960 resultados para Nd: YAG laser


Relevância:

80.00% 80.00%

Publicador:

Resumo:

用Nd :YAG 5 32nm激光泵浦的混合染料激光得到了在相当于铜蒸气激光器泵浦染料激光的某个波段上增强的激光输出。测得了铀原子在 5 6 2~ 5 86nm波段内的单色三光子共振电离谱中 14 0个能级 ,其中5 75 814和 5 75 836nm两个峰很好地分开了 ,它们的相对强度也能测定。若用单一染料的激光是难以做到 ,因为目前尚无合适的染料在上述波段内能有强的激光输出

Relevância:

80.00% 80.00%

Publicador:

Resumo:

报道了用一束二倍频Nd:YAG激光同步抽运的脉冲染料激光系统,e型电子枪,铀原子束装置以及利用在单原子检测技术基础上发展起来的共振电离光谱和飞行时间质谱同时测量的技术,测量铀原子激发态吸收截面的饱和吸收方法。此法具有相当高灵敏度、高分辨率和强选择性的特点。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

激光双光子电离方法用于水溶液表面的蒽及其衍生物分子的检测。Nd-YAG激光的第三谐波355nm用作激发和电离。光电离电荷数在2~3个数量级内随浓度呈线性关系。胺基蒽和甲基蒽的检出限达到0.2μg/L。这个结果与氮分子激光337um的情况一致,略差于在正乙烷液相中测定的结果。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The gain coefficient of the strongest 3p --> 3s, J = 2 --> 1 lasing transition at 23.6 nm in the Ne-like Ge collisional excitation scheme has been measured, using the fundamental wavelength from a Nd:glass laser (1.06-mu-m), for a range of incident intensities on massive stripe targets up to 2.2 cm in length. From a threshold incident laser intensity of approximately 6 x 10(12) W/cm2, the gain coefficient rises to approximately 4.5 cm-1 for an irradiation intensity of approximately 2.5 x 10(13) W/cm2, tending towards still higher gain coefficients at higher incident intensities. For targets of maximum length, a gain-length product gL almost-equal-to 10 was reached with a resultant output power at 23.6 nm estimated to be at the approximately kW level. The beam divergence decreased with length to a minimum of approximately 7 mrad but no significant trend in beam pointing with plasma length was observed. From the trend in the gain coefficient, it appears that for a fixed energy laser irradiating a approximately 100-mu-m wide slab targets, an incident intensity of I(i) approximately 1.2 x 10(13) W/cm2 represents an optimum working level, assuming that plasma length is not limited by refractive effects. In addition to the usual valence electron excited 3p --> 3s transitions, the gain coefficient for the core excited 1s(2)2s2p(6)3d --> 1s(2)2s2p(6)3p transition at 19.9 nm has been measured to be approximately 1.5 cm-1 for an incident irradiance of approximately 2.5 x 10(13) W/cm2.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pseudophakic retinal detachment is a rare, but potentially serious, complication of cataract surgery. The incidence of pseudophakic retinal detachment following current surgical techniques of cataract extraction, including extracapsular cataract extraction by nuclear expression and phacoemulsification, is lower than that found after intracapsular cataract extraction. The risk of pseudophakic retinal detachment appears to be increased in myopic patients, in those patients in whom vitreous loss had occurred at the time of cataract surgery, and in patients undergoing Nd:YAG posterior capsulotomy. Most cases present to the clinician when the macula is already detached and the central vision is affected. When evaluating patients with pseudophakic retinal detachment, the fundal view is often impaired by anterior or posterior capsular opacification, reflections related to the intraocular lens, or poor mydriasis. Scleral buckling, pneumatic retinopexy, and primary pars plana vitrectomy, with or without combined scleral buckling, are the surgical techniques used to treat pseudophakic retinal detachment. Anatomical success rates are high after vitreo-retinal surgery for pseudophakic retinal detachment, although a smaller proportion of patients recover good vision following surgery. © 2003 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: To study the long-term outcome of deep sclerectomy in patients with open angle glaucoma. Methods: Prospective consecutive series of 43 eyes (38 patients) with medically uncontrolled open-angle glaucoma undergoing deep sclerectomy. All patients underwent clinical assessment before and after surgery at day 7 and at months 1, 3, 6, 12, 18, 24, 36. Surgical success was considered if the patient's intraocular pressure (IOP)>22 mmHg and the IOP was lowered by more than 20% without the use of any medication. Kaplan-Meier survival curves were used to evaluate the success rate. Results: The mean follow-up time was 28.1±8.2 months. Mean IOP decreased significantly from a preoperative value of 24.6±5.5 mmHg to a postoperative value of 18.5±4.6 mmHg at 36 months (P>0.001). Microperforation of TDM occurred in three cases (7.0%) and ciliary