923 resultados para testing, test, php
Resumo:
Objectives. The null hypothesis was that mechanical testing systems used to determine polymerization stress (sigma(pol)) would rank a series of composites similarly. Methods. Two series of composites were tested in the following systems: universal testing machine (UTM) using glass rods as bonding substrate, UTM/acrylic rods, "low compliance device", and single cantilever device ("Bioman"). One series had five experimental composites containing BisGMA:TEGDMA in equimolar concentrations and 60, 65, 70, 75 or 80 wt% of filler. The other series had five commercial composites: Filtek Z250 (3M ESPE), Filtek A110 (3M ESPE), Tetric Ceram (Ivoclar), Heliomolar (Ivoclar) and Point 4 (Kerr). Specimen geometry, dimensions and curing conditions were similar in all systems. sigma(pol) was monitored for 10 min. Volumetric shrinkage (VS) was measured in a mercury dilatometer and elastic modulus (E) was determined by three-point bending. Shrinkage rate was used as a measure of reaction kinetics. ANOVA/Tukey test was performed for each variable, separately for each series. Results. For the experimental composites, sigma(pol) decreased with filler content in all systems, following the variation in VS. For commercial materials, sigma(pol) did not vary in the UTM/acrylic system and showed very few similarities in rankings in the others tests system. Also, no clear relationships were observed between sigma(pol) and VS or E. Significance. The testing systems showed a good agreement for the experimental composites, but very few similarities for the commercial composites. Therefore, comparison of polymerization stress results from different devices must be done carefully. (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
There are several techniques to characterize the elastic modulus of wood and those currently using the natural frequencies of vibration stand out as they are non-destructive techniques, producing results that can be repeated and compared over time. This study reports on the effectiveness of the testing methods based on the natural frequencies of vibration versus static bending to obtain the elastic properties of reforested structural wood components usually employed in civil construction. The following components were evaluated: 24 beams of Eucalyptus sp. with nominal dimensions (40 x 60 x 2.000 mm) and 14 beams of Pinus oocarpa with nominal dimensions (45 x 90 x 2.300 mm) both without treatment; 30 boards with nominal dimensions (40 x 240 x 2.010 mm) and 30 boards with nominal dimensions (40 x 240 x 3.050 mm), both of Pinus oocarpa and with chromate copper arsenate (CCA) preservative treatment. The results obtained in thiswork show good correlation when compared to the results obtained by the static bending mechanical method, especially when applying the natural frequency of longitudinal vibration. The use of longitudinal frequency was reliable and practical, therefore recommended for determining the modulus of elasticity of wood structural elements. It was also found that no specific support is needed for the specimens using the longitudinal frequency, as well as no previous calibrations, reducing the execution time and enabling to test many samples.
Resumo:
Drug testing is used by employers to detect drug use by employees or job candidates. It can identify recent use of alcohol, prescription drugs, and illicit drugs as a screening tool for potential health and safety and performance issues. Urine is the most commonly used sample for illicit drugs. It detects the use of a drug within the last few days and as such is evidence of recent use; but a positive test does not necessarily mean that the individual was impaired at the time of the test. Abstention from use for three days will often produce a negative test result. Analysis of hair provides a much longer window of detection, typically 1 to 3 months. Hence the likelihood of a falsely negative test using hair is very much less than with a urine test. Conversely, a negative hair test is a substantially stronger indicator of a non-drug user than a negative urine test. Oral fluid (saliva) is also easy to collect. Drugs remain in oral fluid for a similar time as in blood. The method is a good way of detecting current use and is more likely to reflect current impairment. It offers promise as a test in post-accident, for cause, and on-duty situations. Studies have shown that within the same industrial settings, hair testing can detect twice as many drug users as urine testing. Copyright (C) 2012 John Wiley & Sons, Ltd.
Resumo:
Aims: This report discusses the use of antinuclear antibody (ANA) detection as a screening test for neuropsychiatry systemic lupus erythematosus (NPSLE) in patients presenting a first-episode psychosis. Methods: We reviewed the medical records of 85 patients admitted to an emergency service due to first-episode psychosis, during a 1-year period, for whom ANA detection was performed through an IFI HEp2 cell assay. ANA-positive patients were subsequently evaluated for autoantibodies and neuroimaging exams. Results: Three patients presented as ANA positive in the initial screening and further investigation confirmed NPSLE in two patients. The patients were treated with antipsychotics and cyclophosphamide pulses with satisfactory outcomes. Conclusion: Even though ANA detection is not specific, it is a low-cost procedure and could be an important screening test for NPSLE in the early-onset psychosis.
