936 resultados para Pneumonia : Confidence


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present study, clinical and epidemiological aspects of 529 intoxication cases of organophosphate or carbamate pesticides in the northwest of the state of Parana, Brazil, over a twelve-year period (1994-2005), are presented. One hundred-five of 257 patients (40.8%) who attempted suicide were admitted to Intensive Care Units (ICUs), with an average hospital stay of two days (range 1-40 days). Men corresponded to 56.4% of the cases of suicide attempts and sixteen individuals died. One hundred-forty patients intoxicated due to occupational exposure were all young adults and nine of them were admitted to ICU, with average hospital stays of eight days (range 1-16 days). Of these cases, two patients died. One hundred twenty-four patients intoxicated due to accidental exposure were mainly children and had a hospital average stay of four days. Twenty patients were admitted to the ICU, and one of them died. Overall complications included respiratory failure, convulsions, and aspiration pneumonia. Deliberate ingestion of organophosphates and carbamates Was much more toxic than occupational and accidental exposure. Men aged 15-39 years were the most likely to attempt suicide with these agents and had more prolonged ICU with significant complications and mortality

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate bioequivalence of two commercial 8 mg tablet formulations of ondansetrona available ill the Brazilian market. In this study, a simple, rapid, sensitive and selective liquid chromarography-tandem mass spectrometry method is described for the determination of ondansetron in human plasma samples. The method was validated over a concentration range of 2.5-60 ng/ml and used in a bioequivalence trial between orally disintegrating and conventional tablet ondansetron formulations, to assess its usefulness in this kind of Study. Vonau flash (R) (Biolab Sanus Farmaceutica, Brazil, as test formulations) and Zofran (R) (GlaxoSmithKline, Brazil, as reference formulation) were evaluated following a single 8 mg close to 23 healthy volunteers of both genders. The dose was administered after an overnight fast according to a two-way crossover design. Bioequivalence between the products was determinated by Calculating 90% confidence interval (90% CI) for the ratio of C(max), AUC(0-t) and AUC(0-(sic)) values for the test and reference products, using logarithmically transformed data. The 90% confidence interval for the ratio of C(max) (87.5-103.8%), AUC(0-t) (89.3-107.2%) and AUC(0--(sic)) (89.7-106.0%) values for the test and reference products is Within the 80-125% interval, proposed by FDA, EMEA and ANVISA. It was concluded that two ondansetron formulations are bioequivalent ill their rate and extent of absorption. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The bioequivalence of two different tablet formulations of tirtidazole (CAS 19387-91-8) was determined in healthy volunteers after a single dose in a randomized crossover study, with a 1-week washout period between the doses. Reference and test products were administered to 24 volunteers with 240 mL water after overnight fasting. Plasma concentrations of tinidazole were monitored by a high-performance liquid chromatographic method (HPLC) over a period of 72 h after the administration. The pharmacokinetic parameters AUC(0-t), AUC(0-infinity), C(max), T(max), T((1/2)el) and beta were determined from plasma concentration time profile of both formulations and found to be in good agreement with previously reported values. The calculated pharmacokinetic parameters were compared statistically to evaluate bioequivalence between the two brands. The analysis of variance (ANOVA) did not show any significant difference between the two formulations and 90% confidence intervals for the ratio of C(max) (93.9 - 102.6%), AUC(0-t), (94.9-101.1%) and AUC(0-infinity) (94.6-100.8%) values for the test and reference products were within the 80 - 125% interval, satisfying bioequivalence criteria of the European Committee for Proprietary Medicinal Products and the US Food and Drug Administration Guidelines. These results indicate that the test and the reference products of tinidazole are bioequivalent and, thus, may be prescribed interchangeably.