body prolapse in one case (2.3%) but did not prevent completion of the operation. Postoperatively, hyphaema was detected in one case and shallow anterior chamber in another case and both were treated conservatively. Bleb encapsulation with elevation of IOP occurred in two cases (4.7%) and was treated with 5-fluorouracil subconjunctival injection. Goniopuncture with neodymium : YAG laser was performed in two cases (4.7%). There were no other late complications with the exception of failure of the operation. On the life-table analysis the success rate at 12, 24, and 30 months were 61.4, 36.6, and 18.9%, respectively. Conclusion: Deep sclerectomy reduced the IOP temporarily while minimising the risk of postoperative complications commonly encountered with standard trabeculectomy. However, after long-term follow-up surgery failed to maintain a low IOP. © 2006 Nature Publishing Group. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The second harmonic generation (SHG) intensity spectrum of SiC, ZnO, GaN two-dimensional hexagonal crystals is calculated by using a real-time first-principles approach based on Green's function theory [Attaccalite et al., Phys. Rev. B: Condens. Matter Mater. Phys. 2013 88, 235113]. This approach allows one to go beyond the independent particle description used in standard first-principles nonlinear optics calculations by including quasiparticle corrections (by means of the GW approximation), crystal local field effects and excitonic effects. Our results show that the SHG spectra obtained using the latter approach differ significantly from their independent particle counterparts. In particular they show strong excitonic resonances at which the SHG intensity is about two times stronger than within the independent particle approximation. All the systems studied (whose stabilities have been predicted theoretically) are transparent and at the same time exhibit a remarkable SHG intensity in the range of frequencies at which Ti:sapphire and Nd:YAG lasers operate; thus they can be of interest for nanoscale nonlinear frequency conversion devices. Specifically the SHG intensity at 800 nm (1.55 eV) ranges from about 40-80 pm V(-1) in ZnO and GaN to 0.6 nm V(-1) in SiC. The latter value in particular is 1 order of magnitude larger than values in standard nonlinear crystals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: To study the effect of posterior capsular opacification (PCO) on vision and visual function in patients undergoing cataract surgery in rural China, and to compare this with the effect of refractive error. METHODS: Patients undergoing cataract surgery in at least one eye by local surgeons in a rural setting between 8 August and 31 December 2005 were examined with slit lamp grading of PCO 10-14 months after surgery. Subjects with any PCO associated with best-corrected visual acuity of 6/7.5 or worse, or with grade 2+ or worse PCO without visual decrement, were offered YAG laser capsulotomy. Vision and self-reported visual function were assessed, and various demographic and clinical factors potentially associated with PCO were recorded. RESULTS: Of 313 patients operated on within the study window, 239 (76%) could be contacted by telephone; study examinations were performed on 176 (74%). Examined subjects had a mean (SD) age of 69.4 (10.5) years, 116 (67%) were female, and 149 (86%) had been blind (presenting visual acuity < or = 6/60) in the operated eye before surgery. PCO of grade 1 or above was present in 34 of 204 operated eyes (16.7%). Those with PCO had significantly worse presenting vision (p = 0.007) but not visual function (p>0.3) than those without PCO. Women had a significantly higher prevalence of PCO (20.9%) than did men (8.6%, p<0.05). Of 19 eyes undergoing capsulotomy with best-corrected visual acuity measured the next day, 13 (68%) improved by one or more lines, and seven (37%) improved by two or more lines. Despite a higher uptake of capsulotomy (95%) as opposed to refraction (35%) in this cohort, the yield in terms of eyes with poor presenting visual acuity (< 6/18) that could be improved was higher for refraction (26% = 9/35) than for capsulotomy (9% = 3/35). CONCLUSION: The prevalence of PCO and impact on vision and visual function in this cohort was modest 1 year after surgery. However, PCO prevalence increases with time. Follow-up of this cohort is underway to determine the effectiveness of this early intervention in identifying and treating subjects who will eventually experience clinically significant PCO.