Resumo:
Chaabene, H, Hachana, Y, Franchini, E, Mkaouer, B, Montassar, M, and Chamari, K. Reliability and construct validity of the karate-specific aerobic test. J Strength Cond Res 26(12): 3454-3460, 2012-The aim of this study was to examine absolute and relative reliabilities and external responsiveness of the Karate-specific aerobic test (KSAT). This study comprised 43 male karatekas, 19 of them participated in the first study to establish test-retest reliability and 40, selected on the bases of their karate experience and level of practice, participated in the second study to identify external responsiveness of the KSAT. The latter group was divided into 2 categories: national-level group (G(n)) and regional-level group (Gr). Analysis showed excellent test-retest reliability of time to exhaustion (TE), with intraclass correlation coefficient ICC(3,1) >0.90, standard error of measurement (SEM) <5%: (3.2%) and mean difference (bias) +/- the 95% limits of agreement: -9.5 +/- 78.8 seconds. There was a significant difference between test-retest session in peak lactate concentration (Peak [La]) (9.12 +/- 2.59 vs. 8.05 +/- 2.67 mmol.L-1; p < 0.05) but not in peak heart rate (HRpeak) and rating of perceived exertion (RPE) (196 +/- 9 vs. 194 +/- 9 b.min(-1) and 7.6 +/- 0.93 vs. 7.8 +/- 1.15; p > 0.05), respectively. National-level karate athletes (1,032 +/- 101 seconds) were better than regional level (841 +/- 134 seconds) on TE performance during KSAT (p < 0.001). Thus, KSAT provided good external responsiveness. The area under the receiver operator characteristics curve was >0.70 (0.86; confidence interval 95%: 0.72-0.95). Significant difference was detected in Peak [La] between national- (6.09 +/- 1.78 mmol.L-1) and regional-level (8.48 +/- 2.63 mmol.L-1) groups, but not in HRpeak (194 +/- 8 vs. 195 +/- 8 b.min(-1)) and RPE (7.57 +/- 1.15 vs. 7.42 +/- 1.1), respectively. The result of this study indicates that KSAT provides excellent absolute and relative reliabilities. The KSAT can effectively distinguish karate athletes of different competitive levels. Thus, the KSAT may be suitable for field assessment of aerobic fitness of karate practitioners.
Resumo:
Neurosonological studies, specifically transcranial Doppler (TCD) and transcranial color-coded duplex (TCCD), have high level of specificity and sensitivity and they are used as complementary tests for the diagnosis of brain death (BD). A group of experts, from the Neurosonology Department of the Brazilian Academy of Neurology, created a task force to determine the criteria for the following aspects of diagnosing BD in Brazil: the reliability of TCD methodology; the reliability of TCCD methodology; neurosonology training and skills; the diagnosis of encephalic circulatory arrest; and exam documentation for BD. The results of this meeting are presented in the current paper.
Resumo:
To estimate causal relationships, time series econometricians must be aware of spurious correlation, a problem first mentioned by Yule (1926). To deal with this problem, one can work either with differenced series or multivariate models: VAR (VEC or VECM) models. These models usually include at least one cointegration relation. Although the Bayesian literature on VAR/VEC is quite advanced, Bauwens et al. (1999) highlighted that "the topic of selecting the cointegrating rank has not yet given very useful and convincing results". The present article applies the Full Bayesian Significance Test (FBST), especially designed to deal with sharp hypotheses, to cointegration rank selection tests in VECM time series models. It shows the FBST implementation using both simulated and available (in the literature) data sets. As illustration, standard non informative priors are used.
Resumo:
Background: Pulmonary hypertension is associated with a worse prognosis after cardiac transplantation. The pulmonary hypertension reversibility test with sodium nitroprusside (SNP) is associated with a high rate of systemic arterial hypotension, ventricular dysfunction of the transplanted graft and high rates of disqualification from transplantation. Objective: This study was aimed at comparing the effects of sildenafil (SIL) and SNP on hemodynamic, neurohormonal and echocardiographic variables during the pulmonary reversibility test. Methods: The patients underwent simultaneously right cardiac catheterization, echocardiography, BNP measurement, and venous blood gas analysis before and after receiving either SNP (1 - 2 mu g/kg/min) or SIL (100 mg, single dose). Results: Both drugs reduced pulmonary hypertension, but SNP caused a significant systemic hypotension (mean blood pressure - MBP: 85.2 vs. 69.8 mm Hg; p < 0.001). Both drugs reduced cardiac dimensions and improved left cardiac function (SNP: 23.5 vs. 24.8%, p = 0.02; SIL: 23.8 vs. 26%, p < 0.001) and right cardiac function (SIL: 6.57 +/- 2.08 vs. 8.11 +/- 1.81 cm/s, p = 0.002; SNP: 6.64 +/- 1.51 vs. 7.72 +/- 1.44 cm/s, p = 0.003), measured through left ventricular ejection fraction and tissue Doppler, respectively. Sildenafil, contrary to SNP, improved venous oxygen saturation, measured on venous blood gas analysis. Conclusion: Sildenafil and SNP are vasodilators that significantly reduce pulmonary hypertension and cardiac geometry, in addition to improving biventricular function. Sodium nitroprusside, contrary to SIL, was associated with systemic arterial hypotension and worsening of venous oxygen saturation. (Arq Bras Cardiol 2012;99(3):848-856)
Resumo:
The objective of the present work was to propose a method for testing the contribution of each level of the factors in a genotypes x environments (GxE) interaction using multi-environment trials analyses by means of an F test. The study evaluated a data set, with twenty genotypes and thirty-four environments, in a block design with four replications. The sum of squares within rows (genotypes) and columns (environments) of the GxE matrix was simulated, generating 10000 experiments to verify the empirical distribution. Results indicate a noncentral chi-square distribution for rows and columns of the GxE interaction matrix, which was also verified by the Kolmogorov-Smirnov test and Q-Q plot. Application of the F test identified the genotypes and environments that contributed the most to the GxE interaction. In this way, geneticists can select good genotypes in their studies.