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clavulanic acid (CA) is a beta-lactam antibiotic, which has a potent beta-lactamase inhibiting activity. The influence of five variables, namely pH (6.0, 6.4, and 6.8), temperature (28A degrees C, 30A degrees C, and 32A degrees C), agitation intensity (150, 200, and 250 rpm), glycerol concentration (5.0, 7.5, and 10 g/L) and soybean flour concentration (5.0, 12.5, and 20 g/L), on CA production by a new isolate of Streptomyces (DAUFPE 3060) was investigated in 250-mL Erlenmeyer flasks using a fractional factorial design. Temperature and soybean flour concentration were shown to be the two variables that exerted the most important effects on the production of CA at 95% confidence level. The highest CA concentration (494 mg/L) was obtained after 48 h at 150 rpm, 32A degrees C, pH 6.0, 5.0 g/L glycerol, and 20 g/L soybean flour concentrations. Under these conditions, the yields of biomass and product on consumed substrate were 0.26 g(X)/g(S) and 64.3 mg(P)/g(S), respectively. Fermentations performed in 3.0-L bench-scale fermenter allowed increasing the CA production by about 60%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 mu m column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine (R), Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption. Copyright (C) 2009 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Much information on flavonoid content of Brazilian foods has already been obtained; however, this information is spread in scientific publications and non-published data. The objectives of this work were to compile and evaluate the quality of national flavonoid data according to the United States Department of Agriculture`s Data Quality Evaluation System (USDA-DQES) with few modifications, for future dissemination in the TBCA-USP (Brazilian Food Composition Database). For the compilation, the most abundant compounds in the flavonoid subclasses were considered (flavonols, flavones, isoflavones, flavanones, flavan-3-ols, and anthocyanidins) and the analysis of the compounds by HPLC was adopted as criteria for data inclusion. The evaluation system considers five categories, and the maximum score assigned to each category is 20. For each data, a confidence code (CC) was attributed (A, B, C and D), indicating the quality and reliability of the information. Flavonoid data (773) present in 197 Brazilian foods were evaluated. The CC ""C"" (as average) was attributed to 99% of the data and ""B"" (above average) to 1%. The main categories assigned low average scores were: number of samples; sampling plan and analytical quality control (average scores 2, 5 and 4, respectively). The analytical method category received an average score of 9. The category assigned the highest score was the sample handling (20 average). These results show that researchers need to be conscious about the importance of the number and plan of evaluated samples and the complete description and documentation of all the processes of methodology execution and analytical quality control. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A stability-indicating high-performance liquid chromatographic (HPLC) and a second-order derivative spectrophotometric (UVDS) analytical methods were validated and compared for determination of simvastatin in tablets. The HPLC method was performed with isocratic elution using a C18 column and a mobile phase composed of methanol:acetonitrile:water (60:20:20, v/v/v) at a flow rate of 1.0 ml/min. The detection was made at 239 nm. In UVDS method, methanol and water were used in first dilution and distilled water was used in consecutive dilutions and as background. The second-order derivative signal measurement was taken at 255 nm. Analytical curves showed correlation coefficients > 0.999 for both methods. The quantitation limits (QL) were 2.41 mu g/ml for HPLC and 0.45 mu g/ml for UVDS, respectively. Intra and inter-day relative standard deviations were < 2.0 %. Statistical analysis with t- and F-tests are not exceeding their critical values demonstrating that there is no significant difference between the two methods at 95 % confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to propose a biomonitoring method for the simultaneous determination of Cd and Pb in whole blood by simultaneous electrothermal atomic absorption spectrometry for assessment of environmental levels. A volume of 200 mu L of whole blood was diluted in 500 mu L of 0.2% (w v(-1)) Triton(R) X-100 + 2.0% (v v(-1)) HNO3. Trichloroacetic acid was added for protein precipitation and the supernatant analyzed. A mixture of 250 mu g W + 200 mu g Rh as permanent and 2.0% (w v(-1)) NH4H2PO4 as co-injected modifiers were used. Characteristic masses and limits of detections (n = 20, 3s) for Cd and Pb were 1.26 and 33 pg and 0.026 mu g L-1 and 0.65 mu g L-1, respectively. Repeatability ranged from 1.8 to 6.8% for Cd and 1.2 to 1.7% for Pb. The trueness of method was checked by the analysis of three Reference Materials: Lyphocheck(R) Whole Blood Metals Control level 1 and Seronorm(TM) Trace Elements in Whole Blood levels 1 and 2. The found concentrations presented no statistical differences at the 95% confidence level. Blood samples from 40 volunteers without occupational exposure were analyzed and the concentrations ranged from 0.13 to 0.71 mu g L-1 (0.32 +/- 0.19 mu g L-1) for Cd and 9.3 to 56.7 mu g L-1 (25.1 +/- 10.8 mu g L-1) for Pb. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two different cefadroxil (CAS 50370-12-2) formulations were evaluated for their relative bioavailability in 24 healthy volunteers who received a single 500 mg oral dose of each preparation. An open, randomized clinical trial designed as a two-period crossover study with a 7-day washout period between doses was employed. Plasma samples for assessments of their cefadroxil concentration by HPLC-UV were obtained over 8 h after administration. Values of 48.94 +/- 10.18 mu g . h/ml for test, and 48.51 +/- 9.02 mu g . h/ml for the reference preparation AUC(0-t) demonstrate a nearly identical extend of drug absorption. Maximum plasma concentration C-max of 16.04 +/- 4.94 mu g/ml and 16.01 +/- 4.02 mu g/ml achieved for the test and reference preparations did not differ significantly. The parametric 90% confidence intervals (CI) of the mean of the difference (test-reference) between log-transformed values of the two formulations were 96.80% to 104.51% and 92.01% to 107.00% for AUC(0-t) and C-max, respectively. Since for both AUC(0-t) or C-max the 90% CI values are within the interval proposed by the Food and Drug Administration, the test product is bioequivalent to the reference product for both the rate and extent of absorption after single dose administration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A high-performance liquid chromatographic method with triple-quadrupole mass spectrometry detection (LC-MS-MS) was developed and validated for the first time for the simultaneous quantification of zopiclone and its metabolites in rat plasma samples. The analytes were isolated from rat plasma by liquid-liquid extraction and separated using a chiral stationary phase based on an amylose derivative, Chiralpak ADR-H column, and ethanol-methanol-acetonitrile (50:45:5, v/v/v) plus 0.025% diethylamine as the mobile phase, at a flow-rate of 1.0 mL min(-1). Moclobemide was used as the internal standard. The developed method was linear over the concentration range of 7.5-500 ng mL(-1). The mean absolute recoveries were 74.6 and 75.7; 61.6 and 56.9; 72.5, and 70.7 for zopiclone enantiomers, for N-desmethyl zopiclone enantiomers and for zopiclone-N-oxide enantiomers, respectively, and 75.9 for the internal standard. Precision and accuracy were within acceptable levels of confidence (<15%). The method application in a pilot study of zopiclone kinetic disposition in rats showed that the levels of (+)-(S)-zopiclone were always higher than those of (-)-R-zopiclone. Higher concentrations were also observed for (+)-(S)-N-desmethyl zopiclone and (+)-(S)-N-oxide zopiclone, confirming the stereoselective disposition of zopiclone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microcystins (MC) are a family of hepatotoxic cyclic heptapeptides produced by a number of different cyanobacterial species. Considering the recent advances in the characterization of deprotonated peptides by mass spectrometry, the fragmentation behavior of four structurally related microcystin compounds was investigated using collision-induced dissociation (CID) experiments on an orbitrap mass spectrometer. It is demonstrated in this study that significant structural information can be obtained from the CID spectra of deprotonated microcystins. A predominant ring-opening reaction at the isoMeAsp residue, as well as two major complementary fragmentation pathways, was observed, reducing the complexity of the product ion spectra in comparison with spectra observed from protonated species. This proposed fragmentation behavior was applied to characterize [Leu(1)]MC-LR from a cyanobacterial cell extract. In conclusion, CID spectra of microcystins in the negative ion mode provide rich structurally informative mass spectra which greatly enhance confidence in structural assignments, in particular when combined with complementary positive ion CID spectra. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the determination of artemether (ART) and its main metabolite dihydroartemisinin (DHA) in plasma employing liquid-phase microextraction (LPME) for sample preparation prior to liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed. The analytes were extracted from 1 nil, of plasma utilizing a two-phase LPME procedure with artemisinin as internal standard. Using the optimized LPME conditions, mean absolute recovery rates of 25 and 32% for DHA and ART, respectively, were achieved using toluene-n-octanol (1:1, viv) as organic phase with an extraction time of 30 min. After extraction, the analytes were resolved within 5 min using a mobile phase consisting of methanol-ammonium acetate (10 mmol L(-1) pH 5.0, 80:20. v/v) on a laboratory-made column based on poly(methyltetradecylsiloxane) attached to a zirconized-silica support. MS-MS detection was employed using an electrospray interface in the positive ion mode. The method developed was linear over the range of 5-1000 ng mL(-1) for both analytes. Precision and accuracy were within acceptable levels of confidence (<15%). The assay was applied to the determination of these analytes in plasma from rats treated with ART. The two-phase LPME procedure is affordable and the solvent consumption was very low compared to the traditional methods of sample preparation. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chlorpheniramine maleate (CLOR) enantiomers were quantified by ultraviolet spectroscopy and partial least squares regression. The CLOR enantiomers were prepared as inclusion complexes with beta-cyclodextrin and 1-butanol with mole fractions in the range from 50 to 100%. For the multivariate calibration the outliers were detected and excluded and variable selection was performed by interval partial least squares and a genetic algorithm. Figures of merit showed results for accuracy of 3.63 and 2.83% (S)-CLOR for root mean square errors of calibration and prediction, respectively. The ellipse confidence region included the point for the intercept and the slope of 1 and 0, respectively. Precision and analytical sensitivity were 0.57 and 0.50% (S)-CLOR, respectively. The sensitivity, selectivity, adjustment, and signal-to-noise ratio were also determined. The model was validated by a paired t test with the results obtained by high-performance liquid chromatography proposed by the European pharmacopoeia and circular dichroism spectroscopy. The results showed there was no significant difference between the methods at the 95% confidence level, indicating that the proposed method can be used as an alternative to standard procedures for chiral analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A graphite furnace atomic absorption spectrometric method is proposed for the direct and simultaneous determination of Cd, Cu, and Se in human blood. Samples were diluted 1:10 (v/v) in 0.5% (v/v) HNO(3) + 0.5% (v/v) Triton X-100 solution. For 12 mu L injected sample volume + 5 mu L, of 1000 mg L(-1) Pd(NO(3))(2) + 3 mu L of 1000 mg L(-1) Mg(NO(3))(2), the calculated characteristic masses (mo) were 0.9 pg Cd, 16 pg Cu, and 39 pg Se, which are close to those mo values for single-element conditions for THGA furnace (1.3 pg Cd, 17 pg Cu, and 45 pg Se). Calibration curves with linear correlations better than 0.999 were obtained. The limits of detection (LOD) were 0.03 mu g L(-1) Cd, 0.075 mu g L(-1) Cu and 0.3 mu g L(-1) Se, and the relative standard deviations (n= 12) were 2.5%, 0.3%, and 1.5%, respectively. The method was applied for Cd, Cu, and Se determination in 10 human blood samples and the results were in agreement at the 95% confidence level with those obtained by inductively coupled plasma mass spectrometry. Concentrations of analytes in the selected blood samples varied from 1.7 to 3.2 mu g L(-1) Cd, 700 to 921.7 mu g L(-1) Cu, and from 68.6 to 350 mu g L(-1) Se. The accuracy of the proposed method was also evaluated by an addition-recovery experiment and recoveries of Cd, Cu, and Se added to blood samples ranged from 99-109%, 91-103%,and 93-103%, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple method with a fast sample preparation procedure for total and inorganic mercury determinations in blood samples is proposed based on flow injection cold vapor inductively coupled plasma mass spectrometry (FI-CVICP-MS). Aliquots of whole blood (500 mL) are diluted 1 + 1 v/v with 10.0% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 3 h at room temperature and then further diluted 1 + 4 v/v with 2.0% v/v HCl. The inorganic Hg was released by online addition of L-cysteine and then reduced to elemental Hg by SnCl(2). On the other hand, total mercury was determined by on-line addition of KMnO(4) and then reduced to elemental Hg by NaBH(4). Samples were calibrated against matrix-matching. The method detection limit was found to be 0.80 mu g L(-1) and 0.08 mu g L(-1) for inorganic and total mercury, respectively. Sample throughput is 20 samples h(-1). The method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). For additional validation purposes, human whole blood samples were analyzed by the proposed method and by an established CV AAS method, with no statistical difference between the two techniques at 95% confidence level on applying the t-test.