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The current trend toward minimal-invasive dentistry has introduced innovative techniques for cavity preparation. Chemical vapor deposition (CVD) and laser-irradiation technology have been employed as an alternative to the common use of regular burs in high-speed turbines. Objectives. The purpose of this study was to assess the influence of alternative techniques for cavity preparation on the bonding effectiveness of different adhesives to dentin, and to evaluate the morphological characteristics of dentin prepared with those techniques. Methods. One etch&rinse adhesive (OptiBond FL, Kerr) and three self-etch systems (Adper Prompt L-Pop, 3M ESPE; Clearfil SE Bond, Kuraray; Clearfil S3 Bond, Kuraray) were applied on dentin prepared with a regular bur in a turbine, with a CVD bur in a turbine, with a CVD tip in ultrasound and with an ErCr:YSGG laser. The micro-tensile bond strength (mu TBS) was determined after storage in water for 24 h at 37 degrees C, and morphological evaluation was performed by means of field -emission -gun scanning electron microscopy (Feg-SEM). Results. Feg-SEM evaluation revealed different morphological features on the dentin surface after the usage of both the conventional and alternative techniques for cavity preparation, more specifically regarding smear-layer thickness and surface roughness. CVD bur-cut, CVD ultra-sonoabraded and laser-irradiated dentin resulted in lower mu TBSs than conventionally bur-cut dentin, irrespective of the adhesive employed. Significance. The techniques, such as CVD diamond-bur cutting, CVD diamond ultra-sonoabrasion and laser-irradiation, used for cavity preparation may affect the bonding effectiveness of adhesives to dentin, irrespective of their acidity or approach. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness of different light-curing units on the bond strength (push-out) of glass fiber posts in the different thirds of the root (cervical, middle and apical) with different adhesive luting resin systems (dual-cure total-etch; dual-cured and self-etch bonding system; and dual-cure self-adhesive cements), Disks of the samples (n = 144) were used, with approximately 1 mm of thickness of 48 bovine roots restored with glass fiber posts, that were luted with resin cements photo-activated by halogen LCU (QTH, Optilux 501) and blue LED (Ultraled), with power densities of 600 and 550 mW/cm(2), respectively. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0.5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in the different thirds of each sample. The push-out strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey`s test, at significance level of 5%. The results showed that there were no statistical differences between the QTH and LED LCUs. The self-adhesive resin cement had lower values of retention. The total-etch and self-adhesive system resin cements seem to be a possible alternative for glass fiber posts cementation into the radicular canal and the LED LCU can be applied as an alternative to halogen light on photo-activation of dual-cured resin cements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Ibituruna quartz-syenite was emplaced as a sill in the Ribeira-Aracuai Neoproterozoic belt (Southeastern Brazil) during the last stages of the Gondwana supercontinent amalgamation. We have measured the Anisotropy of Magnetic Susceptibility (AMS) in samples from the Ibituruna sill to unravel its magnetic fabric that is regarded as a proxy for its magmatic fabric. A large magnetic anisotropy, dominantly due to magnetite, and a consistent magnetic fabric have been determined over the entire Ibituruna massif. The magmatic foliation and lineation are strikingly parallel to the solid-state mylonitic foliation and lineation measured in the country-rock. Altogether, these observations suggest that the Ibituruna sill was emplaced during the high temperature (similar to 750 degrees C) regional deformation and was deformed before full solidification coherently with its country-rock. Unexpectedly, geochronological data suggest a rather different conclusion. LA-ICP-MS and SHRIMP ages of zircons from the Ibituruna quartz-syenite are in the range 530-535 Ma and LA-ICP-MS ages of zircons and monazites from synkinematic leucocratic veins in the country-rocks