotic vascular disease is the leading cause of death in the Western world. Its main three manifestations are coronary heart disease, cerebrovascular disease, and peripheral arterial disease. Asymptomatic peripheral arterial disease is usually diagnosed using the ankle brachial index, and values ≤ 0.90 are used to determine the diagnosis. The classical risk factors of peripheral arterial disease, such as smoking and diabetes, are well known and early interventions are mandatory to improve the prognosis. What is not well known is the role of inflammation as a risk factor. Yet, a novel approach to cardiovascular diseases is the measurement of endothelial function. In this thesis, we studied the ankle-brachial index, C-reactive protein and endothelial function in a cardiovascular risk population. A total of 2856 subjects were invited to the study and 2085 (73%) responded. From these subjects, a cohort of 1756 risk persons was screened. We excluded the subjects with previously known cardiovascular disease or diabetes, because they were already under systematic follow-up. Out of the study subjects, 983 (56%) were women and 773 (44%) men. The ankle brachial index and high-sensitivity C-reactive protein were measured from 1047 subjects. Endothelial function was assessed by measuring reactive hyperemia pulse amplitude tonometry from 66 subjects with borderline peripheral arterial disease. In this study, smoking was a crucial risk factor for peripheral arterial disease. Subclinical peripheral arterial disease seems to be more common in hypertensive patients even without comorbidities. The measurement of the ankle brachial index is an efficient method to identify patients at an increased cardiovascular risk. High-sensitivity C-reactive protein did not correlate with the ankle brachial index or peripheral arterial disease. Instead, it correlated with measures of obesity. In a cardiovascular risk population with borderline peripheral arterial disease, nearly every fourth subject had endothelial dysfunction. This might point out a subgroup of individuals in need of more intensive treatment for their risk factors.
Resumo:
Intellectual assets have attained continuous attention in the academic field, as they are vital sources of competitive advantage and organizational performance in the contemporary knowledge intensive business environment. Intellectual capital measurement is quite thoroughly addressed in the accounting literature. However, the purpose of the measurement is to support the management of intellectual assets, but the reciprocal relationship between measurement and management has not been comprehensively considered in the literature. The theoretical motivation for this study rose from this paradox, as in order to maximise the effectiveness of knowledge management the two initiatives need to be closely integrated. The research approach of this interventionist case study is constructive. The objective is to develop the case organization’s knowledge management and intellectual capital measurement in a way that they would be closely integrated and the measurement would support the management of intellectual assets. The case analysis provides valuable practical considerations about the integration and related issues as the case company is a knowledge intensive organization in which the know-how of the employees is the central competitive asset and therefore, the management and measurement of knowledge are essential for its future success. The results suggest that the case organization is confronting challenges in managing knowledge. In order to appropriately manage knowledge processes and control the related risks, support from intellectual capital measurement is required. However, challenges in measuring intellectual capital, especially knowledge, could be recognized in the organization. By reflecting the knowledge management situation and the constructed strategy map, a new intellectual measurement system was developed for the case organization. The construction of the system as well as its indicators can be perceived to contribute to the literature, emphasizing of the importance of properly considering the organization’s knowledge situation in developing an intellectual capital measurement system.
Resumo:
This thesis describes the process of design and modeling of instrument for knee joint kinematics measurement that can work for both in-vivo and in-vitro subjects. It is designed to be compatible with imaging machine in a sagittal plane. Due to the invasiveness of the imaging machine, the instrument is designed to be able to function independently. The flexibility of this instrument allows to measure anthropometrically different subject. Among the sixth degree of freedom of a knee, three rotational and one translational degree of freedom can be measured for both type of subject. The translational, proximal-distal, motion is stimulated by external force directly applied along its axis. These angular and linear displacements are measured by magnetic sensors and high precision potentiometers respectively
Resumo:
PURPOSE: To evaluate genes differentially expressed in ovaries from lean (wild type) and obese (ob/ob) female mice and cyclic AMP production in both groups.METHODS: The expression on messenger RNA levels of 84 genes concerning obesity was analyzed through the PCR array, and cyclic AMP was quantified by the enzyme immunoassay method.RESULTS: The most downregulated genes in the Obesity Group included adenylate cyclase-activating polypeptide type 1, somatostatin, apolipoprotein A4, pancreatic colipase, and interleukin-1 beta. The mean decrease in expression levels of these genes was around 96, 40, 9, 4.2 and 3.6-fold, respectively. On the other hand, the most upregulated genes in the Obesity Group were receptor (calcitonin) activity-modifying protein 3, peroxisome proliferator activated receptor alpha, calcitonin receptor, and corticotropin-releasing hormone receptor 1. The increase means in the expression levels of such genes were 2.3, 2.7, 4.8 and 6.3-fold, respectively. The ovarian cyclic AMP production was significantly higher in ob/ob female mice (2,229±52 fMol) compared to the Control Group (1,814±45 fMol).CONCLUSIONS: Obese and anovulatory female mice have reduced reproductive hormone levels and altered ovogenesis. Several genes have their expression levels altered when leptin is absent, especially adenylate cyclase-activating polypeptide type 1.