Resumo:
A long-standing problem when testing from a deterministic finite state machine is to guarantee full fault coverage even if the faults introduce extra states in the implementations. It is well known that such tests should include the sequences in a traversal set which contains all input sequences of length defined by the number of extra states. This paper suggests the SPY method, which helps reduce the length of tests by distributing sequences of the traversal set and reducing test branching. It is also demonstrated that an additional assumption about the implementation under test relaxes the requirement of the complete traversal set. The results of the experimental comparison of the proposed method with an existing method indicate that the resulting reduction can reach 40%. Experimental results suggest that the additional assumption about the implementation can help in further reducing the test suite length. Copyright (C) 2011 John Wiley & Sons, Ltd.
Resumo:
Pharmaceutical equivalence is an important step towards the confirmation of similarity and Interchangeability among pharmaceutical products, particularly regarding those that win not be tested for bioequivalence. The aim of this paper is to compare traditional difference testing to two one-side equivalence tests in the assessment of pharmaceutical equivalence, by means of equivalence studies between similar, generic and reference products of acyclovir cream, atropine sulfate injection, meropenem for injection, and metronidazole injection. All tests were performed in accordance with the Brazilian Pharmacopeia or the United States Pharmacopeia. All four possible combinations of results arise in these comparisons of difference testing and equivalence testing. Most of the former did not show significant difference, whereas the latter presented similarity. We concluded that equivalence testing is more appropriate than difference testing, what can make it a useful tool to assess pharmaceutical equivalence in products that will not be tested for bioequivalence.
Resumo:
The objective of this study was to evaluate the push-out bond strength of fiberglass resin reinforced bonded with five ionomer cements. Also, the interface between cement and dentin was inspected by means of SEM. Fifty human canines were chose after rigorous scrutiny process, endodontically treated and divided randomly into five groups (n = 3) according to cement tested: Group I – Ionoseal (VOCO), Group II – Fugi I (GC), Group III – Fugi II Improved (GC), Group IV – Rely X Luting 2 (3M ESPE), Group V – Ketac Cem (3M ESPE). The post-space was prepared to receive a fiberglass post, which was tried before cementation process. No dentin or post surface pretreatment was carried out. After post bonding, all roots were cross-sectioned to acquire 3 thin-slices (1 mm) from three specific regions of tooth (cervical, medium and apical). A Universal test machine was used to carry out the push-out test with cross-head speed set to 0.5mm/mim. All failed specimens were observed under optical microscope to identify the failure mode. Representative specimens from each group was inspected under SEM. The data were analyzed by Kolmogorov-Smirnov and Levene’s tests and by two-way ANOVA, and Tukey’s port hoc test at a significance level of 5%. It was compared the images obtained for determination of types of failures more occurred in different levels. SEM inspection displayed that all cements filled the space between post and dentin, however, some imperfections such bubles and voids were noticed in all groups in some degree of extension. The push-out bond strength showed that cement Ketac Cem presented significant higher results when compared to the Ionoseal (P = 0.02). There were no statistical significant differences among other cements.
Resumo:
OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.
Resumo:
OBJETIVO: Este estudo teve por objetivo a adaptação transcultural do Internet Addiction Test (IAT) para o idioma português. MÉTODOS: O trabalho consistiu em cinco etapas: (1) tradução; (2) retradução; (3) revisão técnica e avaliação da equivalência semântica por profissionais da área; (4) avaliação do instrumento por uma amostra de estudantes, avaliando-se o seu grau de compreensão; e (5) análise da consistência interna por meio do coeficiente alfa de Cronbach. RESULTADOS: O instrumento foi traduzido e adaptado para o idioma português, demonstrando ser facilmente compreendido e apresentando valor de consistência interna de 0,85. CONCLUSÃO: O instrumento encontra-se traduzido e adaptado para o português e apresenta consistência interna satisfatória. São necessárias análises de equivalência de mensuração e reprodutibilidade.