suggest a crystallization at similar to 570-580 Ma, i.e., an HT deformation >35My older than the emplacement of the Ibituruna quartz-syenite. Conclusions from the structural and the geochronological studies are therefore conflicting. A possible explanation arises from (40)Ar-(39)Ar thermochronology. We have dated amphiboles from the quartz-syenite, and amphiboles and biotites from the country-rock. Together with the ages of monazites and zircons in the country-rock, (40)Ar-(39)Ar mineral ages suggest a very low cooling rate: <3 degrees C/My between 570 and similar to 500 Ma and similar to 5 degrees C/My between 500 and 460 Ma. Assuming a protracted regional deformation consistent over tens of My, under such stable thermal conditions the fabric and microstructure of deformed rocks may remain almost unchanged even if they underwent and recorded strain pulses separated by long periods of time. This may be a characteristic of slow cooling ""hot orogens"" that rocks deformed at significantly different periods during the orogeny, but under roughly unchanged temperature conditions, may display almost indiscernible microstructure and fabric. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Photoluminescence and photo-excited conductivity data as well as structural analysis are presented for sol-gel SnO2 thin films doped with rare earth ions Eu3+ and Er3+, deposited by sol-gel-dip-coating technique. Photoluminescence spectra are obtained under excitation with various types of monochromatic light sources, such as Kr+, Ar+ and Nd:YAG lasers, besides a Xe lamp plus a selective monochromator with UV grating. The luminescence fine structure is rather different depending on the location of the rare-earth doping, at lattice symmetric sites or segregated at the asymmetric grain boundary layer sites. The decay of photo-excited conductivity also shows different trapping rate depending on the rare-earth concentration. For Er-doped films, above the saturation limit, the evaluated capture energy is higher than for films with concentration below the limit, in good agreement with the different behaviour obtained from luminescence data. For Eu-doped films, the difference in the capture energy is not so evident in these materials with nanoscocopic crystallites, even though the luminescence spectra are rather distinct. It seems that grain boundary scattering plays a major role in Eu-doped SnO2 films. Structural evaluation helps to interpret the electro-optical data. © 2010 IOP Publishing Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To evaluate the effects of surface treatment, surface hydration (SH) and application method (AM) on the tensile bond strength of the Silorane Adhesive System (SAS) to dentine. Methods: Ninety bovine teeth were used. For the control group (n = 10), each dentine surface was treated according to the manufacturer's instructions of the SAS. The remaining teeth were randomly distributed into two groups (n = 40), according to the type of dentine surface treatment (ST) - 37% phosphoric acid or Er:YAG Laser prior to the application of the SAS. Each group was further divided into 2 subgroups (n = 20), according to the SH status: dry (D) or wet (W). Each subgroup was further divided into 2 subgroups (n = 10), according to the application method [AM: Active (AC) mode or Passive (PA) mode]. A coat of resin composite (Filtek P90) was applied on the surface. Artificial ageing was performed with a thermo-mechanical cycling machine. The specimens were sectioned into 1 mm × 1 mm × 10 mm sticks and stressed to failure using a universal testing machine. The remaining teeth in each group were used for Scanning Electron Microscopy to examine the fractured area. Data were subjected to a three-way ANOVA, Tukey's test and Dunnet's test (α = 0.05). Results: The ANOVA showed significant differences for SH and AM, but not for ST. For SH, the results of Tukey's test were (in MPa): D-14.9(±3.8)a, W-17.1(±4.3)b; and for AM: PA-14. 9(±4.2)a, AC-17.1(±3.9) b. Conclusions: Acid etching, when combined with a moist dentine surface and the use of primer agitation, improves the bond strength of the SAS to dentine. Clinical Significance: According to the results of the present in vitro study, modification of the application protocols for the silorane-based adhesive system may improve its clinical performance. © 2012 Published by Elsevier Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)