Resumo:
The objective of this study was to find out the factors that affect customer profitability in the not-for-profit case company. The customer profitability was examined in two different segments of the customer base. The effects that price, cost and the amount of services provided have on the profit margin were studied. The distribution of profitability among the customers and the effect of certain characteristics, such as size of the customer measured in services purchased, on the profitability were analyzed. The theoretical framework was built around customer profitability and the use of customer profitability information in a not-for-profit organization. The present use of customer profitability information and the possibilities of using the results of this research in the case company were presented. Quantitative research methods were used in the empirical part of the study. The results indicate that the two customer segments have differences in their buying behaviors which affect the profitability and thus the measures taken to improve the profitability should be considered with the different characteristics of the customers in mind. Finally the limitations of the study were discussed as possible further research topics.
Resumo:
Measurement is a tool for researching. Therefore, it is important that the measuring process is carried out correctly, without distorting the signal or the measured event. Researches of thermoelectric phenomena have been focused more on transverse thermoelectric phenomena during recent decades. Transverse Seebeck effect enables to produce thinner and faster heat flux sensor than before. Studies about transverse Seebeck effect have so far focused on materials, so in this Master’s Thesis instrumentation of transverse Seebeck effect based heat flux sensor is studied, This Master’s Thesis examines an equivalent circuit of transverse Seebeck effect heat flux sensors, their connectivity to electronics and choosing and design a right type amplifier. The research is carried out with a case study which is Gradient Heat Flux Sensors and an electrical motor. In this work, a general equivalent circuit was presented for the transverse Seebeck effect-based heat flux sensor. An amplifier was designed for the sensor of the case study, and the solution was produced for the measurement of the local heat flux of the electric motor to improve the electromagnetic compatibility.
Resumo:
This master’s thesis is devoted to study different heat flux measurement techniques such as differential temperature sensors, semi-infinite surface temperature methods, calorimetric sensors and gradient heat flux sensors. The possibility to use Gradient Heat Flux Sensors (GHFS) to measure heat flux in the combustion chamber of compression ignited reciprocating internal combustion engines was considered in more detail. A. Mityakov conducted an experiment, where Gradient Heat Flux Sensor was placed in four stroke diesel engine Indenor XL4D to measure heat flux in the combustion chamber. The results which were obtained from the experiment were compared with model’s numerical output. This model (a one – dimensional single zone model) was implemented with help of MathCAD and the result of this implementation is graph of heat flux in combustion chamber in relation to the crank angle. The values of heat flux throughout the cycle obtained with aid of heat flux sensor and theoretically were sufficiently similar, but not identical. Such deviation is rather common for this type of experiment.
Resumo:
Both atom localization and Raman cooling, considered in the thesis, reflect recent progress in the area of all-optical methods. We focus on twodimensional (2D) case, using a four-level tripod-type atomic scheme for atom localization within the optical half-wavelength as well as for efficient subrecoil Raman cooling. In the first part, we discuss the principles of 1D atom localization, accompanying by an example of the measurement of a spontaneously-emitted photon. Modifying this example, one archives sub-wavelength localization of a three-level -type atom, measuring the population in its upper state. We go further and obtain 2D sub-wavelength localization for a four-level tripod-type atom. The upper-state population is classified according to the spatial distribution, which in turn forms such structures as spikes, craters and waves. The second part of the thesis is devoted to Raman cooling. The cooling process is controlled by a sequence of velocity-selective transfers from one to another ground state. So far, 1D deep subrecoil cooling has been carried out with the sequence of square or Blackman pulses, applied to -type atoms. In turn, we discuss the transfer of atoms by stimulated Raman adiabatic passage (STIRAP), which provides robustness against the pulse duration if the cooling time is not in any critical role. A tripod-type atomic scheme is used for the purpose of 2D Raman cooling, allowing one to increase the efficiency and simplify the realization of the cooling.
Resumo:
Pulse Response Based Control (PRBC) is a recently developed minimum time control method for flexible structures. The flexible behavior of the structure is represented through a set of discrete time sequences, which are the responses of the structure due to rectangular force pulses. The rectangular force pulses are given by the actuators that control the structure. The set of pulse responses, desired outputs, and force bounds form a numerical optimization problem. The solution of the optimization problem is a minimum time piecewise constant control sequence for driving the system to a desired final state. The method was developed for driving positive semi-definite systems. In case the system is positive definite, some final states of the system may not be reachable. Necessary conditions for reachability of the final states are derived for systems with a finite number of degrees of freedom. Numerical results are presented that confirm the derived analytical conditions. Numerical simulations of maneuvers of distributed parameter systems have shown a relationship between the error in the estimated minimum control time and sampling interval
Resumo:
This work analyzes an active fuzzy logic control system in a Rijke type pulse combustor. During the system development, a study of the existing types of control for pulse combustion was carried out and a simulation model was implemented to be used with the package Matlab and Simulink. Blocks which were not available in the simulator library were developed. A fuzzy controller was developed and its membership functions and inference rules were established. The obtained simulation showed that fuzzy logic is viable in the control of combustion instabilities. The obtained results indicated that the control system responded to pulses in an efficient and desirable way. It was verified that the system needed approximately 0.2 s to increase the tube internal pressure from 30 to 90 mbar, with an assumed total delay of 2 ms. The effects of delay variation were studied. Convergence was always obtained and general performance was not affected by the delay. The controller sends a pressure signal in phase with the Rijke tube internal pressure signal, through the speakers, when an increase the oscillations pressure amplitude is desired. On the other hand, when a decrease of the tube internal pressure amplitude is desired, the controller sends a signal 180º out of phase.
Resumo:
One of the problems that slows the development of off-line programming is the low static and dynamic positioning accuracy of robots. Robot calibration improves the positioning accuracy and can also be used as a diagnostic tool in robot production and maintenance. A large number of robot measurement systems are now available commercially. Yet, there is a dearth of systems that are portable, accurate and low cost. In this work a measurement system that can fill this gap in local calibration is presented. The measurement system consists of a single CCD camera mounted on the robot tool flange with a wide angle lens, and uses space resection models to measure the end-effector pose relative to a world coordinate system, considering radial distortions. Scale factors and image center are obtained with innovative techniques, making use of a multiview approach. The target plate consists of a grid of white dots impressed on a black photographic paper, and mounted on the sides of a 90-degree angle plate. Results show that the achieved average accuracy varies from 0.2mm to 0.4mm, at distances from the target from 600mm to 1000mm respectively, with different camera orientations.
Resumo:
This study concerns performance measurement and management in a collaborative network. Collaboration between companies has been increased in recent years due to the turbulent operating environment. The literature shows that there is a need for more comprehensive research on performance measurement in networks and the use of measurement information in their management. This study examines the development process and uses of a performance measurement system supporting performance management in a collaborative network. There are two main research questions: how to design a performance measurement system for a collaborative network and how to manage performance in a collaborative network. The work can be characterised as a qualitative single case study. The empirical data was collected in a Finnish collaborative network, which consists of a leading company and a reseller network. The work is based on five research articles applying various research methods. The research questions are examined at the network level and at the single network partner level. The study contributes to the earlier literature by producing new and deeper understanding of network-level performance measurement and management. A three-step process model is presented to support the performance measurement system design process. The process model has been tested in another collaborative network. The study also examines the factors affecting the process of designing the measurement system. The results show that a participatory development style, network culture, and outside facilitators have a positive effect on the design process. The study increases understanding of how to manage performance in a collaborative network and what kind of uses of performance information can be identified in a collaborative network. The results show that the performance measurement system is an applicable tool to manage the performance of a network. The results reveal that trust and openness increased during the utilisation of the performance measurement system, and operations became more transparent. The study also presents a management model that evaluates the maturity of performance management in a collaborative network. The model is a practical tool that helps to analyse the current stage of the performance management of a collaborative network and to develop it further.